{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,28]],"date-time":"2026-09-28T16:41:32Z","timestamp":1790613692624,"version":"4.1.0"},"reference-count":19,"publisher":"Japanese Society of Radiological Technology","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Nippon Hoshasen Gijutsu Gakkai Zasshi","Jpn. J. Radiol. Technol."],"published-print":{"date-parts":[[2025]]},"DOI":"10.6009\/jjrt.25-1509","type":"journal-article","created":{"date-parts":[[2024,12,22]],"date-time":"2024-12-22T22:11:43Z","timestamp":1734905503000},"page":"n\/a","source":"Crossref","is-referenced-by-count":1,"title":["Evaluation of the Effectiveness of Bladder Ultrasound Imaging Devices in Radiation Therapy","\u653e\u5c04\u7dda\u6cbb\u7642\u306b\u304a\u3051\u308b\u8180\u80f1\u7528\u8d85\u97f3\u6ce2\u753b\u50cf\u8a3a\u65ad\u88c5\u7f6e\u306e\u6709\u52b9\u6027\u8a55\u4fa1"],"prefix":"10.6009","volume":"81","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1416-8800","authenticated-orcid":false,"given":"Yoshiyuki","family":"Kawasaki","sequence":"first","affiliation":[{"name":"Department of Radiology, Okinawa Central Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tatsuya","family":"Yoshida","sequence":"additional","affiliation":[{"name":"Department of Radiology, Tatebayashi Kosei General Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tomoki","family":"Hayakawa","sequence":"additional","affiliation":[{"name":"Department of Radiology, Tatebayashi Kosei General Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Toshiyuki","family":"Kawadai","sequence":"additional","affiliation":[{"name":"Department of Radiology, Tatebayashi Kosei General Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takako","family":"Shibasaki","sequence":"additional","affiliation":[{"name":"Department of Radiology, Tatebayashi Kosei General Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"4040","reference":[{"key":"1","unstructured":"1\uff09\u2003\u56fd\u7acb\u7814\u7a76\u958b\u767a\u6cd5\u4eba\u56fd\u7acb\u304c\u3093\u7814\u7a76\u30bb\u30f3\u30bf\u30fc\u304c\u3093\u60c5\u5831\u30b5\u30fc\u30d3\u30b9\uff0e\u6700\u65b0\u304c\u3093\u7d71\u8a08\uff0ehttps:\/\/ganjoho.jp\/reg_stat\/statistics\/stat\/summary.html (Accessed 05 July 2024)."},{"key":"2","unstructured":"2\uff09\u2003\u65e5\u672c\u653e\u5c04\u7dda\u816b\u760d\u5b66\u4f1a\u7de8\uff0e\u653e\u5c04\u7dda\u6cbb\u7642\u8a08\u753b\u30ac\u30a4\u30c9\u30e9\u30a4\u30f3\uff0e\u91d1\u539f\u51fa\u7248\uff0c\u6771\u4eac\uff0c2020."},{"key":"3","unstructured":"3\uff09\u2003\u5927\u897f\u6d0b\uff0c\u5510\u6fa4\u4e45\u7f8e\u5b50\uff0c\u897f\u5c3e\u798e\u6cbb\u7de8\uff0e\u304c\u3093\u30fb\u653e\u5c04\u7dda\u7642\u6cd5\uff08\u6539\u5b9a\u7b2c8\u7248\uff09\uff0eGakken\uff0c\u6771\u4eac\uff0c2023: 248\u2013253."},{"key":"4","unstructured":"4\uff09\u2003NCCN prostate cancer panel members. NCCN clinical practice guidelines in oncology\u20022022; version 3. 2022."