{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,18]],"date-time":"2026-02-18T01:15:51Z","timestamp":1771377351311,"version":"3.50.1"},"reference-count":21,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,2,17]]},"DOI":"10.7759\/cureus.103793","type":"journal-article","created":{"date-parts":[[2026,2,18]],"date-time":"2026-02-18T00:49:14Z","timestamp":1771375754000},"source":"Crossref","is-referenced-by-count":0,"title":["Performance Assessment of \u03bcTASWako i50, a New Microfluidic Immunoassay System for Hepatocellular Carcinoma Biomarkers AFP, AFP-L3%, and PIVKA-II"],"prefix":"10.7759","author":[{"given":"Tomoyasu","family":"Yoshikawa","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takuma","family":"Ohtsubo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Isao","family":"Yamaguchi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiroko","family":"Nishihara","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yasuhiro","family":"Mori","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiroyuki","family":"Yamada","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hidenori","family":"Toyoda","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tomohisa","family":"Kawabata","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shinjiro","family":"Matsuda","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1016\/0925-4005(90)80209-I","article-title":"Miniaturized total chemical analysis systems: a novel concept for chemical sensing","volume":"1","author":"Manz A","year":"1990","unstructured":"Manz A, Graber N, Widmer HM. Miniaturized total chemical analysis systems: a novel concept for chemical sensing. Sens Actuators B Chem. 1990, 1:244-8. 10.1016\/0925-4005(90)80209-I","journal-title":"Sens Actuators B Chem"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1021\/ac00041a030","article-title":"Capillary electrophoresis and sample injection systems integrated on a planar glass chip","volume":"64","author":"Harrison DJ","year":"1992","unstructured":"Harrison DJ, Manz A, Fan ZH, Ludi H, Widmer HM. Capillary electrophoresis and sample injection systems integrated on a planar glass chip. Anal Chem. 1992, 64:1926-32. 10.1021\/ac00041a030","journal-title":"Anal Chem"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1021\/ac0202435","article-title":"Micro total analysis systems. 1. Introduction, theory, and technology","volume":"74","author":"Reyes DR","year":"2002","unstructured":"Reyes DR, Iossifidis D, Auroux PA, Manz A. Micro total analysis systems. 1. Introduction, theory, and technology. Anal Chem. 2002, 74:2623-36. 10.1021\/ac0202435","journal-title":"Anal Chem"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1021\/ac020239t","article-title":"Micro total analysis systems. 2. Analytical standard operations and applications","volume":"74","author":"Auroux PA","year":"2002","unstructured":"Auroux PA, Iossifidis D, Reyes DR, Manz A. Micro total analysis systems. 2. Analytical standard operations and applications. Anal Chem. 2002, 74:2637-52. 10.1021\/ac020239t","journal-title":"Anal Chem"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1002\/elps.200700898","article-title":"\u201cElectrokinetic analyte transport assay\u201d for \u03b1-fetoprotein immunoassay integrates mixing, reaction and separation on-chip","volume":"29","author":"Kawabata T","year":"2008","unstructured":"Kawabata T, Wada HG, Watanabe M, Satomura S. \u201cElectrokinetic analyte transport assay\u201d for \u03b1-fetoprotein immunoassay integrates mixing, reaction and separation on-chip. Electrophoresis. 2008, 29:1399-406. 10.1002\/elps.200700898","journal-title":"Electrophoresis"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1021\/ac701709n","article-title":"Controlling data quality and reproducibility of a high-sensitivity immunoassay using isotachophoresis in a microchip","volume":"80","author":"Park CC","year":"2008","unstructured":"Park CC, Kazakova I, Kawabata T, Spaid M, Chien RL, Wada HG, Satomura S. Controlling data quality and reproducibility of a high-sensitivity immunoassay using isotachophoresis in a microchip. Anal Chem. 2008, 80:808-14. 