{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,6]],"date-time":"2025-12-06T04:28:27Z","timestamp":1764995307999,"version":"3.46.0"},"reference-count":25,"publisher":"Japanese Society of Radiological Technology","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Nippon Hoshasen Gijutsu Gakkai Zasshi","Jpn. J. Radiol. Technol."],"published-print":{"date-parts":[[2026]]},"DOI":"10.6009\/jjrt.26-1566","type":"journal-article","created":{"date-parts":[[2025,12,3]],"date-time":"2025-12-03T22:07:36Z","timestamp":1764799656000},"page":"n\/a","source":"Crossref","is-referenced-by-count":0,"title":["Impact of Gantry, Collimator, and Couch Rotational Errors in Radiation Therapy Devices on the Irradiation Accuracy of Off-isocenter Targets and Evaluation of TG142 Tolerance","\u653e\u5c04\u7dda\u6cbb\u7642\u88c5\u7f6e\u306e\u56de\u8ee2\u5ea7\u6a19\u7cfb\u8aa4\u5dee\u304c\u8ef8\u5916target\u306e\u7167\u5c04\u7cbe\u5ea6\u306b\u53ca\u307c\u3059\u5f71\u97ff\u3068TG142\u306e\u30c8\u30ec\u30e9\u30f3\u30b9\u306e\u8a55\u4fa1"],"prefix":"10.6009","volume":"82","author":[{"given":"Takahiro","family":"Nakayama","sequence":"first","affiliation":[{"name":"Department of Radiology, Public Mutual Aid Association Chugoku Central Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7259-3317","authenticated-orcid":false,"given":"Yoshinori","family":"Tanabe","sequence":"additional","affiliation":[{"name":"Department of Radiological Technology, Graduate School of Health Sciences, Okayama University"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yasushi","family":"Fujii","sequence":"additional","affiliation":[{"name":"Department of Radiology, Public Mutual Aid Association Chugoku Central Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"4040","reference":[{"doi-asserted-by":"crossref","unstructured":"1\uff09\u2003Faccenda V, Panizza D, Pisoni V, et al. Single-isocenter linac-based radiosurgery for brain metastases with coplanar arcs: a dosimetric and clinical analysis. Cancers (Basel) 2023; 15: 4496.","key":"1","DOI":"10.3390\/cancers15184496"},{"doi-asserted-by":"crossref","unstructured":"2\uff09\u2003Uto M, Torizuka D, Mizowaki T. Single isocenter stereotactic irradiation for multiple brain metastases: current situation and prospects. Jpn J Radiol 2022; 40: 987\u2013994.","key":"2","DOI":"10.1007\/s11604-022-01333-7"},{"doi-asserted-by":"crossref","unstructured":"3\uff09\u2003Roper J, Chanyavanich V, Betzel G, et al. Single-isocenter multiple-target stereotactic radiosurgery: risk of compromised coverage. Int J Radiat Oncol Biol Phys 2015; 93: 540\u2013546.","key":"3","DOI":"10.1016\/j.ijrobp.2015.07.2262"},{"doi-asserted-by":"crossref","unstructured":"4\uff09\u2003Thomas EM, Popple RA, Wu X, et al. Comparison of plan quality and delivery time between volumetric arc therapy (rapidarc) and gamma knife radiosurgery for multiple cranial metastases. Neurosurgery 2014; 75: 409\u2013418.","key":"4","DOI":"10.1227\/NEU.0000000000000448"},{"doi-asserted-by":"crossref","unstructured":"5\uff09\u2003Minniti G, Capone L, Alongi F, et al. Initial experience with single-isocenter radiosurgery to target multiple brain metastases using an automated treatment planning software: clinical outcomes and optimal target volume margins strategy. Adv Radiat Oncol 2020; 5: 856\u2013864.","key":"5","DOI":"10.1016\/j.adro.2020.06.008"},{"doi-asserted-by":"crossref","unstructured":"6\uff09\u2003Iwai