{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,23]],"date-time":"2026-05-23T17:04:22Z","timestamp":1779555862741,"version":"3.53.1"},"reference-count":23,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,5,23]]},"DOI":"10.7759\/cureus.109506","type":"journal-article","created":{"date-parts":[[2026,5,23]],"date-time":"2026-05-23T16:12:31Z","timestamp":1779552751000},"source":"Crossref","is-referenced-by-count":0,"title":["Baseline Perfusion Index as a Predictor of Post-spinal Hypotension in Elective Caesarean Section: A Prospective Observational Study"],"prefix":"10.7759","author":[{"given":"Kazi","family":"Samsuzzaman","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Prithviraj","family":"Chakraverty","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Subhashis","family":"Saha","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anuradha","family":"Mitra","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Madhumita","family":"Bhakta","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-199702000-00002","article-title":"Anesthesia-related deaths during obstetric delivery in the United States, 1979-1990","volume":"86","author":"Hawkins JL","year":"1997","unstructured":"Hawkins JL, Koonin LM, Palmer SK, Gibbs CP. Anesthesia-related deaths during obstetric delivery in the United States, 1979-1990. Anesthesiology. 1997, 86:277-84. 10.1097\/00000542-199702000-00002","journal-title":"Anesthesiology"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1399-6576.2010.02239.x","article-title":"Definitions of hypotension after spinal anaesthesia for caesarean section: literature search and application to parturients","volume":"54","author":"Kl\u00f6hr S","year":"2010","unstructured":"Kl\u00f6hr S, Roth R, Hofmann T, Rossaint R, Heesen M. Definitions of hypotension after spinal anaesthesia for caesarean section: literature search and application to parturients. Acta Anaesthesiol Scand. 2010, 54:909-21. 10.1111\/j.1399-6576.2010.02239.x","journal-title":"Acta Anaesthesiol Scand"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-199206000-00006","article-title":"Incidence and risk factors for side effects of spinal anesthesia","volume":"76","author":"Carpenter RL","year":"1992","unstructured":"Carpenter RL, Caplan RA, Brown DL, Stephenson C, Wu R. Incidence and risk factors for side effects of spinal anesthesia. Anesthesiology. 1992, 76:906-16. 10.1097\/00000542-199206000-00006","journal-title":"Anesthesiology"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1152\/ajpheart.1989.256.4.H1060","article-title":"Serial study of factors influencing changes in cardiac output during human pregnancy","volume":"256","author":"Robson SC","year":"1989","unstructured":"Robson SC, Hunter S, Boys RJ, Dunlop W. Serial study of factors influencing changes in cardiac output during human pregnancy. Am J Physiol. 1989, 256:H1060-5. 10.1152\/ajpheart.1989.256.4.H1060","journal-title":"Am J Physiol"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-198201000-00019","article-title":"Method of ephedrine administration and nausea and hypotension during spinal anesthesia for cesarean section","volume":"56","author":"Datta S","year":"1982","unstructured":"Datta S, Alper MH, Ostheimer GW, Weiss JB. Method of ephedrine administration and nausea and hypotension during spinal anesthesia for cesarean section. Anesthesiology. 1982, 56:68-70. 10.1097\/00000542-198201000-00019","journal-title":"Anesthesiology"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1097\/ACO.0b013e328337ffc6","article-title":"Prevention of maternal hypotension after regional anaesthesia for caesarean section","volume":"23","author":"Ngan Kee WD","year":"2010","unstructured":"Ngan Kee WD. Prevention of maternal hypotension after regional anaesthesia for caesarean section. Curr Opin Anaesthesiol. 2010, 23:304-9. 10.1097\/ACO.0b013e328337ffc6","journal-title":"Curr Opin Anaesthesiol"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.1982.tb01278.x","article-title":"Spinal anaesthesia for caesarean section. The influence of hypotension on neonatal outcome","volume":"37","author":"Corke BC","year":"1982","unstructured":"Corke BC, Datta S, Ostheimer GW, Weiss JB, Alper MH. Spinal anaesthesia for caesarean section. The influence of hypotension on neonatal outcome. Anaesthesia. 1982, 37:658-62. 