{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,5]],"date-time":"2026-03-05T15:19:02Z","timestamp":1772723942319,"version":"3.50.1"},"reference-count":20,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,3,5]]},"DOI":"10.7759\/cureus.104709","type":"journal-article","created":{"date-parts":[[2026,3,5]],"date-time":"2026-03-05T14:17:29Z","timestamp":1772720249000},"source":"Crossref","is-referenced-by-count":0,"title":["Suspected Hypersensitivity Reaction to Titanium Screws Following Kalish Osteotomy for Hallux Valgus"],"prefix":"10.7759","author":[{"given":"Samy","family":"Ajarrag","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marie-Christine","family":"Torchon","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1016\/j.pmatsci.2008.06.004","article-title":"Ti based biomaterials, the ultimate choice for orthopaedic implants - a review","volume":"54","author":"Geetha M","year":"2009","unstructured":"Geetha M, Singh AK, Asokamani R, Gogia AK. Ti based biomaterials, the ultimate choice for orthopaedic implants - a review. Prog Mater Sci. 2009, 54:397-425. 10.1016\/j.pmatsci.2008.06.004","journal-title":"Prog Mater Sci"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.3390\/ma7128168","article-title":"Biocompatibility of advanced manufactured titanium implants-a review","volume":"7","author":"Sidambe AT","year":"2014","unstructured":"Sidambe AT. Biocompatibility of advanced manufactured titanium implants-a review. Materials (Basel). 2014, 7:8168-88. 10.3390\/ma7128168","journal-title":"Materials (Basel)"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1007\/s40629-014-0023-3","article-title":"Clinical and diagnostic challenges of metal implant allergy using the example of orthopaedic surgical implants: Part 15 of the Series Molecular Allergology","volume":"23","author":"Thomas P","year":"2014","unstructured":"Thomas P. Clinical and diagnostic challenges of metal implant allergy using the example of orthopaedic surgical implants: Part 15 of the Series Molecular Allergology. Allergo J Int. 2014, 23:179-85. 10.1007\/s40629-014-0023-3","journal-title":"Allergo J Int"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1111\/jdv.20026","article-title":"A literature review and expert consensus statement on diagnostics in suspected metal implant allergy","volume":"38","author":"Thomas P","year":"2024","unstructured":"Thomas P, Arenberger P, Bader R, et al.. A literature review and expert consensus statement on diagnostics in suspected metal implant allergy. J Eur Acad Dermatol Venereol. 2024, 38:1471-7. 10.1111\/jdv.20026","journal-title":"J Eur Acad Dermatol Venereol"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1053\/j.jfas.2018.11.031","article-title":"Type IV cell-mediated hypersensitivity reaction caused by titanium implant following double calcaneal osteotomy and first metatarsal-cuneiform arthrodesis: a case report and review of the literature","volume":"58","author":"Razzante MC","year":"2019","unstructured":"Razzante MC, Ehredt DJ, Clougherty CO, et al.. Type IV cell-mediated hypersensitivity reaction caused by titanium implant following double calcaneal osteotomy and first metatarsal-cuneiform arthrodesis: a case report and review of the literature. J Foot Ankle Surg. 2019, 58:974-9. 10.1053\/j.jfas.2018.11.031","journal-title":"J Foot Ankle Surg"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1155\/2021\/5592934","article-title":"A clinical case report of a potential acute allergic reaction with titanium dental implant","volume":"2021","author":"Alqahtani AR","year":"2021","unstructured":"Alqahtani AR, Gufran K, Silva F, Rocha MG, Chang J. A clinical case report of a potential acute allergic reaction with titanium dental implant. Case Rep Dent. 2021, 2021:5592934. 10.1155\/2021\/5592934","journal-title":"Case Rep Dent"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1016\/j.jaip.2015.07.011","article-title":"Allergy to surgical implants","volume":"3","author":"Pacheco KA","year":"2015","unstructured":"Pacheco KA. Allergy to surgical implants. J Allergy Clin Immunol Pract. 2015, 3:683-95. 10.1016\/j.jaip.2015.07.011","journal-title":"J Allergy Clin Immunol Pract"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1111\/j.1708-8208.2010.00330.x","article-title":"Is titanium sensitivity associated with allergic reactions in patients with dental implants? A systematic review","volume":"15","author":"Javed F","year":"2013","unstructured":"Javed F, Al-Hezaimi K, Almas K, Romanos GE. Is titanium sensitivity associated with allergic reactions in patients with dental implants? A systematic review. Clin Implant Dent Relat Res. 2013, 15:47-52. 10.1111\/j.1708-8208.2010.00330.x","journal-title":"Clin Implant Dent Relat Res"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.2147\/ijn.s1796","article-title":"Formation of potential titanium antigens based on protein binding to titanium dioxide nanoparticles","volume":"3","author":"Vamanu CI","year":"2008","unstructured":"Vamanu CI, H\u00f8l PJ, Allouni ZE, Elsayed S, Gjerdet NR. Formation of potential titanium antigens based on protein binding to titanium dioxide nanoparticles. Int J Nanomedicine. 2008, 3:69-74. 10.2147\/ijn.s1796","journal-title":"Int J Nanomedicine"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.3389\/fimmu.2019.02662","article-title":"Free radical production, inflammation and apoptosis in patients treated with titanium mandibular fixations-an observational study","volume":"10","author":"Borys J","year":"2019","unstructured":"Borys J, Maciejczyk M, Antonowicz B, Sidun J, \u015awiderska M, Zalewska A. Free radical production, inflammation and apoptosis in patients treated with titanium mandibular fixations-an observational study. Front Immunol. 