{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,30]],"date-time":"2026-07-30T10:13:57Z","timestamp":1785406437159,"version":"3.56.0"},"reference-count":44,"publisher":"eLife Sciences Publications, Ltd","license":[{"start":{"date-parts":[[2023,12,14]],"date-time":"2023-12-14T00:00:00Z","timestamp":1702512000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2023,12,14]],"date-time":"2023-12-14T00:00:00Z","timestamp":1702512000000},"content-version":"am","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2023,12,14]],"date-time":"2023-12-14T00:00:00Z","timestamp":1702512000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/100000002","name":"National Institutes of Health","doi-asserted-by":"crossref","award":["R01AR075077"],"award-info":[{"award-number":["R01AR075077"]}],"id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"crossref"}]},{"DOI":"10.13039\/100000002","name":"National Institutes of Health","doi-asserted-by":"crossref","award":["R01EB029818"],"award-info":[{"award-number":["R01EB029818"]}],"id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["elifesciences.org"],"crossmark-restriction":false},"short-container-title":[],"abstract":"<jats:p>One limitation on the ability to monitor health in older adults using magnetic resonance (MR) imaging is the presence of implants, where the prevalence of implantable devices (orthopedic, cardiac, neuromodulation) increases in the population, as does the pervasiveness of conditions requiring MRI studies for diagnosis (musculoskeletal diseases, infections, or cancer). The present study describes a novel multiphysics implant modeling testbed using the following approaches with two examples: (1) an in silico human model based on the widely available Visible Human Project (VHP) cryo-section dataset; (2) a finite element method (FEM) modeling software workbench from Ansys (Electronics Desktop\/Mechanical) to model MR radio frequency (RF) coils and the temperature rise modeling in heterogeneous media. The in silico VHP-Female model (250 parts with an additional 40 components specifically characterizing embedded implants and resultant surrounding tissues) corresponds to a 60-year-old female with a body mass index of 36. The testbed includes the FEM-compatible in silico human model, an implant embedding procedure, a generic parameterizable MRI RF birdcage two-port coil model, a workflow for computing heat sources on the implant surface and in adjacent tissues, and a thermal FEM solver directly linked to the MR coil simulator to determine implant heating based on an MR imaging study protocol. The primary target is MR labeling of large orthopedic implants. The testbed has very recently been approved by the US Food and Drug Administration (FDA) as a medical device development tool for 1.5 T orthopedic implant examinations.<\/jats:p>","DOI":"10.7554\/elife.90440","type":"journal-article","created":{"date-parts":[[2023,9,15]],"date-time":"2023-09-15T10:06:32Z","timestamp":1694772392000},"update-policy":"https:\/\/doi.org\/10.7554\/elife.90440","source":"Crossref","is-referenced-by-count":1,"title":["An in silico testbed for fast and accurate MR labeling of orthopedic implants"],"prefix":"10.7554","volume":"12","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9786-7206","authenticated-orcid":true,"given":"Gregory M","family":"Noetscher","sequence":"first","affiliation":[{"id":[{"id":"https:\/\/ror.org\/05ejpqr48","id-type":"ROR","asserted-by":"publisher"}],"name":"Electrical & Computer Eng. Dept, Worcester Polytechnic Institute","place":["Worcester, United States"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter J","family":"Serano","sequence":"first","affiliation":[{"id":[{"id":"https:\/\/ror.org\/05cf5b117","id-type":"ROR","asserted-by":"publisher"}],"name":"Ansys","place":["Canonsburg, United States"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2483-5796","authenticated-orcid":true,"given":"Marc","family":"Horner","sequence":"additional","affiliation":[{"id":[{"id":"https:\/\/ror.org\/05cf5b117","id-type":"ROR","asserted-by":"publisher"}],"name":"Ansys","place":["Canonsburg, United States"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexander","family":"Prokop","sequence":"additional","affiliation":[{"id":[{"id":"https:\/\/ror.org\/01mw2b749","id-type":"ROR","asserted-by":"publisher"}],"name":"Dassault Syst\u00e8mes