{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T10:57:50Z","timestamp":1777633070658,"version":"3.51.4"},"reference-count":53,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,4,28]]},"DOI":"10.7759\/cureus.107925","type":"journal-article","created":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T04:24:41Z","timestamp":1777436681000},"source":"Crossref","is-referenced-by-count":0,"title":["Stereotactic Body Radiotherapy (SBRT) for Liver Tumors: A Systematic Review on the Choice of Photon Energy and Linac Flattened\/Unflattened Beams"],"prefix":"10.7759","author":[{"given":"Kesava Ramgopal","family":"Adavikolanu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chandramouli","family":"R","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Soorej Balan","family":"Kaliyath","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Thirumal","family":"M","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Abhishek  R","family":"K S","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"NagaSai Divya","family":"Kari","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pragnahitha","family":"Neerudu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ambedkar","family":"Yadala","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Madhuri","family":"Palla","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ajay Kumar","family":"Kondeti","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1200\/JCO.2006.09.7469","article-title":"Stereotactic body radiation therapy in multiple organ sites","volume":"25","author":"Timmerman RD","year":"2007","unstructured":"Timmerman RD, Kavanagh BD, Cho LC, Papiez L, Xing L. Stereotactic body radiation therapy in multiple organ sites. J Clin Oncol. 2007, 25:947-52. 10.1200\/JCO.2006.09.7469","journal-title":"J Clin Oncol"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.3109\/02841869409121782","article-title":"Stereotactic radiotherapy of malignancies in the abdomen: methodological aspects","volume":"33","author":"Lax I","year":"1994","unstructured":"Lax I, Blomgren H, N\u00e4slund I, Svanstr\u00f6m R. Stereotactic radiotherapy of malignancies in the abdomen: methodological aspects. Acta Oncol. 1994, 33:677-83. 10.3109\/02841869409121782","journal-title":"Acta Oncol"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1118\/1.3438081","article-title":"Stereotactic body radiation therapy: the report of AAPM Task Group 101","volume":"37","author":"Benedict SH","year":"2010","unstructured":"Benedict SH, Yenice KM, Followill D, et al.. Stereotactic body radiation therapy: the report of AAPM Task Group 101. Med Phys. 2010, 37:4078-101. 10.1118\/1.3438081","journal-title":"Med Phys"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2009.09.042","article-title":"American Society for Therapeutic Radiology and Oncology (ASTRO) and American College of Radiology (ACR) practice guideline for the performance of stereotactic body radiation therapy","volume":"76","author":"Potters L","year":"2010","unstructured":"Potters L, Kavanagh B, Galvin JM, et al.. American Society for Therapeutic Radiology and Oncology (ASTRO) and American College of Radiology (ACR) practice guideline for the performance of stereotactic body radiation therapy. Int J Radiat Oncol Biol Phys. 2010, 76:326-32. 10.1016\/j.ijrobp.2009.09.042","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1007\/s00066-020-01603-1","article-title":"Definition and quality requirements for stereotactic radiotherapy: consensus statement from the DEGRO\/DGMP Working Group Stereotactic Radiotherapy and Radiosurgery","volume":"196","author":"Guckenberger M","year":"2020","unstructured":"Guckenberger M, Baus WW, Blanck O, et al.. Definition and quality requirements for stereotactic radiotherapy: consensus statement from the DEGRO\/DGMP Working Group Stereotactic Radiotherapy and Radiosurgery. Strahlenther Onkol. 