2019, 10:2662. 10.3389\/fimmu.2019.02662","journal-title":"Front Immunol"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1186\/s40729-024-00578-3","article-title":"The systemic and local interactions related to titanium implant corrosion and hypersensitivity reactions: a narrative review of the literature","volume":"10","author":"Swalsky A","year":"2024","unstructured":"Swalsky A, Noumbissi SS, Wiedemann TG. The systemic and local interactions related to titanium implant corrosion and hypersensitivity reactions: a narrative review of the literature. Int J Implant Dent. 2024, 10:58. 10.1186\/s40729-024-00578-3","journal-title":"Int J Implant Dent"},{"key":"ref12","article-title":"Indications of implant removal: a study of 83 cases","volume":"11","author":"Haseeb M","year":"2017","unstructured":"Haseeb M, Butt MF, Altaf T, Muzaffar K, Gupta A, Jallu A. Indications of implant removal: a study of 83 cases. Int J Health Sci (Qassim). 2017, 11:1-7.","journal-title":"Int J Health Sci (Qassim)"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.J.01756","article-title":"The benefits of implant removal from the foot and ankle","volume":"94","author":"Williams AA","year":"2012","unstructured":"Williams AA, Witten DM, Duester R, Chou LB. The benefits of implant removal from the foot and ankle. J Bone Joint Surg Am. 2012, 94:1316-20. 10.2106\/JBJS.J.01756","journal-title":"J Bone Joint Surg Am"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1155\/2021\/5515401","article-title":"Delayed titanium hypersensitivity and retained foreign body causing late abdominal complications","volume":"2021","author":"Jain MS","year":"2021","unstructured":"Jain MS, Lingarajah S, Luvsannyam E, et al.. Delayed titanium hypersensitivity and retained foreign body causing late abdominal complications. Case Rep Surg. 2021, 2021:5515401. 10.1155\/2021\/5515401","journal-title":"Case Rep Surg"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.94B8.28135","article-title":"Metal hypersensitivity testing in patients undergoing joint replacement: a systematic review","volume":"94","author":"Granchi D","year":"2012","unstructured":"Granchi D, Cenni E, Giunti A, Baldini N. Metal hypersensitivity testing in patients undergoing joint replacement: a systematic review. J Bone Joint Surg Br. 2012, 94:1126-34. 10.1302\/0301-620X.94B8.28135","journal-title":"J Bone Joint Surg Br"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.7759\/cureus.5761","article-title":"Utility of patch testing and lymphocyte transformation testing in the evaluation of metal allergy in patients with orthopedic implants","volume":"11","author":"Richards LJ","year":"2019","unstructured":"Richards LJ, Streifel A, Rodrigues JM. Utility of patch testing and lymphocyte transformation testing in the evaluation of metal allergy in patients with orthopedic implants. Cureus. 2019, 11:e5761. 10.7759\/cureus.5761","journal-title":"Cureus"},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.1016\/j.jaci.2022.12.470","article-title":"Irritant reaction to titanium oxalate on preoperative patch testing before NUSS procedure","volume":"151","author":"Wang B","year":"2023","unstructured":"Wang B, Kumar S. Irritant reaction to titanium oxalate on preoperative patch testing before NUSS procedure. J Allergy Clin Immunol. 2023, 151:AB151. 10.1016\/j.jaci.2022.12.470","journal-title":"J Allergy Clin Immunol"},{"key":"ref18","article-title":"Patch testing for evaluation of hypersensitivity to implanted metal devices: a perspective from the American contact","volume":"27(5)","author":"Schalock PC","year":"2016","unstructured":"Schalock PC, Crawford G, Nedorost S, et al.. Patch testing for evaluation of hypersensitivity to implanted metal devices: a perspective from the American contact. Dermatitis Society. Dermatitis. 2016, 27(5):241-7.","journal-title":"Dermatitis Society. Dermatitis"},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.1002\/ksa.12706","article-title":"Metal sensitivity in total joint arthroplasty: none of the current diagnostic tests are reliable, sensitive and specific enough to guide treatment decisions!","volume":"33","author":"Longo UG","year":"2025","unstructured":"Longo UG, Intermesoli G, Di Tommaso R, Lalli A, Violante B, Hirschmann MT. Metal sensitivity in total joint arthroplasty: none of the current diagnostic tests are reliable, sensitive and specific enough to guide treatment decisions!. Knee Surg Sports Traumatol Arthrosc. 2025, 33:3269-85. 10.1002\/ksa.12706","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.1186\/s40729-022-00451-1","article-title":"The German S3 guideline on titanium hypersensitivity in implant dentistry: consensus statements and recommendations","volume":"8","author":"M\u00fcller-Heupt LK","year":"2022","unstructured":"M\u00fcller-Heupt LK, Schiegnitz E, Kaya S, Jacobi-Gresser E, K\u00e4mmerer PW, Al-Nawas B. The German S3 guideline on titanium hypersensitivity in implant dentistry: consensus statements and recommendations. Int J Implant Dent. 2022, 8:51. 10.1186\/s40729-022-00451-1","journal-title":"Int J Implant Dent"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/463348-suspected-hypersensitivity-reaction-to-titanium-screws-following-kalish-osteotomy-for-hallux-valgus","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,5]],"date-time":"2026-03-05T14:17:29Z","timestamp":1772720249000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/463348-suspected-hypersensitivity-reaction-to-titanium-screws-following-kalish-osteotomy-for-hallux-valgus"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,5]]},"references-count":20,"URL":"https:\/\/doi.org\/10.7759\/cureus.104709","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2026,3,5]]}}}