{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,17]],"date-time":"2026-10-17T04:41:52Z","timestamp":1792212112740,"version":"4.4.0"},"reference-count":29,"publisher":"Japanese Society of Radiological Technology","issue":"11","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Nippon Hoshasen Gijutsu Gakkai Zasshi","Jpn. J. Radiol. Technol."],"published-print":{"date-parts":[[2026]]},"DOI":"10.6009\/jjrt.26-1696","type":"journal-article","created":{"date-parts":[[2026,10,16]],"date-time":"2026-10-16T22:11:53Z","timestamp":1792188713000},"page":"n\/a","source":"Crossref","is-referenced-by-count":0,"title":["Impact of Hybrid Iterative Reconstruction Combined with a Sharpening Filter on Coronary Artery Stent Profile Characteristics and Visual Assessment in Coronary CT Angiography: A Phantom Study","\u51a0\u52d5\u8108CT-angiography\u306b\u304a\u3051\u308b\u9bae\u92ed\u5316\u30d5\u30a3\u30eb\u30bf\u3092\u4f75\u7528\u3057\u305f\u9010\u6b21\u8fd1\u4f3c\u5fdc\u7528\u518d\u69cb\u6210\u6cd5\u304c\u51a0\u52d5\u8108\u30b9\u30c6\u30f3\u30c8\u306e\u30d7\u30ed\u30d5\u30a1\u30a4\u30eb\u7279\u6027\u304a\u3088\u3073\u8996\u899a\u8a55\u4fa1\u306b\u53ca\u307c\u3059\u5f71\u97ff\uff1a\u30d5\u30a1\u30f3\u30c8\u30e0\u7814\u7a76"],"prefix":"10.6009","volume":"82","author":[{"given":"Mizuki","family":"Kakisako","sequence":"first","affiliation":[{"name":"Department of Radiology, JA Oita Koseiren Tsurumi Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ryo","family":"Watanabe","sequence":"additional","affiliation":[{"name":"Department of Radiological Technology, Faculty of Fukuoka Medical Technology, Teikyo University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Makoto","family":"Fujiwara","sequence":"additional","affiliation":[{"name":"Department of Radiology, JA Oita Koseiren Tsurumi Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kenta","family":"Maruyama","sequence":"additional","affiliation":[{"name":"Department of Radiology, JA Oita Koseiren Tsurumi Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"4040","reference":[{"key":"1","doi-asserted-by":"crossref","unstructured":"1\uff09\u2003Shlofmitz E, Iantorno M, Waksman R. Restenosis of drug-eluting stents: a new classification system based on disease mechanism to guide treatment and State-of-the-Art review. Circ Cardiovasc Interv 2019; 12: e007023.","DOI":"10.1161\/CIRCINTERVENTIONS.118.007023"},{"key":"2","doi-asserted-by":"crossref","unstructured":"2\uff09\u2003Ehara M, Kawai M, Surmely JF, et al. Diagnostic accuracy of coronary in-stent restenosis using 64-slice computed tomography: comparison with invasive coronary angiography. J Am Coll Cardiol 2007; 49: 951\u2013959.","DOI":"10.1016\/j.jacc.2006.10.065"},{"key":"3","unstructured":"3\uff09\u2003\u65e5\u672c\u5faa\u74b0\u5668\u5b66\u4f1a\uff0c\u65e5\u672c\u533b\u5b66\u653e\u5c04\u7dda\u5b66\u4f1a\uff0c\u65e5\u672c\u6838\u533b\u5b66\u4f1a\uff0c\u4ed6\uff0e\u6162\u6027\u51a0\u52d5\u8108\u75be\u60a3\u8a3a\u65ad\u30ac\u30a4\u30c9\u30e9\u30a4\u30f3\uff082018\u5e74\u6539\u8a02\u7248\uff09\uff0e"},{"key":"4","doi-asserted-by":"crossref","unstructured":"4\uff09\u2003Nikolaou