{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,27]],"date-time":"2026-07-27T15:43:55Z","timestamp":1785167035320,"version":"3.55.0"},"reference-count":29,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,4,9]]},"DOI":"10.7759\/cureus.106726","type":"journal-article","created":{"date-parts":[[2026,4,9]],"date-time":"2026-04-09T16:08:10Z","timestamp":1775750890000},"source":"Crossref","is-referenced-by-count":1,"title":["Robotic Versus Conventional Primary Total Knee Arthroplasty: Achievement of Minimal Clinically Important Difference at One-Year Follow-Up"],"prefix":"10.7759","author":[{"given":"Adarsh","family":"Venugopal","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jai","family":"Thilak","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1007\/s11999-009-0834-6","article-title":"Future young patient demand for primary and revision joint replacement: national projections from 2010 to 2030","volume":"467","author":"Kurtz SM","year":"2009","unstructured":"Kurtz SM, Lau E, Ong K, Zhao K, Kelly M, Bozic KJ. Future young patient demand for primary and revision joint replacement: national projections from 2010 to 2030. Clin Orthop Relat Res. 2009, 467:2606-12. 10.1007\/s11999-009-0834-6","journal-title":"Clin Orthop Relat Res"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2022.10.011","article-title":"Are 20% of patients actually dissatisfied following total knee arthroplasty? A systematic review of the literature","volume":"38","author":"DeFrance MJ","year":"2023","unstructured":"DeFrance MJ, Scuderi GR. Are 20% of patients actually dissatisfied following total knee arthroplasty? A systematic review of the literature. J Arthroplasty. 2023, 38:594-9. 10.1016\/j.arth.2022.10.011","journal-title":"J Arthroplasty"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.96B11.34152","article-title":"Patient dissatisfaction following total knee replacement: a growing concern?","volume":"96-B","author":"Nam D","year":"2014","unstructured":"Nam D, Nunley RM, Barrack RL. Patient dissatisfaction following total knee replacement: a growing concern?. Bone Joint J. 2014, 96-B:96-100. 10.1302\/0301-620X.96B11.34152","journal-title":"Bone Joint J"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1302\/2058-5241.4.190022","article-title":"Robotic technology in total knee arthroplasty: a systematic review","volume":"4","author":"Kayani B","year":"2019","unstructured":"Kayani B, Konan S, Ayuob A, Onochie E, Al-Jabri T, Haddad FS. Robotic technology in total knee arthroplasty: a systematic review. EFORT Open Rev. 2019, 4:611-7. 10.1302\/2058-5241.4.190022","journal-title":"EFORT Open Rev"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2007.08.001","article-title":"Meta-analysis of alignment outcomes in computer-assisted total knee arthroplasty surgery","volume":"22","author":"Mason JB","year":"2007","unstructured":"Mason JB, Fehring TK, Estok R, Banel D, Fahrbach K. Meta-analysis of alignment outcomes in computer-assisted total knee arthroplasty surgery. J Arthroplasty. 2007, 22:1097-106. 10.1016\/j.arth.2007.08.001","journal-title":"J Arthroplasty"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.100B7.BJJ-2017-1449.R1","article-title":"Robotic-arm assisted total knee arthroplasty is associated with improved early functional recovery and reduced time to hospital discharge compared with conventional jig-based total knee arthroplasty: a prospective cohort study","volume":"100-B","author":"Kayani B","year":"2018","unstructured":"Kayani B, Konan S, Tahmassebi J, Pietrzak JR, Haddad FS. Robotic-arm assisted total knee arthroplasty is associated with improved early functional recovery and reduced time to hospital discharge compared with conventional jig-based total knee arthroplasty: a prospective cohort study. Bone Joint J. 2018, 100-B:930-7. 10.1302\/0301-620X.100B7.BJJ-2017-1449.R1","journal-title":"Bone Joint J"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.88B2.17220","article-title":"Hands-on robotic unicompartmental knee replacement: a prospective, randomised controlled study of the acrobot system","volume":"88","author":"Cobb J","year":"2006","unstructured":"Cobb J, Henckel J, Gomes P, et al.. Hands-on robotic unicompartmental knee replacement: a prospective, randomised controlled study of the acrobot system. J Bone Joint Surg Br. 2006, 88:188-97. 