2020, 196:417-20. 10.1007\/s00066-020-01603-1","journal-title":"Strahlenther Onkol"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1007\/s00432-015-1929-y","article-title":"The challenge of inoperable hepatocellular carcinoma (HCC): results of a single-institutional experience on stereotactic body radiation therapy (SBRT)","volume":"141","author":"Scorsetti M","year":"2015","unstructured":"Scorsetti M, Comito T, Cozzi L, et al.. The challenge of inoperable hepatocellular carcinoma (HCC): results of a single-institutional experience on stereotactic body radiation therapy (SBRT). J Cancer Res Clin Oncol. 2015, 141:1301-9. 10.1007\/s00432-015-1929-y","journal-title":"J Cancer Res Clin Oncol"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1200\/JCO.2012.44.1659","article-title":"Sequential phase I and II trials of stereotactic body radiotherapy for locally advanced hepatocellular carcinoma","volume":"31","author":"Bujold A","year":"2013","unstructured":"Bujold A, Massey CA, Kim JJ, et al.. Sequential phase I and II trials of stereotactic body radiotherapy for locally advanced hepatocellular carcinoma. J Clin Oncol. 2013, 31:1631-9. 10.1200\/JCO.2012.44.1659","journal-title":"J Clin Oncol"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1200\/JCO.2008.19.6329","article-title":"Multi-institutional phase I\/II trial of stereotactic body radiation therapy for liver metastases","volume":"27","author":"Rusthoven KE","year":"2009","unstructured":"Rusthoven KE, Kavanagh BD, Cardenes H, et al.. Multi-institutional phase I\/II trial of stereotactic body radiation therapy for liver metastases. J Clin Oncol. 2009, 27:1572-8. 10.1200\/JCO.2008.19.6329","journal-title":"J Clin Oncol"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.3978\/j.issn.2078-6891.2014.039","article-title":"Stereotactic body radiation therapy for liver metastases","volume":"5","author":"Scorsetti M","year":"2014","unstructured":"Scorsetti M, Clerici E, Comito T. Stereotactic body radiation therapy for liver metastases. J Gastrointest Oncol. 2014, 5:190-7. 10.3978\/j.issn.2078-6891.2014.039","journal-title":"J Gastrointest Oncol"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1634\/theoncologist.2012-0092","article-title":"Review and uses of stereotactic body radiation therapy for oligometastases","volume":"17","author":"Alongi F","year":"2012","unstructured":"Alongi F, Arcangeli S, Filippi AR, Ricardi U, Scorsetti M. Review and uses of stereotactic body radiation therapy for oligometastases. Oncologist. 2012, 17:1100-7. 10.1634\/theoncologist.2012-0092","journal-title":"Oncologist"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.3390\/cancers17071088","article-title":"Image-guided stereotactic body radiotherapy (SBRT) with enhanced visualization of tumor and hepatic parenchyma in patients with primary and metastatic liver malignancies","volume":"17","author":"Kirichenko AV","year":"2025","unstructured":"Kirichenko AV, Lee D, Wagner P, et al.. Image-guided stereotactic body radiotherapy (SBRT) with enhanced visualization of tumor and hepatic parenchyma in patients with primary and metastatic liver malignancies. Cancers (Basel). 2025, 17:1088. 10.3390\/cancers17071088","journal-title":"Cancers (Basel)"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1016\/j.radonc.2013.09.014","article-title":"Flattening-filter-free intensity modulated breath-hold image-guided SABR (Stereotactic ABlative Radiotherapy) can be applied in a 15-min treatment slot","volume":"109","author":"Boda-Heggemann J","year":"2013","unstructured":"Boda-Heggemann J, Mai S, Fleckenstein J, et al.. Flattening-filter-free intensity modulated breath-hold image-guided SABR (Stereotactic ABlative Radiotherapy) can be applied in a 15-min treatment slot. Radiother Oncol. 