{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,22]],"date-time":"2026-08-22T04:25:25Z","timestamp":1787372725977,"version":"build-2736575974"},"reference-count":20,"publisher":"Japanese Society of Radiological Technology","issue":"10","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Nippon Hoshasen Gijutsu Gakkai Zasshi","Jpn. J. Radiol. Technol."],"published-print":{"date-parts":[[2026]]},"DOI":"10.6009\/jjrt.26-1707","type":"journal-article","created":{"date-parts":[[2026,8,19]],"date-time":"2026-08-19T22:11:09Z","timestamp":1787177469000},"page":"n\/a","source":"Crossref","is-referenced-by-count":0,"title":["A Bayesian Approach to ADC-to-Dose Conversion in Radiochromic Film Dosimetry","\u30d9\u30a4\u30ba\u63a8\u5b9a\u3092\u7528\u3044\u305f\u30e9\u30b8\u30aa\u30af\u30ed\u30df\u30c3\u30af\u30d5\u30a3\u30eb\u30e0\u306eADC\u5024\u2013\u7dda\u91cf\u5909\u63db\u6cd5"],"prefix":"10.6009","volume":"82","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5337-7563","authenticated-orcid":false,"given":"Yuki","family":"Tanimoto","sequence":"first","affiliation":[{"name":"Department of Radiology, NHO Iwakuni Clinical Center"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2702-5235","authenticated-orcid":false,"given":"Kohei","family":"Sugimoto","sequence":"additional","affiliation":[{"name":"Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masahide","family":"Tamori","sequence":"additional","affiliation":[{"name":"Department of Radiology, NHO Kure Medical Center and Chugoku Cancer Center"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Miho","family":"Yatsuki","sequence":"additional","affiliation":[{"name":"Department of Radiology, NHO Kure Medical Center and Chugoku Cancer Center"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shohei","family":"Yoshida","sequence":"additional","affiliation":[{"name":"Department of Radiology, NHO Kure Medical Center and Chugoku Cancer Center"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kazuma","family":"Sugahara","sequence":"additional","affiliation":[{"name":"Department of Radiology, NHO Kure Medical Center and Chugoku Cancer Center"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8667-6209","authenticated-orcid":false,"given":"Masataka","family":"Oita","sequence":"additional","affiliation":[{"name":"Faculty of Interdisciplinary Science and Engineering in Health Systems, Okayama University"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"4040","reference":[{"key":"1","doi-asserted-by":"crossref","unstructured":"1\uff09\u2003Ezzell GA, Galvin JM, Low D, et al. Guidance document on delivery, treatment planning, and clinical implementation of IMRT: report of the IMRT subcommittee of the AAPM Radiation Therapy Committee. Med Phys 2003; 30: 2089\u20132115.","DOI":"10.1118\/1.1591194"},{"key":"2","doi-asserted-by":"crossref","unstructured":"2\uff09\u2003Ezzell GA, Burmeister JW, Dogan N, et al. IMRT commissioning: multiple institution planning and dosimetry comparisons, a report from AAPM Task Group 119. Med Phys 2009; 36: 5359\u20135373.","DOI":"10.1118\/1.3238104"},{"key":"3","doi-asserted-by":"crossref","unstructured":"3\uff09\u2003Moran JM, Dempsey M, Eisbruch A, et al. Safety considerations for IMRT: executive summary. Med Phys 2011; 38: 5067\u20135072.","DOI":"10.1118\/1.3600524"},{"key":"4","doi-asserted-by":"crossref","unstructured":"4\uff09\u2003Hartford AC, Galvin JM, Beyer DC, et al. American College of Radiology (ACR) and American Society for Radiation Oncology (ASTRO) practice guideline for intensity-modulated radiation therapy (IMRT). Am J Clin Oncol 2012; 35: 612\u2013617.","DOI":"10.1097\/COC.0b013e31826e0515"},{"key":"5","unstructured":"5\uff09\u2003\u30ac\u30d5\u30af\u30ed\u30df\u30c3\u30af\u30d5\u30a3\u30eb\u30e0\u7814\u7a76\u4f1a\u7de8\uff0e2. \u30ac\u30d5\u30af\u30ed\u30df\u30c3\u30af\u30d5\u30a3\u30eb\u30e0\u3067\u306e\u7dda\u91cf\u5206\u5e03\u6e2c\u5b9a\u624b\u9806\uff0e\u653e\u5c04\u7dda\u6cbb\u7642\u5206\u91ce\u3067\u306eGAFCHROMIC HANDBOOK\u7dda\u91cf\u5206\u5e03\u3092\u6e2c\u5b9a\u3059\u308b\u5834\u5408\u306e\u53d6\u308a\u6271\u3044\u306b\u3064\u3044\u3066\uff0e\u682a\u5f0f\u4f1a\u793e\u30d9\u30ea\u30bf\u30b9\uff0c\u6771\u4eac\uff0c2022; 20\u201330."