{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,6]],"date-time":"2025-12-06T04:28:23Z","timestamp":1764995303018,"version":"3.46.0"},"reference-count":22,"publisher":"Japanese Society of Radiological Technology","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Nippon Hoshasen Gijutsu Gakkai Zasshi","Jpn. J. Radiol. Technol."],"published-print":{"date-parts":[[2026]]},"DOI":"10.6009\/jjrt.26-1595","type":"journal-article","created":{"date-parts":[[2025,12,1]],"date-time":"2025-12-01T22:07:01Z","timestamp":1764626821000},"page":"n\/a","source":"Crossref","is-referenced-by-count":0,"title":["Monte Carlo Simulation Analysis of Beam Hardening and Iodine Contrast CT Values: Effects of Body Size and Tube Voltage","\u30e2\u30f3\u30c6\u30ab\u30eb\u30ed\u30b7\u30df\u30e5\u30ec\u30fc\u30b7\u30e7\u30f3\u306b\u3088\u308b\u7dda\u8cea\u786c\u5316\u3068\u9020\u5f71\u5264CT\u5024\u306e\u89e3\u6790\uff1a\u88ab\u5199\u4f53\u30b5\u30a4\u30ba\u30fb\u7ba1\u96fb\u5727\u306e\u5f71\u97ff"],"prefix":"10.6009","volume":"82","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7017-6472","authenticated-orcid":false,"given":"Yasushi","family":"Katsunuma","sequence":"first","affiliation":[{"name":"Department of Radiological Technology, Tokai University Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiroshi","family":"Honda","sequence":"additional","affiliation":[{"name":"Department of Radiological Technology, Tokai University Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"4040","reference":[{"key":"1","doi-asserted-by":"crossref","unstructured":"1\uff09\u2003Nakayama Y, Awai K, Funama Y, et al. Abdominal CT with low tube voltage: preliminary observations about radiation dose, contrast enhancement, image quality, and noise. Radiology 2005; 237: 945\u2013951.","DOI":"10.1148\/radiol.2373041655"},{"key":"2","doi-asserted-by":"crossref","unstructured":"2\uff09\u2003Kalva SP, Sahani DV, Hahn PF, et al. Using the K-edge to improve contrast conspicuity and to lower radiation dose with a 16-MDCT: a phantom and human study. J Comput Assist Tomogr 2006; 30: 391\u2013397.","DOI":"10.1097\/00004728-200605000-00008"},{"key":"3","doi-asserted-by":"crossref","unstructured":"3\uff09\u2003Cho ES, Chung TS, Kun Oh D, et al. Cerebral computed tomography angiography using a low tube voltage (80 kVp) and a moderate concentration of iodine contrast material: a quantitative and qualitative comparison with conventional computed tomography. Invest Radiol 2012; 47: 142\u2013147.","DOI":"10.1097\/RLI.0b013e31823076a4"},{"key":"4","doi-asserted-by":"crossref","unstructured":"4\uff09\u2003Szucs-Farkas Z, Verdun FR, von Allmen G, et al. Effect of X-ray tube parameters, iodine concentration, and patient size on image quality in pulmonary computed tomography angiography: a chest-phantom-study. Invest Radiol 2008; 43: 374\u2013381.","DOI":"10.1097\/RLI.0b013e3181690042"},{"key":"5","doi-asserted-by":"crossref","unstructured":"5\uff09\u2003Joseph PM, Spital RD. The effects of scatter in X-ray computed tomography. Med Phys 1982; 9: 464\u2013472.","DOI":"10.1118\/1.595111"},{"key":"6","doi-asserted-by":"crossref","unstructured":"6\uff09\u2003Goodsitt MM. Beam hardening errors in post-processing dual-energy quantitative computed tomography. Med Phys 1995; 22: 1039\u20131047.","DOI":"10.1118\/1.597590"},{"key":"7","unstructured":"7\uff09\u2003Gjesteby L, De Man B, Jin Y, et al. Metal artifact reduction in CT: where are we after four decades? IEEE Access 2018; 6: 58203\u201358221."},{"key":"8","doi-asserted-by":"crossref","unstructured":"8\uff09\u2003Verburg JM, Seco J. CT metal artifact reduction method correcting for beam hardening and missing projections. Phys Med Biol 2012; 57: 2803\u20132818.","DOI":"10.1088\/0031-9155\/57\/9\/2803"},{"key":"9","doi-asserted-by":"crossref","unstructured":"9\uff09\u2003Turner AC, Zhang D, Kim HJ, et al. A method to generate equivalent energy spectra and filtration models based on measurement for multidetector CT Monte Carlo dosimetry simulations. Med Phys 2009; 36: 2154\u20132164.","DOI":"10.1118\/1.3117683"},{"key":"10","doi-asserted-by":"crossref","unstructured":"10\uff09\u2003Kramer