2013, 109:505-9. 10.1016\/j.radonc.2013.09.014","journal-title":"Radiother Oncol"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1120\/jacmp.v16i3.5219","article-title":"Flattening filter-free accelerators: a report from the AAPM Therapy Emerging Technology Assessment Work Group","volume":"16","author":"Xiao Y","year":"2015","unstructured":"Xiao Y, Kry SF, Popple R, et al.. Flattening filter-free accelerators: a report from the AAPM Therapy Emerging Technology Assessment Work Group. J Appl Clin Med Phys. 2015, 16:5219. 10.1120\/jacmp.v16i3.5219","journal-title":"J Appl Clin Med Phys"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1515\/raon-2016-0012","article-title":"The dosimetric significance of using 10 MV photons for volumetric modulated arc therapy for post-prostatectomy irradiation of the prostate bed","volume":"50","author":"Kleiner H","year":"2016","unstructured":"Kleiner H, Podgorsak MB. The dosimetric significance of using 10 MV photons for volumetric modulated arc therapy for post-prostatectomy irradiation of the prostate bed. Radiol Oncol. 2016, 50:232-7. 10.1515\/raon-2016-0012","journal-title":"Radiol Oncol"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.1120\/jacmp.v17i1.5677","article-title":"Comparison of volumetric-modulated arc therapy and dynamic conformal arc treatment planning for cranial stereotactic radiosurgery","volume":"17","author":"Molinier J","year":"2016","unstructured":"Molinier J, Kerr C, Simeon S, Ailleres N, Charissoux M, Azria D, Fenoglietto P. Comparison of volumetric-modulated arc therapy and dynamic conformal arc treatment planning for cranial stereotactic radiosurgery. J Appl Clin Med Phys. 2016, 17:92-101. 10.1120\/jacmp.v17i1.5677","journal-title":"J Appl Clin Med Phys"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.1186\/s13014-023-02392-4","article-title":"Stereotactic body radiotherapy for early-stage lung cancer: a systematic review on the choice of photon energy and linac flattened\/unflattened beams","volume":"19","author":"Gill A","year":"2024","unstructured":"Gill A, Hirst AL, Rowshanfarzad P, Gill S, Bucknell N, Dass J, Sabet M. Stereotactic body radiotherapy for early-stage lung cancer: a systematic review on the choice of photon energy and linac flattened\/unflattened beams. Radiat Oncol. 2024, 19:1. 10.1186\/s13014-023-02392-4","journal-title":"Radiat Oncol"},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.21037\/atm.2018.06.40","article-title":"Stereotactic body radiation therapy for lung, spine and oligometastatic disease: current evidence and future directions","volume":"6","author":"Dunne EM","year":"2018","unstructured":"Dunne EM, Fraser IM, Liu M. Stereotactic body radiation therapy for lung, spine and oligometastatic disease: current evidence and future directions. Ann Transl Med. 2018, 6:283. 10.21037\/atm.2018.06.40","journal-title":"Ann Transl Med"},{"key":"ref18","doi-asserted-by":"publisher","DOI":"10.3892\/ol.2025.15161","article-title":"Application of respiratory motion management technology for patients with lung cancer treated with stereotactic body radiotherapy (Review)","volume":"30","author":"Shao K","year":"2025","unstructured":"Shao K, Chen W, Xu Y, Yang S. Application of respiratory motion management technology for patients with lung cancer treated with stereotactic body radiotherapy (Review). Oncol Lett. 2025, 30:415. 10.3892\/ol.2025.15161","journal-title":"Oncol Lett"},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.3390\/cancers16213692","article-title":"The role of CT and MR imaging in stereotactic body radiotherapy of the spine: from patient selection and treatment planning to post-treatment monitoring","volume":"16","author":"Azadbakht J","year":"2024","unstructured":"Azadbakht J, Condos A, Haynor D, et al.. The role of CT and MR imaging in stereotactic body radiotherapy of the spine: from patient selection and treatment planning to post-treatment monitoring. Cancers (Basel). 