{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,6,29]],"date-time":"2025-06-29T04:03:04Z","timestamp":1751169784315,"version":"3.41.0"},"reference-count":19,"publisher":"Japanese Society of Radiological Technology","issue":"9","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Nippon Hoshasen Gijutsu Gakkai Zasshi","Jpn. J. Radiol. Technol."],"published-print":{"date-parts":[[2025]]},"DOI":"10.6009\/jjrt.25-1565","type":"journal-article","created":{"date-parts":[[2025,6,26]],"date-time":"2025-06-26T22:08:09Z","timestamp":1750975689000},"page":"n\/a","source":"Crossref","is-referenced-by-count":0,"title":["Reduction of Lens Absorbed Dose through Optimization of the X-ray Tube Position during Localizer Radiograph in Radiation Therapy Planning CT","\u653e\u5c04\u7dda\u6cbb\u7642\u8a08\u753bCT\u306b\u304a\u3051\u308b\u4f4d\u7f6e\u6c7a\u3081\u753b\u50cf\u64ae\u5f71\u6642\u306eX\u7dda\u7ba1\u4f4d\u7f6e\u306b\u3088\u308b\u6c34\u6676\u4f53\u88ab\u3070\u304f\u7dda\u91cf\u4f4e\u6e1b"],"prefix":"10.6009","volume":"81","author":[{"given":"Kenji","family":"Kanemoto","sequence":"first","affiliation":[{"name":"Hiroshima High-Precision Radiotherapy Cancer Center"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Minoru","family":"Nakao","sequence":"additional","affiliation":[{"name":"Hiroshima High-Precision Radiotherapy Cancer Center"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kiyoshi","family":"Yamada","sequence":"additional","affiliation":[{"name":"Hiroshima High-Precision Radiotherapy Cancer Center"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"4040","reference":[{"key":"1","unstructured":"1\uff09\u2003\u65e5\u672c\u653e\u5c04\u7dda\u816b\u760d\u5b66\u4f1a\uff0e\u5168\u56fd\u653e\u5c04\u7dda\u6cbb\u7642\u65bd\u8a2d\u306e2019\u5e74\u5b9a\u671f\u69cb\u9020\u8abf\u67fb\u5831\u544a\uff08\u7b2c1\u5831\uff09\uff0e2022."},{"key":"2","doi-asserted-by":"crossref","unstructured":"2\uff09\u2003Stewart FA, Akleyev AV, Hauer-Jensen M, et al. ICRP publication 118: ICRP statement on tissue reactions and early and late effects of radiation in normal tissues and organs--threshold doses for tissue reactions in a radiation protection context.          Ann ICRP 2012; 41: 1\u2013322.","DOI":"10.1016\/j.icrp.2012.02.001"},{"key":"3","doi-asserted-by":"crossref","unstructured":"3\uff09\u2003Kalender WA, Wolf H, Suess C. Dose reduction in CT by anatomically adapted tube current modulation. II. Phantom measurements. Med Phys 1999; 26: 2248\u20132253.","DOI":"10.1118\/1.598738"},{"key":"4","doi-asserted-by":"crossref","unstructured":"4\uff09\u2003Mukundan S Jr, Wang PI, Frush DP, et al. MOSFET dosimetry for radiation dose assessment of bismuth shielding of the eye in children. AJR Am J Roentgenol 2007; 188: 