Y, Ozawa S, Ageishi T, et al. Feasibility of single-isocenter, multi-arc non-coplanar volumetric modulated arc therapy for multiple brain tumors using a linear accelerator with a 160-leaf multileaf collimator: a phantom study. J Radiat Res 2014; 55: 1015\u20131020.","key":"6","DOI":"10.1093\/jrr\/rru042"},{"doi-asserted-by":"crossref","unstructured":"7\uff09\u2003Kohutek ZA, Yamada Y, Chan TA, et al. Long-term risk of radionecrosis and imaging changes after stereotactic radiosurgery for brain metastases. J Neurooncol 2015; 125: 149\u2013156.","key":"7","DOI":"10.1007\/s11060-015-1881-3"},{"doi-asserted-by":"crossref","unstructured":"8\uff09\u2003Guckenberger M, Roesch J, Baier K, et al. Dosimetric consequences of translational and rotational errors in frame-less image-guided radiosurgery. Radiat Oncol 2012; 7: 63.","key":"8","DOI":"10.1186\/1748-717X-7-63"},{"doi-asserted-by":"crossref","unstructured":"9\uff09\u2003Meeks SL, Mercado CE, Popple RA, et al. Practical considerations for single isocenter LINAC radiosurgery of multiple brain metastases. Pract Radiat Oncol 2022; 12: 195\u2013199.","key":"9","DOI":"10.1016\/j.prro.2021.09.007"},{"doi-asserted-by":"crossref","unstructured":"10\uff09\u2003Faught AM, Trager M, Yin FF, et al. Re-examining TG-142 recommendations in light of modern techniques for linear accelerator based radiosurgery. Med Phys 2016; 43: 5437\u20135441.","key":"10","DOI":"10.1118\/1.4962471"},{"doi-asserted-by":"crossref","unstructured":"11\uff09\u2003Gao J, Liu X. Winston-Lutz-Gao test on the true beam STx linear accelerator. Int J Med Phys Clin Eng Radiat Oncol 2019; 8: 9\u201320.","key":"11","DOI":"10.4236\/ijmpcero.2019.81002"},{"doi-asserted-by":"crossref","unstructured":"12\uff09\u2003Peng JL, Liu C, Chen Y, et al. Dosimetric consequences of rotational setup errors with direct simulation in a treatment planning system for fractionated stereotactic radiotherapy. J Appl Clin Med Phys 2011; 12: 61\u201370.","key":"12","DOI":"10.1120\/jacmp.v12i3.3422"},{"doi-asserted-by":"crossref","unstructured":"13\uff09\u2003Prentou G, Pappas EP, Logothetis A, et al. Dosimetric impact of rotational errors on the quality of VMAT-SRS for multiple brain metastases: comparison between single- and two-isocenter treatment planning techniques. J Appl Clin Med Phys 2020; 21: 32\u201344.","key":"13","DOI":"10.1002\/acm2.12815"},{"doi-asserted-by":"crossref","unstructured":"14\uff09\u2003Gao J, Anand D. Off-iso Winston-Lutz test on seven linear accelerators. J Appl Clin Med Phys 2024; 25: e14470.","key":"14","DOI":"10.1002\/acm2.14470"},{"doi-asserted-by":"crossref","unstructured":"15\uff09\u2003Ono T, Kido T, Nakamura M, et al. Automatic measurement of beam-positioning accuracy at off-isocenter positions. J Appl Clin Med Phys 2023; 24: e13844.","key":"15","DOI":"10.1002\/acm2.13844"},{"doi-asserted-by":"crossref","unstructured":"16\uff09\u2003Klein EE, Hanley J, Bayouth J, et al. Task Group 142 report: Quality assurance of medical acceler. Med Phys 2009; 36: 4197\u20134212.","key":"16","DOI":"10.1118\/1.3190392"},{"doi-asserted-by":"crossref","unstructured":"17\uff09\u2003Hanley J, Dresser S, Simon W, et al. AAPM Task Group 198 report: An implementation guide for TG 142 quality assurance of medical accelerators. Med Phys 2021; 48: e830\u2013e885.","key":"17","DOI":"10.1002\/mp.14992"},{"doi-asserted-by":"crossref","unstructured":"18\uff09\u2003Kutcher GJ, Coia L, Gillin M, et al. Comprehensive QA for radiation oncology: report of AAPM Radiation Therapy Committee Task Group 40. Med Phys 1994; 21: 581\u2013618.","key":"18","DOI":"10.1118\/1.597316"},{"doi-asserted-by":"crossref","unstructured":"19\uff09\u2003Svensson GK, Baily NA, Loevinger R, et al. Physical aspects of quality assurance in radiation therapy (AAPM report No. 13). American Institute of Physics, 1984.","key":"19","DOI":"10.1016\/0360-3016(84)90449-8"},{"doi-asserted-by":"crossref","unstructured":"20\uff09\u2003Tsui SSW, Wu VWC, Cheung JSC. Comparison of dosimetric impact of intra-fractional setup discrepancy between multiple- and single-isocenter approaches in linac-based stereotactic radiotherapy of multiple brain metastases. J Appl Clin Med Phys 2022; 23: e13484.","key":"20","DOI":"10.1002\/acm2.13484"},{"doi-asserted-by":"crossref","unstructured":"21\uff09\u2003\u8fb0\u5df1\u5927\u4f5c\uff0c\u5bb6\u6c38\u6643\u529f\uff0c\u4e2d\u7530\u826f\u6210\uff0c\u4ed6\uff0e\u5b9a\u4f4d\u653e\u5c04\u7dda\u7167\u5c04\u306b\u304a\u3051\u308b\u653e\u5c04\u7dda\u30a2\u30a4\u30bd\u30bb\u30f3\u30bf\u306e\u5b9a\u91cf\u7684\u7ba1\u7406\u624b\u6cd5\u306e\u69cb\u7bc9\uff0e\u65e5\u653e\u6280\u5b66\u8a8c\u20022012; 68: 1333\u20131339.","key":"21","DOI":"10.6009\/jjrt.2012_JSRT_68.10.1333"},{"doi-asserted-by":"crossref","unstructured":"22\uff09\u2003Wack LJ, Exner F, Wegener S, et al. The impact of isocentric shifts on delivery accuracy during the irradiation of small cerebral targets\u2014quantification and possible corrections. J Appl Clin Med Phys 2020; 21: 56\u201364.","key":"22","DOI":"10.1002\/acm2.12854"},{"doi-asserted-by":"crossref","unstructured":"23\uff09\u2003Du W, Johnson JL, Jiang W, et al. On the selection of gantry and collimator angles for isocenter localization using Winston-Lutz tests. J Appl Clin Med Phys 2016; 17: 167\u2013178.","key":"23","DOI":"10.1120\/jacmp.v17i1.5792"},{"doi-asserted-by":"crossref","unstructured":"24\uff09\u2003Nakano H, Tanabe S, Utsunomiya S, et al. Effect of setup error in the single-isocenter technique on stereotactic radiosurgery for multiple brain metastases. J Appl Clin Med Phys 2020; 21: 155\u2013165.","key":"24","DOI":"10.1002\/acm2.13081"},{"doi-asserted-by":"crossref","unstructured":"25\uff09\u2003Pudsey LMM, Biasi G, Ralston A, et al. Detection of rotational errors in single-isocenter multiple-target radiosurgery: is a routine off-axis Winston\u2013Lutz test necessary? J Appl Clin Med Phys 2022; 23: e13665.","key":"25","DOI":"10.1002\/acm2.13665"}],"container-title":["Japanese Journal of Radiological Technology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/jjrt\/82\/2\/82_26-1566\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,12,6]],"date-time":"2025-12-06T03:37:24Z","timestamp":1764992244000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/jjrt\/82\/2\/82_26-1566\/_article\/-char\/ja\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026]]},"references-count":25,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.6009\/jjrt.26-1566","relation":{},"ISSN":["0369-4305","1881-4883"],"issn-type":[{"type":"print","value":"0369-4305"},{"type":"electronic","value":"1881-4883"}],"subject":[],"published":{"date-parts":[[2026]]},"article-number":"26-1566"}}