10.1111\/j.1365-2044.1982.tb01278.x","journal-title":"Anaesthesia"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.2005.04223.x","article-title":"Anaesthesia for caesarean section and neonatal acid-base status: a meta-analysis","volume":"60","author":"Reynolds F","year":"2005","unstructured":"Reynolds F, Seed PT. Anaesthesia for caesarean section and neonatal acid-base status: a meta-analysis. Anaesthesia. 2005, 60:636-53. 10.1111\/j.1365-2044.2005.04223.x","journal-title":"Anaesthesia"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1111\/j.1399-6576.1988.tb02786.x","article-title":"Vasopressor therapy for hypotension due to epidural anesthesia for cesarean section","volume":"32","author":"Ramanathan S","year":"1988","unstructured":"Ramanathan S, Grant GJ. Vasopressor therapy for hypotension due to epidural anesthesia for cesarean section. Acta Anaesthesiol Scand. 1988, 32:559-65. 10.1111\/j.1399-6576.1988.tb02786.x","journal-title":"Acta Anaesthesiol Scand"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1007\/s12630-017-1034-6","article-title":"A randomized trial of phenylephrine infusion versus bolus dosing for nausea and vomiting during cesarean delivery in obese women","volume":"65","author":"George RB","year":"2018","unstructured":"George RB, McKeen DM, Dominguez JE, Allen TK, Doyle PA, Habib AS. A randomized trial of phenylephrine infusion versus bolus dosing for nausea and vomiting during cesarean delivery in obese women. Can J Anaesth. 2018, 65:254-62. 10.1007\/s12630-017-1034-6","journal-title":"Can J Anaesth"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-200506000-00005","article-title":"Heart rate variability predicts severe hypotension after spinal anesthesia for elective cesarean delivery","volume":"102","author":"Hanss R","year":"2005","unstructured":"Hanss R, Bein B, Ledowski T, et al.. Heart rate variability predicts severe hypotension after spinal anesthesia for elective cesarean delivery. Anesthesiology. 2005, 102:1086-93. 10.1097\/00000542-200506000-00005","journal-title":"Anesthesiology"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1007\/s10877-009-9168-x","article-title":"Hypotension after spinal anesthesia for cesarean section: identification of risk factors using an anesthesia information management system","volume":"23","author":"Brenck F","year":"2009","unstructured":"Brenck F, Hartmann B, Katzer C, et al.. Hypotension after spinal anesthesia for cesarean section: identification of risk factors using an anesthesia information management system. J Clin Monit Comput. 2009, 23:85-92. 10.1007\/s10877-009-9168-x","journal-title":"J Clin Monit Comput"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1097\/00003246-200206000-00006","article-title":"Use of a peripheral perfusion index derived from the pulse oximetry signal as a noninvasive indicator of perfusion","volume":"30","author":"Lima AP","year":"2002","unstructured":"Lima AP, Beelen P, Bakker J. Use of a peripheral perfusion index derived from the pulse oximetry signal as a noninvasive indicator of perfusion. Crit Care Med. 2002, 30:1210-3. 10.1097\/00003246-200206000-00006","journal-title":"Crit Care Med"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/aet058","article-title":"Perfusion index derived from a pulse oximeter can predict the incidence of hypotension during spinal anaesthesia for Caesarean delivery","volume":"111","author":"Toyama S","year":"2013","unstructured":"Toyama S, Kakumoto M, Morioka M, et al.. Perfusion index derived from a pulse oximeter can predict the incidence of hypotension during spinal anaesthesia for Caesarean delivery. Br J Anaesth. 2013, 111:235-41. 10.1093\/bja\/aet058","journal-title":"Br J Anaesth"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.4103\/ija.IJA_429_16","article-title":"Perfusion index as a predictor of hypotension following spinal anaesthesia in lower segment caesarean section","volume":"61","author":"Duggappa DR","year":"2017","unstructured":"Duggappa DR, Lokesh M, Dixit A, Paul R, Raghavendra Rao RS, Prabha P. Perfusion index as a predictor of hypotension following spinal anaesthesia in lower segment caesarean section. Indian J Anaesth. 2017, 61:649-54. 