{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,1]],"date-time":"2026-03-01T04:57:02Z","timestamp":1772341022607,"version":"3.50.1"},"reference-count":15,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,2,28]]},"DOI":"10.7759\/cureus.104461","type":"journal-article","created":{"date-parts":[[2026,3,1]],"date-time":"2026-03-01T04:16:56Z","timestamp":1772338616000},"source":"Crossref","is-referenced-by-count":0,"title":["Development and Validation of a Wearable Softness Sensor Based on Fingernail Deformation and an Inertial Measurement Unit for Quantifying Palpation"],"prefix":"10.7759","author":[{"given":"Shohei","family":"Ueda","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiroya","family":"Fukuda","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1097\/01.brs.0000141178.98157.8e","article-title":"Reliability of spinal palpation for diagnosis of back and neck pain: a systematic review of the literature","volume":"29","author":"Seffinger MA","year":"2004","unstructured":"Seffinger MA, Najm WI, Mishra SI, Adams A, Dickerson VM, Murphy LS, Reinsch S. Reliability of spinal palpation for diagnosis of back and neck pain: a systematic review of the literature. Spine (Phila Pa 1976). 2004, 29:E413-25. 10.1097\/01.brs.0000141178.98157.8e","journal-title":"Spine (Phila Pa 1976)"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1097\/ACM.0000000000005614","article-title":"Sensor-based discovery of search and palpation modes in the clinical breast examination","volume":"99","author":"Laufer S","year":"2024","unstructured":"Laufer S, Klatzky RL, Pugh CM. Sensor-based discovery of search and palpation modes in the clinical breast examination. Acad Med. 2024, 99:S89-94. 10.1097\/ACM.0000000000005614","journal-title":"Acad Med"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijhcs.2020.102394","article-title":"A technology-aided multi-modal training approach to assist abdominal palpation training and its assessment in medical education","volume":"137","author":"Asadipour A","year":"2020","unstructured":"Asadipour A, Debattista K, Patel V, et al.. A technology-aided multi-modal training approach to assist abdominal palpation training and its assessment in medical education. Int J Hum Comput Stud. 2020, 137:102394. 10.1016\/j.ijhcs.2020.102394","journal-title":"Int J Hum Comput Stud"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0846.1999.tb00136.x","article-title":"Palpation of the skin with a robot finger: an attempt to measure skin stiffness with a probe loaded with a newly developed tactile vibration sensor and displacement sensor","volume":"5","author":"Sasai S","year":"1999","unstructured":"Sasai S, Zhen YX, Suetake T, et al.. Palpation of the skin with a robot finger: an attempt to measure skin stiffness with a probe loaded with a newly developed tactile vibration sensor and displacement sensor. Skin Res Technol. 1999, 5:237-46. 10.1111\/j.1600-0846.1999.tb00136.x","journal-title":"Skin Res Technol"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1117\/1.JBO.20.1.016013","article-title":"Optical palpation in vivo: imaging human skin lesions using mechanical contrast","volume":"20","author":"Es'haghian S","year":"2015","unstructured":"Es'haghian S, Kennedy KM, Gong P, Sampson DD, McLaughlin RA, Kennedy BF. Optical palpation in vivo: imaging human skin lesions using mechanical contrast. J Biomed Opt. 2015, 20:16013. 10.1117\/1.JBO.20.1.016013","journal-title":"J Biomed Opt"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2017.2739681","article-title":"A surgical palpation probe with 6-axis force\/torque sensing capability for minimally invasive surgery","volume":"65","author":"Kim U","year":"2018","unstructured":"Kim U, Kim YB, Seok DY, et al.. A surgical palpation probe with 6-axis force\/torque sensing capability for minimally invasive surgery. IEEE Trans Ind Electron. 2018, 65:2755-65. 10.1109\/TIE.2017.2739681","journal-title":"IEEE Trans Ind Electron"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.14326\/abe.9.197","article-title":"Evaluation of venipuncture techniques based on measurements of haptic sense and finger motion","volume":"9","author":"Sonoda M","year":"2020","unstructured":"Sonoda M, Sasagawa K, Fujisaki K, et al.. Evaluation of venipuncture techniques based on measurements of haptic sense and finger motion. Adv Biomed Eng. 2020, 9:197-201. 