{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,27]],"date-time":"2026-01-27T20:51:37Z","timestamp":1769547097281,"version":"3.49.0"},"reference-count":15,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,1,27]]},"DOI":"10.7759\/cureus.102362","type":"journal-article","created":{"date-parts":[[2026,1,27]],"date-time":"2026-01-27T08:01:51Z","timestamp":1769500911000},"source":"Crossref","is-referenced-by-count":0,"title":["Biomechanical Fracture Thresholds of the Tibia and Fibula Under Axial and Multi-axial Loading: A Systematic Review"],"prefix":"10.7759","author":[{"given":"Muhammad","family":"Zain Ul Abidin","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mashal","family":"Mumtaz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shashwat","family":"Shetty","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shenouda R","family":"Shehata Abdelmesih","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mohammad G. H","family":"Suliman","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Saad","family":"Abdullah","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"ref1","article-title":"Anatomy, bony pelvis and lower limb: fibula","author":"Gupton M","year":"2025","unstructured":"Gupton M, Munjal A, Kang M. Anatomy, bony pelvis and lower limb: fibula. StatPearls [Internet]. StatPearls Publishing, Treasure Island (FL); 2025."},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.12968\/hmed.2006.67.Sup6.21304","article-title":"Tibial and fibula fractures","volume":"67","author":"Young CF","year":"2006","unstructured":"Young CF, Haddad F. Tibial and fibula fractures. Br J Hosp Med (Lond). 2006, 67:M116-8. 10.12968\/hmed.2006.67.Sup6.21304","journal-title":"Br J Hosp Med (Lond)"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.21203\/rs.3.rs-467009\/v1","article-title":"Biomechanical Role of Fibula in Lower Limbs: A Fracture Mechanics Analysis (Preprint)","author":"Shao B","year":"2021","unstructured":"Shao B, Xing J, Liu D, et al.. Biomechanical Role of Fibula in Lower Limbs: A Fracture Mechanics Analysis (Preprint). Research Square, 2021. 10.21203\/rs.3.rs-467009\/v1"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1007\/s10439-017-1824-6","article-title":"The injury tolerance of the tibia under off-axis impact loading","volume":"45","author":"Chakravarty AB","year":"2017","unstructured":"Chakravarty AB, Martinez AA, Quenneville CE. The injury tolerance of the tibia under off-axis impact loading. Ann Biomed Eng. 2017, 45:1534-42. 10.1007\/s10439-017-1824-6","journal-title":"Ann Biomed Eng"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.n71","article-title":"The PRISMA 2020 statement: an updated guideline for reporting systematic reviews","volume":"372","author":"Page MJ","year":"2021","unstructured":"Page MJ, McKenzie JE, Bossuyt PM, et al.. The PRISMA 2020 statement: an updated guideline for reporting systematic reviews. BMJ. 2021, 372:n71. 10.1136\/bmj.n71","journal-title":"BMJ"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1177\/1524839919893361","article-title":"A review of the PubMed PICO tool: using evidence-based practice in health education","volume":"21","author":"Brown D","year":"2020","unstructured":"Brown D. A review of the PubMed PICO tool: using evidence-based practice in health education. Health Promot Pract. 2020, 21:496-8. 10.1177\/1524839919893361","journal-title":"Health Promot Pract"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1016\/j.jclinepi.2023.06.015","article-title":"Risk-of-bias assessment using Cochrane's revised tool for randomized trials (RoB 2) was useful but challenging and resource-intensive: observations from a systematic review","volume":"161","author":"Crocker TF","year":"2023","unstructured":"Crocker TF, Lam N, Jord\u00e3o M, et al.. Risk-of-bias assessment using Cochrane's revised tool for randomized trials (RoB 2) was useful but challenging and resource-intensive: observations from a systematic review. J Clin Epidemiol. 