10.4103\/ija.IJA_429_16","journal-title":"Indian J Anaesth"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.18231\/j.ijca.2024.057","article-title":"Role of Pleth variability index and perfusion index for predicting hypotension following spinal anaesthesia in patients undergoing caesarean section","volume":"25","author":"Paul A","year":"20242026","unstructured":"Paul A, Hemantkumar I, Saji DA, Patil M. Role of Pleth variability index and perfusion index for predicting hypotension following spinal anaesthesia in patients undergoing caesarean section. Indian J Clin Anaesth. 20242026, 25:289-94. 10.18231\/j.ijca.2024.057","journal-title":"Indian J Clin Anaesth"},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.18231\/j.ijca.2022.090","article-title":"Clinical evaluation of perfusion index (PI) as a predictor of post spinal hypotension in lower segment caesarean section (LSCS)","volume":"9","author":"Kumar U","year":"2022","unstructured":"Kumar U, Tripathi A, Somvanshi M, Karasala V. Clinical evaluation of perfusion index (PI) as a predictor of post spinal hypotension in lower segment caesarean section (LSCS). Indian J Clin Anaesth. 2022, 9:445-9. 10.18231\/j.ijca.2022.090","journal-title":"Indian J Clin Anaesth"},{"key":"ref18","doi-asserted-by":"publisher","DOI":"10.4103\/joacp.JOACP_385_20","article-title":"A study to evaluate perfusion index as a predictor of hypotension following spinal anesthesia for caesarean section","volume":"38","author":"Lal J","year":"2022","unstructured":"Lal J, Bansal T, Bhardwaj S, Jain M, Singh AK. A study to evaluate perfusion index as a predictor of hypotension following spinal anesthesia for caesarean section. J Anaesthesiol Clin Pharmacol. 2022, 38:294-9. 10.4103\/joacp.JOACP_385_20","journal-title":"J Anaesthesiol Clin Pharmacol"},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.3390\/diagnostics13152584","article-title":"Diagnostic accuracy of perfusion index for predicting hypotension after spinal anesthesia in cesarean section: a systematic review and meta-analysis","volume":"13","author":"Hung KC","year":"2023","unstructured":"Hung KC, Liu CC, Huang YT, et al.. Diagnostic accuracy of perfusion index for predicting hypotension after spinal anesthesia in cesarean section: a systematic review and meta-analysis. Diagnostics (Basel). 2023, 13:1452. 10.3390\/diagnostics13152584","journal-title":"Diagnostics (Basel)"},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.18231\/j.ijca.12283.1766394869","article-title":"Perfusion index as a predictor of hypotension following spinal anaesthesia - a prospective observational study","volume":"13","author":"Bhat SR","year":"2026","unstructured":"Bhat SR, Soori R. Perfusion index as a predictor of hypotension following spinal anaesthesia - a prospective observational study. Indian J Clin Anaesth. 2026, 13:170-5. 10.18231\/j.ijca.12283.1766394869","journal-title":"Indian J Clin Anaesth"},{"key":"ref21","unstructured":"Cesarean delivery. overview, preparation, technique. Medscape. (2023). Accessed: May 23, 2026: https:\/\/emedicine.medscape.com\/article\/2172425-overview."},{"key":"ref22","doi-asserted-by":"publisher","DOI":"10.1109\/TAC.1974.1100705","article-title":"A new look at the statistical model identification","volume":"19","author":"Akaike H","year":"1974","unstructured":"Akaike H. A new look at the statistical model identification. IEEE Trans Autom Control. 1974, 19:716-23. 10.1109\/TAC.1974.1100705","journal-title":"IEEE Trans Autom Control"},{"key":"ref23","doi-asserted-by":"publisher","DOI":"10.1214\/aos\/1176344136","article-title":"Estimating the dimension of a model","volume":"6","author":"Schwarz G","year":"1978","unstructured":"Schwarz G. Estimating the dimension of a model. Ann Statist. 1978, 6:461-4. 10.1214\/aos\/1176344136","journal-title":"Ann Statist"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/494953-baseline-perfusion-index-as-a-predictor-of-post-spinal-hypotension-in-elective-caesarean-section-a-prospective-observational-study","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,23]],"date-time":"2026-05-23T16:12:33Z","timestamp":1779552753000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/494953-baseline-perfusion-index-as-a-predictor-of-post-spinal-hypotension-in-elective-caesarean-section-a-prospective-observational-study"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,23]]},"references-count":23,"URL":"https:\/\/doi.org\/10.7759\/cureus.109506","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2026,5,23]]}}}