{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,8,2]],"date-time":"2025-08-02T18:56:06Z","timestamp":1754160966482,"version":"3.41.2"},"reference-count":24,"publisher":"Danish Medical Association","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Ugeskr L\u00e6ger"],"abstract":"<jats:p>This review examines whether MRI can reliably replace wrist arthroscopy in diagnosing TFCC injuries of the ulnar wrist, based on 18 articles selected through PubMed, Embase, and Cochrane Library. MRI shows improvement in diagnosing TFCC injuries, and the predictive values of MRI get significantly better by using tools like post-processing techniques, contrast, and pathological markers. However, MRI is unreliable as an independent diagnostic tool for TFCC lesions that need surgical treatment. More well-designed studies are required to determine this diagnostic modality\u2019s clinical relevance.<\/jats:p>","DOI":"10.61409\/v05240362","type":"journal-article","created":{"date-parts":[[2025,2,4]],"date-time":"2025-02-04T05:17:19Z","timestamp":1738646239000},"page":"1-9","source":"Crossref","is-referenced-by-count":0,"title":["The MR scan of triangular fibrocartilaginous complex injuries"],"prefix":"10.61409","author":[{"given":"Ditte Nortov","family":"Schreiner","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiong","family":"Xie","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Robert","family":"Gvozdenovic","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"40208","published-online":{"date-parts":[[2025,1,27]]},"reference":[{"doi-asserted-by":"publisher","unstructured":"Palmer AK. Triangular fibrocartilage complex lesions: a classification. J Hand Surg Am. 1989;14(4):594-606. https:\/\/doi.org\/10.1016\/0363-5023(89)90174-3","key":"ref0","DOI":"10.1016\/0363-5023(89)90174-3"},{"doi-asserted-by":"publisher","unstructured":"Luetkens KS, Laas SF, Hassler S et al. Contrast-enhanced MRI of the wrist: Intravenous application of gadolinium improves diagnosis in ulnar-sided injuries of the TFCC. Eur J Radiol. 2021;143:109901. https:\/\/doi.org\/10.1016\/j.ejrad.2021.109901","key":"ref1","DOI":"10.1016\/j.ejrad.2021.109901"},{"doi-asserted-by":"publisher","unstructured":"Spies CK, Unglaub F, Bruckner T et al. Diagnostic accuracy of wrist MRI in comparison to wrist arthroscopy regarding TFCC lesions in clinical practice. Arch Orthop Trauma Surg. 2022;142(5):879-85. https:\/\/doi.org\/10.1007\/s00402-021-04329-6","key":"ref2","DOI":"10.1007\/s00402-021-04329-6"},{"doi-asserted-by":"publisher","unstructured":"Morley J, Bidwell J, Bransby-Zachary M. A comparison of the findings of wrist arthroscopy and magnetic resonance imaging in the investigation of wrist pain. J Hand Surg. 2001;26(6):544-6. https:\/\/doi.org\/10.1054\/jhsb.2001.0645","key":"ref3","DOI":"10.1054\/jhsb.2001.0645"},{"doi-asserted-by":"publisher","unstructured":"Blazar PE, Chan PS, Kneeland JB et al. The effect of observer experience on magnetic resonance imaging interpretation and localization of triangular fibrocartilage complex lesions. J Hand Surg Am. 2001;26(4):742-8. https:\/\/doi.org\/10.1053\/jhsu.2001.24966","key":"ref4","DOI":"10.1053\/jhsu.2001.24966"},{"doi-asserted-by":"publisher","unstructured":"Damkj\u00e6r MW, Hess S, Gerke O et al. Kritisk l\u00e6sning af artikler om diagnostiske studier. Ugeskr L\u00e6ger. 