{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,30]],"date-time":"2026-07-30T09:23:50Z","timestamp":1785403430750,"version":"3.56.0"},"reference-count":37,"publisher":"Charter Services New York d\/b\/a Journal of Orthopaedic Experience and Innovation","issue":"1","license":[{"start":{"date-parts":[[2025,6,18]],"date-time":"2025-06-18T00:00:00Z","timestamp":1750204800000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"abstract":"<jats:sec id=\"background\">\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Tensioning and relaxation of grafts in tendon and ligament reconstruction surgeries significantly influence operation success, yet there are no clinically available technologies that can effectively measure both graft tension intra-operatively and during post-surgical recovery and rehabilitation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"objective\">\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>To address the lack of an effective technology to measure graft tension intra-operatively and post-operatively, an implantable sensor was developed to provide real-time suture loading biofeedback both during reconstruction for surgeons and during rehabilitation exercises for physical therapists.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"methods\">\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>This paper introduces a passively powered wireless sensor designed to monitor tension of tendon and ligament sutures fixed in orthopedic reconstruction surgeries. The inductive-capacitive-resistive (LCR) based sensor was designed to be used along with commercially available suture buttons to monitor loading in reconstructed tendons and ligaments.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"results\">\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Sensor loading experiments demonstrated a detection range from 5 N to 180 N with high repeatability (1.8 % change in sensitivity over 10,000 cycles). Additionally, the effects of depth, alignment, and orientation on signal transmission between the implantable sensor and an external detection device were characterized. Finally, the sensor was deployed in an anterior cruciate ligament reconstructed cadaver knee and used to detect graft loading during various knee joint movements.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"conclusion\">\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>This study established the design and basic functionality of a suture button accessory loading sensor to potentially assist orthopedic surgeons with surgical technique and help physical therapists with optimizing rehabilitation protocols for enhanced recovery in an effort to reduce failure rates.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.60118\/001c.128534","type":"journal-article","created":{"date-parts":[[2025,6,18]],"date-time":"2025-06-18T07:16:51Z","timestamp":1750231011000},"source":"Crossref","is-referenced-by-count":0,"title":["Wireless Suture Button Accessory Sensor for Intra- and Post-Operative Monitoring of Suture Loading in Soft Tissue Reconstruction"],"prefix":"10.60118","volume":"6","author":[{"given":"Salil S","family":"Karipott","sequence":"first","affiliation":[{"name":"Penderia Technologies Inc."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kaylee","family":"Meyers","sequence":"additional","affiliation":[{"id":[{"id":"https:\/\/ror.org\/0293rh119","id-type":"ROR","asserted-by":"publisher"}],"name":"University of Oregon","department":["Bioengineering, Knight Campus for Scientific Impact"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stephen","family":"Laffoon","sequence":"additional","affiliation":[{"name":"Penderia Technologies Inc."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"McGeehan","sequence":"additional","affiliation":[{"id":[{"id":"https:\/\/ror.org\/0293rh119","id-type":"ROR","asserted-by":"publisher"}],"name":"University of Oregon","department":["Bioengineering, Knight Campus for Scientific Impact"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Samuel","family":"Adams","sequence":"additional","affiliation":[{"id":[{"id":"https:\/\/ror.org\/03njmea73","id-type":"ROR","asserted-by":"publisher"}],"name":"Duke Medical Center"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jonathan","family":"Riboh","sequence":"additional","affiliation":[{"id":[{"id":"https:\/\/ror.org\/03446fm19","id-type":"ROR","asserted-by":"publisher"}],"name":"OrthoCarolina","department":["Sports Medicine Center"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nicholas","family":"Strasser","sequence":"additional","affiliation":[{"id":[{"id":"https:\/\/ror.org\/02vm5rt34","id-type":"ROR","asserted-by":"publisher"}],"name":"Vanderbilt