{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,27]],"date-time":"2026-10-27T10:09:31Z","timestamp":1793095771237,"version":"4.5.0"},"reference-count":20,"publisher":"MDPI AG","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,1]]},"abstract":"<jats:p>\n                    <jats:bold>Background:<\/jats:bold>\n                    The aim of this study was to create AO 44A1, 44B1, and 44C1 fractures using finite element analysis to determine the stability of Kirschner wire, intramedullary screw, and plate-screw fixation methods in fracture.\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:bold>Methods:<\/jats:bold>\n                    Using finite element analysis, the postreduction behavior of AO 44A1, 44B1, and 44C1 fractures with Kirschner wire, intramedullary screw, and plate-screw fixation methods was analyzed and compared in terms of displacement and stress.\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:bold>Results:<\/jats:bold>\n                    The lowest amount of displacement was provided with the intramedullary screw method in AO 44A1 and 44B1 fractures and with the 4-mm Kirschner wire method in AO 44C1 fractures. The total displacement of the intramedullary screw system used for fixation in AO 44A1, 44B1, and 44C1 fractures was lower.\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:bold>Conclusions:<\/jats:bold>\n                    According to finite element analysis results, the lowest amount of displacement was obtained with intramedullary screw fixation in AO 44A1 and 44B1 fractures, and 4-mm Kirschner wire fixation was achieved in AO 44C1 fractures.\n                  <\/jats:p>","DOI":"10.7547\/22-155","type":"journal-article","created":{"date-parts":[[2023,8,29]],"date-time":"2023-08-29T14:58:19Z","timestamp":1693321099000},"source":"Crossref","is-referenced-by-count":2,"title":["Computational Mechanical Analysis of AO 44A1, 44B1, and 44C1 Fractures with Finite Element Modeling: Evaluation of Screw, Plate, and Kirschner Wire Fixation"],"prefix":"10.3390","volume":"114","author":[{"given":"Hac\u0131 Ali","family":"Ol\u00e7ar","sequence":"first","affiliation":[{"name":"Department of Orthopaedics and Traumatology,Yozgat Bozok University, Yozgat,Turkey."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alaettin","family":"\u00d6zer","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Yozgat Bozok University, Yozgat, Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Halil Burak","family":"Mutu","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Tokat Gaziosmanpasa University, Tokat, Turkey."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"G\u00f6ker","family":"Yurdakul","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics and Traumatology, Sarikaya State Hospital, Yozgat, Turkey."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tolgahan","family":"Kuru","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics and Traumatology, \u00c7anakkale Onsekiz Mart University, \u00c7anakkale, Turkey."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Davut","family":"Ayd\u0131n","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics and Traumatology,Yozgat Bozok University, Yozgat,Turkey."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Murat","family":"Korkmaz","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics and Traumatology,Yozgat Bozok University, Yozgat,Turkey."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","reference":[{"key":"B1","series-title":"J Clin Orthop Trauma","first-page":"380","article-title":"Osteoporotic ankle fractures: a narrative review of management options","volume":"11","author":"Dhillon MS","year":"2020","unstructured":"Dhillon MS, Rajnish RK, Patel S, et al: Osteoporotic ankle fractures: a narrative review of management options. J Clin Orthop Trauma 11: 380, 2020."},{"key":"B2","series-title":"World J Orthop","first-page":"254","article-title":"Fibula fractures management","volume":"12","author":"Canton G","year":"2021","unstructured":"Canton G, Sborgia A, Maritan G, et al: Fibula fractures management. World J Orthop 12: 254, 2021."