{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,11]],"date-time":"2026-07-11T04:12:50Z","timestamp":1783743170937,"version":"3.55.0"},"reference-count":11,"publisher":"Japanese Society of Radiological Technology","issue":"7","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Nippon Hoshasen Gijutsu Gakkai Zasshi","Jpn. J. Radiol. Technol."],"published-print":{"date-parts":[[2010,7,20]]},"DOI":"10.6009\/jjrt.66.749","type":"journal-article","created":{"date-parts":[[2012,1,13]],"date-time":"2012-01-13T00:11:08Z","timestamp":1326413468000},"page":"749-757","source":"Crossref","is-referenced-by-count":1,"title":["Comparison MR Cholangiopancreatography with 3D-Fast Recovery Fast Spin Echo in Several Different Slice Thicknesses","3D-Fast Recovery Fast Spin Echo\u6cd5\u3092\u7528\u3044\u305f MR cholangiopancreatography\u306b\u304a\u3051\u308b\u6700\u9069\u30b9\u30e9\u30a4\u30b9\u539a\u306e\u691c\u8a0e"],"prefix":"10.6009","volume":"66","author":[{"given":"Hiroshi","family":"Ikenoue","sequence":"first","affiliation":[{"name":"Nagoya Kyoritsu Hospital"},{"name":"Graduate School of the University of Nagoya"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shigeki","family":"Ito","sequence":"additional","affiliation":[{"name":"Hirokoji Clinic"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masami","family":"Yamada","sequence":"additional","affiliation":[{"name":"Nagoya Kyoritsu Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yukinori","family":"Takikawa","sequence":"additional","affiliation":[{"name":"Nagoya Kyoritsu Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Osamu","family":"Yamamuro","sequence":"additional","affiliation":[{"name":"Nagoya Radiological Diagnosis Foundation"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"4040","reference":[{"key":"1","doi-asserted-by":"crossref","unstructured":"1) Morimoto K, Shimoi M, Shirakawa T, et al. Biliary Obstruction: Evaluation with Three-dimensional MR Cholangiography. Radiology 1992; 183(2): 578-580.","DOI":"10.1148\/radiology.183.2.1561373"},{"key":"2","doi-asserted-by":"crossref","unstructured":"2) Takehara Y, Ichijo K, Tooyama N, et al. Breath-Hold MR Cholangiopancreatography with a Long-Echo-Train Fast Spin-Echo Sequence and a Surface Coil in Choronic Pancreatitis. Radiology 1994; 192(1): 73-78.","DOI":"10.1148\/radiology.192.1.8208969"},{"key":"3","doi-asserted-by":"crossref","unstructured":"3) Soto JA, Barish MA, Yucel EK, et al. Pancreatic duct: MR cholangiopancreatography with a three-dimensional fast spin-echo technique. Radiology 1995; 196(2): 459-464.","DOI":"10.1148\/radiology.196.2.7617861"},{"key":"4","doi-asserted-by":"crossref","unstructured":"4) Bret PM, Reinhold C, Taourel P, et al. Pancreas divisum: evaluation with MR cholangiopancreatography. Radiology 1996; 199(1): 99-103.","DOI":"10.1148\/radiology.199.1.8633179"},{"key":"5","doi-asserted-by":"crossref","unstructured":"5) Ernst O, Calvo M, Sergent G, et al. Breath-hold MR cholangiopancreatography using a HASTE sequence: comparison of single-slice and multislice acquisition techniques. AJR 1997; 169(5): 1304-1306.","DOI":"10.2214\/ajr.169.5.9353446"},{"key":"6","doi-asserted-by":"crossref","unstructured":"6) Yamashita Y, Abe Y, Tang Y, et al. In vitro and clinical studies of image acquisition in breath-hold MR cholangiopancreatography: single-shot projection technique versus multislice technique. AJR 1997; 168(6): 1449-1454.","DOI":"10.2214\/ajr.168.6.9168706"},{"key":"7","doi-asserted-by":"crossref","unstructured":"7) Sodickson A, Mortele KJ, Barish MA, et al. Three-dimensional fast-recovery fast spin-echo MRCP: comparison with two-dimensional single-shot fast spin-echo techniques. Radiology 2006; 238(2): 549-559.","DOI":"10.1148\/radiol.2382032065"},{"key":"8","doi-asserted-by":"crossref","unstructured":"8) Zhang J, Israel GM, Hecht EM, et al. Isotropic 3D T2-weighted MR cholangiopancreatography with prallel imaging: feasibility study. AJR 2006; 187(6): 1564-1570.","DOI":"10.2214\/AJR.05.1032"},{"key":"9","doi-asserted-by":"crossref","unstructured":"9) Choi JY, Lee JM, Lee JY, et al. Navigator-triggered isotropic three-dimensional magnetic resonance cholangiopancreatography in the diagnosis of malignant biliary obstructions: comparison with direct cholangiography. J Magn Reson Imaging 2008; 27(1): 94-101.","DOI":"10.1002\/jmri.21038"},{"key":"10","doi-asserted-by":"crossref","unstructured":"10) Park DH, Kim MH, Lee SK, et al. Can MRCP replace the diagnostic role of ERCP for patient with choledochal cyst? Gastrointest Endosc 2005; 62(3): 306-366.","DOI":"10.1016\/j.gie.2005.04.026"},{"key":"11","doi-asserted-by":"crossref","unstructured":"11) Scheiman JM, Carlos RC, Barnett JL, et al. Can endoscopic ultrasound or magnetic resonance cholangiopancreatography replace ERCP in patients with suspected biliary disease? A prospective trial and cost analysis. Am J Gastroenterol 2001; 96(10): 2900-2904.","DOI":"10.1016\/S0002-9270(01)02807-6"}],"container-title":["Japanese Journal of Radiological Technology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/jjrt\/66\/7\/66_7_749\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,11]],"date-time":"2026-07-11T03:46:52Z","timestamp":1783741612000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/jjrt\/66\/7\/66_7_749\/_article\/-char\/ja\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,7,20]]},"references-count":11,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2010]]}},"URL":"https:\/\/doi.org\/10.6009\/jjrt.66.749","relation":{},"ISSN":["0369-4305","1881-4883"],"issn-type":[{"value":"0369-4305","type":"print"},{"value":"1881-4883","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,7,20]]}}}