University","department":["Department of Orthopedic Surgery"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ken","family":"Gall","sequence":"additional","affiliation":[{"id":[{"id":"https:\/\/ror.org\/00py81415","id-type":"ROR","asserted-by":"publisher"}],"name":"Duke University","department":["Department of Mechanical Engineering and Materials Science"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert","family":"Guldberg","sequence":"additional","affiliation":[{"id":[{"id":"https:\/\/ror.org\/0293rh119","id-type":"ROR","asserted-by":"publisher"}],"name":"University of Oregon","department":["Bioengineering, Knight Campus for Scientific Impact"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Keat Ghee","family":"Ong","sequence":"additional","affiliation":[{"id":[{"id":"https:\/\/ror.org\/0293rh119","id-type":"ROR","asserted-by":"publisher"}],"name":"University of Oregon","department":["Bioengineering, Knight Campus for Accelerating Scientific Impact"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"39661","published-online":{"date-parts":[[2025,6,18]]},"reference":[{"issue":"6","key":"ref1","doi-asserted-by":"publisher","first-page":"1160","DOI":"10.1002\/jor.23541","article-title":"Effects of ACL graft placement on in vivo knee function and cartilage thickness distributions","volume":"35","author":"L. E. DeFrate","year":"2017","journal-title":"J Orthop Res"},{"issue":"3","key":"ref2","doi-asserted-by":"publisher","first-page":"2325967120906522","DOI":"10.1177\/2325967120906522","article-title":"Does Early Functional Mobilization Affect Long-Term Outcomes After an Achilles Tendon Rupture? A Randomized Clinical Trial","volume":"8","author":"S. Aufwerber","year":"2020","journal-title":"Orthop J Sports Med"},{"issue":"4","key":"ref3","doi-asserted-by":"publisher","first-page":"737","DOI":"10.26603\/ijspt20180737","article-title":"Rehabilitation Following Isolated Posterior Cruciate Ligament Reconstruction: A Literature Review of Published Protocols","volume":"13","author":"M. Senese","year":"2018","journal-title":"Int J Sports Phys Ther"},{"issue":"1","key":"ref4","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1016\/j.berh.2019.01.018","article-title":"Evidence-based recommendations for the management of anterior cruciate ligament (ACL) rupture","volume":"33","author":"S. R. Filbay","year":"2019","journal-title":"Best Pract Res Clin Rheumatol"},{"issue":"7","key":"ref5","doi-asserted-by":"publisher","first-page":"1043","DOI":"10.1007\/s40279-019-01102-z","article-title":"Optimising the Late-Stage Rehabilitation and Return-to-Sport Training and Testing Process After ACL Reconstruction","volume":"49","author":"M. Buckthorpe","year":"2019","journal-title":"Sports Med"},{"issue":"4","key":"ref6","doi-asserted-by":"publisher","first-page":"697","DOI":"10.1016\/S0030-5898(02)00014-7","article-title":"Tensioning of the anterior cruciate ligament graft","volume":"33","author":"F. T. Heis","year":"2002","journal-title":"Orthop Clin North Am"},{"key":"ref7","doi-asserted-by":"publisher","first-page":"4657824","DOI":"10.1155\/2018\/4657824","article-title":"A Review on Biomechanics of Anterior Cruciate Ligament and Materials for Reconstruction","volume":"2018","author":"M. Marieswaran","year":"2018","journal-title":"Appl Bionics Biomech"},{"key":"ref8","doi-asserted-by":"publisher","first-page":"797389","DOI":"10.3389\/fbioe.2021.797389","article-title":"The Femoral Tunnel Drilling Angle at 45\u00b0 Coronal and 45\u00b0 Sagittal Provided the Lowest Peak Stress and Strain on the Bone Tunnels and Anterior Cruciate Ligament Graft","volume":"9","author":"R. Cheng","year":"2021","journal-title":"Front Bioeng Biotechnol"},{"issue":"3","key":"ref9","doi-asserted-by":"publisher","first-page":"208","DOI":"10.2519\/jospt.2012.3768","article-title":"Anterior cruciate ligament strain and tensile forces for weight-bearing and non-weight-bearing exercises: a guide to exercise selection","volume":"42","author":"R. F. Escamilla","year":"2012","journal-title":"J Orthop Sports Phys Ther"},{"key":"ref10","doi-asserted-by":"publisher","first-page":"6","DOI":"10.21037\/aoj-20-31","article-title":"Optimizing outcomes of anterior cruciate ligament (ACL) reconstruction in female athletes: from graft choice to return to sport criteria","volume":"2020","author":"E. G. Matzkin","journal-title":"Annals of Joint"},{"issue":"7","key":"ref11","doi-asserted-by":"publisher","first-page":"332","DOI":"10.1302\/2058-5241.2.160075","article-title":"Tendon