{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,24]],"date-time":"2026-03-24T05:07:57Z","timestamp":1774328877829,"version":"3.50.1"},"reference-count":17,"publisher":"PeerJ","license":[{"start":{"date-parts":[[2018,6,18]],"date-time":"2018-06-18T00:00:00Z","timestamp":1529280000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"National Council for Scientific and Technological Development of Brazil"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"abstract":"<jats:p>The results of a computer simulation examining the compliance of a given transcranial magnetic stimulation device to the 2010 International Commission on Non-Ionizing Radiation Protection (ICNIRP) guidelines are presented. The objective was to update the safe distance estimates with the most current safety guidelines, as well as comparing these to values reported in previous publications. The 3D data generated was compared against results available in the literature, regarding the MCB-70 coil by Medtronic. Regarding occupational exposure, safe distances of 1.46 m and 0.96 m are derived from the simulation according to the 2003 and 2010 ICNIRP guidelines, respectively. These values are then compared to safe distances previously reported in other studies.<\/jats:p>","DOI":"10.7717\/peerj.5034","type":"journal-article","created":{"date-parts":[[2018,6,18]],"date-time":"2018-06-18T07:48:52Z","timestamp":1529308132000},"page":"e5034","source":"Crossref","is-referenced-by-count":7,"title":["Safe exposure distances for transcranial magnetic stimulation based on computer simulations"],"prefix":"10.7717","volume":"6","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7536-0081","authenticated-orcid":true,"given":"Iam","family":"Palatnik de Sousa","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Carlos R. H.","family":"Barbosa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Elisabeth","family":"Costa Monteiro","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"4443","published-online":{"date-parts":[[2018,6,18]]},"reference":[{"key":"10.7717\/peerj.5034\/ref-1","author":"Conselho Federal de Medicina","year":"2012","unstructured":"Resolu\u00e7\u00e3o CFM 1.986"},{"issue":"2","key":"10.7717\/peerj.5034\/ref-2","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1119\/1.16589","article-title":"Time-dependent generalizations of the Biot\u2013Savart and Coulomb laws","volume":"59","author":"Griffiths","year":"1991","journal-title":"American Journal of Physics"},{"issue":"2","key":"10.7717\/peerj.5034\/ref-3","doi-asserted-by":"publisher","first-page":"156","DOI":"10.1002\/bem.20194","article-title":"Therapeutic staff exposure to magnetic field pulses during TMS\/rTMS treatments","volume":"27","author":"Karlstr\u00f6m","year":"2006","journal-title":"Bioeletromagnetics"},{"issue":"9","key":"10.7717\/peerj.5034\/ref-4","doi-asserted-by":"publisher","first-page":"09B316","DOI":"10.1063\/1.3357343","article-title":"Dosimetry of typical transcranial magnetic stimulation devices","volume":"107","author":"Lu","year":"2010","journal-title":"Journal of Applied Physics"},{"issue":"6","key":"10.7717\/peerj.5034\/ref-5","doi-asserted-by":"publisher","first-page":"640","DOI":"10.1097\/yco.0b013e3283136a0c","article-title":"Transcranial magnetic stimulation","volume":"21","author":"L\u00f3pez-Ibor","year":"2008","journal-title":"Current Opinion in Psychiatry"},{"key":"10.7717\/peerj.5034\/ref-6","first-page":"6","article-title":"\u201cBiometrology: reliability of biomeasurements and ethical implications,\u201d \u201cBiometrologia: confiabilidade nas biomedi\u00e7\u00f5es e repercuss\u00f5es \u00e9ticas\u201d","volume":"6","author":"Monteiro","year":"2007","journal-title":"Metrologia e Instrumenta\u00e7\u00e3o"},{"key":"10.7717\/peerj.5034\/ref-7","doi-asserted-by":"publisher","first-page":"012032","DOI":"10.1088\/1742-6596\/588\/1\/012032","article-title":"Metrological reliability of medical devices","volume":"588","author":"Monteiro","year":"2015","journal-title":"Journal of Physics"},{"issue":"7","key":"10.7717\/peerj.5034\/ref-8","doi-asserted-by":"publisher","first-page":"900","DOI":"10.1109\/tbme.2003.813548","article-title":"Computation of electric and magnetic stimulation in human head using the 3-D impedance method","volume":"50","author":"Nadeem","year":"2003","journal-title":"IEEE