{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,12]],"date-time":"2026-10-12T12:22:50Z","timestamp":1791807770110,"version":"4.3.4"},"reference-count":17,"publisher":"Instituto Nacional de Salud (Colombia)","issue":"4","license":[{"start":{"date-parts":[[2025,9,22]],"date-time":"2025-09-22T00:00:00Z","timestamp":1758499200000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,9,22]],"date-time":"2025-09-22T00:00:00Z","timestamp":1758499200000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["revistabiomedica.org"],"crossmark-restriction":false},"short-container-title":["Biomed."],"abstract":"<jats:p>Introducci\u00f3n. Tradicionalmente, la s\u00edfilis se ha detectado con pruebas no trepon\u00e9micas y se ha confirmado con pruebas trepon\u00e9micas, un algoritmo diagn\u00f3stico implementado a nivel mundial.Objetivo. Evaluar el desempe\u00f1o de las pruebas trepon\u00e9micas y no trepon\u00e9micas para detectar en forma efectiva la s\u00edfilis entre los donantes de sangre.Materiales y m\u00e9todos. Se realiz\u00f3 un estudio transversal con 384 muestras, inicialmente reactivas para s\u00edfilis seg\u00fan los resultados de pruebas no trepon\u00e9micas. Posteriormente, se reevaluaron todas las muestras mediante VDRL, ELISA, CLIA y FTA-ABS, esta \u00faltima como prueba confirmatoria. Se calcul\u00f3 el coeficiente kappa para determinar la concordancia entre las pruebas no trepon\u00e9micas y se estimaron los \u00edndices de desempe\u00f1o. Resultados. Se determin\u00f3 la concordancia entre las pruebas no trepon\u00e9micas y las trepon\u00e9micas. Entre la VDRL y ELISA, fue del 78,8 %, mientras que, entre la VDRL y el CLIA, fue del 76 % (p &lt; 0,005). La concordancia entre el ELISA y el CLIA fue del 83 %. Al comparar los resultados obtenidos en las pruebas trepon\u00e9micas y las no trepon\u00e9micas con la FTA-ABS, la concordancia oscil\u00f3 entre el 44,2 y el 61,9 %. Los \u00edndices de desempe\u00f1o evidenciaron que las pruebas no trepon\u00e9micas y las trepon\u00e9micas tienen valores de sensibilidad entre el 89,70 y el 99,39 %. El valor predictivo positivo fue m\u00e1s elevado en las pruebas trepon\u00e9micas (CLIA = 95,27 %) y la tasa m\u00e1s alta de falsos positivos fue del 94,52 % en la prueba VDRL.Conclusiones. Las muestras analizadas fueron reactivas desde el inicio, lo que podr\u00eda interferir en los par\u00e1metros de medici\u00f3n. Sin embargo, aportaron informaci\u00f3n valiosa para evaluar los algoritmos implementados.<\/jats:p>","DOI":"10.7705\/biomedica.7453","type":"journal-article","created":{"date-parts":[[2025,9,25]],"date-time":"2025-09-25T21:45:14Z","timestamp":1758836714000},"page":"558-565","update-policy":"https:\/\/doi.org\/10.7705\/crossmark","source":"Crossref","is-referenced-by-count":2,"title":["Comparaci\u00f3n entre pruebas trepon\u00e9micas y no trepon\u00e9micas para la detecci\u00f3n de s\u00edfilis","Comparison between treponemal and non-treponemal tests for syphilis detection"],"prefix":"10.7705","volume":"45","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4418-4270","authenticated-orcid":false,"given":"Ver\u00f3nica","family":"Aguaiza","sequence":"first","affiliation":[{"name":"Centro de Investigaci\u00f3n para la Salud en Am\u00e9rica Latina (CISeAL), Pontificia Universidad Cat\u00f3lica del Ecuador, Quito, Ecuador"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0987-7859","authenticated-orcid":false,"given":"Rosa F.","family":"Chiriboga-Ponce","sequence":"additional","affiliation":[{"name":"Centro de Investigaci\u00f3n para la Salud en Am\u00e9rica Latina (CISeAL), Pontificia Universidad Cat\u00f3lica del Ecuador, Quito, Ecuador; Carrera de Laboratorio Cl\u00ednico, Pontificia Universidad Cat\u00f3lica del Ecuador, Quito, Ecuador"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"4444","published-online":{"date-parts":[[2025,9,22]]},"reference":[{"key":"153504","doi-asserted-by":"crossref","unstructured":"Sangthang S, Raturi M, Kandsamy D, Chenna D, Mohan G, Shastry S. Reverse algorithm for screening of syphilis and trends in prevalence among blood donors in Coastal Karnataka. Transfus Clin Biol. 2022;29:219-23. https:\/\/doi.org\/10.1016\/j.tracli.2022.04.003","DOI":"10.1016\/j.tracli.2022.04.003"},{"key":"153505","doi-asserted-by":"crossref","unstructured":"Attie A de Almeida-Neto C, Witkin S, Derriga J, Nishiya AS, Ferreira JE, Costa NSX, et al. Detection and analysis of blood donors seropositive for syphilis. Transfus Med. 2021;31:121-8. https:\/\/doi.org\/10.1111\/tme.12761","DOI":"10.1111\/tme.12761"},{"key":"153506","doi-asserted-by":"crossref","unstructured":"Ortiz DA, Shukla MR, Loeffelholz MJ. The traditional or reverse algorithm for diagnosis of syphilis: Pros and cons. Clin Infect Dis. 2020;71(Suppl. 1):S43-51. https:\/\/doi.org\/10.1093\/cid\/ciaa307","DOI":"10.1093\/cid\/ciaa307"},{"key":"153507","doi-asserted-by":"crossref","unstructured":"Luo Y, Xie Y, Xiao Y. Laboratory diagnostic tools for syphilis: Current status and future prospects. Front Cell Infect Microbiol. 2021;10:574806. https:\/\/doi.org\/10.3389\/fcimb.2020.574806","DOI":"10.3389\/fcimb.2020.574806"},{"key":"153508","doi-asserted-by":"crossref","unstructured":"Tong ML, Lin LR, Liu LL, Zhang HL, Huang SJ, Chen YY, et al. Analysis of 3 algorithms for syphilis serodiagnosis and implications for clinical management. Clin Infect Dis. 2014;58:1116-24. https:\/\/doi.org\/10.1093\/cid\/ciu087","DOI":"10.1093\/cid\/ciu087"},{"key":"153509","doi-asserted-by":"crossref","unstructured":"Park IU, Tran A, Pereira L, Fakile Y. Sensitivity and specificity of treponemal-specific tests for the diagnosis of syphilis. Clin Infect Dis. 2020;71(Suppl. 1):S13-20. https:\/\/doi.org\/10.1093\/cid\/ciaa349","DOI":"10.1093\/cid\/ciaa349"},{"key":"153510","doi-asserted-by":"crossref","unstructured":"Gu WM, Yang Y, Wang QZ, Pan BS, Guo W, Wu L, et al. Comparing the performance of traditional non-treponemal tests on syphilis and non-syphilis serum samples. Int J STD AIDS. 2013;24:919-25. https:\/\/doi.org\/10.1177\/0956462413491399","DOI":"10.1177\/0956462413491399"},{"key":"153511","unstructured":"Centers for Disease Control and Prevention (CDC). Discordant results from reverse sequence syphilis screening\u2014five laboratories, United States, 2006-2010. MMWR Morb Mortal Wkly Rep. 2011;60:133-7."},{"key":"153512","doi-asserted-by":"crossref","unstructured":"Nayak S, Acharjya B. VDRL test and its interpretation. Indian J Dermatol. 2012;57:3-8. https:\/\/doi.org\/10.4103\/0019-5154.92666","DOI":"10.4103\/0019-5154.92666"},{"key":"153513","doi-asserted-by":"crossref","unstructured":"Li L, Cai B, Tao C, Wang L. Performance evaluation of CLIA for Treponema pallidum specific antibodies detection in comparison with ELISA. J Clin Lab Anal. 2016;30:216-22. https:\/\/doi.org\/10.1002\/jcla.21839","DOI":"10.1002\/jcla.21839"},{"key":"153514","doi-asserted-by":"crossref","unstructured":"Jaramillo S, Higuita LN, Castro JJ, Barco GE, Donado JH. Sensibilidad de las pruebas trepon\u00e9micas en donantes de sangre del Hospital Pablo Tob\u00f3n Uribe 2012-2014. Med UPB. 