{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,10]],"date-time":"2026-09-10T17:40:42Z","timestamp":1789062042954,"version":"build-2803163510"},"reference-count":48,"publisher":"PeerJ","license":[{"start":{"date-parts":[[2026,7,9]],"date-time":"2026-07-09T00:00:00Z","timestamp":1783555200000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Universiti Teknologi Malaysia with the reference, UTMPR grant, vote 00L45"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"abstract":"<jats:p>Our research aimed to develop and validate a predictive analytics model for diagnosing sick building syndrome (SBS) in learners. We achieved this by gathering and analyzing epidemiological and exposure assessment data. The current assessment involved the use of the modified MM040NA SBS questionnaire and checklist from Indoor Air Quality (IAQ) Industry Code of Practice (IAQ-ICOP) from Department Occupational Safety and Health (DOSH), Malaysia, with participants scoring of their answers, recording and scoring of their simultaneous self-reported and physician-ascertained health complaints. At the same time, IAQ assessments were collected at the location of each participant with the use of occupational hygiene techniques. Several predictive analytics algorithms, namely Neural Network, Logistic Regression, Classification Tree, Random Forest, and Support Vector Machine, were used to train and test the collected data set. The Neural Network model rendered the most effective classification accuracy, reaching 73.8%. Validation also showed that multiple IAQ parameters were strongly associated with health complaints, especially in mechanically ventilated environments. Variable importance analysis identified Formaldehyde and Total Volatile Organic Compounds (TVOCs) as the top predictors for health complaints, highlighting their critical role in indoor environmental quality. Taken together, the results confirm the effectiveness of neural network-based predictive analytics in correctly diagnosing sick building syndrome (SBS) and related health complaints on limited IAQ data and thereby improving the ability to assess during the early stages.<\/jats:p>","DOI":"10.7717\/peerj.20964","type":"journal-article","created":{"date-parts":[[2026,7,9]],"date-time":"2026-07-09T08:07:51Z","timestamp":1783584471000},"page":"e20964","source":"Crossref","is-referenced-by-count":2,"title":["Application of machine learning algorithms in building health diagnostics: predictive analytics evaluating indoor air quality and sick building syndrome in educational settings"],"prefix":"10.7717","volume":"14","author":[{"given":"Syazwan Aizat","family":"Ismail","sequence":"first","affiliation":[{"name":"National Poison Centre, Universiti Sains Malaysia, Gelugor, Pulau Pinang, Malaysia"},{"name":"Faculty of Mechanical Engineering, Universiti Teknologi Malaysia, Skudai, Johor Bahru, Malaysia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Haslinda Mohamed","family":"Kamar","sequence":"additional","affiliation":[{"name":"Faculty of Mechanical Engineering, Universiti Teknologi Malaysia, Skudai, Johor Bahru, Malaysia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nazri","family":"Kamsah","sequence":"additional","affiliation":[{"name":"Faculty of Mechanical Engineering, Universiti Teknologi Malaysia, Skudai, Johor Bahru, Malaysia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kuang Hock","family":"Lim","sequence":"additional","affiliation":[{"name":"National Institutes of Health (NIH), Ministry of Health Malaysia, Setia Alam, Selangor, Malaysia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nur Azzalia","family":"Kamaruzaman","sequence":"additional","affiliation":[{"name":"National Poison Centre, Universiti Sains Malaysia, Gelugor, Pulau Pinang, Malaysia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Muhammad Iftishah","family":"Ramdan","sequence":"additional","affiliation":[{"name":"School of Mechanical Engineering, Universiti Sains Malaysia, Nibong Tebal, Pulau Pinang, Malaysia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bj\u00f6rn","family":"Cr\u00fcts","sequence":"additional","affiliation":[{"name":"Neuro.online, Heerlen, Limburg, Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Muaz Mohd","family":"Zaini