{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,24]],"date-time":"2026-01-24T03:43:57Z","timestamp":1769226237246,"version":"3.49.0"},"reference-count":16,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,1,23]]},"DOI":"10.7759\/cureus.102150","type":"journal-article","created":{"date-parts":[[2026,1,23]],"date-time":"2026-01-23T14:50:46Z","timestamp":1769179846000},"source":"Crossref","is-referenced-by-count":0,"title":["Accuracy and Clinical Safety of the FreeStyle Libre 2 System in an Internal Medicine Intermediate Care Unit"],"prefix":"10.7759","author":[{"given":"Helena","family":"Urbano Ferreira","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Patr\u00edcia","family":"Ferreira","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Catarina","family":"Faustino","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rui","family":"Ribeiro","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Joana","family":"Queir\u00f3s","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sandra","family":"Belo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fernando","family":"Fri\u00f5es","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1097\/CCE.0000000000001025","article-title":"Glycemic variability as a prognostic factor for mortality in patients with critical illness: a systematic review and meta-analysis","volume":"6","author":"Hryciw BN","year":"2024","unstructured":"Hryciw BN, Ghossein J, Rochwerg B, et al.. Glycemic variability as a prognostic factor for mortality in patients with critical illness: a systematic review and meta-analysis. Crit Care Explor. 2024, 6:e1025. 10.1097\/CCE.0000000000001025","journal-title":"Crit Care Explor"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.2337\/dc12-2430","article-title":"Increased glycemic variability is independently associated with length of stay and mortality in noncritically ill hospitalized patients","volume":"36","author":"Mendez CE","year":"2013","unstructured":"Mendez CE, Mok KT, Ata A, Tanenberg RJ, Calles-Escandon J, Umpierrez GE. Increased glycemic variability is independently associated with length of stay and mortality in noncritically ill hospitalized patients. Diabetes Care. 2013, 36:4091-7. 10.2337\/dc12-2430","journal-title":"Diabetes Care"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1530\/EC-23-0180","article-title":"Continuous glucose monitoring for inpatient diabetes management: an update on current evidence and practice","volume":"12","author":"Zelada H","year":"2023","unstructured":"Zelada H, Perez-Guzman MC, Chernavvsky DR, Galindo RJ. Continuous glucose monitoring for inpatient diabetes management: an update on current evidence and practice. Endocr Connect. 2023, 12:10.1530\/EC-23-0180","journal-title":"Endocr Connect"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.2337\/dc19-2073","article-title":"Comparison of the Freestyle Libre Pro Flash continuous glucose monitoring (CGM) system and point-of-care capillary glucose testing in hospitalized patients with type 2 diabetes treated with basal-bolus insulin regimen","volume":"43","author":"Galindo RJ","year":"2020","unstructured":"Galindo RJ, Migdal AL, Davis GM, et al.. Comparison of the Freestyle Libre Pro Flash continuous glucose monitoring (CGM) system and point-of-care capillary glucose testing in hospitalized patients with type 2 diabetes treated with basal-bolus insulin regimen. Diabetes Care. 2020, 43:2730-5. 10.2337\/dc19-2073","journal-title":"Diabetes Care"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.2337\/dc23-0089","article-title":"Real-world accuracy of CGM in inpatient critical and noncritical care settings at a safety-net hospital","volume":"46","author":"Finn E","year":"2023","unstructured":"Finn E, Schlichting L, Grau L, Douglas IS, Pereira RI. Real-world accuracy of CGM in inpatient critical and noncritical care settings at a safety-net hospital. Diabetes Care. 2023, 46:1825-30. 10.2337\/dc23-0089","journal-title":"Diabetes Care"},{"key":"ref6","doi-asserted-by":"crossref","DOI":"10.1177\/19322968221076562","article-title":"Accuracy of continuous glucose monitors for inpatient diabetes management","volume":"17","author":"Wright JJ","year":"2023","unstructured":"Wright JJ, Williams AJ, Friedman SB, et al.. Accuracy of continuous glucose monitors for inpatient diabetes management. J Diabetes Sci Technol. 2023, 17:1252-5.","journal-title":"J Diabetes Sci Technol"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.2337\/dc20-2856","article-title":"Accuracy of Dexcom G6 continuous glucose monitoring in non-critically ill hospitalized patients with diabetes","volume":"44","author":"Davis GM","year":"2021","unstructured":"Davis GM, Spanakis EK, Migdal AL, et al.. Accuracy of Dexcom G6 continuous glucose monitoring in non-critically ill hospitalized patients with diabetes. Diabetes Care. 2021, 44:1641-6. 