Deutschland GmbH","place":["Darmstadt, Germany"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jonathan","family":"Hanson","sequence":"additional","affiliation":[{"name":"Neva Electromagnetics, LLC","place":["Holden, United States"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kyoko","family":"Fujimoto","sequence":"additional","affiliation":[{"name":"GE HealthCare","place":["Chicago, United States"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"James","family":"Brown","sequence":"additional","affiliation":[{"id":[{"id":"https:\/\/ror.org\/00fgrre84","id-type":"ROR","asserted-by":"publisher"}],"name":"Micro Systems Enigineering, Inc, an affiliate of Biotronik","place":["Lake Oswego, United States"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ara","family":"Nazarian","sequence":"additional","affiliation":[{"id":[{"id":"https:\/\/ror.org\/04drvxt59","id-type":"ROR","asserted-by":"publisher"}],"name":"Musculoskeletal Translational Innovation Initiative, Department of Orthopedic Surgery, Beth Israel Deaconess Medical Center and Harvard Medical School","place":["Boston, United States"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5176-7496","authenticated-orcid":true,"given":"Jerome","family":"Ackerman","sequence":"additional","affiliation":[{"name":"Harvard Medical School","place":["Boston, United States"]},{"id":[{"id":"https:\/\/ror.org\/002pd6e78","id-type":"ROR","asserted-by":"publisher"}],"name":"Athinoula A Martinos Center for Biomed. Imaging, Massachusetts General Hospital","place":["Charlestown, United States"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sergey N","family":"Makaroff","sequence":"additional","affiliation":[{"id":[{"id":"https:\/\/ror.org\/05ejpqr48","id-type":"ROR","asserted-by":"publisher"}],"name":"Electrical & Computer Eng. Dept, Worcester Polytechnic Institute","place":["Worcester, United States"]},{"id":[{"id":"https:\/\/ror.org\/002pd6e78","id-type":"ROR","asserted-by":"publisher"}],"name":"Athinoula A Martinos Center for Biomed. Imaging, Massachusetts General Hospital","place":["Charlestown, United States"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"4374","published-online":{"date-parts":[[2023,12,14]]},"reference":[{"key":"bib1","doi-asserted-by":"publisher","first-page":"504","DOI":"10.1109\/5.662875","article-title":"The Visible Human Project","volume":"86","author":"Ackerman","year":"1998","journal-title":"Proceedings of the IEEE"},{"key":"bib2","doi-asserted-by":"publisher","first-page":"559","DOI":"10.1016\/j.mric.2020.07.008","article-title":"Practical Aspects of MR Imaging Safety Test Methods for MR Conditional Active Implantable Medical Devices","volume":"28","author":"Al-Dayeh","year":"2020","journal-title":"Magnetic Resonance Imaging Clinics of North America"},{"key":"bib3","article-title":"ACR Manual on MR Safety","author":"American College of Radiology","year":"2020","unstructured":"American College of Radiology. 2020. ACR Manual on MR Safety. https:\/\/www.acr.org\/-\/media\/ACR\/Files\/Radiology-Safety\/MR-Safety\/Manual-on-MR-Safety.pdf [Accessed July 18, 2023]."},{"key":"bib4","doi-asserted-by":"publisher","first-page":"3447","DOI":"10.1002\/mrm.28666","article-title":"Heating of hip joint implants in MRI: The combined effect of RF and switched-gradient fields","volume":"85","author":"Arduino","year":"2021","journal-title":"Magnetic Resonance in Medicine"},{"key":"bib5","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/aca5e6","article-title":"Computational dosimetry in MRI in presence of hip, knee or shoulder implants: do we need accurate surgery models?","volume":"67","author":"Arduino","year":"2022","journal-title":"Physics in Medicine and Biology"},{"key":"bib6","doi-asserted-by":"publisher","first-page":"930","DOI":"10.1002\/mrm.29235","article-title":"A contribution to MRI safety testing related to gradient-induced heating of medical devices","volume":"88","author":"Arduino","year":"2022","journal-title":"Magnetic Resonance in Medicine"},{"key":"bib7","doi-asserted-by":"publisher","first-page":"1197","DOI":"10.1002\/jmri.28321","article-title":"Parameters affecting worst-case gradient-field heating of passive conductive implants","volume":"56","author":"Bassen","year":"2022","journal-title":"Journal of Magnetic Resonance Imaging"},{"key":"bib8","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-030-21293-3_1","volume-title":"Brain