2024, 16:3692. 10.3390\/cancers16213692","journal-title":"Cancers (Basel)"},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.1016\/j.rpor.2014.10.002","article-title":"Liver metastases and SBRT: a new paradigm?","volume":"20","author":"Comito T","year":"2015","unstructured":"Comito T, Clerici E, Tozzi A, D'Agostino G. Liver metastases and SBRT: a new paradigm?. Rep Pract Oncol Radiother. 2015, 20:464-71. 10.1016\/j.rpor.2014.10.002","journal-title":"Rep Pract Oncol Radiother"},{"key":"ref21","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pmed.1000097","article-title":"Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement","volume":"6","author":"Moher D","year":"2009","unstructured":"Moher D, Liberati A, Tetzlaff J, Altman DG. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. PLoS Med. 2009, 6:e1000097. 10.1371\/journal.pmed.1000097","journal-title":"PLoS Med"},{"key":"ref22","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.l4898","article-title":"RoB 2: a revised tool for assessing risk of bias in randomised trials","volume":"28","author":"Sterne JAC","year":"2019","unstructured":"Sterne JAC, Savovi\u0107 J, Page MJ, et al.. RoB 2: a revised tool for assessing risk of bias in randomised trials. BMJ. 2019, 28:4898. 10.1136\/bmj.l4898","journal-title":"BMJ"},{"key":"ref23","unstructured":"The Newcastle-Ottawa Scale (NOS) for assessing the quality of nonrandomized studies in meta-analyses. (2000). Accessed. February 24, 2026: http:\/\/www.ohri.ca\/programs\/clinical_epidemiology\/oxford.asp."},{"key":"ref24","doi-asserted-by":"publisher","DOI":"10.1136\/bmj-2023-076754","article-title":"ROB-ME: a tool for assessing risk of bias due to missing evidence in systematic reviews with meta-analysis","volume":"383","author":"Page MJ","year":"2023","unstructured":"Page MJ, Sterne JA, Boutron I, et al.. ROB-ME: a tool for assessing risk of bias due to missing evidence in systematic reviews with meta-analysis. BMJ. 2023, 383:e076754. 10.1136\/bmj-2023-076754","journal-title":"BMJ"},{"key":"ref25","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.39490.551019.BE","article-title":"What is \"quality of evidence\" and why is it important to clinicians?","volume":"336","author":"Guyatt GH","year":"2008","unstructured":"Guyatt GH, Oxman AD, Kunz R, Vist GE, Falck-Ytter Y, Sch\u00fcnemann HJ. What is \"quality of evidence\" and why is it important to clinicians?. BMJ. 2008, 336:995-8. 10.1136\/bmj.39490.551019.BE","journal-title":"BMJ"},{"key":"ref26","article-title":"Effect of minimum segment width on SRT\/SBRT volumetric arc therapy plans for flattening filter free beams","volume":"10","author":"Kaur SP","year":"2025","unstructured":"Kaur SP, Shivanjli, Oinam AS, et al.. Effect of minimum segment width on SRT\/SBRT volumetric arc therapy plans for flattening filter free beams. Asian Pac J Canc Biol. 2025, 10:309-13.","journal-title":"Asian Pac J Canc Biol"},{"key":"ref27","doi-asserted-by":"publisher","DOI":"10.1007\/s11547-024-01788-w","article-title":"High dose proton and photon-based radiation therapy for 213 liver lesions: a multi-institutional dosimetric comparison with a clinical perspective","volume":"129","author":"Bon\u00f9 ML","year":"2024","unstructured":"Bon\u00f9 ML, Nicosia L, Turkaj A, et al.. High dose proton and photon-based radiation therapy for 213 liver lesions: a multi-institutional dosimetric comparison with a clinical perspective. Radiol Med. 2024, 129:497-506. 