{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,14]],"date-time":"2026-06-14T11:47:53Z","timestamp":1781437673136,"version":"3.54.1"},"reference-count":15,"publisher":"Walter de Gruyter GmbH","issue":"9","license":[{"start":{"date-parts":[[2016,9,1]],"date-time":"2016-09-01T00:00:00Z","timestamp":1472688000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2016,9,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>\n                  <jats:bold>Background:<\/jats:bold> The 3-piece inflatable penile prosthesis was introduced in 1973 as a treatment for men with erectile dysfunction. Consisting of 2 corporal cylinders, 1 pump, and a fluid-filled reservoir, the prosthesis is placed by blunt dissection into the retropubic space. The dissection for the reservoir is performed blindly into a space juxtaposed with nerves, vessels, and the bladder.<\/jats:p>\n               <jats:p>\n                  <jats:bold>Objective:<\/jats:bold> To propose a novel approach for inflatable penile prosthesis reservoir placement involving gentle dilation of the retropubic space using a Foley catheter balloon.<\/jats:p>\n               <jats:p>\n                  <jats:bold>Methods:<\/jats:bold> Patient medical records from 1 surgeon were reviewed. Patients did not have a history of pelvic surgery or prostatectomy. Each implant was approached using a penoscrotal incision, and the retropubic space was dilated with a 30-mL Foley catheter balloon filled to 100-mL capacity before reservoir placement. The postoperative visits were examined for complications, including reservoir infection and herniation. A literature search of penile prosthesis reservoir placement technique and complications (eg, herniation, infection) of reservoir placement was also performed.<\/jats:p>\n               <jats:p>\n                  <jats:bold>Results:<\/jats:bold> Fifteen patient records were examined. The reservoir herniation rate was 0% and the infection rate was 7%. The average reservoir herniation rate is reported to be 1% to 3%, and the average infection rate is reported to be 1% to 5%.<\/jats:p>\n               <jats:p>\n                  <jats:bold>Conclusion:<\/jats:bold> The use of a Foley catheter balloon is a safe, atraumatic, cost-effective, and easily performed method of dilating the retropubic space for subsequent inflatable penile prosthesis reservoir placement.<\/jats:p>","DOI":"10.7556\/jaoa.2016.118","type":"journal-article","created":{"date-parts":[[2016,8,29]],"date-time":"2016-08-29T13:33:59Z","timestamp":1472477639000},"page":"594-598","source":"Crossref","is-referenced-by-count":2,"title":["Retropubic Dilation With a Foley Catheter Balloon: A Novel Technique for Penile Prosthesis Reservoir Placement"],"prefix":"10.1515","volume":"116","author":[{"given":"Nicole M.","family":"Szell","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gregory V.","family":"McIntosh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anthony D.","family":"DiMatteo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Todd","family":"Campbell","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael K.","family":"Shaw","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"374","published-online":{"date-parts":[[2016,9,1]]},"reference":[{"key":"2022022616531577791_j_jaoa.2016.118_ref_001","doi-asserted-by":"crossref","first-page":"80","DOI":"10.1016\/0090-4295(73)90224-0","article-title":"Management of erectile impotence: use of implantable inflatable prosthesis","volume":"2","author":"Scott","year":"1973","journal-title":"Urology"},{"key":"2022022616531577791_j_jaoa.2016.118_ref_002","doi-asserted-by":"crossref","first-page":"707321","DOI":"10.1155\/2012\/707321","article-title":"Contemporary patient satisfaction rates for three-piece inflatable penile prostheses","volume":"2012","author":"Bernal","year":"2012","journal-title":"Adv Urol"},{"issue":"1","key":"2022022616531577791_j_jaoa.2016.118_ref_003","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1097\/01.ju.0000072524.82345.6d","article-title":"Comparison of satisfaction rates and erectile function in patients treated with sildenafil, intracavernous prostaglandin e1 and penile implant surgery for erectile dysfunction in urology practice","volume":"170","author":"Rajpurkar","year":"2003","journal-title":"J Urol"},{"issue":"1","key":"2022022616531577791_j_jaoa.2016.118_ref_004","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1016\/S0090-4295(00)00864-5","article-title":"Reservoir herniation as a complication of three-piece penile prosthesis insertion","volume":"57","author":"Sadeghi-Nejad","year":"2001","journal-title":"Urology"},{"key":"2022022616531577791_j_jaoa.2016.118_ref_005","first-page":"617","article-title":"Complications of surgery for erectile dysfunction and Peyronie\u2019s disease","volume-title":"Complications of Urologic Surgery","author":"Bennett","year":"2010","edition":"4th ed."