{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,17]],"date-time":"2026-09-17T20:14:04Z","timestamp":1789676044127,"version":"4.0.1"},"reference-count":32,"publisher":"Molecular Vision","license":[{"start":{"date-parts":[[2026,5,12]],"date-time":"2026-05-12T00:00:00Z","timestamp":1778544000000},"content-version":"vor","delay-in-days":74,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,2,27]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To assess the diagnostic value of corneal epithelial thickness parameters measured by RTVue XR OCT in different stages of keratoconus.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>This is a cross-sectional study of 64 patients (64 eyes) with keratoconus who visited from January 2021 to December 2023. The control group randomly had 46 patients (46 eyes) with refractive errors. The RTVue XR OCT was used to measure the distribution and parameter indicators of corneal epithelial thickness in various regions of the normal corneal group. We measured parameters with statistically significant differences and calculated cutoff points, sensitivity, specificity, the area under the receiver operating characteristic curve, and the Youden index for the parameter indicators in the preclinical, mild, moderate, and severe keratoconus groups during the clinical period and in the normal control group.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>The normal corneal epithelial thickness was unevenly distributed in various regions within the range of 0 to 5 mm. The cornea was thinner above and below the nose, as well as thicker above and below the temporal area, and the central area of the cornea was the thinnest. The Min-Max parameter showed the highest diagnostic value for preclinical keratoconus. For mild, moderate, and severe keratoconus, parameters including superior-inferior (S-I), supranasal (SN)-infranasal (IT), Max, and standard deviation showed high diagnostic value. SN-IT and standard deviation demonstrated high specificity and sensitivity in distinguishing the clinical keratoconus groups from the normal control group.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Corneal epithelial thickness parameters are valuable for diagnosing various stages of keratoconus. The Min-Max parameter is particularly valuable for preclinical diagnosis, while SN-IT and standard deviation are highly valuable for diagnosing clinical stages.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.63500\/mv_v32_143","type":"journal-article","created":{"date-parts":[[2026,5,12]],"date-time":"2026-05-12T14:23:54Z","timestamp":1778595834000},"page":"143-153","source":"Crossref","is-referenced-by-count":0,"title":["The role of corneal epithelial thickness parameters with different degrees of keratoconus in the diagnosis of keratoconus"],"prefix":"10.63500","volume":"32","author":[{"given":"Tao","family":"Wang","sequence":"first","affiliation":[{"name":"Department of Ophthalmology, Shangqiu Optometric Eye Hospital, Shangqiu City, Henan Province, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qixin","family":"Cao","sequence":"additional","affiliation":[{"name":"Scientific Research and Education Department, Huzhou Traditional Chinese Medicine Hospital, Huzhou City, Zhejiang Province, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"52877","published-online":{"date-parts":[[2026,2,27]]},"reference":[{"key":"2026091715575419900_r1","article-title":"Advances in the diagnosis and treatment of keratoconus","volume":"13","author":"Atalay","year":"2021","journal-title":"Ther Adv Ophthalmol"},{"key":"2026091715575419900_r2","doi-asserted-by":"crossref","DOI":"10.1016\/j.clae.2021.101559","article-title":"Keratoconus: An updated review","volume":"45","author":"Santodomingo-Rubido","year":"2022","journal-title":"Cont Lens Anterior Eye"},{"key":"2026091715575419900_r3","doi-asserted-by":"crossref","first-page":"422","DOI":"10.1080\/08164622.2022.2048172","article-title":"Incidence of myopic shift and related factors in young Chinese adults","volume":"106","author":"Duan","year":"2023","journal-title":"Clin Exp Optom"},{"key":"2026091715575419900_r4","doi-asserted-by":"crossref","unstructured":"Tian\n              JX\n            \n          . A review of myopia treatment methods and their research progress. Highlights in Science, Engineering and Technology. 