{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,15]],"date-time":"2026-06-15T12:53:46Z","timestamp":1781528026248,"version":"3.54.1"},"reference-count":34,"publisher":"Elsevier BV","issue":"2","license":[{"start":{"date-parts":[[2015,2,1]],"date-time":"2015-02-01T00:00:00Z","timestamp":1422748800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2015,2,1]],"date-time":"2015-02-01T00:00:00Z","timestamp":1422748800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2015,2,28]],"date-time":"2015-02-28T00:00:00Z","timestamp":1425081600000},"content-version":"vor","delay-in-days":27,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/3.0\/"}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Clinics"],"published-print":{"date-parts":[[2015,2]]},"DOI":"10.6061\/clinics\/2015(02)08","type":"journal-article","created":{"date-parts":[[2015,3,16]],"date-time":"2015-03-16T15:12:13Z","timestamp":1426518733000},"page":"114-119","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":45,"title":["Surgical treatment of the osteoporotic spine with bone cement-injectable cannulated pedicle screw fixation: technical description and preliminary application in 43 patients"],"prefix":"10.1016","volume":"70","author":[{"given":"Fei","family":"Dai","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yaoyao","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fei","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dong","family":"Sun","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fei","family":"Luo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zehua","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jianzhong","family":"Xu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"5","key":"10.6061\/clinics\/2015(02)08_bib1","first-page":"392","article-title":"Research progress in application of vertebral pedicle screw augmentation in treating osteoporotic spine","volume":"21","author":"Teng","year":"2005","journal-title":"Chin J Trauma"},{"issue":"21","key":"10.6061\/clinics\/2015(02)08_bib2","doi-asserted-by":"crossref","first-page":"2415","DOI":"10.1097\/00007632-199411000-00008","article-title":"Effects of bone mineral density on pedicle screw fixation","volume":"19","author":"Halvorson","year":"1994","journal-title":"Spine"},{"issue":"1","key":"10.6061\/clinics\/2015(02)08_bib3","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1016\/S0736-0266(02)00093-1","article-title":"MicroCT evaluation of normal and osteoarthritic bone structure in human knee specimens","volume":"21","author":"Patel","year":"2003","journal-title":"J Orthop Res"},{"issue":"1","key":"10.6061\/clinics\/2015(02)08_bib4","doi-asserted-by":"crossref","first-page":"64","DOI":"10.1097\/00024720-200202000-00012","article-title":"Biomechanical evaluation of a double-threaded pedicle screw in elderly vertebrae","volume":"15","author":"Mummaneni","year":"2002","journal-title":"J Spinal Disord Tech"},{"issue":"5","key":"10.6061\/clinics\/2015(02)08_bib5","doi-asserted-by":"crossref","first-page":"513","DOI":"10.1016\/j.spinee.2004.02.006","article-title":"Pedicle screw fixation strength: pullout versus insertional torque","volume":"4","author":"Inceoglu","year":"2004","journal-title":"Spine J"},{"issue":"3","key":"10.6061\/clinics\/2015(02)08_bib6","doi-asserted-by":"crossref","first-page":"230","DOI":"10.1097\/00002517-200006000-00006","article-title":"Biomechanical evaluation and preliminary clinical experience with an expansive pedicle screw design","volume":"13","author":"Cook","year":"2000","journal-title":"J Spinal Disord Tech"},{"issue":"6","key":"10.6061\/clinics\/2015(02)08_bib7","doi-asserted-by":"crossref","first-page":"408","DOI":"10.1016\/S1529-9430(01)00119-X","article-title":"Characteristics of pullout failure in conical and cylindrical pedicle screws after full insertion and back-out","volume":"1","author":"Abshire","year":"2001","journal-title":"Spine J"},{"issue":"12","key":"10.6061\/clinics\/2015(02)08_bib8","doi-asserted-by":"crossref","first-page":"1374","DOI":"10.1097\/00007632-199806150-00015","article-title":"Revision Pedicle Screws: Bigger, Longer Shims-What Is Best","volume":"23","author":"Polly","year":"1998","journal-title":"Spine"},{"issue":"6","key":"10.6061\/clinics\/2015(02)08_bib9","first-page":"493","article-title":"Fracture risk during pedicle screw insertion in osteoporotic spine","volume":"11","author":"Hirano","year":"1998","journal-title":"J Spinal Disord Tech"},{"issue":"11","key":"10.6061\/clinics\/2015(02)08_bib10","doi-asserted-by":"crossref","first-page":"2485","DOI":"10.2106\/JBJS.G.00499","article-title":"Effect of micrometer-scale roughness of the surface of Ti6Al4V pedicle screws in vitro and in vivo","volume":"90","author":"Schwartz","year":"2008","journal-title":"J Bone Joint Surg Am"},{"issue":"3","key":"10.6061\/clinics\/2015(02)08_bib11","first-page":"300","article-title":"Pedicle