10.1007\/s11547-024-01788-w","journal-title":"Radiol Med"},{"key":"ref28","doi-asserted-by":"publisher","DOI":"10.1007\/s00066-023-02181-8","article-title":"Stereotactic body radiotherapy with volumetric intensity-modulated arc therapy and flattening filter-free beams: dosimetric considerations","volume":"200","author":"Brekner MC","year":"2024","unstructured":"Brekner MC, Imhoff D, R\u00f6del C, et al.. Stereotactic body radiotherapy with volumetric intensity-modulated arc therapy and flattening filter-free beams: dosimetric considerations. Strahlenther Onkol. 2024, 200:346-357. 10.1007\/s00066-023-02181-8","journal-title":"Strahlenther Onkol"},{"key":"ref29","doi-asserted-by":"publisher","DOI":"10.22038\/IJMP.2022.63812.2090","article-title":"The dosimetric comparison of different SBRT techniques for treatment of liver cancer using flattened and flattening filter free beam","volume":"19","author":"Suresh T","year":"2022","unstructured":"Suresh T, Madeswaran S. The dosimetric comparison of different SBRT techniques for treatment of liver cancer using flattened and flattening filter free beam. Iran J Med Phys. 2022, 19:371-82. 10.22038\/IJMP.2022.63812.2090","journal-title":"Iran J Med Phys"},{"key":"ref30","doi-asserted-by":"publisher","DOI":"10.1111\/jgh.15011","article-title":"Clinical outcomes of stereotactic body radiation therapy for small hepatocellular carcinoma","volume":"35","author":"Park S","year":"2020","unstructured":"Park S, Jung J, Cho B, et al.. Clinical outcomes of stereotactic body radiation therapy for small hepatocellular carcinoma. J Gastroenterol Hepatol. 2020, 35:1953-1959. 10.1111\/jgh.15011","journal-title":"J Gastroenterol Hepatol"},{"key":"ref31","doi-asserted-by":"publisher","DOI":"10.3389\/fonc.2020.01170","article-title":"Which is better for liver SBRT: dosimetric comparison between DCAT and VMAT for liver tumors","volume":"10","author":"Moon YM","year":"2020","unstructured":"Moon YM, Jeon W, Yu T, Bae SI, Kim JY, Kang JK, Choi CW. Which is better for liver SBRT: dosimetric comparison between DCAT and VMAT for liver tumors. Front Oncol. 2020, 10:1170. 10.3389\/fonc.2020.01170","journal-title":"Front Oncol"},{"key":"ref32","doi-asserted-by":"publisher","DOI":"10.1016\/j.rpor.2020.04.017","article-title":"Dosimetric comparison of dynamic conformal arc integrated with segment shape optimization and variable dose rate versus volumetric modulated arc therapy for liver SBRT","volume":"25","author":"Thaper D","year":"2020","unstructured":"Thaper D, Kamal R, Singh G, et al.. Dosimetric comparison of dynamic conformal arc integrated with segment shape optimization and variable dose rate versus volumetric modulated arc therapy for liver SBRT. Rep Pract Oncol Radiother. 2020, 25:667-677. 10.1016\/j.rpor.2020.04.017","journal-title":"Rep Pract Oncol Radiother"},{"key":"ref33","article-title":"A dosimetric comparison between volumetric-modulated arc therapy and dynamic conformal arc therapy in SBRT","volume":"24","author":"Stathakis S","year":"2019","unstructured":"Stathakis S, Narayanasamy G, Licon AL, et al.. A dosimetric comparison between volumetric-modulated arc therapy and dynamic conformal arc therapy in SBRT. J BUON. 2019, 24:838-843.","journal-title":"J BUON"},{"key":"ref34","doi-asserted-by":"publisher","DOI":"10.1017\/s146039691800064x","article-title":"Dosimetric comparison of flattened and flattening filter-free beams for liver stereotactic body irradiation in deep inspiration breath hold, and free breathing conditions","volume":"18","author":"Munirathinam N","year":"2019","unstructured":"Munirathinam N, Pawaskar PN. Dosimetric comparison of flattened and flattening filter-free beams for liver stereotactic body irradiation in deep inspiration breath hold, and free breathing conditions. J Radiother Pract [Internet. 