Makhtar","sequence":"additional","affiliation":[{"name":"Institute of Nano Optoelectronics Research and Technology, Universiti Sains Malaysia, Gelugor, Pulau Pinang, Malaysia"},{"name":"School of Industrial Technology, Universiti Sains Malaysia, Gelugor, Pulau Pinang, Malaysia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohd","family":"Rafatullah","sequence":"additional","affiliation":[{"name":"University Centre for Research and Development, Chandigarh University, Mohali, Punjab, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aseem","family":"Vashisht","sequence":"additional","affiliation":[{"name":"University Centre for Research and Development, Chandigarh University, Mohali, Punjab, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"4443","published-online":{"date-parts":[[2026,7,9]]},"reference":[{"key":"10.7717\/peerj.20964\/ref-1","doi-asserted-by":"publisher","first-page":"163","DOI":"10.11113\/jt.v76.3995","article-title":"Assessment of indoor air quality level and sick building syndrome according to the ages of building in Universiti Teknologi Malaysia","volume":"76","author":"Ahmad","year":"2015","journal-title":"Jurnal Teknologi"},{"key":"10.7717\/peerj.20964\/ref-2","doi-asserted-by":"publisher","first-page":"2476","DOI":"10.3390\/s17112476","article-title":"Indoor air quality analysis using deep learning with sensor data","volume":"17","author":"Ahn","year":"2017","journal-title":"Sensors"},{"key":"10.7717\/peerj.20964\/ref-3","first-page":"1415","article-title":"Spatial air quality modelling using chemometrics techniques: a case study in peninsular Malaysia","volume":"19","author":"Azid","year":"2015","journal-title":"Malaysian Journal of Analytical Science"},{"issue":"10","key":"10.7717\/peerj.20964\/ref-4","doi-asserted-by":"publisher","first-page":"557","DOI":"10.3390\/toxics10100557","article-title":"Deep learning-based indoor air quality forecasting framework for indoor subway station platforms","volume":"10","author":"Bakht","year":"2022","journal-title":"Toxics"},{"key":"10.7717\/peerj.20964\/ref-5","doi-asserted-by":"publisher","first-page":"193","DOI":"10.1007\/s40012-016-0121-0","article-title":"Prediction of heart disease using data mining techniques","volume":"4","author":"Chadha","year":"2016","journal-title":"CSIT"},{"key":"10.7717\/peerj.20964\/ref-6","doi-asserted-by":"publisher","first-page":"15233","DOI":"10.3390\/ijerph121214975","article-title":"Prediction of indoor air exposure from outdoor air quality using an artificial neural network model for inner city commercial buildings","volume":"12","author":"Challoner","year":"2015","journal-title":"International Journal of Environmental Research and Public Health"},{"key":"10.7717\/peerj.20964\/ref-7","doi-asserted-by":"publisher","first-page":"2218","DOI":"10.3390\/app11052218","article-title":"Data mining techniques for early diagnosis of diabetes: a comparative study","volume":"11","author":"Chaves","year":"2021","journal-title":"Applied Sciences"},{"key":"10.7717\/peerj.20964\/ref-8","first-page":"2349","article-title":"Orange: data mining toolbox in Python","volume":"14","author":"Dem\u0161ar","year":"2013","journal-title":"Journal of Machine Learning Research"},{"key":"10.7717\/peerj.20964\/ref-9","first-page":"1","volume-title":"Industry code of practice on indoor air quality 2010","author":"Department\u00a0of Occupational Safety and Health","year":"2010"},{"key":"10.7717\/peerj.20964\/ref-10","first-page":"66","article-title":"Control of a single link robot arm actuated by pneumatic artificial muscles employing active force control and fuzzy logic via hardware-in-the-loop-simulation","volume":"36","author":"Enzevaee","year":"2018","journal-title":"Jurnal Mekanikal"},{"key":"10.7717\/peerj.20964\/ref-11","doi-asserted-by":"publisher","first-page":"108710","DOI":"10.1016\/j.buildenv.2021.108710","article-title":"Research on risk scorecard of sick building syndrome based on machine learning","volume":"211","author":"Fan","year":"2022","journal-title":"Building and Environment"},{"key":"10.7717\/peerj.20964\/ref-12","doi-asserted-by":"publisher","first-page":"4401","DOI":"10.3390\/s21134401","article-title":"BIM and data-driven predictive analysis of optimum thermal comfort for indoor