1648\u20131650.","DOI":"10.2214\/AJR.06.1146"},{"key":"5","doi-asserted-by":"crossref","unstructured":"5\uff09\u2003Matsubara K, Sugai M, Toyoda A, et al. Assessment of an organ-based tube current modulation in thoracic computed tomography. J Appl Clin Med Phys 2012; 13: 148\u2013158.","DOI":"10.1120\/jacmp.v13i2.3731"},{"key":"6","doi-asserted-by":"crossref","unstructured":"6\uff09\u2003Nam JG, Hong JH, Kim DS, et al. Deep learning reconstruction for contrast-enhanced CT of the upper abdomen: similar image quality with lower radiation dose in direct comparison with iterative reconstruction. Eur Radiol 2021; 31: 5533\u20135543.","DOI":"10.1007\/s00330-021-07712-4"},{"key":"7","unstructured":"7\uff09\u2003\u9060\u85e4\u771f\u5e83\uff0c\u5927\u897f\u6d0b\uff0e\u4f53\u5e79\u90e8\u5b9a\u4f4d\u653e\u5c04\u7dda\u6cbb\u7642\u30ac\u30a4\u30c9\u30e9\u30a4\u30f3\uff0e\u65e5\u653e\u7dda\u816b\u760d\u4f1a\u8a8c\u20022006; 18: 1\u201317."},{"key":"8","doi-asserted-by":"crossref","unstructured":"8\uff09\u2003Winslow J, Zhang Y, Koweek L, et al. Dependency of prescribed CT dose on table height, patient size, and localizer acquisition for one clinical MDCT. Phys Med 2018; 55: 56\u201360.","DOI":"10.1016\/j.ejmp.2018.10.015"},{"key":"9","unstructured":"9\uff09\u2003Rasband WS. ImageJ. National Institutes of Health, Bethesda, Maryland, USA. 1997\u20132012. http:\/\/imageJ.nih.gov\/ij\/."},{"key":"10","unstructured":"10\uff09\u2003The Phantom Laboratory. The RANDO<sup>\u00ae<\/sup> Phantom, RAN100 and RAN110. 1-3."},{"key":"11","doi-asserted-by":"crossref","unstructured":"11\uff09\u2003\u6751\u677e\u798e\u4e45\uff0c\u6c60\u7530\u79c0\uff0c\u5927\u6ca2\u4e00\u5f70\uff0c\u4ed6\uff0eCT\u7528\u81ea\u52d5\u9732\u51fa\u6a5f\u69cb\uff08CT-AEC\uff09\u306e\u6027\u80fd\u8a55\u4fa1\u73ed\u3000\u6700\u7d42\u5831\u544a\u66f8\uff0e\u65e5\u653e\u6280\u5b66\u8a8c\u20022007; 63: 534\u2013545.","DOI":"10.6009\/jjrt.63.534"},{"key":"12","unstructured":"12\uff09\u2003\u65e5\u672c\u653e\u5c04\u7dda\u6280\u8853\u5b66\u4f1a\u64ae\u5f71\u90e8\u4f1a\u7de8\uff0eX\u7ddaCT\u64ae\u5f71\u306b\u304a\u3051\u308b\u6a19\u6e96\u5316~GALACTIC~\uff08\u6539\u8a022\u7248\uff09\uff0e\u653e\u5c04\u7dda\u533b\u7642\u6280\u8853\u5b66\u53e2\u66f827. \u65e5\u672c\u653e\u5c04\u7dda\u6280\u8853\u5b66\u4f1a\u51fa\u7248\u59d4\u54e1\u4f1a\uff0c\u4eac\u90fd\uff0c2015."},{"key":"13","unstructured":"13\uff09\u2003Seltzer SM, Hubbell JH. \u653e\u5c04\u7dda\u533b\u7642\u6280\u8853\u5b66\u53e2\u66f811.\u2002\u5149\u5b50\u6e1b\u5f31\u4fc2\u6570\u30c7\u30fc\u30bf\u30d6\u30c3\u30af\uff0e\u65e5\u672c\u653e\u5c04\u7dda\u6280\u8853\u5b66\u4f1a\u51fa\u7248\u59d4\u54e1\u4f1a\uff0c\u4eac\u90fd\uff0c1995."},{"key":"14","unstructured":"14\uff09\u2003\u65e5\u672c\u533b\u5b66\u7269\u7406\u5b66\u4f1a\uff0e\u653e\u5c04\u7dda\u6cbb\u7642\u306b\u304a\u3051\u308b\u86cd\u5149\u30ac\u30e9\u30b9\u7dda\u91cf\u8a08\u7269\u7406\u6280\u8853\u30ac\u30a4\u30c9\u30e9\u30a4\u30f3\uff0e2022."