2019, 18:169-10. 10.1017\/s146039691800064x","journal-title":"J Radiother Pract [Internet"},{"key":"ref35","doi-asserted-by":"publisher","DOI":"10.1016\/j.meddos.2017.06.002","article-title":"Identification of the suitable leaf margin for liver stereotactic body radiotherapy with flattening filter-free beams","volume":"42","author":"Ogata T","year":"2017","unstructured":"Ogata T, Nishimura H, Mayahara H, Uehara K, Okayama T. Identification of the suitable leaf margin for liver stereotactic body radiotherapy with flattening filter-free beams. Med Dosim. 2017, 42:268-72. 10.1016\/j.meddos.2017.06.002","journal-title":"Med Dosim"},{"key":"ref36","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejmp.2016.10.007","article-title":"Dosimetric comparison of flattened and unflattened beams for stereotactic body radiation therapy: Impact of the size of the PTV on dynamic conformal arc and volumetric modulated arc therapy","volume":"32","author":"Vieillevigne L","year":"2016","unstructured":"Vieillevigne L, Bessieres S, Ouali M, Lanaspeze C. Dosimetric comparison of flattened and unflattened beams for stereotactic body radiation therapy: Impact of the size of the PTV on dynamic conformal arc and volumetric modulated arc therapy. Phys Med. 2016, 32:1405-14. 10.1016\/j.ejmp.2016.10.007","journal-title":"Phys Med"},{"key":"ref37","doi-asserted-by":"publisher","DOI":"10.17485\/ijst\/2016\/v9i20\/94679","article-title":"Evaluation on radiation treatment planning according to use of flattening filter (FF) or flattening filter-free (FFF) in high-energy X-ray equipment","volume":"9","author":"Kim GJ","year":"2016","unstructured":"Kim GJ, Choi JK, Hong DH, Kim HG, Beak GM. Evaluation on radiation treatment planning according to use of flattening filter (FF) or flattening filter-free (FFF) in high-energy X-ray equipment. Indian J Sci Technol. 2016, 9:1-5. 10.17485\/ijst\/2016\/v9i20\/94679","journal-title":"Indian J Sci Technol"},{"key":"ref38","doi-asserted-by":"publisher","DOI":"10.1118\/1.4939259","article-title":"Dosimetric and delivery efficiency investigation for treating hepatic lesions with a MLC-equipped robotic radiosurgery-radiotherapy combined system","volume":"43","author":"Jin L","year":"2016","unstructured":"Jin L, Price RA, Wang L, Meyer J, Fan JJ, Ma CM. Dosimetric and delivery efficiency investigation for treating hepatic lesions with a MLC-equipped robotic radiosurgery-radiotherapy combined system. Med Phys. 2016, 43:727-33. 10.1118\/1.4939259","journal-title":"Med Phys"},{"key":"ref39","doi-asserted-by":"publisher","DOI":"10.3109\/0284186X.2015.1009637","article-title":"Normal liver sparing by proton beam therapy for hepatocellular carcinoma: Comparison with helical intensity modulated radiotherapy and volumetric modulated arc therapy","volume":"54","author":"Kim JY","year":"2015","unstructured":"Kim JY, Lim YK, Kim TH, et al.. Normal liver sparing by proton beam therapy for hepatocellular carcinoma: Comparison with helical intensity modulated radiotherapy and volumetric modulated arc therapy. Acta Oncol. 2015, 54:1827-32. 10.3109\/0284186X.2015.1009637","journal-title":"Acta Oncol"},{"key":"ref40","doi-asserted-by":"publisher","DOI":"10.1186\/s13014-014-0317-0","article-title":"Safety of high-dose-rate stereotactic body radiotherapy","volume":"10","author":"Stieb S","year":"2015","unstructured":"Stieb S, Lang S, Linsenmeier C, Graydon S, Riesterer O. Safety of high-dose-rate stereotactic body radiotherapy. Radiat Oncol. 2015, 10:27. 10.1186\/s13014-014-0317-0","journal-title":"Radiat Oncol"},{"key":"ref41","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejmp.2015.09.009","article-title":"Multicentre treatment planning inter-comparison in a national context: the liver stereotactic ablative radiotherapy case","volume":"32","author":"Esposito M","year":"2016","unstructured":"Esposito M, Maggi G, Marino C, et al.. Multicentre treatment planning inter-comparison in a national context: the liver stereotactic ablative radiotherapy case. Phys Med. 2016, 32:277-83. 