10.1021\/ac701709n","journal-title":"Anal Chem"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.3390\/proteomes3010042","article-title":"The cutting edge of affinity electrophoresis technology","volume":"3","author":"Kinoshita E","year":"2015","unstructured":"Kinoshita E, Kinoshita-Kikuta E, Koike T. The cutting edge of affinity electrophoresis technology. Proteomes. 2015, 3:42-55. 10.3390\/proteomes3010042","journal-title":"Proteomes"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1016\/j.ab.2009.02.030","article-title":"Automated immunoassay system for AFP-L3% using on-chip electrokinetic reaction and separation by affinity electrophoresis","volume":"388","author":"Kagebayashi C","year":"2009","unstructured":"Kagebayashi C, Yamaguchi I, Akinaga A, et al.. Automated immunoassay system for AFP-L3% using on-chip electrokinetic reaction and separation by affinity electrophoresis. Anal Biochem. 2009, 388:306-11. 10.1016\/j.ab.2009.02.030","journal-title":"Anal Biochem"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1016\/S0168-8278(99)80016-6","article-title":"Clinical utility of Lens culinaris agglutinin-reactive alpha-fetoprotein in small hepatocellular carcinoma: special reference to imaging diagnosis","volume":"30","author":"Kumada T","year":"1999","unstructured":"Kumada T, Nakano S, Takeda I, et al.. Clinical utility of Lens culinaris agglutinin-reactive alpha-fetoprotein in small hepatocellular carcinoma: special reference to imaging diagnosis. J Hepatol. 1999, 30:125-30. 10.1016\/S0168-8278(99)80016-6","journal-title":"J Hepatol"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.3109\/00365521.2015.1082190","article-title":"Combined use of AFP, PIVKA-II, and AFP-L3 as tumor markers enhances diagnostic accuracy for hepatocellular carcinoma in cirrhotic patients","volume":"51","author":"Lim TS","year":"2016","unstructured":"Lim TS, Kim DY, Han KH, et al.. Combined use of AFP, PIVKA-II, and AFP-L3 as tumor markers enhances diagnostic accuracy for hepatocellular carcinoma in cirrhotic patients. Scand J Gastroenterol. 2016, 51:344-53. 10.3109\/00365521.2015.1082190","journal-title":"Scand J Gastroenterol"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.3390\/jcm12030949","article-title":"The performance of GALAD score for diagnosing hepatocellular carcinoma in patients with chronic liver diseases: a systematic review and meta-analysis","volume":"12","author":"Guan MC","year":"2023","unstructured":"Guan MC, Zhang SY, Ding Q, et al.. The performance of GALAD score for diagnosing hepatocellular carcinoma in patients with chronic liver diseases: a systematic review and meta-analysis. J Clin Med. 2023, 12:949. 10.3390\/jcm12030949","journal-title":"J Clin Med"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.19186\/BC_2021.043","article-title":"Clinical assessment of FREND COVID-19 Ag test in an unselected population referred for routine SARS-CoV-2 testing","volume":"45","author":"Salvagno GL","year":"2021","unstructured":"Salvagno GL, Gianfilippi G, Negrini D, Pighi L, De Nitto S, Henry BM, Lippi G. Clinical assessment of FREND COVID-19 Ag test in an unselected population referred for routine SARS-CoV-2 testing. Biochim Clin. 2021, 45:395-9. 10.19186\/BC_2021.043","journal-title":"Biochim Clin"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1021\/ac402761s","article-title":"Microfluidic chip with integrated electrical cell-impedance sensing for monitoring single cancer cell migration in three-dimensional matrixes","volume":"85","author":"Nguyen TA","year":"2013","unstructured":"Nguyen TA, Yin TI, Reyes D, Urban GA. Microfluidic chip with integrated electrical cell-impedance sensing for monitoring single cancer cell migration in three-dimensional matrixes. Anal Chem. 2013, 85:11068-76. 10.1021\/ac402761s","journal-title":"Anal Chem"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1021\/acs.analchem.9b05738","article-title":"Microfluidic platform for the isolation of cancer-cell subpopulations based on single-cell glycolysis","volume":"92","author":"Zielke C","year":"2020","unstructured":"Zielke C, Pan CW, Gutierrez Ramirez AJ, et al.. Microfluidic platform for the isolation of cancer-cell subpopulations based on single-cell glycolysis. Anal Chem. 2020, 92:6949-57. 