{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,11]],"date-time":"2026-07-11T14:38:32Z","timestamp":1783780712810,"version":"3.55.0"},"reference-count":14,"publisher":"Japanese Society of Radiological Technology","issue":"12","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Nippon Hoshasen Gijutsu Gakkai Zasshi","Jpn. J. Radiol. Technol."],"published-print":{"date-parts":[[2005]]},"DOI":"10.6009\/jjrt.kj00004022980","type":"journal-article","created":{"date-parts":[[2017,7,15]],"date-time":"2017-07-15T19:23:45Z","timestamp":1500146625000},"page":"1675-1680","source":"Crossref","is-referenced-by-count":5,"title":["Experimental Comparison of Flat-panel Detector Performance for Direct and Indirect Systems"],"prefix":"10.6009","volume":"61","author":[{"given":"TSUTOMU","family":"GOMI","sequence":"first","affiliation":[{"name":"Department of Radiology, Shinshu University Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"JUN","family":"MIYAGAWA","sequence":"additional","affiliation":[{"name":"Department of Radiology, Shinshu University Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"HIROSHI","family":"HIRANO","sequence":"additional","affiliation":[{"name":"Department of Radiology, Shinshu University Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"4040","reference":[{"key":"1","doi-asserted-by":"crossref","unstructured":"1) YAFFEE MJ. X-ray detectors for digital radiography. Phys Med Biol. (1997) vol.42, p.1-39.","DOI":"10.1088\/0031-9155\/42\/1\/001"},{"key":"2","doi-asserted-by":"crossref","unstructured":"2) LEE DL. Improved imaging performance of a 14\u00d717-inch digital radiography system using a Se\/TFT detector. Proc. SPIE. (1998) vol.3336, p.14-23.","DOI":"10.1117\/12.317017"},{"key":"3","doi-asserted-by":"crossref","unstructured":"3) ZHAO W. Digital radiology using active matrix readout of amorphous selenium : construction and evaluation of a prototype real-time detector. Med Phys. (1997) vol.24, p.1834-1843.","DOI":"10.1118\/1.598098"},{"key":"4","unstructured":"4) SIEWERDESN JH. Empirical and theoretical investigation of the noise performance of indirect detection, active matrix flat-panel imagers (AMFPIs) for diagnostic radiology. Med Phys. (1997) vol.24, p.71-89."},{"key":"5","unstructured":"5) CHAUSSAT C. New CsI\/a-Si 17&quot;\u00d717&quot; x-ray flat-panel detector provides superior directivity and immediate direct digital output for general radiography systems. Proc. SPIE. (1998) vol.3336, p.45-56."},{"key":"6","doi-asserted-by":"crossref","unstructured":"6) COLBETH RE. Characterization of a third-generation multimode sensor panel. Proc. SPIE. (1999) vol.3659, p.491-500.","DOI":"10.1117\/12.349527"},{"key":"7","doi-asserted-by":"crossref","unstructured":"7) GRANFORS PR. Performance of a 41\u00d741 cm^2 amorphous silicon flat panel x-ray detector for radiographic imaging applications. Med Phys. (2000) vol.27, p.1324-1331.","DOI":"10.1118\/1.599010"},{"key":"8","doi-asserted-by":"crossref","first-page":"683","DOI":"10.1148\/radiology.218.3.r01fe45683","volume":"218","author":"CE Jr. FLOYD","year":"2001","unstructured":"8) FLOYD CE Jr. Imaging characteristics of an amorphous silicon flat-panel detector for digital chest radiography. Radiology. (2001) vol.218, p.683-688.","journal-title":"Radiology","ISSN":"https:\/\/id.crossref.org\/issn\/0033-8419","issn-type":"print"},{"key":"9","doi-asserted-by":"crossref","unstructured":"9) GINGOLD EL. Development of a novel high-resolution direct conversion x-ray detector. Proc. SPIE. (2000) vol.3977, p.185-193.","DOI":"10.1117\/12.384492"},{"key":"10","doi-asserted-by":"crossref","unstructured":"10) SAMEI E. A method for measuring the presampled MTF of digital radiographic systems using an edge test device. Med Phys. (1998) vol.25, p.102-113.","DOI":"10.1118\/1.598165"},{"key":"11","doi-asserted-by":"crossref","unstructured":"11) FLYNN MJ. Experimental comparison of noise and resolution for 2k and 4k storage phosphor radiography systems. Med Phys. (1999) vol.26, p.1612-1623.","DOI":"10.1118\/1.598656"},{"key":"12","doi-asserted-by":"crossref","unstructured":"12) FUJITA H. Basic imaging properties of a computed radiographic system with photostimulable phosphors. Med Phys. (1989) vol.16, p.52-59.","DOI":"10.1118\/1.596402"},{"key":"13","unstructured":"13) International Commission on Radiation Units and Measurements . Medical Imaging-The Assessment of Image Quality. ICRU Report. International Commission on Radiation Units and Measurements. (1996)"},{"key":"14","doi-asserted-by":"publisher","unstructured":"14) LAUNDERS JH. A comprehensive physical image quality evaluation of a selenium based digital X-ray imaging system for thorax radiography. Med. Phys.. (1998) vol.25, p.986-997. doi:10.1118\/1.598276","DOI":"10.1118\/1.598276"}],"container-title":["Japanese Journal of Radiological Technology"],"original-title":["Experimental Comparison of Flat-panel Detector Performance for Direct and Indirect Systems"],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/jjrt\/61\/12\/61_KJ00004022980\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,9,30]],"date-time":"2019-09-30T08:10:15Z","timestamp":1569831015000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/jjrt\/61\/12\/61_KJ00004022980\/_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2005]]},"references-count":14,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2005]]}},"URL":"https:\/\/doi.org\/10.6009\/jjrt.kj00004022980","relation":{},"ISSN":["0369-4305","1881-4883"],"issn-type":[{"value":"0369-4305","type":"print"},{"value":"1881-4883","type":"electronic"}],"subject":[],"published":{"date-parts":[[2005]]}}}