2022;7:27. doi: 10.54097\/hset.v6i.980.10.54097\/hset.v6i.980","DOI":"10.54097\/hset.v6i.980"},{"key":"2026091715575419900_r5","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1016\/j.oftal.2022.07.001","article-title":"Update on contraindications in laser corneal refractive surgery","volume":"98","author":"Ortega-Usobiaga","year":"2023","journal-title":"Arch Soc Esp Oftalmol (Engl Ed)"},{"key":"2026091715575419900_r6","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1055\/a-1920-6929","article-title":"Differential Diagnosis of Keratoconus Based on New Technologies","volume":"240","author":"Sideroudi","year":"2023","journal-title":"Klin Monbl Augenheilkd"},{"key":"2026091715575419900_r7","doi-asserted-by":"crossref","first-page":"3139","DOI":"10.1007\/s10792-023-02713-2","article-title":"Repeatability of corneal pachymetry and epithelial thickness measurements with spectral-domain optical coherence tomography (SD-OCT) and correlation to ocular surface parameters","volume":"43","author":"Chatzistergiou","year":"2023","journal-title":"Int Ophthalmol"},{"key":"2026091715575419900_r8","doi-asserted-by":"crossref","first-page":"275","DOI":"10.1016\/j.jcrs.2015.09.020","article-title":"Accuracy of machine learning classifiers using bilateral data from a Scheimpflug camera for identifying eyes with preclinical signs of keratoconus","volume":"42","author":"Kov\u00e1cs","year":"2016","journal-title":"J Cataract Refract Surg"},{"key":"2026091715575419900_r9","first-page":"891","article-title":"Chinese expert consensus on Keratoconus diagnosis and treatment (2019)","volume":"55","author":"Group of keratology, Society of Ophthalmology, Chinese Medical Association","year":"2019","journal-title":"Zhonghua Yan Ke Za Zhi"},{"key":"2026091715575419900_r10","first-page":"1640","article-title":"Histopathologic findings of keratoconus corneas underwent penetrating keratoplasty according to topographic measurements and keratoconus severity","volume":"10","author":"Naderan","year":"2017","journal-title":"Int J Ophthalmol"},{"key":"2026091715575419900_r11","article-title":"Real dynamic assessment of tear film optical quality for monitoring and early prevention of dry eye","volume":"99","author":"Wu","year":"2020","journal-title":"Medicine (Baltimore)"},{"key":"2026091715575419900_r12","article-title":"Comparison of corneal thickness measurements using ultrasound pachymetry, noncontact tonopachy, Pentacam HR, and Fourier-domain OCT","volume":"100","author":"Kim","year":"2021","journal-title":"Medicine (Baltimore)"},{"key":"2026091715575419900_r13","doi-asserted-by":"crossref","first-page":"269","DOI":"10.1016\/j.optom.2019.11.001","article-title":"A review of corneal imaging methods for the early diagnosis of pre-clinical Keratoconus","volume":"13","author":"Masiwa","year":"2020","journal-title":"J Optom"},{"key":"2026091715575419900_r14","doi-asserted-by":"crossref","first-page":"2403","DOI":"10.1016\/j.ophtha.2013.05.027","article-title":"Fourier-domain optical coherence tomography imaging in keratoconus: a corneal structural classification","volume":"120","author":"Sandali","year":"2013","journal-title":"Ophthalmology"},{"key":"2026091715575419900_r15","doi-asserted-by":"crossref","first-page":"2425","DOI":"10.1016\/j.ophtha.2012.06.023","article-title":"Corneal epithelial thickness mapping by Fourier-domain optical coherence tomography in normal and keratoconic eyes","volume":"119","author":"Li","year":"2012","journal-title":"Ophthalmology"},{"key":"2026091715575419900_r16","first-page":"1","article-title":"Keratoconus and subclinical keratoconus were screened by OCT corneal epithelial topography","volume-title":"Wenzhou Medical College","author":"Wang","year":"2016"},{"key":"2026091715575419900_r17","doi-asserted-by":"crossref","first-page":"792","DOI":"10.1016\/j.ophtha.2006.01.048","article-title":"Corneal pachymetry mapping with high-speed optical coherence tomography","volume":"113","author":"Li","year":"2006","journal-title":"Ophthalmology"},{"key":"2026091715575419900_r18","doi-asserted-by":"crossref","first-page":"360","DOI":"10.1097\/01.opx.0000221388.26031.23","article-title":"The repeatability of corneal and corneal epithelial thickness measurements using optical coherence tomography","volume":"83","author":"Sin","year":"2006","journal-title":"Optom Vis Sci"},{"key":"2026091715575419900_r19","first-page":"177","article-title":"Evaluation of repeatability and accuracy of RTVue Fourier optical coherence tomography in measuring corneal parameters","volume":"31","author":"Hua","year":"2013","journal-title":"Chinese Journal of Experimental Ophthalmology."