2023, 161:39-45. 10.1016\/j.jclinepi.2023.06.015","journal-title":"J Clin Epidemiol"},{"key":"ref8","article-title":"Biomechanical injury response of leg subjected to combined axial compressive and bending loading","volume":"44","author":"Untaroiu CD","year":"2008","unstructured":"Untaroiu CD, Ivarsson J, Genovese DR, Bose D, Crandall JR. Biomechanical injury response of leg subjected to combined axial compressive and bending loading. Biomed Sci Instrum. 2008, 44:141-6.","journal-title":"Biomed Sci Instrum"},{"key":"ref9","article-title":"Leg, foot, and ankle injury biomechanics","author":"Salzar RS","year":"2014","unstructured":"Salzar RS, Lievers WB, Bailey AM. Leg, foot, and ankle injury biomechanics. Accidental Injury: Biomechanics and Prevention. Springer, New York, NY; 2014. 499-547."},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmbbm.2017.11.013","article-title":"The effect of impact duration on the axial fracture tolerance of the isolated tibia during automotive and military impacts","volume":"78","author":"Martinez AA","year":"2018","unstructured":"Martinez AA, Chakravarty AB, Quenneville CE. The effect of impact duration on the axial fracture tolerance of the isolated tibia during automotive and military impacts. J Mech Behav Biomed Mater. 2018, 78:315-20. 10.1016\/j.jmbbm.2017.11.013","journal-title":"J Mech Behav Biomed Mater"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1080\/15389588.2024.2406418","article-title":"Determination of distal fibula fracture for prediction of ankle injuries","volume":"25","author":"Noss J","year":"2024","unstructured":"Noss J, Donlon JP, Iyer R, Hallman J, Forman J. Determination of distal fibula fracture for prediction of ankle injuries. Traffic Inj Prev. 2024, 25:S145-50. 10.1080\/15389588.2024.2406418","journal-title":"Traffic Inj Prev"},{"key":"ref12","article-title":"Finite element analysis of tibial fractures","volume":"57","author":"Wong C","year":"2010","unstructured":"Wong C, Mikkelsen P, Hansen LB, Darvann T, Gebuhr P. Finite element analysis of tibial fractures. Dan Med Bull. 2010, 57:A4148.","journal-title":"Dan Med Bull"},{"key":"ref13","article-title":"The material properties of human tibia cortical bone in tension and compression: implications for the tibia index","author":"Kemper A","unstructured":"Kemper A, McNally C, Kennedy E. The material properties of human tibia cortical bone in tension and compression: implications for the tibia index. Proceedings of the 20th Enhanced Safety of Vehicles Conference. 2007 (ed): Lyon, France; 7-470."},{"key":"ref14","doi-asserted-by":"crossref","DOI":"10.1016\/0001-4575(82)90076-8","article-title":"Lower extremity injuries in automobile crashes","volume":"14","author":"Huelke DF","year":"1982","unstructured":"Huelke DF, O'Day J, States JD. Lower extremity injuries in automobile crashes. Accid Anal Prev. 1982, 14:95-106.","journal-title":"Accid Anal Prev"},{"key":"ref15","article-title":"Mechanical Testing and Modelling of a Bone-Implant Construct (Doctoral Dissertation)","author":"Grant C","year":"2012","unstructured":"Grant C. Mechanical Testing and Modelling of a Bone-Implant Construct (Doctoral Dissertation). Queensland University of Technology, 2012."}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/454613-biomechanical-fracture-thresholds-of-the-tibia-and-fibula-under-axial-and-multi-axial-loading-a-systematic-review","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,27]],"date-time":"2026-01-27T08:01:52Z","timestamp":1769500912000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/454613-biomechanical-fracture-thresholds-of-the-tibia-and-fibula-under-axial-and-multi-axial-loading-a-systematic-review"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1,27]]},"references-count":15,"URL":"https:\/\/doi.org\/10.7759\/cureus.102362","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2026,1,27]]}}}