{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,26]],"date-time":"2026-05-26T07:03:28Z","timestamp":1779779008285,"version":"3.53.1"},"reference-count":29,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,5,25]]},"DOI":"10.7759\/cureus.109657","type":"journal-article","created":{"date-parts":[[2026,5,26]],"date-time":"2026-05-26T06:25:49Z","timestamp":1779776749000},"source":"Crossref","is-referenced-by-count":0,"title":["Development and Evaluation of a Low-Cost Phantom Model for Ultrasound-Guided Intercostal Chest Drain Insertion"],"prefix":"10.7759","author":[{"given":"Robert","family":"Pritchard","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eren","family":"Keskin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Muhammed","family":"Shahid","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Johann","family":"Willers","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"James","family":"Chu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexander","family":"Hall","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.4046\/trd.2017.0107","article-title":"Chest tube drainage of the pleural space: a concise review for pulmonologists","volume":"81","author":"Porcel JM","year":"2018","unstructured":"Porcel JM. Chest tube drainage of the pleural space: a concise review for pulmonologists. Tuberc Respir Dis (Seoul). 2018, 81:106-15. 10.4046\/trd.2017.0107","journal-title":"Tuberc Respir Dis (Seoul)"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1097\/TA.0000000000001840","article-title":"Complications in tube thoracostomy: systematic review and meta-analysis","volume":"85","author":"Hernandez MC","year":"2018","unstructured":"Hernandez MC, El Khatib M, Prokop L, Zielinski MD, Aho JM. Complications in tube thoracostomy: systematic review and meta-analysis. J Trauma Acute Care Surg. 2018, 85:410-6. 10.1097\/TA.0000000000001840","journal-title":"J Trauma Acute Care Surg"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajem.2025.07.049","article-title":"Ultrasound guidance compared to anatomic landmark approach for thoracentesis: a systematic review and meta-analysis","volume":"97","author":"Lakkadghatwala R","year":"2025","unstructured":"Lakkadghatwala R, Wilson A, Sabhaney V, et al.. Ultrasound guidance compared to anatomic landmark approach for thoracentesis: a systematic review and meta-analysis. Am J Emerg Med. 2025, 97:159-64. 10.1016\/j.ajem.2025.07.049","journal-title":"Am J Emerg Med"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.b4923","article-title":"Insertion of chest drains: summary of a safety report from the National Patient Safety Agency","volume":"339","author":"Lamont T","year":"2009","unstructured":"Lamont T, Surkitt-Parr M, Scarpello J, Durand M, Hooper C, Maskell N. Insertion of chest drains: summary of a safety report from the National Patient Safety Agency. BMJ. 2009, 339:b4923. 10.1136\/bmj.b4923","journal-title":"BMJ"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1136\/thx.2010.137026","article-title":"Pleural procedures and thoracic ultrasound: British Thoracic Society Pleural Disease Guideline 2010","volume":"65 Suppl 2","author":"Havelock T","year":"2010","unstructured":"Havelock T, Teoh R, Laws D, Gleeson F. Pleural procedures and thoracic ultrasound: British Thoracic Society Pleural Disease Guideline 2010. Thorax. 2010, 65 Suppl 2:ii61-76. 10.1136\/thx.2010.137026","journal-title":"Thorax"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1136\/thoraxjnl-2011-200077","article-title":"British Thoracic Society national pleural procedures audit 2010","volume":"66","author":"Hooper C","year":"2011","unstructured":"Hooper C, Maskell N. British Thoracic Society national pleural procedures audit 2010. Thorax. 2011, 66:636-7. 10.1136\/thoraxjnl-2011-200077","journal-title":"Thorax"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1007\/s00247-018-4171-3","article-title":"Real-time ultrasound-guided pigtail catheter chest drain for complicated parapneumonic effusion and empyema in children - 16-year, single-centre experience of radiologically placed drains","volume":"48","author":"Lewis MR","year":"2018","unstructured":"Lewis MR, Micic TA, Doull IJ, Evans A. Real-time ultrasound-guided pigtail catheter chest drain for complicated parapneumonic effusion and empyema in children - 16-year, single-centre experience of radiologically placed drains. Pediatr Radiol. 2018, 48:1410-6. 10.1007\/s00247-018-4171-3","journal-title":"Pediatr Radiol"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.3390\/diagnostics12030725","article-title":"Effectiveness and safety of real-time transthoracic ultrasound-guided thoracentesis","volume":"12","author":"Sperandeo M","year":"2022","unstructured":"Sperandeo M, Quarato CM, Squatrito R, et al.. Effectiveness and safety of real-time transthoracic ultrasound-guided thoracentesis. Diagnostics (Basel). 2022, 12:725. 