screw salvage: the effect of depth and diameter on pull-out strength: a biomechanical study","volume":"34","author":"Talu","year":"2004","journal-title":"Acta Orthop Traumatol Turc"},{"issue":"4","key":"10.6061\/clinics\/2015(02)08_bib12","doi-asserted-by":"crossref","first-page":"305","DOI":"10.3340\/jkns.2009.46.4.305","article-title":"Polymethylmethacrylate-augmented screw fixation for stabilization of the osteoporotic spine: a three-year follow-up of 37 patients","volume":"46","author":"Moon","year":"2009","journal-title":"J Korean Neurosurgical Soc"},{"key":"10.6061\/clinics\/2015(02)08_bib13","first-page":"507826","article-title":"Minimally invasive spinal arthrodesis in osteoporotic population using a cannulated and fenestrated augmented screw: technical description and clinical experience","volume":"2012","author":"Lubansu","year":"2012","journal-title":"Minim Invasive Surg"},{"issue":"4","key":"10.6061\/clinics\/2015(02)08_bib14","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1007\/s10195-011-0164-9","article-title":"Fenestrated pedicle screws for cement-augmented purchase in patients with bone softening: a review of 21 cases","volume":"12","author":"Amendola","year":"2011","journal-title":"J Orthop Traumatol"},{"issue":"3","key":"10.6061\/clinics\/2015(02)08_bib15","doi-asserted-by":"crossref","first-page":"408","DOI":"10.1007\/s00586-011-1907-2","article-title":"Instrumented lumbar arthrodesis in elderly patients: prospective study using cannulated cemented pedicle screw instrumentation","volume":"20","author":"Pi\u00f1era","year":"2011","journal-title":"Eur Spine J"},{"key":"10.6061\/clinics\/2015(02)08_bib16","first-page":"33","article-title":"Transpedicular screw fixation in the thoracic and lumbar spine with a novel cannulated polyaxial screw system","volume":"1","author":"Weise","year":"2008","journal-title":"Med Devices (Auckl)"},{"issue":"11","key":"10.6061\/clinics\/2015(02)08_bib17","doi-asserted-by":"crossref","first-page":"1462","DOI":"10.1007\/s00586-008-0769-8","article-title":"Assessment of different screw augmentation techniques and screw designs in osteoporotic spines","volume":"17","author":"Becker","year":"2008","journal-title":"Eur Spine J"},{"issue":"8","key":"10.6061\/clinics\/2015(02)08_bib18","doi-asserted-by":"crossref","first-page":"1137","DOI":"10.1002\/jbmr.5650090802","article-title":"The diagnosis of osteoporosis","volume":"9","author":"Kanis","year":"1994","journal-title":"J Bone Miner Res"},{"issue":"18","key":"10.6061\/clinics\/2015(02)08_bib19","doi-asserted-by":"crossref","first-page":"1926","DOI":"10.1097\/00007632-199909150-00011","article-title":"Evaluation of pedicle screw position in thoracic and lumbar spine fixation using plain radiographs and computed tomography: a prospective study of 35 patients","volume":"24","author":"Sapkas","year":"1999","journal-title":"Spine"},{"issue":"4","key":"10.6061\/clinics\/2015(02)08_bib20","doi-asserted-by":"crossref","first-page":"E11","DOI":"10.3171\/foc.2001.10.4.12","article-title":"Surgical Interbody Research Group\u2013radiographic assessment of interbody fusion devices: fusion criteria for anterior lumbar interbody surgery","volume":"10","author":"Burkus","year":"2001","journal-title":"Neurosurg Focus"},{"issue":"11","key":"10.6061\/clinics\/2015(02)08_bib21","doi-asserted-by":"crossref","first-page":"1519","DOI":"10.2106\/00004623-199911000-00003","article-title":"Complications Associated with Pedicle Screws\u2217","volume":"81","author":"Lonstein","year":"1999","journal-title":"J Bone Joint Surg Am"},{"key":"10.6061\/clinics\/2015(02)08_bib22","doi-asserted-by":"crossref","first-page":"278","DOI":"10.1097\/00003086-199311000-00045","article-title":"Effect of screw diameter, insertion technique, and bone cement augmentation of pedicular screw fixation strength","volume":"296","author":"WITTENBERG","year":"1993","journal-title":"Clin Orthop Relat Res"},{"issue":"3","key":"10.6061\/clinics\/2015(02)08_bib23","doi-asserted-by":"crossref","first-page":"350","DOI":"10.1097\/00007632-199402000-00017","article-title":"Repair of failed transpedicle screw fixation: a biomechanical study comparing polymethylmethacrylate, milled bone, and matchstick bone reconstruction","volume":"19","author":"Pfeifer","year":"1994","journal-title":"Spine"},{"issue":"1","key":"10.6061\/clinics\/2015(02)08_bib24","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1302\/0301-620X.76B1.8300663","article-title":"Neurological deterioration after cement injection into a vertebral body","volume":"76","author":"Wilkes","year":"1994","journal-title":"J Bone Joint Surg Br"},{"issue":"1","key":"10.6061\/clinics\/2015(02)08_bib25","first-page":"45","article-title":"Percutaneous vertebral surgery","volume":"24","author":"Chiras","year":"1997","journal-title":"Technics and indications. J