injuries: Basic science and new repair proposals","volume":"2","author":"F. Wu","year":"2017","journal-title":"EFORT Open Rev"},{"issue":"2","key":"ref12","doi-asserted-by":"publisher","first-page":"1173","DOI":"10.1109\/JSEN.2021.3131299","article-title":"A Wireless, Battery-Free Embedded Sensor for Monitoring Tension on a Suture Anchor","volume":"22","author":"S. S. Karipott","year":"2022","journal-title":"IEEE Sensors J"},{"issue":"19","key":"ref13","doi-asserted-by":"publisher","first-page":"18384","DOI":"10.1109\/JSEN.2022.3200634","article-title":"Pledget Sensor to Monitor Loading in Tendon and Ligament Sutures During Postoperative Physical Therapy","volume":"22","author":"K. M. Meyers","year":"2022","journal-title":"IEEE Sensors J"},{"issue":"9","key":"ref14","doi-asserted-by":"publisher","first-page":"2524","DOI":"10.3390\/jcm11092524","article-title":"A 10-Year Follow-Up of Ankle Syndesmotic Injuries: Prospective Comparison of Knotless Suture-Button Fixation and Syndesmotic Screw Fixation","volume":"11","author":"J. N. Altmeppen","year":"2022","journal-title":"J Clin Med"},{"issue":"1-2","key":"ref15","doi-asserted-by":"publisher","first-page":"e249","DOI":"10.1093\/milmed\/usy142","article-title":"Current Practices in Anterior Cruciate Ligament Reconstruction in the U.S. Military: A Survey of the Society of Military Orthopaedic Surgeons","volume":"184","author":"J. Synovec","year":"2019","journal-title":"Mil Med"},{"issue":"3","key":"ref16","doi-asserted-by":"publisher","first-page":"384","DOI":"10.1016\/j.jor.2017.06.007","article-title":"Low incidence of failure after proximal biceps tenodesis with unicortical suture button","volume":"14","author":"J. B. Cook","year":"2017","journal-title":"J Orthop"},{"issue":"9","key":"ref17","doi-asserted-by":"publisher","first-page":"1074","DOI":"10.1016\/j.arthro.2008.02.014","article-title":"A novel transosseous button technique for rotator cuff repair","volume":"24","author":"M. P. Fox","year":"2008","journal-title":"Arthroscopy"},{"issue":"11","key":"ref18","doi-asserted-by":"publisher","first-page":"2638","DOI":"10.1177\/0363546520943633","article-title":"An Arthroscopic \"Inlay\" Bristow Procedure With Suture Button Fixation for the Treatment of Recurrent Anterior Glenohumeral Instability: 3-Year Follow-up","volume":"48","author":"Z. Shao","year":"2020","journal-title":"Am J Sports Med"},{"issue":"4","key":"ref19","doi-asserted-by":"publisher","first-page":"1023","DOI":"10.1177\/0363546519858745","article-title":"Suture Button Versus Hook Plate for Acute Unstable Acromioclavicular Joint Dislocation: A Meta-analysis","volume":"48","author":"C. Wang","year":"2020","journal-title":"Am J Sports Med"},{"issue":"6","key":"ref20","doi-asserted-by":"publisher","first-page":"e1595","DOI":"10.1016\/j.eats.2021.02.029","article-title":"Arthroscopic Suture-to-Loop Fixation of Posterior Cruciate Ligament Tibial Avulsion Fracture","volume":"10","author":"J. Tang","year":"2021","journal-title":"Arthrosc Tech"},{"issue":"2","key":"ref21","doi-asserted-by":"publisher","first-page":"61","DOI":"10.14517\/aosm20007","article-title":"Arthroscopic modular suspensory fixation of posterior cruciate ligament tibial avulsion fracture: a novel technique","volume":"8","author":"J. L. Z. Jie","year":"2021","journal-title":"Arthroscopy and Orthopedic Sports Medicine"},{"issue":"3","key":"ref22","doi-asserted-by":"publisher","first-page":"203","DOI":"10.1002\/bdrc.21041","article-title":"Tendon and ligament regeneration and repair: clinical relevance and developmental paradigm","volume":"99","author":"G. Yang","year":"2013","journal-title":"Birth Defects Res C Embryo Today"},{"issue":"10","key":"ref23","doi-asserted-by":"publisher","first-page":"2437","DOI":"10.1177\/0363546515596409","article-title":"Continuous Loop Double Endobutton Reconstruction for Acromioclavicular Joint Dislocation","volume":"43","author":"S. Struhl","year":"2015","journal-title":"Am J Sports Med"},{"issue":"3","key":"ref24","first-page":"1265","article-title":"An Embedded Wireless Temperature Sensor for Orthopedic Implants","volume":"18","author":"S. S. Karipott","year":"2018","journal-title":"IEEE Sensors J"},{"issue":"1","key":"ref25","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1007\/s11751-007-0016-6","article-title":"Biomechanics of the anterior cruciate ligament and implications for surgical reconstruction","volume":"2","author":"J. Dargel","year":"2007","journal-title":"Strategies Trauma Limb Reconstr"},{"issue":"1","key":"ref26","doi-asserted-by":"publisher","first-page":"66","DOI":"10.1177\/1941738108326980","article-title":"The