},{"key":"2026091715575419900_r20","doi-asserted-by":"crossref","first-page":"1544","DOI":"10.1097\/ICO.0b013e3182a7f39d","article-title":"Repeatability of corneal epithelial thickness measurements using Fourier-domain optical coherence tomography in normal and post-LASIK eyes","volume":"32","author":"Ma","year":"2013","journal-title":"Cornea"},{"key":"2026091715575419900_r21","doi-asserted-by":"crossref","first-page":"959","DOI":"10.1007\/s10792-017-0543-1","article-title":"Repeatability and agreement of central corneal thickness measurement with non-contact methods: a comparative study","volume":"38","author":"Mansoori","year":"2018","journal-title":"Int Ophthalmol"},{"key":"2026091715575419900_r22","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1016\/j.sjopt.2017.04.003","article-title":"Intrasession repeatability of pachymetry measurements with RTVue XR 100 optical coherence tomography in normal cornea","volume":"31","author":"Mansoori","year":"2017","journal-title":"Saudi J Ophthalmol"},{"key":"2026091715575419900_r23","doi-asserted-by":"crossref","first-page":"555","DOI":"10.3928\/1081597X-20091105-02","article-title":"Epithelial thickness after hyperopic LASIK: three-dimensional display with Artemis very high-frequency digital ultrasound","volume":"26","author":"Reinstein","year":"2010","journal-title":"J Refract Surg"},{"key":"2026091715575419900_r24","first-page":"215","article-title":"Characteristic analysis of corneal epithelial thickness in patients with refractive errors","volume":"32","author":"Jiang","year":"2019","journal-title":"Journal of Shantou University School of Medicine."},{"key":"2026091715575419900_r25","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1159\/000500313","article-title":"Comparison of Corneal Epithelial and Stromal Thickness between Keratoconic and Normal Eyes in an Asian Population","volume":"62","author":"Wang","year":"2019","journal-title":"Ophthalmic Res"},{"key":"2026091715575419900_r26","doi-asserted-by":"crossref","first-page":"812","DOI":"10.1016\/j.jcrs.2014.06.043","article-title":"Corneal epithelial thickness mapping using Fourier-domain optical coherence tomography for detection of form fruste keratoconus","volume":"41","author":"Temstet","year":"2015","journal-title":"J Cataract Refract Surg"},{"key":"2026091715575419900_r27","doi-asserted-by":"crossref","DOI":"10.1155\/2016\/5697343","article-title":"Assessment of Corneal Epithelial Thickness in Asymmetric Keratoconic Eyes and Normal Eyes Using Fourier Domain Optical Coherence Tomography","volume":"2016","author":"Catalan","year":"2016","journal-title":"J Ophthalmol"},{"key":"2026091715575419900_r28","article-title":"Role of Corneal Epithelial Measurements in Differentiating Eyes with Stable Keratoconus from Eyes that Are Progressing","volume":"3","author":"Santhiago","year":"2022","journal-title":"Ophthalmol Sci"},{"key":"2026091715575419900_r29","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1016\/j.jcrs.2018.09.024","article-title":"Contribution of Fourier-domain optical coherence tomography to the diagnosis of keratoconus progression","volume":"45","author":"Ouanezar","year":"2019","journal-title":"J Cataract Refract Surg"},{"key":"2026091715575419900_r30","first-page":"756","article-title":"Pre-corneal tear film thickness in humans measured with a novel technique","volume":"17","author":"Azartash","year":"2011","journal-title":"Mol Vis"},{"key":"2026091715575419900_r31","doi-asserted-by":"crossref","first-page":"1988","DOI":"10.1167\/iovs.09-4389","article-title":"Ultrahigh-resolution measurement by optical coherence tomography of dynamic tear film changes on contact lenses","volume":"51","author":"Chen","year":"2010","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"2026091715575419900_r32","doi-asserted-by":"crossref","first-page":"62","DOI":"10.1097\/ICO.0000000000001745","article-title":"Evaluation of Corneal Epithelial Thickness Imaged by High Definition Optical Coherence Tomography in Healthy Eyes","volume":"38","author":"Baghdasaryan","year":"2019","journal-title":"Cornea"}],"container-title":["Molecular Vision"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/scholarlypublishingcollective.org\/molvis\/molecular-vision\/article-pdf\/doi\/10.63500\/mv_v32_143\/2462225\/mv_v32_143.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/scholarlypublishingcollective.org\/molvis\/molecular-vision\/article-pdf\/doi\/10.63500\/mv_v32_143\/2462225\/mv_v32_143.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,17]],"date-time":"2026-09-17T19:58:02Z","timestamp":1789675082000},"score":1,"resource":{"primary":{"URL":"https:\/\/scholarlypublishingcollective.org\/molecular-vision\/article\/doi\/10.63500\/mv_v32_143\/409732\/The-role-of-corneal-epithelial-thickness"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2,27]]},"references-count":32,"URL":"https:\/\/doi.org\/10.63500\/mv_v32_143","relation":{},"ISSN":["1090-0535"],"issn-type":[{"value":"1090-0535","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,2,27]]}}}