},{"key":"5","doi-asserted-by":"crossref","unstructured":"5\uff09\u2003Aizawa R, Takayama K, Nakamura K, et al. Low incidence of late recurrence in patients with intermediate-risk prostate cancer treated by intensity-modulated radiation therapy plus short-term androgen deprivation therapy. Int J Clin Oncol 2020; 25: 713\u2013719.","DOI":"10.1007\/s10147-019-01596-7"},{"key":"6","doi-asserted-by":"crossref","unstructured":"6\uff09\u2003Aizawa R, Takayama K, Nakamura K, et al. Ten-year outcomes of high-dose intensity-modulated radiation therapy for nonmetastatic prostate cancer with unfavorable risk: early initiation of salvage therapy may replace long-term adjuvant androgen deprivation. Int J Clin Oncol 2019; 24: 1247\u20131255.","DOI":"10.1007\/s10147-019-01478-y"},{"key":"7","doi-asserted-by":"crossref","unstructured":"7\uff09\u2003Tomita N, Soga N, Ogura Y, et al. Favorable 10-year outcomes of image-guided intensity-modulated radiotherapy combined with long-term androgen deprivation for Japanese patients with nonmetastatic prostate cancer. Asia Pac J Clin Oncol 2019; 15: 18\u201325.","DOI":"10.1111\/ajco.13097"},{"key":"8","doi-asserted-by":"crossref","unstructured":"8\uff09\u2003Fujioka C, Ishii K, Yamanaga T, et al. Optimal bladder volume at treatment planning for prostate cancer patients receiving volumetric modulated arc therapy. Pract Radiat Oncol 2016; 6: 395\u2013401.","DOI":"10.1016\/j.prro.2016.05.007"},{"key":"9","unstructured":"9\uff09\u2003\u5ddd\u5d0e\u5584\u5e78\uff0c\u6839\u672c\u5584\u8a89\uff0c\u9752\u6728\u4e45\u8a18\uff0c\u4ed6\uff0e\u524d\u7acb\u817a\u764cIMRT\u6cbb\u7642\u8a08\u753b\u306b\u304a\u3051\u308b\u6700\u9069\u306a\u8180\u80f1\u5bb9\u7a4d\uff0e\u65e5\u653e\u6280\u8a8c\u20022015; 62: 22\u201326."},{"key":"10","unstructured":"10\uff09\u2003\u6210\u7530\u6d69\u4eba\uff0c\u5e84\u53f8\u53cb\u548c\uff0c\u98ef\u7530\u7d00\u4e16\u4e00\u7de8\uff0e\u653e\u5c04\u7dda\u6cbb\u7642\u8a08\u753b\uff0e\u30d4\u30e9\u30fc\u30d7\u30ec\u30b9\uff0c\u6771\u4eac\uff0c2018: 147\u2013153."},{"key":"11","doi-asserted-by":"crossref","unstructured":"11\uff09\u2003Ung KA, White R, Mathlum M, et al. Comparison study of portable bladder scanner versus cone-beam CT scan for measuring bladder volumes in post-prostatectomy patients undergoing radiotherapy. J Med Imaging Radiat Oncol 2014; 58: 377\u2013383.","DOI":"10.1111\/1754-9485.12171"},{"key":"12","doi-asserted-by":"crossref","unstructured":"12\uff09\u2003Stam MR, van Lin ENJT, van der Vight LP, et al. Bladder filling variation during radiation treatment of prostate cancer: can the use of a bladder ultrasound scanner and biofeedback optimize bladder filling? Int J Radiat Oncol Biol Phys 2006; 65: 371\u2013377.","DOI":"10.1016\/j.ijrobp.2005.12.039"},{"key":"13","doi-asserted-by":"crossref","unstructured":"13\uff09\u2003Ohira S, Komiyama R, Kanayama N, et al. Improvement in bladder volume reproducibility using A-mode portable ultrasound bladder scanner in moderate-hypofractionated volumetric modulated arc therapy for prostate cancer patients. J Appl Clin Med Phys 2022; 23: e13546.","DOI":"10.1002\/acm2.13546"},{"key":"14","unstructured":"14\uff09\u2003\u5ddd\u5d0e\u5584\u5e78\uff0c\u6839\u672c\u5584\u8a89\uff0c\u7530\u6240\u4fca\u4ecb\uff0c\u4ed6\uff0e\u8180\u80f1\u7528\u8d85\u97f3\u6ce2\u753b\u50cf\u8a3a\u65ad\u88c5\u7f6e\u306b\u3088\u308b\u8180\u80f1\u5bb9\u7a4d\u6e2c\u5b9a\u306e\u7cbe\u5ea6\uff0eSysmex Journal\u20022013; 36: 84\u201390."