{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,12]],"date-time":"2026-01-12T10:22:17Z","timestamp":1768213337923,"version":"3.49.0"},"reference-count":13,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,1,11]]},"DOI":"10.7759\/cureus.101318","type":"journal-article","created":{"date-parts":[[2026,1,12]],"date-time":"2026-01-12T07:15:12Z","timestamp":1768202112000},"source":"Crossref","is-referenced-by-count":0,"title":["High Negative Predictive Value but Moderate Overall Performance of Synovasure Compared With Joint Aspirate Culture in the Diagnosis of Prosthetic Joint Infection"],"prefix":"10.7759","author":[{"given":"Miles W","family":"Benjamin","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Muddasir Reyaz","family":"Hassan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Abdirahman","family":"Osman","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nikolaos","family":"Papadakos","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Aine","family":"Ringrose","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"John","family":"Stammers","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Philip","family":"Mitchell","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sulaiman","family":"Alazzawi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Suroosh","family":"Madanipour","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"ref1","unstructured":"National Joint Registry. National Joint Registry for England, Wales and Northern Ireland. 16th Annual Report. (2019). https:\/\/reports.njrcentre.org.uk\/Portals\/0\/PDFdownloads\/NJR%2016th%20Annual%20Report%202019.pdf."},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.100B1.BJJ-2017-0630.R1","article-title":"Synovasure \"quick test\" is not as accurate as the laboratory-based \u03b1-defensin immunoassay: a systematic review and meta-analysis","volume":"100-B","author":"Suen K","year":"2018","unstructured":"Suen K, Keeka M, Ailabouni R, Tran P. Synovasure \"quick test\" is not as accurate as the laboratory-based \u03b1-defensin immunoassay: a systematic review and meta-analysis. Bone Joint J. 2018, 100-B:66-72. 10.1302\/0301-620X.100B1.BJJ-2017-0630.R1","journal-title":"Bone Joint J"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.94B5.27073","article-title":"A financial analysis of revision hip arthroplasty: the economic burden in relation to the national tariff","volume":"94","author":"Vanhegan IS","year":"2012","unstructured":"Vanhegan IS, Malik AK, Jayakumar P, Ul Islam S, Haddad FS. A financial analysis of revision hip arthroplasty: the economic burden in relation to the national tariff. J Bone Joint Surg Br. 2012, 94:619-23. 10.1302\/0301-620X.94B5.27073","journal-title":"J Bone Joint Surg Br"},{"key":"ref4","article-title":"Detection of occult infection following total joint arthroplasty using sequential technetium-99m HDP bone scintigraphy and indium-111 WBC imaging","volume":"29","author":"Johnson JA","year":"1988","unstructured":"Johnson JA, Christie MJ, Sandler MP, Parks PF Jr, Homra L, Kaye JJ. Detection of occult infection following total joint arthroplasty using sequential technetium-99m HDP bone scintigraphy and indium-111 WBC imaging. J Nucl Med. 1988, 29:1347-53.","journal-title":"J Nucl Med"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1016\/j.ocl.2016.03.001","article-title":"Diagnosis of periprosthetic joint infection following hip and knee arthroplasty","volume":"47","author":"Parvizi J","year":"2016","unstructured":"Parvizi J, Fassihi SC, Enayatollahi MA. Diagnosis of periprosthetic joint infection following hip and knee arthroplasty. Orthop Clin North Am. 2016, 47:505-15. 10.1016\/j.ocl.2016.03.001","journal-title":"Orthop Clin North Am"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1128\/JCM.02497-15","article-title":"How many samples and how many culture media to diagnose a prosthetic joint infection: a clinical and microbiological prospective multicenter study","volume":"54","author":"B\u00e9mer P","year":"2016","unstructured":"B\u00e9mer P, L\u00e9ger J, Tand\u00e9 D, et al.. How many samples and how many culture media to diagnose a prosthetic joint infection: a clinical and microbiological prospective multicenter study. J Clin Microbiol. 2016, 54:385-91. 10.1128\/JCM.02497-15","journal-title":"J Clin Microbiol"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2016.05.033","article-title":"Intraoperative diagnosis of periprosthetic joint infection using a novel alpha-defensin lateral flow assay","volume":"31","author":"Kasparek MF","year":"2016","unstructured":"Kasparek MF, Kasparek M, Boettner F, Faschingbauer M, Hahne J, Dominkus M. Intraoperative diagnosis of periprosthetic joint infection using a novel alpha-defensin lateral flow assay. J Arthroplasty. 