10.1302\/0301-620X.88B2.17220","journal-title":"J Bone Joint Surg Br"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2011.09.021","article-title":"Accuracy of dynamic tactile-guided unicompartmental knee arthroplasty","volume":"27","author":"Dunbar NJ","year":"2012","unstructured":"Dunbar NJ, Roche MW, Park BH, Branch SH, Conditt MA, Banks SA. Accuracy of dynamic tactile-guided unicompartmental knee arthroplasty. J Arthroplasty. 2012, 27:803-8.e1. 10.1016\/j.arth.2011.09.021","journal-title":"J Arthroplasty"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.H.01372","article-title":"Minimally invasive robotic-arm-guided unicompartmental knee arthroplasty","volume":"91 Suppl 1","author":"Conditt MA","year":"2009","unstructured":"Conditt MA, Roche MW. Minimally invasive robotic-arm-guided unicompartmental knee arthroplasty. J Bone Joint Surg Am. 2009, 91 Suppl 1:63-8. 10.2106\/JBJS.H.01372","journal-title":"J Bone Joint Surg Am"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1007\/s00167-011-1400-9","article-title":"Simultaneous bilateral total knee arthroplasty with robotic and conventional techniques: a prospective, randomized study","volume":"19","author":"Song EK","year":"2011","unstructured":"Song EK, Seon JK, Park SJ, Jung WB, Park HW, Lee GW. Simultaneous bilateral total knee arthroplasty with robotic and conventional techniques: a prospective, randomized study. Knee Surg Sports Traumatol Arthrosc. 2011, 19:1069-76. 10.1007\/s00167-011-1400-9","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1007\/s11999-012-2407-3","article-title":"Robotic-assisted TKA reduces postoperative alignment outliers and improves gap balance compared to conventional TKA","volume":"471","author":"Song EK","year":"2013","unstructured":"Song EK, Seon JK, Yim JH, Netravali NA, Bargar WL. Robotic-assisted TKA reduces postoperative alignment outliers and improves gap balance compared to conventional TKA. Clin Orthop Relat Res. 2013, 471:118-26. 10.1007\/s11999-012-2407-3","journal-title":"Clin Orthop Relat Res"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1016\/j.surge.2017.12.003","article-title":"Increased precision of coronal plane outcomes in robotic-assisted total knee arthroplasty: a\u00a0systematic review and meta-analysis","volume":"16","author":"Mannan A","year":"2018","unstructured":"Mannan A, Vun J, Lodge C, Eyre-Brook A, Jones S. Increased precision of coronal plane outcomes in robotic-assisted total knee arthroplasty: a\u00a0systematic review and meta-analysis. Surgeon. 2018, 16:237-44. 10.1016\/j.surge.2017.12.003","journal-title":"Surgeon"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1016\/j.spinee.2007.01.008","article-title":"Understanding the minimum clinically important difference: a review of concepts and methods","volume":"7","author":"Copay AG","year":"2007","unstructured":"Copay AG, Subach BR, Glassman SD, Polly DW Jr, Schuler TC. Understanding the minimum clinically important difference: a review of concepts and methods. Spine J. 2007, 7:541-6. 10.1016\/j.spinee.2007.01.008","journal-title":"Spine J"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1007\/s11999-016-4718-2","article-title":"Validation of the HOOS, JR: a short-form hip replacement survey","volume":"474","author":"Lyman S","year":"2016","unstructured":"Lyman S, Lee YY, Franklin PD, Li W, Mayman DJ, Padgett DE. Validation of the HOOS, JR: a short-form hip replacement survey. Clin Orthop Relat Res. 2016, 474:1472-82. 10.1007\/s11999-016-4718-2","journal-title":"Clin Orthop Relat Res"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.1007\/s11136-009-9496-9","article-title":"Development of physical and mental health summary scores from the patient-reported outcomes measurement information system (PROMIS) global items","volume":"18","author":"Hays RD","year":"2009","unstructured":"Hays RD, Bjorner JB, Revicki DA, Spritzer KL, Cella D. Development of physical and mental health summary scores from the patient-reported outcomes measurement information system (PROMIS) global items. Qual Life Res. 2009, 18:873-80. 