{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,6]],"date-time":"2026-05-06T11:37:51Z","timestamp":1778067471702,"version":"3.51.4"},"reference-count":0,"publisher":"Tunisian Society of Medical Sciences","issue":"9","license":[{"start":{"date-parts":[[2024,8,27]],"date-time":"2024-08-27T00:00:00Z","timestamp":1724716800000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Tunis Med"],"abstract":"<jats:p>Objectives\u00a0: To evaluate the agreement of\u00a0 cardiac index (CI) calculated by Ultrasonic sonic cardiac output monitor (USCOM) and\u00a0 transthoracic thoracic echocardiography (TTE) in order to know if we can recommend USCOM in our pediatric intensive care unit (PICU).\nDesign\u00a0: Prospective observational evaluative study carried out over a period of 3 months\nSetting: PICU at children's hospital in Tunis\nParticipants: All newborns without tracheostomy or a known congenital heart disease, admitted to the PICU during the study period were enrolled.\nInterventions: Paired and consecutive measurements of CI were obtained in all patients with both technologies. All measurements by TTE and USCOM were performed by two distinct operators. It is the average of three successive measures of the CI, in the same patient, with each technology, which was considered.\nAgreement of CI between the 2\u00a0 techniques was assessed by Bland-Altman analysis and percentage error.\nMeasurements and Main Results\u00a0: Forty-two infants \u00a0were analyzed with the mean (standard deviation) gestation 36 weeks ( 5 days), age 1 days (1.09) , and weight 2.9 kg (0.87). Respiratory\u00a0 failure was the main cause of admission 75%. At the time of the study, 33 (75.%) patients were ventilated artificially. Bias (mean difference) of the CI between the two methods was 1.2 l\/min\/m2 and precision (\u00b1 2 SD of differences) was 1.08 l\/min\/m2.\nThe MPE of CI measurement for USCOM vs TTE was 54.9%.\nConclusions : The USCOM showed a poor agreement to TTE measures of CI. The two methods cannot be considered interchangeable.<\/jats:p>","DOI":"10.62438\/tunismed.v102i9.5095","type":"journal-article","created":{"date-parts":[[2024,10,10]],"date-time":"2024-10-10T09:00:27Z","timestamp":1728550827000},"source":"Crossref","is-referenced-by-count":1,"title":["Agreement of cardiac index measurements between ultrasonic cardiac output monitor  and transthoracic echocardiography in neonates"],"prefix":"10.62438","volume":"102","author":[{"given":"Khaled","family":"Menif","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ahmed","family":"Ayari","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Assaad","family":"Louati","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shatila","family":"Ibn Haj Hassine","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Asma","family":"Bouziri","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Aida","family":"Borgi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"31112","published-online":{"date-parts":[[2024,8,27]]},"container-title":["La Tunisie M\u00e9dicale"],"original-title":[],"deposited":{"date-parts":[[2024,10,10]],"date-time":"2024-10-10T09:00:27Z","timestamp":1728550827000},"score":1,"resource":{"primary":{"URL":"https:\/\/latunisiemedicale.com\/index.php\/tunismed\/article\/view\/5095"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,8,27]]},"references-count":0,"journal-issue":{"issue":"9","published-online":{"date-parts":[[2024,8,27]]}},"URL":"https:\/\/doi.org\/10.62438\/tunismed.v102i9.5095","relation":{},"ISSN":["2724-7031","0041-4131"],"issn-type":[{"value":"2724-7031","type":"electronic"},{"value":"0041-4131","type":"print"}],"subject":[],"published":{"date-parts":[[2024,8,27]]}}}