environment","volume":"21","author":"Gan","year":"2021","journal-title":"Sensors"},{"issue":"7","key":"10.7717\/peerj.20964\/ref-13","doi-asserted-by":"publisher","first-page":"2173","DOI":"10.3390\/s25072173","article-title":"A comparative study of CO2 forecasting strategies in school classrooms: a step toward improving indoor air quality","volume":"25","author":"Garcia-Pinilla","year":"2025","journal-title":"Sensors"},{"issue":"4","key":"10.7717\/peerj.20964\/ref-14","first-page":"339","article-title":"Quantifying digital competency gains for environmental health: a paired pre-post evaluation of applied data analytics training","volume":"15","author":"Ismail","year":"2025","journal-title":"Scope"},{"key":"10.7717\/peerj.20964\/ref-15","first-page":"235","article-title":"Indoor air quality issues for non-industrial workplace","volume":"5","author":"Ismail","year":"2010","journal-title":"International Journal of Research and Reviews in Applied Sciences"},{"issue":"2","key":"10.7717\/peerj.20964\/ref-16","first-page":"503","article-title":"Indoor air quality level influence sick building syndrome among occupants in educational buildings","volume":"11","author":"Ismail","year":"2022","journal-title":"International Journal of Public Health"},{"issue":"15s","key":"10.7717\/peerj.20964\/ref-17","first-page":"279","article-title":"From indoor environmental exposure to vascular health risk prediction: an interpretable machine learning framework for identifying acute cognitive and microvascular stress responses","volume":"8","author":"Ismail","year":"2025","journal-title":"Vascular and Endovascular Review"},{"issue":"11s","key":"10.7717\/peerj.20964\/ref-18","first-page":"313","article-title":"Dynamic network disruption under cognitive strain: coupling of local node failure and global edge integrity reveals differential systemic resilience","volume":"8","author":"Ismail","year":"2025","journal-title":"Vascular and Endovascular Review"},{"key":"10.7717\/peerj.20964\/ref-19","doi-asserted-by":"publisher","first-page":"729","DOI":"10.1007\/s13762-018-1642-x","article-title":"Modeling indoor air carbon dioxide concentration using artificial neural network","volume":"16","author":"Khazaei","year":"2019","journal-title":"International Journal of Environmental Science and Technology"},{"key":"10.7717\/peerj.20964\/ref-20","doi-asserted-by":"publisher","first-page":"96","DOI":"10.1016\/j.buildenv.2017.12.011","article-title":"Personal comfort models: predicting individuals\u2019 thermal preference using occupant heating and cooling behavior and machine learning","volume":"129","author":"Kim","year":"2018","journal-title":"Building and Environment"},{"key":"10.7717\/peerj.20964\/ref-21","doi-asserted-by":"publisher","first-page":"8","DOI":"10.1016\/j.csbj.2014.11.005","article-title":"Machine learning applications in cancer prognosis and prediction","volume":"13","author":"Kourou","year":"2015","journal-title":"Computational and Structural Biotechnology Journal"},{"issue":"19","key":"10.7717\/peerj.20964\/ref-22","doi-asserted-by":"publisher","first-page":"5194","DOI":"10.3390\/en18195194","article-title":"Artificial intelligence and machine learning approaches for indoor air quality prediction: a comprehensive review of methods and applications","volume":"18","author":"Lato\u0144","year":"2025","journal-title":"Energies"},{"key":"10.7717\/peerj.20964\/ref-23","doi-asserted-by":"publisher","first-page":"106296","DOI":"10.1016\/j.buildenv.2019.106296","article-title":"A comprehensive evaluation method for indoor air quality of buildings based on rough sets and a wavelet neural network","volume":"162","author":"Lei","year":"2019","journal-title":"Building and Environment"},{"key":"10.7717\/peerj.20964\/ref-24","doi-asserted-by":"publisher","first-page":"290","DOI":"10.1016\/j.apenergy.2011.09.037","article-title":"Dynamic modeling and control of a direct expansion air conditioning system using artificial neural network","volume":"91","author":"Li","year":"2012","journal-title":"Applied Energy"},{"key":"10.7717\/peerj.20964\/ref-25","doi-asserted-by":"publisher","first-page":"3510","DOI":"10.1007\/s11356-017-0708-5","article-title":"Exploring the potential relationship between indoor air quality and the concentration of airborne culturable fungi: a combined experimental and