10.1021\/acs.analchem.9b05738","journal-title":"Anal Chem"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.1021\/acs.analchem.0c04896","article-title":"Attomolar-level ultrasensitive and multiplex microRNA detection enabled by a nanomaterial locally assembled microfluidic biochip for cancer diagnosis","volume":"93","author":"Chu Y","year":"2021","unstructured":"Chu Y, Gao Y, Tang W, et al.. Attomolar-level ultrasensitive and multiplex microRNA detection enabled by a nanomaterial locally assembled microfluidic biochip for cancer diagnosis. Anal Chem. 2021, 93:5129-36. 10.1021\/acs.analchem.0c04896","journal-title":"Anal Chem"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.1007\/s00216-016-9880-6","article-title":"Glycans and glycoproteins as specific biomarkers for cancer","volume":"409","author":"Kailemia MJ","year":"2017","unstructured":"Kailemia MJ, Park D, Lebrilla CB. Glycans and glycoproteins as specific biomarkers for cancer. Anal Bioanal Chem. 2017, 409:395-410. 10.1007\/s00216-016-9880-6","journal-title":"Anal Bioanal Chem"},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.3390\/ijms18020470","article-title":"An automated micro-total immunoassay system for measuring cancer-associated \u03b12,3-linked Sialyl N-glycan-carrying prostate-specific antigen may improve the accuracy of prostate cancer diagnosis","volume":"18","author":"Ishikawa T","year":"2017","unstructured":"Ishikawa T, Yoneyama T, Tobisawa Y, et al.. An automated micro-total immunoassay system for measuring cancer-associated \u03b12,3-linked Sialyl N-glycan-carrying prostate-specific antigen may improve the accuracy of prostate cancer diagnosis. Int J Mol Sci. 2017, 18:470. 10.3390\/ijms18020470","journal-title":"Int J Mol Sci"},{"key":"ref18","doi-asserted-by":"publisher","DOI":"10.1002\/ijc.33517","article-title":"Serum core-type fucosylated prostate-specific antigen index for the detection of high-risk prostate cancer","volume":"148","author":"Fujita K","year":"2021","unstructured":"Fujita K, Hatano K, Tomiyama E, et al.. Serum core-type fucosylated prostate-specific antigen index for the detection of high-risk prostate cancer. Int J Cancer. 2021, 148:3111-8. 10.1002\/ijc.33517","journal-title":"Int J Cancer"},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.3748\/wjg.v19.i3.339","article-title":"Diagnostic value of AFP-L3 and PIVKA-II in hepatocellular carcinoma according to total-AFP","volume":"19","author":"Choi JY","year":"2013","unstructured":"Choi JY, Jung SW, Kim HY, Kim M, Kim Y, Kim DG, Oh EJ. Diagnostic value of AFP-L3 and PIVKA-II in hepatocellular carcinoma according to total-AFP. World J Gastroenterol. 2013, 19:339-46. 10.3748\/wjg.v19.i3.339","journal-title":"World J Gastroenterol"},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.3233\/TUB-220016","article-title":"HE4 and CA125 serum biomarker monitoring in women with epithelial ovarian cancer","volume":"44","author":"Samborski A","year":"2022","unstructured":"Samborski A, Miller MC, Blackman A, et al.. HE4 and CA125 serum biomarker monitoring in women with epithelial ovarian cancer. Tumour Biol. 2022, 44:205-13. 10.3233\/TUB-220016","journal-title":"Tumour Biol"},{"key":"ref21","doi-asserted-by":"publisher","DOI":"10.1038\/s41416-021-01637-x","article-title":"Simultaneous analysis of serum \u03b12,3-linked sialylation and core-type fucosylation of prostate-specific antigen for the detection of high-grade prostate cancer","volume":"126","author":"Hatano K","year":"2022","unstructured":"Hatano K, Yoneyama T, Hatakeyama S, et al.. Simultaneous analysis of serum \u03b12,3-linked sialylation and core-type fucosylation of prostate-specific antigen for the detection of high-grade prostate cancer. Br J Cancer. 2022, 126:764-70. 10.1038\/s41416-021-01637-x","journal-title":"Br J Cancer"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/417351-performance-assessment-of-taswako-i50-a-new-microfluidic-immunoassay-system-for-hepatocellular-carcinoma-biomarkers-afp-afp-l3-and-pivka-ii","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,18]],"date-time":"2026-02-18T00:49:15Z","timestamp":1771375755000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/417351-performance-assessment-of-taswako-i50-a-new-microfluidic-immunoassay-system-for-hepatocellular-carcinoma-biomarkers-afp-afp-l3-and-pivka-ii"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2,17]]},"references-count":21,"URL":"https:\/\/doi.org\/10.7759\/cureus.103793","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2026,2,17]]}}}