},{"key":"6","doi-asserted-by":"crossref","unstructured":"6\uff09\u2003Childress NL, Dong L, Rosen II. Rapid radiographic film calibration for IMRT verification using automated MLC fields. Med Phys 2002; 29: 2384\u20132390.","DOI":"10.1118\/1.1509441"},{"key":"7","doi-asserted-by":"crossref","unstructured":"7\uff09\u2003Kulasekere R, Moran JM, Fraass BA, et al. Accuracy of rapid radiographic film calibration for intensity-modulated radiation therapy verification. J Appl Clin Med Phys 2006; 7: 86\u201395.","DOI":"10.1120\/jacmp.v7i2.2202"},{"key":"8","doi-asserted-by":"crossref","unstructured":"8\uff09\u2003Yan Y, Papanikolaou N, Weng X, et al. Fast radiographic film calibration procedure for helical tomotherapy intensity-modulated radiation therapy dose verification. Med Phys 2005; 32: 1566\u20131570.","DOI":"10.1118\/1.1924327"},{"key":"9","doi-asserted-by":"crossref","unstructured":"9\uff09\u2003Miura H, Ozawa S, Hosono F, et al. Radiochromic EBT-XD film: dosimetry characterization in high-dose volumetric-modulated arc therapy. J Appl Clin Med Phys 2016; 17: 312\u2013322.","DOI":"10.1120\/jacmp.v17i6.6281"},{"key":"10","doi-asserted-by":"crossref","unstructured":"10\uff09\u2003Palmer AL, Bradley DA, Nisbet A, et al. Evaluation and mitigation of potential errors in radiochromic film dosimetry due to film curvature at scanning. J Appl Clin Med Phys 2015; 16: 425\u2013431.","DOI":"10.1120\/jacmp.v16i2.5141"},{"key":"11","doi-asserted-by":"crossref","unstructured":"11\uff09\u2003Miura H, Ozawa S, Okazue T, et al. Characterization of scanning orientation and lateral response artifact for EBT4 radiochromic film. J Appl Clin Med Phys 2023; 24: e13992.","DOI":"10.1002\/acm2.13992"},{"key":"12","doi-asserted-by":"crossref","unstructured":"12\uff09\u2003Pai S, Das IJ, Dempsey JF, et al. TG-69: radiographic film for megavoltage beam dosimetry. Med Phys 2007; 34: 2228\u20132258.","DOI":"10.1118\/1.2736779"},{"key":"13","unstructured":"13\uff09\u2003\u4e2d\u6751\u5149\u5b8f\uff0c\u4f0a\u826f\u7686\u62d3\uff0c\u9ad8\u5bae\u5927\u7fa9\uff0c\u4ed6\uff0e\u5f37\u5ea6\u5909\u8abf\u653e\u5c04\u7dda\u6cbb\u7642\u306b\u304a\u3051\u308b\u7dda\u91cf\u691c\u8a3c\u306e\u6a19\u6e96\u5316\u306b\u5411\u3051\u305f\u8abf\u67fb\u7814\u7a76\uff0e\u533b\u7269\u7406 2014; 34: 208\u2013218."},{"key":"14","doi-asserted-by":"crossref","unstructured":"14\uff09\u2003Sugimoto K, Fujiwara Y, Oita M, et al. Estimating the differences between inter-operator contrast enhancement in cerebral CT angiography. Med Phys 2023; 50: 7934\u20137945.","DOI":"10.1002\/mp.16549"},{"key":"15","doi-asserted-by":"crossref","unstructured":"15\uff09\u2003Wang Q, Wang R, Liu J, et al. High-dimensional automated radiation therapy treatment planning via Bayesian optimization. Med Phys 2023; 50: 3773\u20133787.","DOI":"10.1002\/mp.16289"},{"key":"16","doi-asserted-by":"crossref","unstructured":"16\uff09\u2003Xiong X, Zeng B, Zhang S, et al. Which type of exercise during radiation therapy is optimal to improve fatigue and quality of life in men with prostate cancer? A Bayesian network analysis. Eur Urol Open Sci 2022; 43: 74\u201386.","DOI":"10.1016\/j.euros.2022.07.008"},{"key":"17","doi-asserted-by":"crossref","unstructured":"17\uff09\u2003Gelman A, Carlin JB, Stern HS, et al. Bayesian Data Analysis, 2nd ed. Chapman and Hall\/CRC, New York, 2003.","DOI":"10.1201\/9780429258480"},{"key":"18","doi-asserted-by":"crossref","unstructured":"18\uff09\u2003Devic S, Seuntjens J, Sham E, et al. Precise radiochromic film dosimetry using a flat-bed document scanner. Med Phys 2005; 32: 2245\u20132253.","DOI":"10.1118\/1.1929253"},{"key":"19","doi-asserted-by":"crossref","unstructured":"19\uff09\u2003Lewis D, Micke A, Yu X, et al. An efficient protocol for radiochromic film dosimetry combining calibration and measurement in a single scan. Med Phys 2012; 39: 6339\u20136350.","DOI":"10.1118\/1.4754797"},{"key":"20","doi-asserted-by":"crossref","unstructured":"20\uff09\u2003Girard F, Bouchard H, Lacroix F, et al. Reference dosimetry using radiochromic film. J Appl Clin Med Phys 2012; 13: 3994.","DOI":"10.1120\/jacmp.v13i6.3994"}],"container-title":["Japanese Journal of Radiological Technology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/jjrt\/82\/10\/82_26-1707\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,22]],"date-time":"2026-08-22T03:52:16Z","timestamp":1787370736000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/jjrt\/82\/10\/82_26-1707\/_article\/-char\/ja\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026]]},"references-count":20,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.6009\/jjrt.26-1707","relation":{},"ISSN":["0369-4305","1881-4883"],"issn-type":[{"value":"0369-4305","type":"print"},{"value":"1881-4883","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026]]},"article-number":"26-1707"}}