neural network modeling study","volume":"25","author":"Liu","year":"2018","journal-title":"Environmental Science and Pollution Research"},{"key":"10.7717\/peerj.20964\/ref-26","doi-asserted-by":"publisher","first-page":"e15298","DOI":"10.7717\/peerj.15298","article-title":"Indoor air quality in a training centre used for sports practice","volume":"11","author":"Mazoteras-Pardo","year":"2023","journal-title":"PeerJ"},{"key":"10.7717\/peerj.20964\/ref-27","doi-asserted-by":"publisher","first-page":"205","DOI":"10.1016\/S1364-8152(02)00094-4","article-title":"An enhanced cluster analysis program with bootstrap significance testing for ecological community analysis","volume":"18","author":"McKenna","year":"2003","journal-title":"Environmental Modelling & Software"},{"key":"10.7717\/peerj.20964\/ref-28","doi-asserted-by":"publisher","first-page":"1785","DOI":"10.1016\/S0140-6736(03)14897-0","article-title":"Effect of ultraviolet germicidal lights installed in office ventilation systems on workers\u2019 health and wellbeing: double-blind multiple crossover trial","volume":"362","author":"Menzies","year":"2003","journal-title":"Lancet"},{"key":"10.7717\/peerj.20964\/ref-29","doi-asserted-by":"publisher","first-page":"431","DOI":"10.1002\/widm.24","article-title":"Data mining tools","volume":"1","author":"Mikut","year":"2011","journal-title":"Wiley Interdisciplinary Reviews: Data Mining and Knowledge Discovery"},{"key":"10.7717\/peerj.20964\/ref-30","doi-asserted-by":"publisher","first-page":"184","DOI":"10.3390\/electronics10020184","article-title":"Internet of Things (IoT) based indoor air quality sensing and predictive analytic\u2014a COVID-19 perspective","volume":"10","author":"Mumtaz","year":"2021","journal-title":"Electronics"},{"key":"10.7717\/peerj.20964\/ref-31","doi-asserted-by":"publisher","first-page":"9","DOI":"10.11113\/jt.v72.4004","article-title":"An artificial neural network approach for prediction of bearing capacity of spread foundations in sand","volume":"72","author":"Nazir","year":"2015","journal-title":"Jurnal Teknologi"},{"key":"10.7717\/peerj.20964\/ref-32","doi-asserted-by":"publisher","first-page":"e1306","DOI":"10.7717\/peerj-cs.1306","article-title":"Artificial intelligence-assisted air quality monitoring for smart city management","volume":"9","author":"Neo","year":"2023","journal-title":"PeerJ Computer Science"},{"key":"10.7717\/peerj.20964\/ref-33","doi-asserted-by":"publisher","first-page":"148","DOI":"10.1016\/j.scitotenv.2016.10.148","article-title":"Respiratory symptoms and fractional exhaled nitric oxide (FeNO) among students in Penang","volume":"577","author":"Norb\u00e4ck","year":"2017","journal-title":"Science of the Total Environment"},{"key":"10.7717\/peerj.20964\/ref-34","first-page":"15","article-title":"A predictive model on throughput performance of Malaysian ports post kra canal","volume":"42","author":"Nur\u00a0Zakri","year":"2019","journal-title":"Jurnal Mekanikal"},{"key":"10.7717\/peerj.20964\/ref-35","article-title":"Orange data mining library documentation release 3.10","author":"Orange Data\u00a0Mining","year":"2013"},{"key":"10.7717\/peerj.20964\/ref-36","doi-asserted-by":"publisher","first-page":"425","DOI":"10.1111\/j.1600-0668.2004.00291.x","article-title":"Building-related respiratory symptoms can be predicted with semi-quantitative indices of exposure to dampness and mold","volume":"14","author":"Park","year":"2004","journal-title":"Indoor Air"},{"key":"10.7717\/peerj.20964\/ref-37","doi-asserted-by":"publisher","first-page":"11665","DOI":"10.3390\/s150511665","article-title":"Classifying sources influencing indoor air quality (IAQ) using artificial neural network (ANN)","volume":"15","author":"Saad","year":"2015","journal-title":"Sensors"},{"issue":"14","key":"10.7717\/peerj.20964\/ref-38","doi-asserted-by":"publisher","first-page":"4942","DOI":"10.3390\/ijerph17144942","article-title":"Indoor air quality monitoring systems based on Internet of Things: a systematic review","volume":"17","author":"Saini","year":"2020","journal-title":"International Journal of Environmental Research and Public Health"},{"key":"10.7717\/peerj.20964\/ref-39","first-page":"38","article-title":"Predictive and reliability based collision risk aversion model for inland waterways: the case frequency estimation for Malaysian langat river","volume":"32","author":"Sulaiman","year":"2011","journal-title":"Jurnal Mekanikal"},{"key":"10.7717\/peerj.20964\/ref-40","doi-asserted-by":"publisher","first-page":"87","DOI":"10.2147\/tcrm.s39136","article-title":"Gender, airborne chemical monitoring, and physical work environment are related to indoor air symptoms among nonindustrial workers in the Klang Valley, Malaysia","volume":"9","author":"Syazwan","year":"2013","journal-title":"Therapeutics and Clinical Risk Management"},{"key":"10.7717\/peerj.20964\/ref-41","doi-asserted-by":"publisher","first-page":"107","DOI":"10.2147\/dhps.s33400","article-title":"Analysis of indoor air pollutants checklist using environmetric technique for health risk assessment of sick building complaint in nonindustrial workplace","volume":"4","author":"Syazwan","year":"2012","journal-title":"Drug, Healthcare and Patient Safety"},{"key":"10.7717\/peerj.20964\/ref-42","doi-asserted-by":"publisher","first-page":"17","DOI":"10.2147\/rmhp.s26567","article-title":"Development of an indoor air quality checklist for risk assessment of indoor air pollutants by semiquantitative score in nonindustrial workplaces","volume":"5","author":"Syazwan","year":"2012","journal-title":"Risk Management Healthcare Policy"},{"key":"10.7717\/peerj.20964\/ref-43","doi-asserted-by":"publisher","first-page":"61","DOI":"10.1016\/j.scitotenv.2011.12.060","article-title":"A longitudinal study of aldehydes and volatile organic compounds associated with subjective symptoms related to sick building syndrome in new dwellings in Japan","volume":"417\u2013418","author":"Takigawa","year":"2012","journal-title":"The Science of the Total Environment"},{"key":"10.7717\/peerj.20964\/ref-44","doi-asserted-by":"publisher","first-page":"1137","DOI":"10.1007\/s12553-020-00438-1","article-title":"Heart disease classification using data mining tools and machine learning techniques","volume":"10","author":"Tougui","year":"2020","journal-title":"Health Technology"},{"key":"10.7717\/peerj.20964\/ref-45","doi-asserted-by":"publisher","first-page":"2927","DOI":"10.3390\/ijerph17082927","article-title":"Indoor air pollution, related human diseases, and recent trends in the control and improvement of indoor air quality","volume":"17","author":"Tran","year":"2020","journal-title":"International Journal of Environmental Research and Public Health"},{"key":"10.7717\/peerj.20964\/ref-46","doi-asserted-by":"publisher","first-page":"414","DOI":"10.1109\/ICNC.2009.502","article-title":"Prediction of indoor air quality using artificial neural networks","author":"Xie","year":"2009"},{"key":"10.7717\/peerj.20964\/ref-47","doi-asserted-by":"publisher","first-page":"1140","DOI":"10.3844\/ajassp.2013.1140.1147","article-title":"Indoor air quality and prevalence of sick building syndrome among office workers in two different offices in Selangor","volume":"10","author":"Zamani","year":"2013","journal-title":"American Journal of Applied Sciences"},{"key":"10.7717\/peerj.20964\/ref-48","doi-asserted-by":"publisher","first-page":"e112933","DOI":"10.1371\/journal.pone.0112933","article-title":"A longitudinal study of sick building syndrome (SBS) among pupils in relation to SO2, NO2, O3 and PM10 in Schools in China","volume":"9","author":"Zhang","year":"2014","journal-title":"PLOS ONE"}],"container-title":["PeerJ"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/peerj.com\/articles\/20964.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/peerj.com\/articles\/20964.xml","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/peerj.com\/articles\/20964.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/peerj.com\/articles\/20964.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,9]],"date-time":"2026-07-09T08:07:55Z","timestamp":1783584475000},"score":1,"resource":{"primary":{"URL":"https:\/\/peerj.com\/articles\/20964"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,9]]},"references-count":48,"alternative-id":["10.7717\/peerj.20964"],"URL":"https:\/\/doi.org\/10.7717\/peerj.20964","archive":["CLOCKSS","LOCKSS","Portico"],"relation":{},"ISSN":["2167-8359"],"issn-type":[{"value":"2167-8359","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,9]]},"article-number":"e20964"}}