},{"key":"15","doi-asserted-by":"crossref","unstructured":"15\uff09\u2003\u96dc\u8cc0\u8cb4\u5927\uff0c\u677e\u672c\u8ce2\u6cbb\uff0e\u9aa8\u76e4\u9818\u57df\uff08\u524d\u7acb\u817a\uff09\u653e\u5c04\u7dda\u6cbb\u7642\u306b\u304a\u3051\u308b\u8180\u80f1\u5bb9\u91cf\u6e2c\u5b9a\u306e\u7cbe\u5ea6\u6bd4\u8f03\uff1a\u30dd\u30fc\u30bf\u30d6\u30eb\u8d85\u97f3\u6ce2\u8a3a\u65ad\u88c5\u7f6e\u3068CBCT\u306e\u6bd4\u8f03\uff0e\u65e5\u653e\u6280\u5b66\u8a8c\u20022024; 80: 760\u2013765.","DOI":"10.6009\/jjrt.2024-1461"},{"key":"16","doi-asserted-by":"crossref","unstructured":"16\uff09\u2003Mullaney L, O\u2019Shea E, Dunne MT, et al. A comparison of bladder volumes based on treatment planning CT and BladderScan<sup>\u00ae<\/sup> BVI 6100 ultrasound device in a prostate radiation therapy population. Br J Radiol 2018; 91: 20180160.","DOI":"10.1259\/bjr.20180160"},{"key":"17","unstructured":"17\uff09\u2003\u67f4\u7530\u771f\u4f51\u91cc\uff0c\u5ca1\u7530\u4e98\uff0c\u4f50\u91ce\u572d\u4f51\uff0c\u4ed6\uff0eArtificial intelligence\u6280\u8853\u3092\u6d3b\u7528\u3057\u305f\u8180\u80f1\u5bb9\u91cf\u81ea\u52d5\u8a08\u6e2c\u6a5f\u80fd\u642d\u8f09\u8d85\u97f3\u6ce2\u88c5\u7f6e\u306e\u653e\u5c04\u7dda\u6cbb\u7642\u306b\u304a\u3051\u308b\u6709\u7528\u6027\uff0e\u65e5\u653e\u6280\u5b66\u8a8c\u20022022; 78: 1406\u20131414."},{"key":"18","doi-asserted-by":"crossref","unstructured":"18\uff09\u2003Kanda Y. Investigation of the freely available easy-to-use software\u2018EZR\u2019 for medical statistics. Bone Marrow Transplant 2013; 48: 452\u2013458.","DOI":"10.1038\/bmt.2012.244"},{"key":"19","unstructured":"19\uff09\u2003\u85ea\u4e2d\u5e78\u4e00\uff0c\u56db\u8c37\u6df3\u5b50\uff0c\u4ef2\u4e0a\u8c6a\u4e8c\u6717\uff0c\u4ed6\uff0e4\u7a2e\u985e\u306e\u8d85\u97f3\u6ce2\u691c\u67fb\u88c5\u7f6e\u306b\u3088\u308b\u8180\u80f1\u5185\u5bb9\u91cf\u6e2c\u5b9a\u306e\u59a5\u5f53\u6027\u306e\u6bd4\u8f03\uff0eJ. Jpn. WOCM\u20022016; 20: 420\u2013425."}],"container-title":["Japanese Journal of Radiological Technology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/jjrt\/81\/2\/81_25-1509\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,12,28]],"date-time":"2024-12-28T03:42:05Z","timestamp":1735357325000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/jjrt\/81\/2\/81_25-1509\/_article\/-char\/ja\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025]]},"references-count":19,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.6009\/jjrt.25-1509","relation":{},"ISSN":["0369-4305","1881-4883"],"issn-type":[{"value":"0369-4305","type":"print"},{"value":"1881-4883","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025]]},"article-number":"25-1509"}}