Transactions on Biomedical Engineering"},{"key":"10.7717\/peerj.5034\/ref-9","first-page":"1325","article-title":"Transcranial magnetic stimulation: Terminology and safety aspects concerning therapeutic protocol and device reliability","author":"Palatnik-de-Sousa","year":"2014","journal-title":"XXIV Congresso Brasileiro de Engenharia Biom\u00e9dica"},{"key":"10.7717\/peerj.5034\/ref-10","article-title":"Transcranial magnetic stimulation conformity assessment","author":"Palatnik-de-Sousa","year":"2015","journal-title":"XXI IMEKO World Congress \u201cMeasurement in Research and Industry\u201d August 30 to September 4, 2015, Prague, Czech Republic"},{"issue":"12","key":"10.7717\/peerj.5034\/ref-11","doi-asserted-by":"crossref","first-page":"2008","DOI":"10.1016\/j.clinph.2009.08.016","article-title":"The Safety of TMS Consensus Group, Safety, ethical considerations, and application guidelines for the use of transcranial magnetic stimulation in clinical practice and research","volume":"120","author":"Rossi","year":"2009","journal-title":"Clinical Neurophisiology"},{"issue":"4","key":"10.7717\/peerj.5034\/ref-12","first-page":"494","article-title":"Guidelines for limiting exposure to time-varying electric, magnetic and electromagnetic fields (up to 300 GHz)","volume":"74","author":"The International Commission on Non-Ionizing Radiation Protection (ICNIRP)","year":"1998","journal-title":"Health Physics"},{"issue":"3","key":"10.7717\/peerj.5034\/ref-13","doi-asserted-by":"publisher","first-page":"383","DOI":"10.1097\/00004032-200303000-00016","article-title":"Guidance on determining compliance of exposure to pulsed and complex non-sinusoidal waveforms below 100 kHz with ICNIRP guidelines","volume":"84","author":"The International Commission on Non-Ionizing Radiation Protection (ICNIRP)","year":"2003","journal-title":"Health Physics"},{"issue":"6","key":"10.7717\/peerj.5034\/ref-14","doi-asserted-by":"crossref","first-page":"818","DOI":"10.1097\/HP.0b013e3181f06c86","article-title":"Guidelines for limiting exposure to time varying electric and magnetic fields (1 Hz\u2013100 kHz)","volume":"99","author":"The International Commission on Non-Ionizing Radiation Protection (ICNIRP)","year":"2010","journal-title":"Health Physics"},{"issue":"3","key":"10.7717\/peerj.5034\/ref-15","doi-asserted-by":"publisher","first-page":"418","DOI":"10.1097\/hp.0b013e31829e5580","article-title":"Guidelines for limiting exposure to electric fields induced by movement of the human body in a static magnetic field and by time-varying magnetic fields below 1 Hz","volume":"106","author":"The International Commission on Non-Ionizing Radiation Protection (ICNIRP)","year":"2014","journal-title":"Health Physics"},{"issue":"1","key":"10.7717\/peerj.5034\/ref-16","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/s0168-5597(97)00096-8","article-title":"Risk and Safety of repetitive transcranial magnetic stimulation: report and suggested guidelines from the international Workshop on the Safety of Repetitive Transcranial Magnetic Stimulation, June 5\u20137, 1996","volume":"108","author":"Wasserman","year":"1998","journal-title":"Electroencephalography and Clinical Neurophysiology\/Evoked Potentials Section"},{"key":"10.7717\/peerj.5034\/ref-17","author":"World Health Organization (WHO)","year":"2006","journal-title":"Framework for Developing Health-Based EMF Standards"}],"container-title":["PeerJ"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/peerj.com\/articles\/5034.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/peerj.com\/articles\/5034.xml","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/peerj.com\/articles\/5034.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/peerj.com\/articles\/5034.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,8,25]],"date-time":"2022-08-25T21:27:45Z","timestamp":1661462865000},"score":1,"resource":{"primary":{"URL":"https:\/\/peerj.com\/articles\/5034"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,6,18]]},"references-count":17,"alternative-id":["10.7717\/peerj.5034"],"URL":"https:\/\/doi.org\/10.7717\/peerj.5034","archive":["CLOCKSS","LOCKSS","Portico"],"relation":{},"ISSN":["2167-8359"],"issn-type":[{"value":"2167-8359","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,6,18]]},"article-number":"e5034"}}