},{"key":"B3","series-title":"Int Orthop","first-page":"489","article-title":"The timing of ankle fracture surgery and the effect on infectious complications; a case series and systematic review of the literature","volume":"37","author":"Schepers T","year":"2013","unstructured":"Schepers T, De Vries MR, Van Lieshout EMM, et al: The timing of ankle fracture surgery and the effect on infectious complications; a case series and systematic review of the literature. Int Orthop 37: 489, 2013."},{"key":"B4","series-title":"J Orthop Traumatol","first-page":"245","article-title":"Intramedullary fixation of distal fibular fractures: a systematic review of clinical and functional outcomes","volume":"15","author":"Jain S","year":"2014","unstructured":"Jain S, Haughton BA, Brew C: Intramedullary fixation of distal fibular fractures: a systematic review of clinical and functional outcomes. J Orthop Traumatol 15: 245, 2014."},{"key":"B5","series-title":"J Pediatr Orthop","first-page":"E161","article-title":"Plate versus lag screw only fixation of unstable ankle fractures involving the fibula in adolescent patients","volume":"41","author":"Paez CJ","year":"2021","unstructured":"Paez CJ, Lurie BM, Bomar JD, et al: Plate versus lag screw only fixation of unstable ankle fractures involving the fibula in adolescent patients. J Pediatr Orthop 41: E161, 2021."},{"key":"B6","series-title":"J Foot Ankle Surg","first-page":"1081","article-title":"Percutaneous intramedullary screw fixation of distal fibula fractures: a case series and systematic review","volume":"56","author":"Loukachov VV","year":"2017","unstructured":"Loukachov VV, Birnie MFN, Dingemans SA, et al: Percutaneous intramedullary screw fixation of distal fibula fractures: a case series and systematic review. J Foot Ankle Surg 56: 1081, 2017."},{"key":"B7","series-title":"Zhongguo Gu Shang","first-page":"78","article-title":"Treatment of the distal fibula fractures with intramedullary Kirschner fixation [in Chinese]","volume":"26","author":"Wan S","year":"2013","unstructured":"Wan S, Hong Y, Tian JQ, et al: Treatment of the distal fibula fractures with intramedullary Kirschner fixation [in Chinese]. Zhongguo Gu Shang 26: 78, 2013."},{"key":"B8","series-title":"Int J Surg","first-page":"294","article-title":"The implants used for intramedullary fixation of distal fibula fractures: a review of literature","volume":"56","author":"Rehman H","year":"2018","unstructured":"Rehman H, Gardner WT, Rankin I, et al: The implants used for intramedullary fixation of distal fibula fractures: a review of literature. Int J Surg 56: 294, 2018."},{"key":"B9","series-title":"Foot Ankle Spec","first-page":"264","article-title":"Cannulated intramedullary screw fixation of distal fibular fractures","volume":"12","author":"Ebraheim NA","year":"2019","unstructured":"Ebraheim NA, Vander Maten JW, Delaney JR, et al: Cannulated intramedullary screw fixation of distal fibular fractures. Foot Ankle Spec 12: 264, 2019."},{"key":"B10","series-title":"J Clin Med","first-page":"2976","article-title":"Three-dimensional anatomically pre-contoured locking plate for isolated Weber B type fracture","volume":"10","author":"Kim J","year":"2021","unstructured":"Kim J, Chun D-I, Won S-H, et al: Three-dimensional anatomically pre-contoured locking plate for isolated Weber B type fracture. J Clin Med 10: 2976, 2021."},{"key":"B11","series-title":"J Am Acad Orthop Surg","first-page":"220","article-title":"Distal fibula malunions","volume":"17","author":"Chu A","year":"2009","unstructured":"Chu A, Weiner L: Distal fibula malunions. J Am Acad Orthop Surg 17: 220, 2009."},{"key":"B12","series-title":"Med Eng Phys","first-page":"61","article-title":"An improved method for the automatic mapping of computed tomography numbers onto finite element models","volume":"26","author":"Taddei F","year":"2004","unstructured":"Taddei F, Pancanti A, Viceconti M: An improved method for the automatic mapping of computed tomography numbers onto finite element models. Med Eng Phys 26: 61, 2004."},{"key":"B13","series-title":"Orthopedics","first-page":"e428","article-title":"Computerized virtual surgery planning for ORIF of proximal humeral fractures","volume":"38","author":"Xia S","year":"2015","unstructured":"Xia S, Zhang Y, Wang X, et al: Computerized virtual surgery planning for ORIF of proximal humeral fractures. Orthopedics 38: e428, 2015."