Neuroradiol"},{"issue":"19","key":"10.6061\/clinics\/2015(02)08_bib26","doi-asserted-by":"crossref","first-page":"E416","DOI":"10.1097\/00007632-200210010-00021","article-title":"Pulmonary embolism of polymethylmethacrylate after percutaneous vertebroplasty: a report of three cases","volume":"27","author":"Jang","year":"2002","journal-title":"Spine (Phila Pa 1976)"},{"issue":"19","key":"10.6061\/clinics\/2015(02)08_bib27","doi-asserted-by":"crossref","first-page":"E419","DOI":"10.1097\/00007632-200210010-00022","article-title":"Paraplegia as a complication of percutaneous vertebroplasty with polymethylmethacrylate: a case report","volume":"27","author":"Lee","year":"2002","journal-title":"Spine (Phila Pa 1976)"},{"issue":"3","key":"10.6061\/clinics\/2015(02)08_bib28","doi-asserted-by":"crossref","first-page":"902","DOI":"10.1148\/radiol.2283030235","article-title":"Cardiovascular Collapse and Death during Vertebroplasty [letter]","volume":"228","author":"Childers","year":"2003","journal-title":"Radiology"},{"issue":"3","key":"10.6061\/clinics\/2015(02)08_bib29","doi-asserted-by":"crossref","first-page":"531","DOI":"10.1227\/01.NEU.0000290899.15567.68","article-title":"Segmental polymethylmethacrylate-augmented pedicle screw fixation in patients with bone softening caused by osteoporosis and metastatic tumor involvement: a clinical evaluation","volume":"61","author":"Frankel","year":"2007","journal-title":"Neurosurgery"},{"issue":"3","key":"10.6061\/clinics\/2015(02)08_bib30","doi-asserted-by":"crossref","first-page":"366","DOI":"10.3171\/SPI-07\/09\/366","article-title":"Increasing pedicle screw anchoring in the osteoporotic spine by cement injection through the implant","volume":"7","author":"Fransen","year":"2007","journal-title":"J Neurosurg Spine"},{"issue":"8","key":"10.6061\/clinics\/2015(02)08_bib31","doi-asserted-by":"crossref","first-page":"613","DOI":"10.1016\/j.clinbiomech.2009.05.002","article-title":"Pullout strength for cannulated pedicle screws with bone cement augmentation in severely osteoporotic bone: influences of radial hole and pilot hole tapping","volume":"24","author":"Chen","year":"2009","journal-title":"Clin Biomech (Bristol, Avon)"},{"issue":"15","key":"10.6061\/clinics\/2015(02)08_bib32","doi-asserted-by":"crossref","first-page":"2231","DOI":"10.1097\/00007632-199311000-00015","article-title":"Complications Associated with the Technique of Pedicle Screw Fixation A Selected Survey of ABS Members","volume":"18","author":"Esses","year":"1993","journal-title":"Spine"},{"issue":"7","key":"10.6061\/clinics\/2015(02)08_bib33","doi-asserted-by":"crossref","first-page":"e15","DOI":"10.1016\/j.spinee.2011.06.002","article-title":"Stem fracture after total facet replacement in the lumbar spine: a report of two cases and review of the literature","volume":"11","author":"Palmer","year":"2011","journal-title":"Spine J"},{"issue":"1","key":"10.6061\/clinics\/2015(02)08_bib34","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1097\/01.bsd.0000211243.44706.2b","article-title":"PLIF with a titanium cage and excised facet joint bone for degenerative spondylolisthesis&mdash;in augmentation with a pedicle screw","volume":"20","author":"Okuyama","year":"2007","journal-title":"J Spinal Disord Tech"}],"container-title":["Clinics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1807593222008043?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1807593222008043?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/clinics.org.br\/uploads\/artigos\/cln-70-02\/cln-70-02-114.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,29]],"date-time":"2025-10-29T06:52:27Z","timestamp":1761720747000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1807593222008043"},"secondary":[{"URL":"http:\/\/www.scielo.br\/scielo.php?script=sci_abstract&pid=S1807-59322015000200114&lng=en&nrm=iso","label":"SCIELO"},{"URL":"http:\/\/www.ncbi.nlm.nih.gov\/pmc\/articles\/PMC4351308\/?report=classic","label":"PMC"}]},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,2]]},"references-count":34,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2015,2]]}},"alternative-id":["S1807593222008043"],"URL":"https:\/\/doi.org\/10.6061\/clinics\/2015(02)08","relation":{},"ISSN":["1807-5932"],"issn-type":[{"value":"1807-5932","type":"print"}],"subject":[],"published":{"date-parts":[[2015,2]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Surgical treatment of the osteoporotic spine with bone cement-injectable cannulated pedicle screw fixation: technical description and preliminary application in 43 patients","name":"articletitle","label":"Article Title"},{"value":"Clinics","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.6061\/clinics\/2015(02)08","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2015 CLINICS. Published by Elsevier Spain","name":"copyright","label":"Copyright"}]}}