10.1016\/j.ejmp.2015.09.009","journal-title":"Phys Med"},{"key":"ref42","doi-asserted-by":"publisher","DOI":"10.1016\/j.prro.2015.01.004","article-title":"Clinical decision tool for optimal delivery of liver stereotactic body radiation therapy: Photons versus protons","volume":"5","author":"Gandhi SJ","year":"2015","unstructured":"Gandhi SJ, Liang X, Ding X, et al.. Clinical decision tool for optimal delivery of liver stereotactic body radiation therapy: Photons versus protons. Pract Radiat Oncol. 2015, 5:209-18. 10.1016\/j.prro.2015.01.004","journal-title":"Pract Radiat Oncol"},{"key":"ref43","doi-asserted-by":"publisher","DOI":"10.1186\/1748-717X-7-16","article-title":"Stereotactic body radiation therapy for liver tumours using flattening filter free beam: dosimetric and technical considerations","volume":"7","author":"Mancosu P","year":"2012","unstructured":"Mancosu P, Castiglioni S, Reggiori G, et al.. Stereotactic body radiation therapy for liver tumours using flattening filter free beam: dosimetric and technical considerations. Radiat Oncol. 2012, 7:16. 10.1186\/1748-717X-7-16","journal-title":"Radiat Oncol"},{"key":"ref44","doi-asserted-by":"publisher","DOI":"10.1120\/jacmp.v14i3.4126","article-title":"Flattening filter-free linac improves treatment delivery efficiency in stereotactic body radiation therapy","volume":"14","author":"Prendergast BM","year":"2013","unstructured":"Prendergast BM, Fiveash JB, Popple RA, et al.. Flattening filter-free linac improves treatment delivery efficiency in stereotactic body radiation therapy. J Appl Clin Med Phys. 2013, 14:4126. 10.1120\/jacmp.v14i3.4126","journal-title":"J Appl Clin Med Phys"},{"key":"ref45","doi-asserted-by":"publisher","DOI":"10.1118\/1.3679858","article-title":"Can volumetric modulated arc therapy with flattening filter free beams play a role in stereotactic body radiotherapy for liver lesions? A volume-based analysis","volume":"39","author":"Reggiori G","year":"2012","unstructured":"Reggiori G, Mancosu P, Castiglioni S, et al.. Can volumetric modulated arc therapy with flattening filter free beams play a role in stereotactic body radiotherapy for liver lesions? A volume-based analysis. Med Phys. 2012, 39:1112-8. 10.1118\/1.3679858","journal-title":"Med Phys"},{"key":"ref46","doi-asserted-by":"publisher","DOI":"10.1016\/j.radonc.2012.12.012","article-title":"Clinical application of flattening filter free beams for extracranial stereotactic radiotherapy","volume":"106","author":"Lang S","year":"2013","unstructured":"Lang S, Shrestha B, Graydon S, et al.. Clinical application of flattening filter free beams for extracranial stereotactic radiotherapy. Radiother Oncol. 2013, 106:255-9. 10.1016\/j.radonc.2012.12.012","journal-title":"Radiother Oncol"},{"key":"ref47","doi-asserted-by":"publisher","DOI":"10.1186\/1748-717X-6-113","article-title":"Feasibility and early clinical assessment of flattening filter free (FFF) based stereotactic body radiotherapy (SBRT) treatments","volume":"6","author":"Scorsetti M","year":"2011","unstructured":"Scorsetti M, Alongi F, Castiglioni S, et al.. Feasibility and early clinical assessment of flattening filter free (FFF) based stereotactic body radiotherapy (SBRT) treatments. Radiat Oncol. 2011, 6:113. 10.1186\/1748-717X-6-113","journal-title":"Radiat Oncol"},{"key":"ref48","doi-asserted-by":"publisher","DOI":"10.3109\/0284186X.2011.590526","article-title":"Normal liver tissue sparing by intensity-modulated proton stereotactic body radiotherapy for solitary liver tumours","volume":"50","author":"Petersen JB","year":"2011","unstructured":"Petersen JB, Lassen Y, Hansen AT, Muren LP, Grau C, H\u00f8yer M. Normal liver tissue sparing by intensity-modulated proton stereotactic body radiotherapy for solitary liver tumours. Acta Oncol. 