},{"key":"B14","series-title":"Injury","first-page":"562","article-title":"Is the fracture morphology in the sagittal plane important in determining the ideal placement of the lag screw in intertrochanteric femoral fractures? ideal lag screw placement in intertrochanteric fractures in the sagittal plane","volume":"52","author":"\u00d6ner K","year":"2021","unstructured":"\u00d6ner K, Durusoy S, \u00d6zer A: Is the fracture morphology in the sagittal plane important in determining the ideal placement of the lag screw in intertrochanteric femoral fractures? ideal lag screw placement in intertrochanteric fractures in the sagittal plane. Injury 52: 562, 2021."},{"key":"B15","series-title":"J Clin Orthop Trauma","first-page":"136","article-title":"Intramedullary fixation of fibula fractures: a systematic review","volume":"18","author":"B\u00e4cker HC","year":"2021","unstructured":"B\u00e4cker HC, Vosseller JT: Intramedullary fixation of fibula fractures: a systematic review. J Clin Orthop Trauma 18: 136, 2021."},{"key":"B16","series-title":"J Clin Orthop Trauma","first-page":"327","article-title":"Antiglide versus lateral plate fixation for Danis-Weber type B malleolar fractures caused by supination-external rotation injury","volume":"8","author":"Kilian M","year":"2017","unstructured":"Kilian M, Cs\u00f6rg\u00f6 P, Vajczikova S, et al: Antiglide versus lateral plate fixation for Danis-Weber type B malleolar fractures caused by supination-external rotation injury. J Clin Orthop Trauma 8: 327, 2017."},{"key":"B17","series-title":"J Orthop Surg Res","first-page":"230","article-title":"Is double-strut fibula ankle arthrodesis a reliable reconstruction for bone defect after distal tibia tumor resection? a finite element study based on promising clinical outcomes","volume":"16","author":"Zhao Z","year":"2021","unstructured":"Zhao Z, Yan T, Guo W, et al: Is double-strut fibula ankle arthrodesis a reliable reconstruction for bone defect after distal tibia tumor resection? a finite element study based on promising clinical outcomes. J Orthop Surg Res 16: 230, 2021."},{"issue":"suppl","key":"B18","series-title":"Clin Orthop Relat Res","first-page":"S132","article-title":"Effects of mechanical factors on the fracture healing process","volume":"355","author":"Claes LE","year":"1998","unstructured":"Claes LE, Heigele CA, Neidlinger-Wilke C, et al: Effects of mechanical factors on the fracture healing process. Clin Orthop Relat Res 355\u2009(suppl): S132, 1998."},{"key":"B19","series-title":"Int Orthop","first-page":"2127","article-title":"Lateral malleolar fractures Weber Type A and B: does percutaneous intramedullary screw confer a solid alternative to the traditional neutralization plate?","volume":"46","author":"Zawam SH","year":"2022","unstructured":"Zawam SH, Mabrouk MG, El-Desouky MA: Lateral malleolar fractures Weber Type A and B: does percutaneous intramedullary screw confer a solid alternative to the traditional neutralization plate? Int Orthop 46: 2127, 2022."},{"key":"B20","series-title":"Int Orthop","first-page":"695","article-title":"Stabilisation of the fractured fibula plays an important role in the treatment of pilon fractures: a retrospective comparison of fibular fixation methods","volume":"33","author":"Lee YS","year":"2009","unstructured":"Lee YS, Chen SW, Chen SH, et al: Stabilisation of the fractured fibula plays an important role in the treatment of pilon fractures: a retrospective comparison of fibular fixation methods. Int Orthop 33: 695, 2009."}],"container-title":["Journal of the American Podiatric Medical Association"],"original-title":[],"link":[{"URL":"https:\/\/japmaonline.org\/view\/journals\/apms\/114\/1\/22-155.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/japmaonline.org\/downloadpdf\/journals\/apms\/114\/1\/22-155.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/japmaonline.org\/downloadpdf\/journals\/apms\/114\/1\/22-155.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,8]],"date-time":"2026-07-08T10:19:34Z","timestamp":1783505974000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1930-8264\/114\/1\/22155"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,1]]},"references-count":20,"journal-issue":{"issue":"1"},"URL":"https:\/\/doi.org\/10.7547\/22-155","relation":{},"ISSN":["8750-7315"],"issn-type":[{"value":"8750-7315","type":"print"}],"subject":[],"published":{"date-parts":[[2024,1]]}}}