10.14326\/abe.9.197","journal-title":"Adv Biomed Eng"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1109\/TRA.2003.820931","article-title":"Measurement of finger posture and three-axis fingertip touch force using fingernail sensors","volume":"20","author":"Mascaro SA","year":"2004","unstructured":"Mascaro SA, Asada HH. Measurement of finger posture and three-axis fingertip touch force using fingernail sensors. IEEE Trans Robot Autom. 2004, 20:26-35. 10.1109\/TRA.2003.820931","journal-title":"IEEE Trans Robot Autom"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1016\/j.wear.2016.11.010","article-title":"Measurement of finger pad forces and friction using finger nail mounted strain gauges","volume":"376","author":"Popplewell H","year":"2017","unstructured":"Popplewell H, Carre M, Lewis R. Measurement of finger pad forces and friction using finger nail mounted strain gauges. Wear. 2017, 376:295-304. 10.1016\/j.wear.2016.11.010","journal-title":"Wear"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-018-36834-x","article-title":"Wearable nail deformation sensing for behavioral and biomechanical monitoring and human-computer interaction","volume":"8","author":"Sakuma K","year":"2018","unstructured":"Sakuma K, Abrami A, Blumrosen G, et al.. Wearable nail deformation sensing for behavioral and biomechanical monitoring and human-computer interaction. Sci Rep. 2018, 8:18031. 10.1038\/s41598-018-36834-x","journal-title":"Sci Rep"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1109\/WHC.2011.5945506","article-title":"Wearable contact force sensor system based on fingerpad deformation","volume":"2011","author":"Nakatani M","year":"2011","unstructured":"Nakatani M, Kawasoe T, Shiojima K, et al.. Wearable contact force sensor system based on fingerpad deformation. IEEE World Haptics Conf. 2011, 2011:323-28. 10.1109\/WHC.2011.5945506","journal-title":"IEEE World Haptics Conf"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1109\/EMBC58623.2025.11252731","article-title":"Development of a simple softness measurement method using a wearable force sensor and depth camera for remote edema palpation","volume":"2025","author":"Ebina K","year":"2025","unstructured":"Ebina K, Goto M, Seshimo H. Development of a simple softness measurement method using a wearable force sensor and depth camera for remote edema palpation. Annu Int Conf IEEE Eng Med Biol Soc. 2025, 2025:1-7. 10.1109\/EMBC58623.2025.11252731","journal-title":"Annu Int Conf IEEE Eng Med Biol Soc"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0846.2007.00250.x","article-title":"Strain in the nail at fingertip compression","volume":"13","author":"Sakai N","year":"2007","unstructured":"Sakai N, Shimawaki S. Strain in the nail at fingertip compression. Skin Res Technol. 2007, 13:449-53. 10.1111\/j.1600-0846.2007.00250.x","journal-title":"Skin Res Technol"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1299\/jbse.14-00316","article-title":"Thumbnail strain during pressing and plucking of a string","volume":"10","author":"Shimawaki S","year":"2015","unstructured":"Shimawaki S, Nakayama A, Nakabayashi M, et al.. Thumbnail strain during pressing and plucking of a string. J Biomech Sci Eng. 2015, 10:14-00316. 10.1299\/jbse.14-00316","journal-title":"J Biomech Sci Eng"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.1109\/ICORR.2011.5975346","article-title":"Estimation of IMU and MARG orientation using a gradient descent algorithm","volume":"2011","author":"Madgwick SO","year":"2011","unstructured":"Madgwick SO, Harrison AJ, Vaidyanathan A. Estimation of IMU and MARG orientation using a gradient descent algorithm. IEEE Int Conf Rehabil Robot. 2011, 2011:5975346. 10.1109\/ICORR.2011.5975346","journal-title":"IEEE Int Conf Rehabil Robot"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/467108-development-and-validation-of-a-wearable-softness-sensor-based-on-fingernail-deformation-and-an-inertial-measurement-unit-for-quantifying-palpation","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,1]],"date-time":"2026-03-01T04:16:57Z","timestamp":1772338617000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/467108-development-and-validation-of-a-wearable-softness-sensor-based-on-fingernail-deformation-and-an-inertial-measurement-unit-for-quantifying-palpation"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2,28]]},"references-count":15,"URL":"https:\/\/doi.org\/10.7759\/cureus.104461","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2026,2,28]]}}}