10.1007\/s11136-009-9496-9","journal-title":"Qual Life Res"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.1055\/s-0038-1641729","article-title":"Robotic-arm assisted total knee arthroplasty demonstrated greater accuracy and precision to plan compared with manual techniques","volume":"32","author":"Hampp EL","year":"2019","unstructured":"Hampp EL, Chughtai M, Scholl LY, Sodhi N, Bhowmik-Stoker M, Jacofsky DJ, Mont MA. Robotic-arm assisted total knee arthroplasty demonstrated greater accuracy and precision to plan compared with manual techniques. J Knee Surg. 2019, 32:239-50. 10.1055\/s-0038-1641729","journal-title":"J Knee Surg"},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2021.01.041","article-title":"Minimizing surgical instrument burden increases operating room efficiency and reduces perioperative costs in total joint arthroplasty","volume":"36","author":"Lonner JH","year":"2021","unstructured":"Lonner JH, Goh GS, Sommer K, Niggeman G, Levicoff EA, Vernace JV, Good RP. Minimizing surgical instrument burden increases operating room efficiency and reduces perioperative costs in total joint arthroplasty. J Arthroplasty. 2021, 36:1857-63. 10.1016\/j.arth.2021.01.041","journal-title":"J Arthroplasty"},{"key":"ref18","doi-asserted-by":"publisher","DOI":"10.1186\/s43019-020-00038-3","article-title":"Minimal clinically important difference of commonly used patient-reported outcome measures in total knee arthroplasty: review of terminologies, methods and proposed values","volume":"32","author":"Maredupaka S","year":"2020","unstructured":"Maredupaka S, Meshram P, Chatte M, Kim WH, Kim TK. Minimal clinically important difference of commonly used patient-reported outcome measures in total knee arthroplasty: review of terminologies, methods and proposed values. Knee Surg Relat Res. 2020, 32:19. 10.1186\/s43019-020-00038-3","journal-title":"Knee Surg Relat Res"},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2021.02.038","article-title":"Minimal clinically important difference in robotic-assisted total knee arthroplasty versus standard manual total knee arthroplasty","volume":"36","author":"Shaw JH","year":"2021","unstructured":"Shaw JH, Lindsay-Rivera KG, Buckley PJ, Weir RM, Banka TR, Davis JJ. Minimal clinically important difference in robotic-assisted total knee arthroplasty versus standard manual total knee arthroplasty. J Arthroplasty. 2021, 36:S233-41. 10.1016\/j.arth.2021.02.038","journal-title":"J Arthroplasty"},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.1007\/s00264-022-05411-3","article-title":"Moving beyond radiographic alignment: applying the Wald principles in the adoption of robotic total knee arthroplasty","volume":"47","author":"Lonner JH","year":"2023","unstructured":"Lonner JH, Goh GS. Moving beyond radiographic alignment: applying the Wald principles in the adoption of robotic total knee arthroplasty. Int Orthop. 2023, 47:365-73. 10.1007\/s00264-022-05411-3","journal-title":"Int Orthop"},{"key":"ref21","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2021.11.021","article-title":"Total knee arthroplasty with robotic surgical assistance results in less physician stress and strain than conventional methods","volume":"37","author":"Haffar A","year":"2022","unstructured":"Haffar A, Krueger CA, Goh GS, Lonner JH. Total knee arthroplasty with robotic surgical assistance results in less physician stress and strain than conventional methods. J Arthroplasty. 2022, 37:S193-200. 10.1016\/j.arth.2021.11.021","journal-title":"J Arthroplasty"},{"key":"ref22","doi-asserted-by":"publisher","DOI":"10.1055\/s-0040-1721412","article-title":"Effect of manual versus robotic-assisted total knee arthroplasty on cervical spine static and dynamic postures","volume":"35","author":"Scholl LY","year":"2022","unstructured":"Scholl LY, Hampp EL, Alipit V, et al.. Effect of manual versus robotic-assisted total knee arthroplasty on cervical spine static and dynamic postures. J Knee Surg. 2022, 35:1010-8. 10.1055\/s-0040-1721412","journal-title":"J Knee Surg"},{"key":"ref23","doi-asserted-by":"publisher","DOI":"10.1097\/CORR.0000000000000916","article-title":"Does robotic-assisted TKA result in better outcome scores or long-term survivorship than conventional TKA? A randomized, controlled trial","volume":"478","author":"Kim YH","year":"2020","unstructured":"Kim YH, Yoon SH, Park JW. Does robotic-assisted TKA result in better outcome scores or long-term survivorship than conventional TKA? A randomized, controlled trial. Clin Orthop Relat Res. 2020, 478:266-75. 