and Human Body Modeling: Computational Human Modeling at EMBC 2018","author":"Brown","year":"2019"},{"key":"bib9","volume-title":"Computer Modeling and Simulation of Implantable Medical Device Heating due to MRI Gradient Coil Field","author":"Bryan David Stem","year":"2014"},{"key":"bib10","doi-asserted-by":"publisher","DOI":"10.3390\/diagnostics12081873","article-title":"Classification scheme of heating risk during MRI scans on patients with orthopaedic prostheses","volume":"12","author":"Clementi","year":"2022","journal-title":"Diagnostics"},{"key":"bib11","doi-asserted-by":"publisher","first-page":"198","DOI":"10.7150\/jbji.35428","article-title":"Prosthetic-joint infections: mortality over the Last 10 years","volume":"4","author":"Fischbacher","year":"2019","journal-title":"Journal of Bone and Joint Infection"},{"key":"bib12","article-title":"Retrospective analysis of radio-frequency safety of orthopedic passive implantable device","volume":"28","author":"Fujimoto","year":"2020","journal-title":"Proceedings of the International Society for Magnetic Resonance in Medicine"},{"key":"bib13","doi-asserted-by":"publisher","first-page":"98","DOI":"10.1148\/radiol.2020191901","article-title":"Diagnosis of periprosthetic hip joint infection using MRI with Metal Artifact Reduction at 1.5 T","volume":"296","author":"Galley","year":"2020","journal-title":"Radiology"},{"key":"bib14","doi-asserted-by":"publisher","first-page":"5287","DOI":"10.1088\/0031-9155\/59\/18\/5287","article-title":"Development of a new generation of high-resolution anatomical models for medical device evaluation: the virtual population 3.0","volume":"59","author":"Gosselin","year":"2014","journal-title":"Physics in Medicine and Biology"},{"key":"bib15","doi-asserted-by":"publisher","first-page":"417","DOI":"10.1109\/TMI.2017.2753739","article-title":"Magnetic resonance mediated radiofrequency ablation","volume":"37","author":"Hue","year":"2018","journal-title":"IEEE Transactions on Medical Imaging"},{"key":"bib16","article-title":"Three Class III Obese ViP Models for Improved Patient Coverage","author":"IT\u2019IS Foundation","year":"2023","unstructured":"IT\u2019IS Foundation. 2023. Three Class III Obese ViP Models for Improved Patient Coverage. https:\/\/itis.swiss\/news-events\/news\/virtual-population\/class-iii-obese-models\/ [Accessed July 18, 2023]."},{"key":"bib17","volume-title":"Scanning Patients with MR Conditional Implants","author":"Kanal","year":"2015"},{"key":"bib18","doi-asserted-by":"publisher","first-page":"7913","DOI":"10.1109\/EMBC.2015.7320227","article-title":"Comparative analysis of different hip implants within a realistic human model located inside a 1.5T MRI whole body RF coil","volume":"2015","author":"Kozlov","year":"2015","journal-title":"Annual International Conference of the IEEE Engineering in Medicine and Biology Society"},{"key":"bib19","doi-asserted-by":"publisher","first-page":"1616","DOI":"10.2106\/JBJS.18.00583","article-title":"What\u2019s new in hip replacement","volume":"100","author":"Li","year":"2018","journal-title":"The Journal of Bone and Joint Surgery. American Volume"},{"key":"bib20","doi-asserted-by":"publisher","first-page":"143","DOI":"10.15420\/aer.2019.3.4","article-title":"Implantable cardiac electronic devices in the elderly population","volume":"8","author":"Lim","year":"2019","journal-title":"Arrhythmia & Electrophysiology Review"},{"key":"bib21","doi-asserted-by":"publisher","first-page":"95","DOI":"10.1109\/RBME.2017.2722420","article-title":"Virtual human models for electromagnetic studies and their applications","volume":"10","author":"Makarov","year":"2017","journal-title":"IEEE Reviews in Biomedical Engineering"},{"key":"bib22","doi-asserted-by":"publisher","first-page":"79","DOI":"10.2463\/mrms.5.79","article-title":"Evaluation of RF heating on humerus implant in phantoms during 1.5T MR imaging and comparisons with electromagnetic simulation","volume":"5","author":"Muranaka","year":"2006","journal-title":"Magnetic Resonance in Medical Sciences"},{"key":"bib23","doi-asserted-by":"publisher","first-page":"199","DOI":"10.2463\/mrms.6.199","article-title":"Dependence of RF heating on SAR and implant position in a 1.5T MR system","volume":"6","author":"Muranaka","year":"2007","journal-title":"Magnetic Resonance in Medical Sciences"},{"key":"bib24","doi-asserted-by":"publisher","first-page":"11","DOI":"10.2463\/mrms.10.11","article-title":"Evaluation of RF heating due to various implants during MR procedures","volume":"10","author":"Muranaka","year":"2011","journal-title":"Magnetic Resonance in Medical Sciences"},{"key":"bib25","article-title":"VHP-Female 2.2 (College)","author":"NEVA Electromagnetics, LLC","year":"2015","unstructured":"NEVA Electromagnetics, LLC. 2015. VHP-Female 2.2 (College). https:\/\/www.nevaelectromagnetics.com\/vhp-female-2-2 [Accessed July 18, 2023]."