{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,21]],"date-time":"2026-03-21T18:01:38Z","timestamp":1774116098413,"version":"3.50.1"},"reference-count":18,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,3,21]]},"DOI":"10.7759\/cureus.105610","type":"journal-article","created":{"date-parts":[[2026,3,21]],"date-time":"2026-03-21T17:47:47Z","timestamp":1774115267000},"source":"Crossref","is-referenced-by-count":0,"title":["Double-Row Suture Anchor Fixation for Inferior Pole Patella Fracture: A Novel Technique"],"prefix":"10.7759","author":[{"given":"Qing Hang","family":"Tan","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Foong","family":"Wei Sheng","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dalun","family":"Leong","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ing How","family":"Moo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2017.07.013","article-title":"Management of displaced inferior patellar pole fractures with modified tension band technique combined with cable cerclage using Cable Grip System","volume":"48","author":"Yang X","year":"2017","unstructured":"Yang X, Wu Q, Lai CH, Wang X. Management of displaced inferior patellar pole fractures with modified tension band technique combined with cable cerclage using Cable Grip System. Injury. 2017, 48:2348-53. 10.1016\/j.injury.2017.07.013","journal-title":"Injury"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1177\/22104917251358496","article-title":"A review of a new technique for comminuted inferior pole patellar fracture\u2014modified non-metallic separate vertical wiring (NM-SVW)","author":"S. L. J. Yuen and M H. Chau","year":"2025","unstructured":"S. L. J. Yuen and M H. Chau. A review of a new technique for comminuted inferior pole patellar fracture\u2014modified non-metallic separate vertical wiring (NM-SVW). J Orthop Trauma Rehabil. 2025, 10.1177\/22104917251358496","journal-title":"J Orthop Trauma Rehabil"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1186\/s40634-023-00622-y","article-title":"Surgical treatment of inferior pole fractures of the patella: a systematic review","volume":"10","author":"Chang CH","year":"2023","unstructured":"Chang CH, Shih CA, Kuan FC, Hong CK, Su WR, Hsu KL. Surgical treatment of inferior pole fractures of the patella: a systematic review. J Exp Orthop. 2023, 10:58. 10.1186\/s40634-023-00622-y","journal-title":"J Exp Orthop"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1186\/s13018-021-02519-x","article-title":"Fracture of the inferior pole of the patella: tension band wiring versus transosseous reattachment","volume":"16","author":"Chang CH","year":"2021","unstructured":"Chang CH, Chuang HC, Su WR, Kuan FC, Hong CK, Hsu KL. Fracture of the inferior pole of the patella: tension band wiring versus transosseous reattachment. J Orthop Surg Res. 2021, 16:365. 10.1186\/s13018-021-02519-x","journal-title":"J Orthop Surg Res"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1097\/00005131-199306000-00010","article-title":"Partial patellectomy for patellar fracture: tension band wiring and early mobilization","volume":"7","author":"Hung LK","year":"1993","unstructured":"Hung LK, Lee SY, Leung KS, Chan KM, Nicholl LA. Partial patellectomy for patellar fracture: tension band wiring and early mobilization. J Orthop Trauma. 1993, 7:252-60. 10.1097\/00005131-199306000-00010","journal-title":"J Orthop Trauma"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2016.05.039","article-title":"Non-metallic implant for patellar fracture fixation: a systematic review","volume":"47","author":"Camarda L","year":"2016","unstructured":"Camarda L, Morello S, Balistreri F, D'Arienzo A, D'Arienzo M. Non-metallic implant for patellar fracture fixation: a systematic review. Injury. 2016, 47:1613-7. 10.1016\/j.injury.2016.05.039","journal-title":"Injury"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1016\/s0140-6736(74)90884-8","article-title":"Measurement of pain","volume":"2","author":"Huskisson EC","year":"1974","unstructured":"Huskisson EC. Measurement of pain. Lancet. 1974, 2:1127-31. 10.1016\/s0140-6736(74)90884-8","journal-title":"Lancet"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1016\/s0749-8063(05)80366-4","article-title":"Scoring of patellofemoral disorders","volume":"9","author":"Kujala UM","year":"1993","unstructured":"Kujala UM, Jaakkola LH, Koskinen SK, Taimela S, Hurme M, Nelimarkka O. Scoring of patellofemoral disorders. Arthroscopy. 1993, 9:159-63. 10.1016\/s0749-8063(05)80366-4","journal-title":"Arthroscopy"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1186\/s12893-022-01790-x","article-title":"Treatment of inferior pole fracture of the patella with tension-free external immobilization","volume":"22","author":"Pu S","year":"2022","unstructured":"Pu S, Chen Y, Liang J, Xu Y, Zhao Y. Treatment of inferior pole fracture of the patella with tension-free external immobilization. BMC Surg. 2022, 22:337. 10.1186\/s12893-022-01790-x","journal-title":"BMC Surg"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1007\/s00776-014-0658-4","article-title":"Predictors for nonunion, reoperation and infection after surgical fixation of patellar fracture","volume":"20","author":"Kadar A","year":"2015","unstructured":"Kadar A, Sherman H, Glazer Y, Katz E, Steinberg EL. Predictors for nonunion, reoperation and infection after surgical fixation of patellar fracture. J Orthop Sci. 2015, 20:168-73. 