10.3390\/diagnostics12030725","journal-title":"Diagnostics (Basel)"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1258\/smj.2011.011098","article-title":"Simulation in surgery: a review","volume":"56","author":"Tan SS","year":"2011","unstructured":"Tan SS, Sarker SK. Simulation in surgery: a review. Scott Med J. 2011, 56:104-9. 10.1258\/smj.2011.011098","journal-title":"Scott Med J"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1111\/j.1445-5994.2007.01586.x","article-title":"Using simulation models to teach junior doctors how to insert chest tubes: a brief and effective teaching module","volume":"38","author":"Hutton IA","year":"2008","unstructured":"Hutton IA, Kenealy H, Wong C. Using simulation models to teach junior doctors how to insert chest tubes: a brief and effective teaching module. Intern Med J. 2008, 38:887-91. 10.1111\/j.1445-5994.2007.01586.x","journal-title":"Intern Med J"},{"key":"ref11","unstructured":"General Medical Council. Internal medicine stage one curriculum.. (2019). Accessed: March 1, 2025: https:\/\/www.gmc-uk.org\/education\/standards-guidance-and-curricula\/curricula\/internal-medicine---stage-one."},{"key":"ref12","article-title":"Simulation training for pleural procedures: a review","volume":"1","author":"Thorley-Dickinson V","year":"2014","unstructured":"Thorley-Dickinson V, Prakash A, Fernando X, Kastelik J. Simulation training for pleural procedures: a review. Metr J. 2014, 1:17.","journal-title":"Metr J"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1186\/s12909-023-04978-8","article-title":"Training, experience, and perceptions of chest tube insertion by higher speciality trainees: implications for training, patient safety, and service delivery","volume":"24","author":"Probyn B","year":"2024","unstructured":"Probyn B, Daneshvar C, Price T. Training, experience, and perceptions of chest tube insertion by higher speciality trainees: implications for training, patient safety, and service delivery. BMC Med Educ. 2024, 24:12. 10.1186\/s12909-023-04978-8","journal-title":"BMC Med Educ"},{"key":"ref14","unstructured":"Sim &amp; Skills. Chest tube manikin.. Accessed: December 17, 2024: https:\/\/simandskills.co.uk\/products\/chest-tube-manikin."},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.5811\/westjem.2018.9.39456","article-title":"Yogaman: an inexpensive, anatomically detailed chest tube placement trainer","volume":"20","author":"Young TP","year":"2019","unstructured":"Young TP, Schaefer MD, Kuntz HM, Estes MK, Kiemeney M, Wolk BJ, Guptill M. Yogaman: an inexpensive, anatomically detailed chest tube placement trainer. West J Emerg Med. 2019, 20:117-21. 10.5811\/westjem.2018.9.39456","journal-title":"West J Emerg Med"},{"key":"ref16","article-title":"Adamgel: an economical, easily prepared, versatile, self-repairing and recyclable tissue analogue for procedural simulation training","volume":"1","author":"Willers J","year":"2015","unstructured":"Willers J, Colucci G, Roberts A, Barnes L. Adamgel: an economical, easily prepared, versatile, self-repairing and recyclable tissue analogue for procedural simulation training. BMJ Simul Technol Enhanc Learn. 2015, 1:27.","journal-title":"BMJ Simul Technol Enhanc Learn"},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.2004.03810.x","article-title":"A homemade model for training in cricothyrotomy","volume":"59","author":"Varaday SS","year":"2004","unstructured":"Varaday SS, Yentis SM, Clarke S. A homemade model for training in cricothyrotomy. Anaesthesia. 2004, 59:1012-5. 10.1111\/j.1365-2044.2004.03810.x","journal-title":"Anaesthesia"},{"key":"ref18","doi-asserted-by":"publisher","DOI":"10.1186\/2036-7902-4-19","article-title":"The V-line: a sonographic aid for the confirmation of pleural fluid","volume":"4","author":"Atkinson P","year":"2012","unstructured":"Atkinson P, Milne J, Loubani O, Verheul G. The V-line: a sonographic aid for the confirmation of pleural fluid. Crit Ultrasound J. 2012, 4:19. 10.1186\/2036-7902-4-19","journal-title":"Crit Ultrasound J"},{"key":"ref19","article-title":"The how, when, and why of high-fidelity simulation","author":"Carey JM","year":"2023","unstructured":"Carey JM, Rossler K. The how, when, and why of high-fidelity simulation. StatPearls [Internet]. StatPearls Publishing, Treasure Island (FL); 2023."},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.3810\/hp.2014.10.1150","article-title":"Impact of levels of simulation fidelity on training of interns in ACLS","volume":"42","author":"Conlon LW","year":"2014","unstructured":"Conlon LW, Rodgers DL, Shofer FS, Lipschik GY. Impact of levels of simulation fidelity on training of interns in ACLS. Hosp Pract (1995). 2014, 42:135-41. 10.3810\/hp.2014.10.1150","journal-title":"Hosp Pract (1995)"},{"key":"ref21","doi-asserted-by":"publisher","DOI":"10.1002\/jhm.268","article-title":"Mastery learning of thoracentesis skills by internal medicine residents using simulation technology and deliberate practice","volume":"3","author":"Wayne DB","year":"2008","unstructured":"Wayne DB, Barsuk JH, O'Leary KJ, Fudala MJ, McGaghie WC. Mastery learning of thoracentesis skills by internal medicine residents using simulation technology and deliberate practice. J Hosp Med. 2008, 3:48-54. 