},{"issue":"1","key":"2022022616531577791_j_jaoa.2016.118_ref_006","doi-asserted-by":"crossref","first-page":"98","DOI":"10.1111\/j.1743-6109.2004.10115.x","article-title":"The penile implant for erectile dysfunction","volume":"1","author":"Mulcahy","year":"2004","journal-title":"J Sex Med"},{"issue":"6","key":"2022022616531577791_j_jaoa.2016.118_ref_007","doi-asserted-by":"crossref","first-page":"1310","DOI":"10.1016\/j.urology.2011.11.076","article-title":"Coated implants and \u201cno touch\u201d surgical technique decreases risk of infection in inflatable penile prosthesis implantation to 0.46%","volume":"79","author":"Eid","year":"2012","journal-title":"Urology"},{"issue":"2","key":"2022022616531577791_j_jaoa.2016.118_ref_008","doi-asserted-by":"crossref","first-page":"467","DOI":"10.1111\/j.1464-410X.2007.06732.x","article-title":"Surgical atlas: insertion of an inflatable penile prosthesis","volume":"99","author":"Anderson","year":"2007","journal-title":"Br J U Int"},{"issue":"11","key":"2022022616531577791_j_jaoa.2016.118_ref_009","doi-asserted-by":"crossref","first-page":"2759","DOI":"10.1111\/j.1743-6109.2012.02807.x","article-title":"Review of penile prosthetic reservoir: complications and presentation of a modified reservoir placement technique","volume":"9","author":"Levine","year":"2012","journal-title":"J Sex Med"},{"issue":"1","key":"2022022616531577791_j_jaoa.2016.118_ref_010","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1016\/S0022-5347(17)32839-2","article-title":"Facilitated implantation of the inguinal reservoir of the multicomponent inflatable penile prosthesis","volume":"152","author":"Hirsch","year":"1994","journal-title":"J Urol"},{"issue":"6","key":"2022022616531577791_j_jaoa.2016.118_ref_011","doi-asserted-by":"crossref","first-page":"792","DOI":"10.1111\/j.1464-410X.1995.tb07393.x","article-title":"Radial dilatation in the insertion of the multi-component inflatable penile prosthesis","volume":"75","author":"Hirsch","year":"1995","journal-title":"Br J Urol"},{"issue":"4 pt 1","key":"2022022616531577791_j_jaoa.2016.118_ref_012","doi-asserted-by":"crossref","first-page":"1475","DOI":"10.1097\/00005392-200210010-00041","article-title":"The mentor alpha 1 penile prosthesis with reservoir lock-out valve: effective prevention of auto-inflation with improved capability for ectopic reservoir placement","volume":"168","author":"Wilson","year":"2002","journal-title":"J Urol"},{"issue":"3","key":"2022022616531577791_j_jaoa.2016.118_ref_013","doi-asserted-by":"crossref","first-page":"656","DOI":"10.1111\/j.1743-6109.2011.02202.x","article-title":"Traditional (retroperitoneal) and abdominal wall (ectopic) reservoir placement","volume":"8","author":"Perito","year":"2011","journal-title":"J Sex Med"},{"issue":"2","key":"2022022616531577791_j_jaoa.2016.118_ref_014","doi-asserted-by":"crossref","first-page":"664","DOI":"10.1097\/01.ju.0000131454.51640.a3","article-title":"Fate of the retained reservoir after replacement of 3-piece penile prosthesis","volume":"172","author":"Rajpurkar","year":"2004","journal-title":"J Urol"},{"issue":"8","key":"2022022616531577791_j_jaoa.2016.118_ref_015","doi-asserted-by":"crossref","first-page":"2175","DOI":"10.1111\/j.1743-6109.2012.02813.x","article-title":"Inflatable penile prosthesis and salvage protocol for mechanical failure: is it really necessary?","volume":"9","author":"Bartley","year":"2012","journal-title":"J Sex Med"}],"container-title":["Journal of Osteopathic Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.degruyter.com\/document\/doi\/10.7556\/jaoa.2016.118\/xml","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.degruyter.com\/document\/doi\/10.7556\/jaoa.2016.118\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,2,26]],"date-time":"2022-02-26T16:53:29Z","timestamp":1645894409000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.degruyter.com\/document\/doi\/10.7556\/jaoa.2016.118\/html"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,9,1]]},"references-count":15,"journal-issue":{"issue":"9","published-online":{"date-parts":[[2016,9,1]]},"published-print":{"date-parts":[[2016,9,1]]}},"alternative-id":["10.7556\/jaoa.2016.118"],"URL":"https:\/\/doi.org\/10.7556\/jaoa.2016.118","relation":{},"ISSN":["2702-3648"],"issn-type":[{"value":"2702-3648","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,9,1]]}}}