2024;186:V06230404. https:\/\/doi.org\/10.61409\/V06230404","key":"ref5","DOI":"10.61409\/V06230404"},{"doi-asserted-by":"publisher","unstructured":"Cohen JF, Korevaar DA, Altman DG et al. STARD 2015 guidelines for reporting diagnostic accuracy studies: explanation and elaboration. BMJ Open. 2016;6(11):e012799. https:\/\/doi.org\/10.1136\/bmjopen-2016-012799","key":"ref6","DOI":"10.1136\/bmjopen-2016-012799"},{"doi-asserted-by":"publisher","unstructured":"Boer BC, Vestering M, van Raak SM et al. MR arthrography is slightly more accurate than conventional MRI in detecting TFCC lesions of the wrist. Eur J Orthop Surg Traumatol. 2018;28(8):1549-1553. https:\/\/doi.org\/10.1007\/s00590-018-2215-x","key":"ref7","DOI":"10.1007\/s00590-018-2215-x"},{"doi-asserted-by":"publisher","unstructured":"Lee YH, Choi YR, Kim S et al. Intrinsic ligament and triangular fibrocartilage complex (TFCC) tears of the wrist: comparison of isovolumetric 3D-THRIVE sequence MR arthrography and conventional MR image at 3 T. Magn Reson Imaging. 2013;31(2):221-6. https:\/\/doi.org\/10.1016\/j.mri.2012.06.024","key":"ref8","DOI":"10.1016\/j.mri.2012.06.024"},{"doi-asserted-by":"publisher","unstructured":"Haims AH, Schweitzer ME, Morrison WB et al. Limitations of MR imaging in the diagnosis of peripheral tears of the triangular fibrocartilage of the wrist. AJR Am J Roentgenol. 2002;178(2):419-22. https:\/\/doi.org\/10.2214\/ajr.178.2.1780419","key":"ref9","DOI":"10.2214\/ajr.178.2.1780419"},{"doi-asserted-by":"publisher","unstructured":"Nevalainen MT, Zoga AC, Rivlin M et al. Extensor carpi ulnaris tendon pathology and ulnar styloid bone marrow edema as diagnostic markers of peripheral triangular fibrocartilage complex tears on wrist MRI: a case-control study. Eur Radiol. 2023;33(5):3172-3177. https:\/\/doi.org\/10.1007\/s00330-023-09446-x","key":"ref10","DOI":"10.1007\/s00330-023-09446-x"},{"doi-asserted-by":"publisher","unstructured":"Eladawi S, Balamoody S, Amerasekera S, Choudhary S. 3T MRI of wrist ligaments and TFCC using true plane oblique 3D T2 Dual Echo Steady State (DESS) - a study of diagnostic accuracy. Br J Radiol. 2022;95(1129):20210019. https:\/\/doi.org\/10.1259\/bjr.20210019","key":"ref11","DOI":"10.1259\/bjr.20210019"},{"doi-asserted-by":"publisher","unstructured":"Magee T. Comparison of 3-T MRI and arthroscopy of intrinsic wrist ligament and TFCC tears. AJR Am J Roentgenol. 2009;192(1):80-5. https:\/\/doi.org\/10.2214\/AJR.08.1089","key":"ref12","DOI":"10.2214\/AJR.08.1089"},{"doi-asserted-by":"publisher","unstructured":"Petsatodis E, Pilavaki M, Kalogera A et al. Comparison between conventional MRI and MR arthrography in the diagnosis of triangular fibrocartilage tears and correlation with arthroscopic findings. Injury. 2019;50(8):1464-1469. https:\/\/doi.org\/10.1016\/j.injury.2019.07.032","key":"ref13","DOI":"10.1016\/j.injury.2019.07.032"},{"unstructured":"Brennan CM, Yong LY, Foley J et al. The value of the distal radioulnar joint effusion in diagnosing triangular fibrocartilage complex tears on magnetic resonance imaging. Arch Bone Jt Surg. 2021;9(4):423-426. https:\/\/doi.org\/10.22038\/abjs.2020.48520.2464","key":"ref14"},{"doi-asserted-by":"publisher","unstructured":"De Santis S, Cozzolino R, Luchetti R, Cazzoletti L. Comparison between MRI and Arthroscopy of the Wrist for the Assessment of Posttraumatic Lesions of Intrinsic Ligaments and the Triangular Fibrocartilage Complex. J Wrist Surg. 2021;11(1):28-34. https:\/\/doi.org\/10.1055\/s-0041-1729757","key":"ref15","DOI":"10.1055\/s-0041-1729757"},{"doi-asserted-by":"publisher","unstructured":"Huflage H, Luetkens KS, Kunz AS et al. Improved diagnostic accuracy for ulnar-sided TFCC lesions with radial reformation of 3D sequences in wrist MR arthrography. Eur Radiol. 