10.1002\/jhm.268","journal-title":"J Hosp Med"},{"key":"ref22","doi-asserted-by":"publisher","DOI":"10.1136\/postgradmedj-2014-133155","article-title":"Intercostal chest drain insertion by general physicians: attitudes, experience and implications for training, service and patient safety","volume":"91","author":"Corcoran JP","year":"2015","unstructured":"Corcoran JP, Hallifax RJ, Talwar A, Psallidas I, Sykes A, Rahman NM. Intercostal chest drain insertion by general physicians: attitudes, experience and implications for training, service and patient safety. Postgrad Med J. 2015, 91:244-50. 10.1136\/postgradmedj-2014-133155","journal-title":"Postgrad Med J"},{"key":"ref23","doi-asserted-by":"publisher","DOI":"10.1097\/00001888-200506000-00006","article-title":"Evaluating clinical simulations for learning procedural skills: a theory-based approach","volume":"80","author":"Kneebone R","year":"2005","unstructured":"Kneebone R. Evaluating clinical simulations for learning procedural skills: a theory-based approach. Acad Med. 2005, 80:549-53. 10.1097\/00001888-200506000-00006","journal-title":"Acad Med"},{"key":"ref24","doi-asserted-by":"publisher","DOI":"10.1186\/s12909-022-03654-7","article-title":"The impact of simulation-based mastery learning, booster session timing and clinical exposure on confidence in intercostal drain insertion: a survey of internal medicine trainees in Scotland","volume":"22","author":"Kerins J","year":"2022","unstructured":"Kerins J, McCully E, Stirling SA, Smith SE, Tiernan J, Tallentire VR. The impact of simulation-based mastery learning, booster session timing and clinical exposure on confidence in intercostal drain insertion: a survey of internal medicine trainees in Scotland. BMC Med Educ. 2022, 22:621. 10.1186\/s12909-022-03654-7","journal-title":"BMC Med Educ"},{"key":"ref25","doi-asserted-by":"publisher","DOI":"10.7861\/clinmedicine.12-1-49","article-title":"Validation of a novel resin-porcine thorax model for chest drain insertion training","volume":"12","author":"Naicker TR","year":"2012","unstructured":"Naicker TR, Hughes EA, McLeod DT. Validation of a novel resin-porcine thorax model for chest drain insertion training. Clin Med (Lond). 2012, 12:49-52. 10.7861\/clinmedicine.12-1-49","journal-title":"Clin Med (Lond)"},{"key":"ref26","doi-asserted-by":"publisher","DOI":"10.1097\/SIH.0000000000000071","article-title":"Testing of a complete training model for chest tube insertion in traumatic pneumothorax","volume":"10","author":"Ghazali A","year":"2015","unstructured":"Ghazali A, Breque C, L\u00e9ger A, Sc\u00e9pi M, Oriot D. Testing of a complete training model for chest tube insertion in traumatic pneumothorax. Simul Healthc. 2015, 10:239-44. 10.1097\/SIH.0000000000000071","journal-title":"Simul Healthc"},{"key":"ref27","article-title":"Mannequin simulation improves the confidence of medical students performing tube thoracostomy: a prospective, controlled trial","volume":"76","author":"Hishikawa S","year":"2010","unstructured":"Hishikawa S, Kawano M, Tanaka H, et al.. Mannequin simulation improves the confidence of medical students performing tube thoracostomy: a prospective, controlled trial. Am Surg. 2010, 76:73-8.","journal-title":"Am Surg"},{"key":"ref28","doi-asserted-by":"publisher","DOI":"10.1186\/s12909-019-1464-7","article-title":"High-fidelity is not superior to low-fidelity simulation but leads to overconfidence in medical students","volume":"19","author":"Massoth C","year":"2019","unstructured":"Massoth C, R\u00f6der H, Ohlenburg H, Hessler M, Zarbock A, P\u00f6pping DM, Wenk M. High-fidelity is not superior to low-fidelity simulation but leads to overconfidence in medical students. BMC Med Educ. 2019, 19:29. 10.1186\/s12909-019-1464-7","journal-title":"BMC Med Educ"},{"key":"ref29","doi-asserted-by":"publisher","DOI":"10.1046\/j.1365-2923.2004.01773.x","article-title":"Clinical skills in junior medical officers: a comparison of self-reported confidence and observed competence","volume":"38","author":"Barnsley L","year":"2004","unstructured":"Barnsley L, Lyon PM, Ralston SJ, Hibbert EJ, Cunningham I, Gordon FC, Field MJ. Clinical skills in junior medical officers: a comparison of self-reported confidence and observed competence. Med Educ. 2004, 38:358-67. 10.1046\/j.1365-2923.2004.01773.x","journal-title":"Med Educ"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/483550-development-and-evaluation-of-a-low-cost-phantom-model-for-ultrasound-guided-intercostal-chest-drain-insertion","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,26]],"date-time":"2026-05-26T06:25:51Z","timestamp":1779776751000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/483550-development-and-evaluation-of-a-low-cost-phantom-model-for-ultrasound-guided-intercostal-chest-drain-insertion"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,25]]},"references-count":29,"URL":"https:\/\/doi.org\/10.7759\/cureus.109657","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2026,5,25]]}}}