2016, 31:2871-4. 10.1016\/j.arth.2016.05.033","journal-title":"J Arthroplasty"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.90B7.20417","article-title":"The value of synovial biopsy, joint aspiration and C-reactive protein in the diagnosis of late peri-prosthetic infection of total knee replacements","volume":"90","author":"Fink B","year":"2008","unstructured":"Fink B, Makowiak C, Fuerst M, Berger I, Sch\u00e4fer P, Frommelt L. The value of synovial biopsy, joint aspiration and C-reactive protein in the diagnosis of late peri-prosthetic infection of total knee replacements. J Bone Joint Surg Br. 2008, 90:874-8. 10.1302\/0301-620X.90B7.20417","journal-title":"J Bone Joint Surg Br"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.5312\/wjo.v11.i1.36","article-title":"Good accuracy of the alpha-defensin lateral flow test for hip periprosthetic joint infection: a pilot study in a retrospective cohort of 52 patients","volume":"11","author":"Kuiper JW","year":"2020","unstructured":"Kuiper JW, Pander P, Vos SJ. Good accuracy of the alpha-defensin lateral flow test for hip periprosthetic joint infection: a pilot study in a retrospective cohort of 52 patients. World J Orthop. 2020, 11:36-46. 10.5312\/wjo.v11.i1.36","journal-title":"World J Orthop"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1177\/2309499019828459","article-title":"Accuracy of the \u03b1-defensin lateral flow assay for diagnosing periprosthetic joint infection in Asians","volume":"27","author":"Ding BT","year":"2019","unstructured":"Ding BT, Tan KG, Kau CY, Chan HY, Mohd Fadil MF. Accuracy of the \u03b1-defensin lateral flow assay for diagnosing periprosthetic joint infection in Asians. J Orthop Surg (Hong Kong). 2019, 27:2309499019828459. 10.1177\/2309499019828459","journal-title":"J Orthop Surg (Hong Kong)"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1302\/2046-3758.95.BJR-2019-0213.R1","article-title":"Preliminary evaluation of a rapid lateral flow calprotectin test for the diagnosis of prosthetic joint infection","volume":"9","author":"Trotter AJ","year":"2020","unstructured":"Trotter AJ, Dean R, Whitehouse CE, et al.. Preliminary evaluation of a rapid lateral flow calprotectin test for the diagnosis of prosthetic joint infection. Bone Joint Res. 2020, 9:202-10. 10.1302\/2046-3758.95.BJR-2019-0213.R1","journal-title":"Bone Joint Res"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.16.01522","article-title":"The accuracy of the alpha defensin lateral flow device for diagnosis of periprosthetic joint infection: comparison with a gold standard","volume":"100","author":"Gehrke T","year":"2018","unstructured":"Gehrke T, Lausmann C, Citak M, Bonanzinga T, Frommelt L, Zahar A. The accuracy of the alpha defensin lateral flow device for diagnosis of periprosthetic joint infection: comparison with a gold standard. J Bone Joint Surg Am. 2018, 100:42-8. 10.2106\/JBJS.16.01522","journal-title":"J Bone Joint Surg Am"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1007\/s43465-025-01409-2","article-title":"The usefulness of the alpha-defensin lateral flow test in the diagnosis of prosthetic infection: a retrospective cohort study","volume":"59","author":"Galipienso-Eri M","year":"2025","unstructured":"Galipienso-Eri M, Barald\u00e9s-Canals M, Aliaga-Mart\u00ednez A, Hern\u00e1ndez A. The usefulness of the alpha-defensin lateral flow test in the diagnosis of prosthetic infection: a retrospective cohort study. Indian J Orthop. 2025, 59:1187-92. 10.1007\/s43465-025-01409-2","journal-title":"Indian J Orthop"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/439692-high-negative-predictive-value-but-moderate-overall-performance-of-synovasure-compared-with-joint-aspirate-culture-in-the-diagnosis-of-prosthetic-joint-infection","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,12]],"date-time":"2026-01-12T07:15:13Z","timestamp":1768202113000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/439692-high-negative-predictive-value-but-moderate-overall-performance-of-synovasure-compared-with-joint-aspirate-culture-in-the-diagnosis-of-prosthetic-joint-infection"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1,11]]},"references-count":13,"URL":"https:\/\/doi.org\/10.7759\/cureus.101318","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2026,1,11]]}}}