K, Knez A, Rist C, et al. Accuracy of 64-MDCT in the diagnosis of ischemic heart disease. AJR Am J Roentgenol 2006; 187: 111\u2013117.","DOI":"10.2214\/AJR.05.1697"},{"key":"5","doi-asserted-by":"crossref","unstructured":"5\uff09\u2003Cademartiri F, Schuijf JD, Pugliese F, et al. Usefulness of 64-slice multislice computed tomography coronary angiography to assess in-stent restenosis. J Am Coll Cardiol 2007; 49: 2204\u20132210.","DOI":"10.1016\/j.jacc.2007.02.045"},{"key":"6","doi-asserted-by":"crossref","unstructured":"6\uff09\u2003Gaspar T, Halon DA, Lewis BS, et al. Diagnosis of coronary in-stent restenosis with multidetector row spiral computed tomography. J Am Coll Cardiol 2005; 46: 1573\u20131579.","DOI":"10.1016\/j.jacc.2005.07.049"},{"key":"7","doi-asserted-by":"crossref","unstructured":"7\uff09\u2003\u6e0b\u8c37\u5e78\u559c\uff0c\u85e4\u539f\u653f\u96c4\uff0c\u6c34\u53e3\u96c4\u6cbb\uff0e\u9bae\u92ed\u5ea6\u5411\u4e0a\u3092\u76ee\u7684\u3068\u3057\u305fzero cross point\u753b\u50cf\u306b\u3088\u308b\u51a0\u52d5\u8108\u30b9\u30c6\u30f3\u30c8\u5185\u8154\u518d\u69cb\u6210\u6cd5\uff0e\u65e5\u653e\u6280\u5b66\u8a8c\u20022008; 64: 325\u2013334.","DOI":"10.6009\/jjrt.64.325"},{"key":"8","doi-asserted-by":"crossref","unstructured":"8\uff09\u2003Mahnken AH. CT imaging of coronary stents: past, present, and future. ISRN Cardiol 2012; 2012: 139823.","DOI":"10.5402\/2012\/139823"},{"key":"9","unstructured":"9\uff09\u2003\u9152\u5411\u5065\u4e8c\uff0c\u5409\u7530\u6731\u91cc\uff0c\u539f\u5b5d\u5247\uff0e\u8d85\u89e3\u50cfdeep learning reconstruction\u3092\u7528\u3044\u305f\u51a0\u52d5\u8108\u30b9\u30c6\u30f3\u30c8\u63cf\u51fa\u80fd\u306e\u8a55\u4fa1\uff0e\u65e5CT\u6280\u4f1a\u8a8c\u20022023; 11: 5\u20139."},{"key":"10","doi-asserted-by":"crossref","unstructured":"10\uff09\u2003Nagayama Y, Emoto T, Hayashi H, et al. Coronary stent evaluation by CTA: image quality comparison between super-resolution deep learning reconstruction and other reconstruction algorithms. AJR Am J Roentgenol 2023; 221: 599\u2013610.","DOI":"10.2214\/AJR.23.29506"},{"key":"11","doi-asserted-by":"crossref","unstructured":"11\uff09\u2003Orii M, Sone M, Osaki T, et al. Super-resolution deep learning reconstruction at coronary computed tomography angiography to evaluate the coronary arteries and in-stent lumen: an initial experience. BMC Med Imaging 2023; 23: 171.","DOI":"10.1186\/s12880-023-01139-7"},{"key":"12","doi-asserted-by":"crossref","unstructured":"12\uff09\u2003Oda S, Utsunomiya D, Funama Y, et al. Improved coronary in-stent visualization using a combined high-resolution kernel and a hybrid iterative reconstruction technique at 256-slice cardiac CT-Pilot study. Eur J Radiol 2013; 82: 288\u2013295.","DOI":"10.1016\/j.ejrad.2012.11.003"},{"key":"13","doi-asserted-by":"crossref","unstructured":"13\uff09\u2003Tan