R, Cassola VF, Andrade ME, et al. Mathematical modelling of scanner-specific bowtie filters for Monte Carlo CT dosimetry. Phys Med Biol 2017; 62: 781\u2013809.","DOI":"10.1088\/1361-6560\/aa5343"},{"key":"11","doi-asserted-by":"crossref","unstructured":"11\uff09\u2003Sato T, Iwamoto Y, Hashimoto S, et al. Recent improvements of the Particle and Heavy Ion Transport code System - PHITS version 3.33. J Nucl Sci Technol 2024; 61: 127\u2013135.","DOI":"10.1080\/00223131.2023.2275736"},{"key":"12","unstructured":"12\uff09\u2003\u91cf\u5b50\u79d1\u5b66\u6280\u8853\u7814\u7a76\u958b\u767a\u6a5f\u69cb\uff0eWAZA-ARI v2. https:\/\/waza-ari.nirs.qst.go.jp\/ (Accessed 2025-05-30)."},{"key":"13","doi-asserted-by":"crossref","unstructured":"13\uff09\u2003Birch R, Marshall M. Computation of bremsstrahlung X-ray spectra and comparison with spectra measured with a Ge(Li) detector. Phys Med Biol 1979; 24: 505\u2013517.","DOI":"10.1088\/0031-9155\/24\/3\/002"},{"key":"14","unstructured":"14\uff09\u2003Cranley K, Gilmore BJ, Fogarty GWA, et al. Catalogue of diagnostic X-ray spectra and other data. Report No. 78. Institute of Physics and Engineering in Medicine, York, UK, 1997."},{"key":"15","unstructured":"15\uff09\u2003AAPM Task Group 111. Comprehensive methodology for the evaluation of radiation dose in X-ray computed tomography. American Association of Physicists in Medicine, College Park, MD, 2010."},{"key":"16","unstructured":"16\uff09\u2003\u7be0\u539f\u5e83\u884c\uff0c\u4e2d\u4e16\u53e4\u548c\u771f\uff0c\u9673\u6b23\u80e4\uff0c\u4ed6\uff0e\u30b3\u30fc\u30f3\u30d3\u30fc\u30e0CT\u753b\u50cf\u518d\u69cb\u6210\u306e\u57fa\u790e\uff0e\u533b\u7642\u79d1\u5b66\u793e\uff0c\u6771\u4eac\uff0c2013."},{"key":"17","unstructured":"17\uff09\u2003\u68ee\u4e00\u751f\uff0c\u8352\u6728\u529b\uff0c\u6751\u4e0a\u96c5\u898f\uff0eCT\u3068MRI\u306e\u539f\u7406\u3068\u6280\u8853\uff0e\u30b3\u30ed\u30ca\u793e\uff0c\u6771\u4eac\uff0c2010."},{"key":"18","doi-asserted-by":"crossref","unstructured":"18\uff09\u2003Marin D, Pratts-Emanuelli JJ, Mileto A, et al. Interdependencies of acquisition, detection, and reconstruction techniques on the accuracy of iodine quantification in varying patient sizes employing dual-energy CT. Eur Radiol 2015; 25: 679\u2013686.","DOI":"10.1007\/s00330-014-3447-8"},{"key":"19","doi-asserted-by":"crossref","unstructured":"19\uff09\u2003Duan X, Arbique G, Guild J, et al. Technical note: Quantitative accuracy evaluation for spectral images from a detector-based spectral CT scanner using an iodine phantom. Med Phys 2018; 45: 2048\u20132053.","DOI":"10.1002\/mp.12834"},{"key":"20","doi-asserted-by":"crossref","unstructured":"20\uff09\u2003Lifton JJ, Carmignato S. Simulating the influence of scatter and beam hardening in dimensional computed tomography. Meas Sci Technol 2017; 28: 104001.","DOI":"10.1088\/1361-6501\/aa80b2"},{"key":"21","doi-asserted-by":"crossref","unstructured":"21\uff09\u2003Zbijewski W, Beekman FJ. Efficient Monte Carlo based scatter artifact reduction in cone-beam micro-CT. IEEE Trans Med Imaging 2006; 25: 817\u2013827.","DOI":"10.1109\/TMI.2006.872328"},{"key":"22","doi-asserted-by":"crossref","unstructured":"22\uff09\u2003Jarry G, Graham SA, Moseley DJ, et al. Characterization of scattered radiation in kV CBCT images using Monte Carlo simulations. Med Phys 2006; 33: 4320\u20134329.","DOI":"10.1118\/1.2358324"}],"container-title":["Japanese Journal of Radiological Technology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/jjrt\/82\/1\/82_26-1595\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,12,6]],"date-time":"2025-12-06T03:37:12Z","timestamp":1764992232000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/jjrt\/82\/1\/82_26-1595\/_article\/-char\/ja\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026]]},"references-count":22,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.6009\/jjrt.26-1595","relation":{},"ISSN":["0369-4305","1881-4883"],"issn-type":[{"type":"print","value":"0369-4305"},{"type":"electronic","value":"1881-4883"}],"subject":[],"published":{"date-parts":[[2026]]},"article-number":"26-1595"}}