2021;31(12):9399-9407. https:\/\/doi.org\/10.1007\/s00330-021-08024-3","key":"ref16","DOI":"10.1007\/s00330-021-08024-3"},{"doi-asserted-by":"publisher","unstructured":"Santo S, Omokawa S, Iida A et al. Magnetic resonance imaging analysis of the extensor carpi ulnaris tendon and distal radioulnar joint in triangular fibrocartilage complex tears. J Orthop Sci. 2018;23(6):953-958. https:\/\/doi.org\/10.1016\/j.jos.2018.05.009","key":"ref17","DOI":"10.1016\/j.jos.2018.05.009"},{"doi-asserted-by":"publisher","unstructured":"Yan M, Wen S, Wang X. Quantitative analysis of triangular fibrocartilage complex injury by 3.0T MR 3D VIBE and T2 mapping techniques. Medicine (Baltimore). 2022;101(51):e31589. https:\/\/doi.org\/10.1097\/MD.0000000000031589","key":"ref18","DOI":"10.1097\/MD.0000000000031589"},{"doi-asserted-by":"publisher","unstructured":"Tanaka T, Yoshioka H, Ueno T et al. Comparison between high-resolution MRI with a microscopy coil and arthroscopy in triangular fibrocartilage complex injury. J Hand Surg Am. 2006;31(8):1308-14. https:\/\/doi.org\/10.1016\/j.jhsa.2006.05.001","key":"ref19","DOI":"10.1016\/j.jhsa.2006.05.001"},{"doi-asserted-by":"publisher","unstructured":"Iordache SD, Rowan R, Garvin GJ et al. Prevalence of triangular fibrocartilage complex abnormalities on MRI scans of asymptomatic wrists. J Hand Surg Am. 2012;37(1):98-103. https:\/\/doi.org\/10.1016\/j.jhsa.2011.10.006","key":"ref20","DOI":"10.1016\/j.jhsa.2011.10.006"},{"doi-asserted-by":"publisher","unstructured":"Park A, Lutsky K, Matzon J et al. An evaluation of the reliability of wrist arthroscopy in the assessment of tears of the triangular fibrocartilage complex. J Hand Surg Am. 2018;43(6):545-549. https:\/\/doi.org\/10.1016\/j.jhsa.2018.02.031","key":"ref21","DOI":"10.1016\/j.jhsa.2018.02.031"},{"doi-asserted-by":"publisher","unstructured":"Low S, Pillukat T, Prommersberger KJ, van Schoonhoven J. The effect of additional video documentation to photo documentation in wrist arthroscopies on intra- and interobserver reliability. Arch Orthop Trauma Surg. 2013;133(3):433-8. https:\/\/doi.org\/10.1007\/s00402-012-1670-9","key":"ref22","DOI":"10.1007\/s00402-012-1670-9"},{"doi-asserted-by":"publisher","unstructured":"L\u00f6w S, Erne H, Sch\u00fctz A et al. The required minimum length of video sequences for obtaining a reliable interobserver diagnosis in wrist arthroscopies. Arch Orthop Trauma Surg. 2015;135(12):1771-7. https:\/\/doi.org\/10.1007\/s00402-015-2339-y","key":"ref23","DOI":"10.1007\/s00402-015-2339-y"}],"container-title":["Ugeskrift for L\u00e6ger"],"original-title":[],"deposited":{"date-parts":[[2025,7,28]],"date-time":"2025-07-28T09:16:04Z","timestamp":1753694164000},"score":1,"resource":{"primary":{"URL":"https:\/\/ugeskriftet.dk\/videnskab\/V05240362"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,1,27]]},"references-count":24,"URL":"https:\/\/doi.org\/10.61409\/v05240362","relation":{},"ISSN":["0041-5782","1603-6824"],"issn-type":[{"type":"print","value":"0041-5782"},{"type":"electronic","value":"1603-6824"}],"subject":[],"published":{"date-parts":[[2025,1,27]]}}}