function of the human anterior cruciate ligament and analysis of single- and double-bundle graft reconstructions","volume":"1","author":"F. R. Noyes","year":"2009","journal-title":"Sports Health"},{"key":"ref27","doi-asserted-by":"publisher","first-page":"209","DOI":"10.3390\/signals1020012","article-title":"Wireless Power Transfer Approaches for Medical Implants: A Review","volume":"1","author":"M. Haerinia","year":"2020","journal-title":"Signals"},{"key":"ref28","doi-asserted-by":"publisher","first-page":"1753944719826826","DOI":"10.1177\/1753944719826826","article-title":"An update on the CardioMEMS pulmonary artery pressure sensor","volume":"13","author":"P. Ayyadurai","year":"2019","journal-title":"Ther Adv Cardiovasc Dis"},{"issue":"4","key":"ref29","doi-asserted-by":"publisher","first-page":"255","DOI":"10.1080\/17434440.2018.1454310","article-title":"Clinical potential of implantable wireless sensors for orthopedic treatments","volume":"15","author":"S. S. Karipott","year":"2018","journal-title":"Expert Rev Med Devices"},{"key":"ref30","doi-asserted-by":"publisher","first-page":"109828","DOI":"10.1016\/j.jbiomech.2020.109828","article-title":"Lower limb biomechanics before and after anterior cruciate ligament reconstruction: A systematic review","volume":"106","author":"J. M. Moore","year":"2020","journal-title":"J Biomech"},{"issue":"10","key":"ref31","doi-asserted-by":"publisher","first-page":"1389","DOI":"10.1016\/j.arthro.2011.06.013","article-title":"Comparisons of femoral tunnel position and length in anterior cruciate ligament reconstruction: modified transtibial versus anteromedial portal techniques","volume":"27","author":"C. B. Chang","year":"2011","journal-title":"Arthroscopy"},{"key":"ref32","doi-asserted-by":"publisher","first-page":"6779207","DOI":"10.1155\/2022\/6779207","article-title":"Comparison of Rapid Rehabilitation after Anterior Cruciate Ligament Reconstruction with Tensioning Technique and Traditional Rehabilitation","volume":"2022","author":"T. Jin","year":"2022","journal-title":"Dis Markers"},{"issue":"12","key":"ref33","doi-asserted-by":"publisher","first-page":"3690","DOI":"10.1007\/s00167-018-4951-1","article-title":"Device-assisted tensioning is associated with lower rates of graft failure when compared to manual tensioning in ACL reconstruction","volume":"26","author":"L. Morrison","year":"2018","journal-title":"Knee Surgery, Sports Traumatology, Arthroscopy"},{"issue":"10","key":"ref34","doi-asserted-by":"publisher","first-page":"633","DOI":"10.5435\/00124635-201210000-00003","article-title":"Graft tensioning during knee ligament reconstruction: principles and practice","volume":"20","author":"S. L. Sherman","year":"2012","journal-title":"J Am Acad Orthop Surg"},{"issue":"1","key":"ref35","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1186\/s43019-021-00089-0","article-title":"Tibial-graft fixation methods on anterior cruciate ligament reconstructions: a literature review","volume":"33","author":"V. L. Pereira","year":"2021","journal-title":"Knee Surg Relat Res"},{"issue":"14","key":"ref36","doi-asserted-by":"publisher","first-page":"4623","DOI":"10.3390\/jcm12144623","article-title":"Manual and Device-Assisted Hamstring Autograft Tensioning Yield Similar Outcomes following ACL Reconstruction","volume":"12","author":"A. Piskopakis","year":"2023","journal-title":"J Clin Med"},{"issue":"6","key":"ref37","doi-asserted-by":"publisher","first-page":"1467","DOI":"10.1007\/s11999-008-0238-z","article-title":"Reconstruction technique affects femoral tunnel placement in ACL reconstruction","volume":"466","author":"M. K. Kaseta","year":"2008","journal-title":"Clin Orthop Relat Res"}],"container-title":["Journal of Orthopaedic Experience &amp; Innovation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journaloei.scholasticahq.com\/article\/128534-wireless-suture-button-accessory-sensor-for-intra-and-post-operative-monitoring-of-suture-loading-in-soft-tissue-reconstruction","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,18]],"date-time":"2025-06-18T07:16:51Z","timestamp":1750231011000},"score":1,"resource":{"primary":{"URL":"https:\/\/journaloei.scholasticahq.com\/article\/128534-wireless-suture-button-accessory-sensor-for-intra-and-post-operative-monitoring-of-suture-loading-in-soft-tissue-reconstruction"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,6,18]]},"references-count":37,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.60118\/001c.128534","relation":{},"ISSN":["2691-6541"],"issn-type":[{"value":"2691-6541","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,6,18]]}}}