10.1097\/CORR.0000000000000916","journal-title":"Clin Orthop Relat Res"},{"key":"ref24","doi-asserted-by":"publisher","DOI":"10.1055\/s-0039-1684014","article-title":"Patient-reported functional and satisfaction outcomes after robotic-arm-assisted total knee arthroplasty: early results of a prospective multicenter investigation","volume":"33","author":"Khlopas A","year":"2020","unstructured":"Khlopas A, Sodhi N, Hozack WJ, et al.. Patient-reported functional and satisfaction outcomes after robotic-arm-assisted total knee arthroplasty: early results of a prospective multicenter investigation. J Knee Surg. 2020, 33:685-90. 10.1055\/s-0039-1684014","journal-title":"J Knee Surg"},{"key":"ref25","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2023.02.023","article-title":"Image-free robotic-assisted total knee arthroplasty results in quicker recovery but equivalent one-year outcomes compared to conventional total knee arthroplasty","volume":"38","author":"Khan IA","year":"2023","unstructured":"Khan IA, Vaile JR, DeSimone CA, et al.. Image-free robotic-assisted total knee arthroplasty results in quicker recovery but equivalent one-year outcomes compared to conventional total knee arthroplasty. J Arthroplasty. 2023, 38:S232-7. 10.1016\/j.arth.2023.02.023","journal-title":"J Arthroplasty"},{"key":"ref26","doi-asserted-by":"publisher","DOI":"10.1055\/s-0037-1607450","article-title":"Patient satisfaction outcomes after robotic arm-assisted total knee arthroplasty: a short-term evaluation","volume":"30","author":"Marchand RC","year":"2017","unstructured":"Marchand RC, Sodhi N, Khlopas A, Sultan AA, Harwin SF, Malkani AL, Mont MA. Patient satisfaction outcomes after robotic arm-assisted total knee arthroplasty: a short-term evaluation. J Knee Surg. 2017, 30:849-53. 10.1055\/s-0037-1607450","journal-title":"J Knee Surg"},{"key":"ref27","doi-asserted-by":"publisher","DOI":"10.1177\/15563316211028568","article-title":"Relative clinical outcomes comparing manual and robotic-assisted total knee arthroplasty at minimum 1-year follow-up","volume":"17","author":"Mitchell J","year":"2021","unstructured":"Mitchell J, Wang J, Bukowski B, Greiner J, Wolford B, Oyer M, Illgen RL 2nd. Relative clinical outcomes comparing manual and robotic-assisted total knee arthroplasty at minimum 1-year follow-up. HSS J. 2021, 17:267-73. 10.1177\/15563316211028568","journal-title":"HSS J"},{"key":"ref28","doi-asserted-by":"publisher","DOI":"10.1055\/s-0041-1731323","article-title":"Robotic arm-assisted versus manual total knee arthroplasty: a propensity score-matched analysis","volume":"36","author":"Samuel LT","year":"2023","unstructured":"Samuel LT, Karnuta JM, Banerjee A, et al.. Robotic arm-assisted versus manual total knee arthroplasty: a propensity score-matched analysis. J Knee Surg. 2023, 36:105-14. 10.1055\/s-0041-1731323","journal-title":"J Knee Surg"},{"key":"ref29","doi-asserted-by":"publisher","DOI":"10.1007\/s00167-016-4076-3","article-title":"Robotic-assisted total knee arthroplasty may lead to improvement in quality-of-life measures: a 2-year follow-up of a prospective randomized trial","volume":"25","author":"Liow MH","year":"2017","unstructured":"Liow MH, Goh GS, Wong MK, Chin PL, Tay DK, Yeo SJ. Robotic-assisted total knee arthroplasty may lead to improvement in quality-of-life measures: a 2-year follow-up of a prospective randomized trial. Knee Surg Sports Traumatol Arthrosc. 2017, 25:2942-51. 10.1007\/s00167-016-4076-3","journal-title":"Knee Surg Sports Traumatol Arthrosc"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/394334-robotic-versus-conventional-primary-total-knee-arthroplasty-achievement-of-minimal-clinically-important-difference-at-one-year-follow-up","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,9]],"date-time":"2026-04-09T16:08:11Z","timestamp":1775750891000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/394334-robotic-versus-conventional-primary-total-knee-arthroplasty-achievement-of-minimal-clinically-important-difference-at-one-year-follow-up"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,9]]},"references-count":29,"URL":"https:\/\/doi.org\/10.7759\/cureus.106726","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2026,4,9]]}}}