2011, 50:823-8. 10.3109\/0284186X.2011.590526","journal-title":"Acta Oncol"},{"key":"ref49","doi-asserted-by":"publisher","DOI":"10.4103\/0971-6203.181636","article-title":"Dosimetric differences in flattened and flattening filter-free beam treatment plans","volume":"41","author":"Yan Y","year":"2016","unstructured":"Yan Y, Yadav P, Bassetti M, Du K, Saenz D, Harari P, Paliwal BR. Dosimetric differences in flattened and flattening filter-free beam treatment plans. J Med Phys. 2016, 41:92-9. 10.4103\/0971-6203.181636","journal-title":"J Med Phys"},{"key":"ref50","doi-asserted-by":"publisher","DOI":"10.1016\/j.ctro.2025.100947","article-title":"A dosimetric comparison of different radiotherapy modalities for non-resected oligometastatic liver disease","volume":"52","author":"Dejonckheere CS","year":"2025","unstructured":"Dejonckheere CS, Bilski M, Nour Y, et al.. A dosimetric comparison of different radiotherapy modalities for non-resected oligometastatic liver disease. Clin Transl Radiat Oncol. 2025, 52:100947. 10.1016\/j.ctro.2025.100947","journal-title":"Clin Transl Radiat Oncol"},{"key":"ref51","doi-asserted-by":"publisher","DOI":"10.1016\/j.rpor.2019.01.005","article-title":"Dosimetric impact of statistical uncertainty on Monte Carlo dose calculation algorithm in volumetric modulated arc therapy using Monaco TPS for three different clinical cases","volume":"24","author":"Palanisamy M","year":"2019","unstructured":"Palanisamy M, David K, Durai M, Bhalla N, Puri A. Dosimetric impact of statistical uncertainty on Monte Carlo dose calculation algorithm in volumetric modulated arc therapy using Monaco TPS for three different clinical cases. Rep Pract Oncol Radiother. 2019, 24:188-99. 10.1016\/j.rpor.2019.01.005","journal-title":"Rep Pract Oncol Radiother"},{"key":"ref52","doi-asserted-by":"publisher","DOI":"10.1111\/1754-9485.12583","article-title":"Efficacy of flattening-filter-free beam in stereotactic body radiation therapy planning and treatment: a systematic review with meta-analysis","volume":"61","author":"Dang TM","year":"2017","unstructured":"Dang TM, Peters MJ, Hickey B, Semciw A. Efficacy of flattening-filter-free beam in stereotactic body radiation therapy planning and treatment: a systematic review with meta-analysis. J Med Imaging Radiat Oncol. 2017, 61:379-87. 10.1111\/1754-9485.12583","journal-title":"J Med Imaging Radiat Oncol"},{"key":"ref53","doi-asserted-by":"publisher","DOI":"10.1017\/s1460396920000576","article-title":"Using FFF beams to improve the therapeutic ratio of lung SBRT","volume":"20","author":"Vassiliev ON","year":"2021","unstructured":"Vassiliev ON, Peterson CB, Chang JY, Mohan R. Using FFF beams to improve the therapeutic ratio of lung SBRT. J Radiother Pract. 2021, 20:419-25. 10.1017\/s1460396920000576","journal-title":"J Radiother Pract"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/483494-stereotactic-body-radiotherapy-sbrt-for-liver-tumors-a-systematic-review-on-the-choice-of-photon-energy-and-linac-flattenedunflattened-beams","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T04:24:49Z","timestamp":1777436689000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/483494-stereotactic-body-radiotherapy-sbrt-for-liver-tumors-a-systematic-review-on-the-choice-of-photon-energy-and-linac-flattenedunflattened-beams"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,28]]},"references-count":53,"URL":"https:\/\/doi.org\/10.7759\/cureus.107925","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2026,4,28]]}}}