10.2337\/dc20-2856","journal-title":"Diabetes Care"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1007\/s00125-024-06250-0","article-title":"Accuracy of continuous glucose monitoring in the hospital setting: an observational study","volume":"67","author":"O'Connor MY","year":"2024","unstructured":"O'Connor MY, Flint KL, Sabean A, et al.. Accuracy of continuous glucose monitoring in the hospital setting: an observational study. Diabetologia. 2024, 67:2650-9. 10.1007\/s00125-024-06250-0","journal-title":"Diabetologia"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1177\/19322968221110830","article-title":"Use of continuous glucose monitors by people without diabetes: an idea whose time has come?","volume":"17","author":"Klonoff DC","year":"2023","unstructured":"Klonoff DC, Nguyen KT, Xu NY, Gutierrez A, Espinoza JC, Vidmar AP. Use of continuous glucose monitors by people without diabetes: an idea whose time has come?. J Diabetes Sci Technol. 2023, 17:1686-97. 10.1177\/19322968221110830","journal-title":"J Diabetes Sci Technol"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1186\/s13019-024-03229-1","article-title":"Accuracy of Freestyle Libre continuous glucose monitoring system in critically ill patients after cardiac surgery","volume":"20","author":"Gu J","year":"2025","unstructured":"Gu J, Zhao Z, Li H, et al.. Accuracy of Freestyle Libre continuous glucose monitoring system in critically ill patients after cardiac surgery. J Cardiothorac Surg. 2025, 20:75. 10.1186\/s13019-024-03229-1","journal-title":"J Cardiothorac Surg"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.2337\/dci24-0073","article-title":"Consensus considerations and good practice points for use of continuous glucose monitoring systems in hospital settings","volume":"47","author":"Shaw JL","year":"2024","unstructured":"Shaw JL, Bannuru RR, Beach L, et al.. Consensus considerations and good practice points for use of continuous glucose monitoring systems in hospital settings. Diabetes Care. 2024, 47:2062-75. 10.2337\/dci24-0073","journal-title":"Diabetes Care"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1089\/dia.2024.0639","article-title":"Real-world performance of personal continuous glucose monitors during hospitalization","volume":"27","author":"Dumitrascu AG","year":"2025","unstructured":"Dumitrascu AG, Perry M, Chindris AM, et al.. Real-world performance of personal continuous glucose monitors during hospitalization. Diabetes Technol Ther. 2025, 27:613-22. 10.1089\/dia.2024.0639","journal-title":"Diabetes Technol Ther"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.2337\/diacare.23.8.1143","article-title":"A new consensus error grid to evaluate the clinical significance of inaccuracies in the measurement of blood glucose","volume":"23","author":"Parkes JL","year":"2000","unstructured":"Parkes JL, Slatin SL, Pardo S, Ginsberg BH. A new consensus error grid to evaluate the clinical significance of inaccuracies in the measurement of blood glucose. Diabetes Care. 2000, 23:1143-8. 10.2337\/diacare.23.8.1143","journal-title":"Diabetes Care"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1177\/1932296818812062","article-title":"Measures of accuracy for continuous glucose monitoring and blood glucose monitoring devices","volume":"13","author":"Freckmann G","year":"2019","unstructured":"Freckmann G, Pleus S, Grady M, Setford S, Levy B. Measures of accuracy for continuous glucose monitoring and blood glucose monitoring devices. J Diabetes Sci Technol. 2019, 13:575-83. 10.1177\/1932296818812062","journal-title":"J Diabetes Sci Technol"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.2337\/dci24-0020","article-title":"Real-time continuous glucose monitoring in the intensive care unit: the fifth vital sign","volume":"47","author":"Patham B","year":"2024","unstructured":"Patham B, Kansara A, Sadhu AR. Real-time continuous glucose monitoring in the intensive care unit: the fifth vital sign. Diabetes Care. 2024, 47:924-6. 10.2337\/dci24-0020","journal-title":"Diabetes Care"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.1177\/1932296820958754","article-title":"Accuracy of a 14-day factory-calibrated continuous glucose monitoring system with advanced algorithm in pediatric and adult population with diabetes","volume":"16","author":"Alva S","year":"2022","unstructured":"Alva S, Bailey T, Brazg R, et al.. Accuracy of a 14-day factory-calibrated continuous glucose monitoring system with advanced algorithm in pediatric and adult population with diabetes. J Diabetes Sci Technol. 2022, 16:70-7. 10.1177\/1932296820958754","journal-title":"J Diabetes Sci Technol"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/451646-accuracy-and-clinical-safety-of-the-freestyle-libre-2-system-in-an-internal-medicine-intermediate-care-unit","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,23]],"date-time":"2026-01-23T14:50:47Z","timestamp":1769179847000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/451646-accuracy-and-clinical-safety-of-the-freestyle-libre-2-system-in-an-internal-medicine-intermediate-care-unit"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1,23]]},"references-count":16,"URL":"https:\/\/doi.org\/10.7759\/cureus.102150","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2026,1,23]]}}}