},{"key":"15","doi-asserted-by":"crossref","unstructured":"15\uff09\u2003Kanda Y. Investigation of the freely available easy-to-use software \u201cEZR\u201d for medical statistics. Bone Marrow Transplant 2013; 48: 452\u2013458.","DOI":"10.1038\/bmt.2012.244"},{"key":"16","doi-asserted-by":"crossref","unstructured":"16\uff09\u2003\u6a2a\u753a\u548c\u5fd7\uff0c\u897f\u4e38\u82f1\u6cbb\uff0c\u85e4\u5ca1\u77e5\u52a0\u5b50\uff0c\u4ed6\uff0e\u982d\u90e8CT\u64ae\u5f71\u306b\u304a\u3051\u308b\u982d\u90e8\u56fa\u5b9a\u5177\u304c\u753b\u8cea\u3068\u7dda\u91cf\u306b\u53ca\u307c\u3059\u5f71\u97ff\uff0e\u65e5\u653e\u6280\u5b66\u8a8c\u20022014; 70: 1166\u20131172.","DOI":"10.6009\/jjrt.2014_JSRT_70.10.1166"},{"key":"17","doi-asserted-by":"crossref","unstructured":"17\uff09\u2003\u6a58\u660c\u5e78\uff0c\u6728\u4e0b\u7d75\u7f8e\uff0c\u5e73\u7530\u656c\u5b50\uff0e\u6cbb\u7642\u8a08\u753b\u88c5\u7f6e\u4f7f\u7528\u6642\u306b\u304a\u3051\u308b\u6700\u9069X\u7ddaCT\u753b\u50cf\u306e\u691c\u8a0e\u2014\u753b\u50cf\u30ce\u30a4\u30ba\uff0c\u30b9\u30e9\u30a4\u30b9\u539a\u306b\u3064\u3044\u3066\u2014\uff0e\u65e5\u653e\u6280\u5b66\u8a8c\u20022004; 60: 507\u2013512.","DOI":"10.6009\/jjrt.KJ00000922395"},{"key":"18","doi-asserted-by":"crossref","unstructured":"18\uff09\u2003Papadakis AE, Perisinakis K, Damilakis J. Automatic exposure control in pediatric and adult multidetector CT examinations: a phantom study on dose reduction and image quality. Med Phys 2008; 35: 4567\u20134576.","DOI":"10.1118\/1.2977535"},{"key":"19","unstructured":"19\uff09\u2003\u6728\u5bfa\u4fe1\u592b\uff0c\u677e\u539f\u5b5d\u7950\uff0c\u85e4\u5ca1\u77e5\u52a0\u5b50\uff0c\u4ed6\uff0e\u982d\u90e8CT\u64ae\u5f71\u306b\u304a\u3051\u308b\u6c34\u6676\u4f53\u88ab\u3070\u304f\u306e\u4f4e\u6e1b\u3092\u76ee\u7684\u3068\u3057\u305f\u7ba1\u96fb\u6d41\u5909\u8abf\u6280\u8853\u306e\u6027\u80fd\u7279\u6027\uff0e\u65e5\u653e\u6280\u5b66\u8a8c\u20022020; 76: 366\u2013374."}],"container-title":["Japanese Journal of Radiological Technology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/jjrt\/81\/9\/81_25-1565\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,28]],"date-time":"2025-06-28T03:31:19Z","timestamp":1751081479000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/jjrt\/81\/9\/81_25-1565\/_article\/-char\/ja\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025]]},"references-count":19,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.6009\/jjrt.25-1565","relation":{},"ISSN":["0369-4305","1881-4883"],"issn-type":[{"type":"print","value":"0369-4305"},{"type":"electronic","value":"1881-4883"}],"subject":[],"published":{"date-parts":[[2025]]},"article-number":"25-1565"}}