10.1007\/s00776-014-0658-4","journal-title":"J Orthop Sci"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1177\/23259671211022245","article-title":"Suture anchor versus transosseous tunnel repair for inferior pole patellar fractures treated with partial patellectomy and tendon advancement: a biomechanical study","volume":"9","author":"O'Donnell R","year":"2021","unstructured":"O'Donnell R, Lemme NJ, Marcaccio S, Walsh DF, Shah KN, Owens BD, DeFroda SF. Suture anchor versus transosseous tunnel repair for inferior pole patellar fractures treated with partial patellectomy and tendon advancement: a biomechanical study. Orthop J Sports Med. 2021, 9:23259671211022245. 10.1177\/23259671211022245","journal-title":"Orthop J Sports Med"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1007\/BF02498719","article-title":"Fractures of the patella treated by operation","volume":"102","author":"B\u00f6stman O","year":"1983","unstructured":"B\u00f6stman O, Kiviluoto O, Santavirta S, Nirhamo J, Wilppula E. Fractures of the patella treated by operation. Arch Orthop Trauma Surg (1978). 1983, 102:78-81. 10.1007\/BF02498719","journal-title":"Arch Orthop Trauma Surg (1978)"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1177\/0363546506287489","article-title":"The use of suture anchors in repair of the ruptured patellar tendon: a biomechanical study","volume":"34","author":"Bushnell BD","year":"2006","unstructured":"Bushnell BD, Byram IR, Weinhold PS, Creighton RA. The use of suture anchors in repair of the ruptured patellar tendon: a biomechanical study. Am J Sports Med. 2006, 34:1492-9. 10.1177\/0363546506287489","journal-title":"Am J Sports Med"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.K.01549","article-title":"Complications following tension-band fixation of patellar fractures with cannulated screws compared with Kirschner wires","volume":"95","author":"Hoshino CM","year":"2013","unstructured":"Hoshino CM, Tran W, Tiberi JV, Black MH, Li BH, Gold SM, Navarro RA. Complications following tension-band fixation of patellar fractures with cannulated screws compared with Kirschner wires. J Bone Joint Surg Am. 2013, 95:653-9. 10.2106\/JBJS.K.01549","journal-title":"J Bone Joint Surg Am"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.1016\/j.jor.2023.04.006","article-title":"Comparison of all-suture anchors with metallic anchors in arthroscopic cuff repair: structural and functional properties and clinical suitability","volume":"39","author":"Piatti M","year":"2023","unstructured":"Piatti M, Gorla M, Alberio F, et al.. Comparison of all-suture anchors with metallic anchors in arthroscopic cuff repair: structural and functional properties and clinical suitability. J Orthop. 2023, 39:66-9. 10.1016\/j.jor.2023.04.006","journal-title":"J Orthop"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.1053\/j.oto.2013.05.005","article-title":"Double-row suture-bridging arthroscopic rotator cuff repair","volume":"23","author":"Denard PJ","year":"2013","unstructured":"Denard PJ, Burkhart SS. Double-row suture-bridging arthroscopic rotator cuff repair. Oper Tech Orthop. 2013, 23:84-90. 10.1053\/j.oto.2013.05.005","journal-title":"Oper Tech Orthop"},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.1177\/03635465020300040301","article-title":"Biomechanical comparison of patellar tendon repairs in a cadaver model: an evaluation of gap formation at the repair site with cyclic loading","volume":"30","author":"Ravalin RV","year":"2002","unstructured":"Ravalin RV, Mazzocca AD, Grady-Benson JC, Nissen CW, Adams DJ. Biomechanical comparison of patellar tendon repairs in a cadaver model: an evaluation of gap formation at the repair site with cyclic loading. Am J Sports Med. 2002, 30:469-73. 10.1177\/03635465020300040301","journal-title":"Am J Sports Med"},{"key":"ref18","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2012.11.008","article-title":"Transosseous-equivalent rotator cuff repair: a systematic review on the biomechanical importance of tying the medial row","volume":"29","author":"Mall NA","year":"2013","unstructured":"Mall NA, Lee AS, Chahal J, Van Thiel GS, Romeo AA, Verma NN, Cole BJ. Transosseous-equivalent rotator cuff repair: a systematic review on the biomechanical importance of tying the medial row. Arthroscopy. 2013, 29:377-86. 10.1016\/j.arthro.2012.11.008","journal-title":"Arthroscopy"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/476026-double-row-suture-anchor-fixation-for-inferior-pole-patella-fracture-a-novel-technique","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,21]],"date-time":"2026-03-21T17:47:48Z","timestamp":1774115268000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/476026-double-row-suture-anchor-fixation-for-inferior-pole-patella-fracture-a-novel-technique"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,21]]},"references-count":18,"URL":"https:\/\/doi.org\/10.7759\/cureus.105610","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2026,3,21]]}}}