S, Soulez G, Diez Martinez P, et al. Coronary stent artifact reduction with an edge-enhancing reconstruction kernel - a prospective cross-sectional study with 256-slice CT. PLoS One 2016; 11: e0154292.","DOI":"10.1371\/journal.pone.0154292"},{"key":"14","doi-asserted-by":"crossref","unstructured":"14\uff09\u2003Hong C, Chrysant GS, Woodard PK, et al. Coronary artery stent patency assessed with in-stent contrast enhancement measured at multi-detector row CT angiography: initial experience. Radiology 2004; 233: 286\u2013291.","DOI":"10.1148\/radiol.2331031564"},{"key":"15","doi-asserted-by":"crossref","unstructured":"15\uff09\u2003Steen H, Andr\u00e9 F, Korosoglou G, et al. In vitro evaluation of 56 coronary artery stents by 256-slice multi-detector coronary CT. Eur J Radiol 2011; 80: 143\u2013150.","DOI":"10.1016\/j.ejrad.2010.08.007"},{"key":"16","doi-asserted-by":"crossref","unstructured":"16\uff09\u2003\u77f3\u7530\u9686\u884c\uff0e2.\u753b\u50cf\u51e6\u7406\u30fb\u7279\u5fb4\u91cf\u5206\u6790\u304a\u3088\u3073\u6027\u80fd\u8a55\u4fa1\u306e\u57fa\u790e\uff0e\u65e5\u653e\u6280\u5b66\u8a8c\u20022000; 56: 363\u2013369.","DOI":"10.6009\/jjrt.KJ00001356833"},{"key":"17","unstructured":"17\uff09\u2003Al-Ameen Z, Sulong G, Johar MGM, et al. Reducing the Gaussian blur artifact from CT medical images by employing a combination of sharpening filters and iterative deblurring algorithms. J Theor Appl Inf Technol 2012; 46: 31\u201336."},{"key":"18","unstructured":"18\uff09\u2003\u539f\u79c0\u525b\uff0c\u677e\u6fa4\u6d69\u7d00\uff0c\u963f\u90e8\u614e\u53f8\uff0c\u4ed6\uff0eX\u7ddaCT\u753b\u50cf\u306b\u304a\u3051\u308b\u6025\u6027\u671f\u8133\u6897\u585e\u691c\u51fa\u306e\u305f\u3081\u306e\u30de\u30eb\u30c1\u5468\u6ce2\u6570\u51e6\u7406\u306e\u691c\u8a0e\uff0e\u65e5\u4fdd\u5065\u79d1\u4f1a\u8a8c\u20022016; 19: 140\u2013147."},{"key":"19","doi-asserted-by":"crossref","unstructured":"19\uff09\u2003Ohkubo M, Wada S, Kayugawa A, et al. Image filtering as an alternative to the application of a different reconstruction kernel in CT imaging: feasibility study in lung cancer screening. Med Phys 2011; 38: 3915\u20133923.","DOI":"10.1118\/1.3590363"},{"key":"20","doi-asserted-by":"crossref","unstructured":"20\uff09\u2003\u732a\u53c8\u8056\u7f8e\uff0c\u674e\u9394\u7bc4\uff0c\u8521\u7be4\u5100\uff0c\u4ed6\uff0e\u982d\u90e8CTA\u753b\u50cf\u306b\u304a\u3051\u308b\u8133\u8840\u7ba1\u9818\u57df\u306e\u81ea\u52d5\u62bd\u51fa\u306e\u8a66\u307f\uff0e\u65e5\u653e\u6280\u5b66\u8a8c\u20022004; 60: 1325\u20131331.","DOI":"10.6009\/jjrt.KJ00003174600"},{"key":"21","doi-asserted-by":"crossref","unstructured":"21\uff09\u2003Eisentopf J, Achenbach S, Ulzheimer S, et al. Low-dose dual-source CT angiography with iterative reconstruction for coronary artery stent evaluation. JACC Cardiovasc Imaging 2013; 6: 458\u2013465.","DOI":"10.1016\/j.jcmg.2012.10.023"},{"key":"22","doi-asserted-by":"crossref","unstructured":"22\uff09\u2003Ebersberger