},{"key":"bib26","article-title":"FDA MDDT: Computational Tool Comprising Visible Human Project Based Anatomical Female CAD Model and Ansys HFSS\/Mechanical FEM Software for Temperature Rise Prediction near an Orthopedic Femoral Nail Implant during a 1.5 T MRI Scan","author":"Neva Electromagnetics, LLC","year":"2022","unstructured":"Neva Electromagnetics, LLC. 2022. FDA MDDT: Computational Tool Comprising Visible Human Project Based Anatomical Female CAD Model and Ansys HFSS\/Mechanical FEM Software for Temperature Rise Prediction near an Orthopedic Femoral Nail Implant during a 1.5 T MRI Scan. https:\/\/www.fda.gov\/media\/166724\/download [Accessed July 18, 2023]."},{"key":"bib27","doi-asserted-by":"publisher","first-page":"309","DOI":"10.1007\/978-3-030-45623-8_19","volume-title":"Brain and Human Body Modeling 2020","author":"Noetscher","year":"2021"},{"key":"bib28","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0260922","article-title":"Visible Human Project female surface based computational phantom (Nelly) for radio-frequency safety evaluation in MRI coils","volume":"16","author":"Noetscher","year":"2021","journal-title":"PLOS ONE"},{"key":"bib29","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-031-15451-5_9","volume-title":"Brain and Human Body Modelling 2021","author":"Noetscher","year":"2023"},{"key":"bib30","article-title":"MDDT Summary of Evidence and Basis of Qualification Decision for IMANALYTICS with MRIXVIP1.5T\/3.0T and BCLIB. ZMT Zurich MedTech AG, Zurich, Switzerland. 12\/4\/2020. FDA. Doc ID 01147.02.00","author":"Oberle","year":"2021","unstructured":"Oberle M. 2021. MDDT Summary of Evidence and Basis of Qualification Decision for IMANALYTICS with MRIXVIP1.5T\/3.0T and BCLIB. ZMT Zurich MedTech AG, Zurich, Switzerland. 12\/4\/2020. FDA. Doc ID 01147.02.00. https:\/\/www.fda.gov\/media\/148922\/download [Accessed July 18, 2023]."},{"key":"bib31","article-title":"In-Silico Testbed for MR Labeling of Orthopaedic Implants based on open-source VHP-Female 2.2 College","author":"Online Dropbox","year":"2023","unstructured":"Online Dropbox. 2023. In-Silico Testbed for MR Labeling of Orthopaedic Implants based on open-source VHP-Female 2.2 College. https:\/\/www.dropbox.com\/sh\/6v1a33ojdrw95y0\/AABFJwifTUy-RzNWtZSroTo5a?dl=0 [Accessed June 1, 2023]."},{"key":"bib32","volume-title":"StatPearls","author":"Puette","year":"2022"},{"key":"bib33","doi-asserted-by":"publisher","first-page":"26","DOI":"10.1148\/radiol.2531091030","article-title":"MR labeling information for implants and devices: explanation of terminology","volume":"253","author":"Shellock","year":"2009","journal-title":"Radiology"},{"key":"bib34","volume-title":"Joint Replacement Infection","author":"Sheth","year":"2023"},{"key":"bib35","doi-asserted-by":"publisher","first-page":"2726","DOI":"10.1002\/mrm.27346","article-title":"Retrospective analysis of RF heating measurements of passive medical implants","volume":"80","author":"Song","year":"2018","journal-title":"Magnetic Resonance in Medicine"},{"key":"bib36","doi-asserted-by":"publisher","first-page":"118","DOI":"10.1136\/jamia.1996.96236280","article-title":"The visible human male: A technical report","volume":"3","author":"Spitzer","year":"1996","journal-title":"Journal of the American Medical Informatics Association"},{"key":"bib37","article-title":"Testing and Labeling Medical Devices for Safety in the Magnetic Resonance (MR) Environment","author":"US Department of Health and Human Services","year":"2021","unstructured":"US Department of Health and Human Services, Food and Drug Administration, Center for Devices and Radiological Health. 2021. Testing and Labeling Medical Devices for Safety in the Magnetic Resonance (MR) Environment. https:\/\/www.fda.gov\/media\/74201\/download [Accessed July 18, 2023]."