2018;37:125-30. https:\/\/doi.org\/10.18566\/medupb.v37n2.a06","DOI":"10.18566\/medupb.v37n2.a06"},{"key":"153515","doi-asserted-by":"crossref","unstructured":"Peng J, Lu Y, Yu H, Wu S, Li T, Li H, et al. Analysis of 2 reverse syphilis testing algorithms in diagnosis of syphilis: A large-cohort prospective study. Clin Infect Dis. 2018;67:947-953. https:\/\/doi.org\/10.1093\/cid\/ciy198","DOI":"10.1093\/cid\/ciy198"},{"key":"153516","doi-asserted-by":"crossref","unstructured":"Silva \u00c2A, de Oliveira UD, Vasconcelos LC, Foti L, Leony LM, Daltro RT, et al. Performance of Treponema pallidum recombinant proteins in the serological diagnosis of syphilis. PLoS ONE. 2020;15:e0234043. https:\/\/doi.org\/10.1371\/journal.pone.0234043. Erratum in: PLoS ONE. 2020;15:e0242386","DOI":"10.1371\/journal.pone.0242386"},{"key":"153517","doi-asserted-by":"crossref","unstructured":"Serhir B, Labb\u00e9 AC, Doualla-Bell F, Simard M, Lambert G, Trudelle A, et al. Improvement of reverse sequence algorithm for syphilis diagnosis using optimal treponemal screening assay signal-to-cutoff ratio. PLoS ONE. 2018;13:e0204001. https:\/\/doi.org\/10.1371\/journal.pone.0204001","DOI":"10.1371\/journal.pone.0204001"},{"key":"153518","doi-asserted-by":"crossref","unstructured":"Sonmez C, Sezen F, Kilic S. Performance evaluation of nine different syphilis serological tests in comparison with the FTA-abs test. J Immunol Methods. 2019;464:9-14. https:\/\/doi.org\/10.1016\/j.jim.2018.08.007","DOI":"10.1016\/j.jim.2018.08.007"},{"key":"153519","doi-asserted-by":"crossref","unstructured":"Binnicker MJ. Which algorithm should be used to screen for syphilis? Curr Opin Infect Dis. 2012;25:79-85. https:\/\/doi.org\/10.1097\/QCO.0b013e32834e9a3c","DOI":"10.1097\/QCO.0b013e32834e9a3c"},{"key":"153520","doi-asserted-by":"crossref","unstructured":"Sangthang S, Raturi M, Kandsamy D, Chenna D, Mohan G, Shastry S. Reverse algorithm for screening of syphilis and trends in prevalence among blood donors in Coastal Karnataka. Transfus Clin Biol. 2022;29:219-23. https:\/\/doi.org\/10.1016\/j.tracli.2022.04.003","DOI":"10.1016\/j.tracli.2022.04.003"}],"container-title":["Biom\u00e9dica"],"original-title":[],"link":[{"URL":"https:\/\/revistabiomedica.org\/index.php\/biomedica\/article\/download\/7453\/5758","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/revistabiomedica.org\/index.php\/biomedica\/article\/download\/7453\/5881","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/revistabiomedica.org\/index.php\/biomedica\/article\/download\/7453\/5758","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,11]],"date-time":"2026-03-11T21:36:45Z","timestamp":1773265005000},"score":1,"resource":{"primary":{"URL":"https:\/\/revistabiomedica.org\/index.php\/biomedica\/article\/view\/7453"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,9,22]]},"references-count":17,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2025,9,22]]}},"URL":"https:\/\/doi.org\/10.7705\/biomedica.7453","relation":{},"ISSN":["2590-7379","0120-4157"],"issn-type":[{"value":"2590-7379","type":"electronic"},{"value":"0120-4157","type":"print"}],"subject":[],"published":{"date-parts":[[2025,9,22]]},"assertion":[{"value":"2025-09-22","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}},{"value":"Yes","order":0,"name":"peer_reviewed","label":"Peer Reviewed","group":{"name":"peer_review","label":"Peer Review"}},{"value":"Instituto Nacional de Salud","name":"publisher","label":"This article is maintained by"},{"value":"Biomedica","name":"journaltitle","label":"Journal Title"},{"value":"Art\u00edculos originales","name":"content_type","label":"Content Type"}]}}