U, Tricarico F, Schoepf UJ, et al. CT evaluation of coronary artery stents with iterative image reconstruction: improvements in image quality and potential for radiation dose reduction. Eur Radiol 2013; 23: 125\u2013132.","DOI":"10.1007\/s00330-012-2580-5"},{"key":"23","doi-asserted-by":"crossref","unstructured":"23\uff09\u2003Richard S, Husarik DB, Yadava G, et al. Towards task-based assessment of CT performance: system and object MTF across different reconstruction algorithms. Med Phys 2012; 39: 4115\u20134122.","DOI":"10.1118\/1.4725171"},{"key":"24","unstructured":"24\uff09\u2003Abramoff MD, Magelhaes PJ, Ram SJ. Image processing with ImageJ. Biophoton Int 2004; 11: 36\u201342."},{"key":"25","unstructured":"25\uff09\u2003Ichikawa K, Hara T, Ohashi K, et al. CT measure, 2012\u20132014. http:\/\/www.jsct-tech.org\/\uff082023\u5e744\u67083\u65e5\u78ba\u8a8d\uff09\uff0e"},{"key":"26","doi-asserted-by":"crossref","unstructured":"26\uff09\u2003Takenaga T, Katsuragawa S, Goto M, et al. Modulation transfer function measurement of CT images by use of a circular edge method with a logistic curve-fitting technique. Radiol Phys Technol 2015; 8: 53\u201359.","DOI":"10.1007\/s12194-014-0286-x"},{"key":"27","doi-asserted-by":"crossref","unstructured":"27\uff09\u2003\u4e2d\u524d\u5149\u5f18\uff0e\u7d71\u8a08\u7684\u5b98\u80fd\u691c\u67fb\u6cd5\u306e\u7406\u8ad6\u3068\u653e\u5c04\u7dda\u6280\u8853\u79d1\u5b66\u3078\u306e\u5fdc\u7528\u2014Scheff\u00e9\uff08\u30b7\u30a7\u30c3\u30d5\u30a7\uff09\u306e\u4e00\u5bfe\u6bd4\u8f03\u6cd5\u3092\u4e2d\u5fc3\u306b\u2014\uff0e\u65e5\u653e\u6280\u5b66\u8a8c\u20022010; 66: 1502\u20131507.","DOI":"10.6009\/jjrt.66.1502"},{"key":"28","doi-asserted-by":"crossref","unstructured":"28\uff09\u2003Yamamoto H, Kihara Y, Kitagawa T, et al. Coronary plaque characteristics in computed tomography and 2-year outcomes: the PREDICT study. J Cardiovasc Comput Tomogr 2018; 12: 436\u2013443.","DOI":"10.1016\/j.jcct.2018.07.001"},{"key":"29","doi-asserted-by":"crossref","unstructured":"29\uff09\u2003Motoyama S, Kondo T, Sarai M, et al. Multislice computed tomographic characteristics of coronary lesions in acute coronary syndromes. J Am Coll Cardiol 2007; 50: 319\u2013326.","DOI":"10.1016\/j.jacc.2007.03.044"}],"container-title":["Japanese Journal of Radiological Technology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/jjrt\/82\/11\/82_26-1696\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,17]],"date-time":"2026-10-17T04:00:47Z","timestamp":1792209647000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/jjrt\/82\/11\/82_26-1696\/_article\/-char\/ja\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026]]},"references-count":29,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.6009\/jjrt.26-1696","relation":{},"ISSN":["0369-4305","1881-4883"],"issn-type":[{"value":"0369-4305","type":"print"},{"value":"1881-4883","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026]]},"article-number":"26-1696"}}