},{"key":"bib38","volume-title":"Medical Device Development Tool MDDT Q170004 Communications with FDA Center for Devices and Radiological Health","author":"US Food and Drug Administration","year":"2022","unstructured":"US Food and Drug Administration. 2022. Silver Spring. Medical Device Development Tool MDDT Q170004 Communications with FDA Center for Devices and Radiological Health."},{"key":"bib39","article-title":"Understanding MRI Safety Labeling","author":"US Food and Drug Administration","year":"2023","unstructured":"US Food and Drug Administration. 2023a. Understanding MRI Safety Labeling. https:\/\/www.fda.gov\/media\/101221\/download [Accessed July 18, 2023]."},{"key":"bib40","article-title":"FDA 510(k)\/De Novo Clearance and Premarket Approval Applications","author":"US Food and Drug Administration","year":"2023","unstructured":"US Food and Drug Administration. 2023b. FDA 510(k)\/De Novo Clearance and Premarket Approval Applications. https:\/\/www.accessdata.fda.gov\/scripts\/cdrh\/cfdocs\/search\/default.cfm [Accessed July 18, 2023]."},{"key":"bib41","doi-asserted-by":"publisher","first-page":"1646","DOI":"10.1002\/jmri.27194","article-title":"MRI-Related Heating of Implants and Devices: A Review","volume":"53","author":"Winter","year":"2021","journal-title":"Journal of Magnetic Resonance Imaging"},{"key":"bib42","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ac3eab","article-title":"Gradient coil and radiofrequency induced heating of orthopaedic implants in MRI: influencing factors","volume":"66","author":"Wooldridge","year":"2021","journal-title":"Physics in Medicine and Biology"},{"key":"bib43","doi-asserted-by":"publisher","DOI":"10.1109\/EuCAP.2016.7481298","article-title":"Multi-purpose VHP-female version 3.0 cross-platform computational human model","author":"Yanamadala","year":"2016","unstructured":"Yanamadala J, Noetscher GM, Louie S, Prokop A, Kozlov M, Nazarian A, Makarov SN. 2016. Multi-purpose VHP-female version 3.0 cross-platform computational human model. 10th European Conference on Antennas and Propagation."},{"key":"bib44","doi-asserted-by":"publisher","first-page":"109","DOI":"10.1148\/radiol.2020201419","article-title":"The Expanding Role of MRI in the Evaluation of Periprosthetic Hip Joint Infection","volume":"296","author":"Zanetti","year":"2020","journal-title":"Radiology"}],"container-title":["eLife"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/cdn.elifesciences.org\/articles\/90440\/elife-90440-v1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/cdn.elifesciences.org\/articles\/90440\/elife-90440-v1.xml","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/elifesciences.org\/articles\/90440","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,12,15]],"date-time":"2023-12-15T04:28:51Z","timestamp":1702614531000},"score":1,"resource":{"primary":{"URL":"https:\/\/elifesciences.org\/articles\/90440"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,12,14]]},"references-count":44,"alternative-id":["10.7554\/eLife.90440"],"URL":"https:\/\/doi.org\/10.7554\/elife.90440","archive":["CLOCKSS"],"relation":{"has-preprint":[{"id-type":"doi","id":"10.7554\/eLife.90440.2","asserted-by":"subject"},{"id-type":"doi","id":"10.1101\/2023.07.16.549234","asserted-by":"subject"}],"is-same-as":[{"id-type":"doi","id":"10.7554\/eLife.90440.3","asserted-by":"subject"}],"is-version-of":[{"id-type":"doi","id":"10.7554\/eLife.90440.1","asserted-by":"subject"},{"id-type":"doi","id":"10.7554\/eLife.90440.2","asserted-by":"subject"}]},"ISSN":["2050-084X"],"issn-type":[{"value":"2050-084X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,12,14]]},"assertion":[{"value":"single anonymised","name":"peer_review_transparency","label":"Peer review transparency","group":{"name":"peer_review_taxonomy"}},{"value":"other reviewer(s), editor","name":"peer_review_interaction","label":"Peer review interaction","group":{"name":"peer_review_taxonomy"}},{"value":"review summaries, review reports, author\/editor communication, reviewer identities reviewer opt in, editor identities","name":"peer_review_published","label":"Peer review published","group":{"name":"peer_review_taxonomy"}},{"value":"open (sign in with ORCID iD required)","name":"post_publication_commenting","label":"Post publication commenting","group":{"name":"post_publication_commenting"}}],"article-number":"RP90440"}}