{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,3]],"date-time":"2026-06-03T15:06:20Z","timestamp":1780499180286,"version":"3.54.1"},"reference-count":19,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,6,3]]},"DOI":"10.7759\/cureus.110180","type":"journal-article","created":{"date-parts":[[2026,6,3]],"date-time":"2026-06-03T14:13:16Z","timestamp":1780495996000},"source":"Crossref","is-referenced-by-count":0,"title":["Association Between Implant Positioning Parameters and Prosthetic Failure in Full-Arch Fixed Implant-Supported Prostheses: A Retrospective Matched Case-Control Study"],"prefix":"10.7759","author":[{"given":"Sumanjit","family":"Midha","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sami Faisal","family":"Jamdar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sunaina","family":"Singla","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jasvinder","family":"Kaur","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jeevani","family":"Eppala","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jay","family":"Gohil","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Akriti","family":"Mahajan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.7759\/cureus.99222","article-title":"Prosthetic options for full-mouth implant rehabilitation: a contemporary review","volume":"17","author":"Surabathula D","year":"2025","unstructured":"Surabathula D, Birajdar S, Joshi M, Vaz M, Kadam N. Prosthetic options for full-mouth implant rehabilitation: a contemporary review. Cureus. 2025, 17:e99222. 10.7759\/cureus.99222","journal-title":"Cureus"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.7759\/cureus.78091","article-title":"Patient-reported outcomes of dental implants in type 2 diabetes: a cross-sectional study on quality of life and satisfaction","volume":"17","author":"Davangere U","year":"2025","unstructured":"Davangere U, Khan E, Chaudhary H, Mulani S, B S, Gupta S. Patient-reported outcomes of dental implants in type 2 diabetes: a cross-sectional study on quality of life and satisfaction. Cureus. 2025, 17:e78091. 10.7759\/cureus.78091","journal-title":"Cureus"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1016\/j.jobcr.2023.02.009","article-title":"Mechanical failures of dental implants and supported prostheses: a systematic review","volume":"13","author":"Verma A","year":"2023","unstructured":"Verma A, Singh SV, Arya D, Shivakumar S, Chand P. Mechanical failures of dental implants and supported prostheses: a systematic review. J Oral Biol Craniofac Res. 2023, 13:306-14. 10.1016\/j.jobcr.2023.02.009","journal-title":"J Oral Biol Craniofac Res"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.7759\/cureus.75192","article-title":"Predictive factors of dental implant failure: a retrospective study using decision tree regression","volume":"16","author":"Shahapur SG","year":"2024","unstructured":"Shahapur SG, Patil K, Manhas S, Datta N, Jadhav P, Gupta S. Predictive factors of dental implant failure: a retrospective study using decision tree regression. Cureus. 2024, 16:e75192. 10.7759\/cureus.75192","journal-title":"Cureus"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.7759\/cureus.30455","article-title":"The etiology and management of dental implant failure: a review","volume":"14","author":"Kochar SP","year":"2022","unstructured":"Kochar SP, Reche A, Paul P. The etiology and management of dental implant failure: a review. Cureus. 2022, 14:e30455. 10.7759\/cureus.30455","journal-title":"Cureus"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1111\/jcpe.12829","article-title":"Restoration contour is a risk indicator for peri-implantitis: a cross-sectional radiographic analysis","volume":"45","author":"Katafuchi M","year":"2018","unstructured":"Katafuchi M, Weinstein BF, Leroux BG, Chen YW, Daubert DM. Restoration contour is a risk indicator for peri-implantitis: a cross-sectional radiographic analysis. J Clin Periodontol. 2018, 45:225-32. 10.1111\/jcpe.12829","journal-title":"J Clin Periodontol"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.3390\/ma13081883","article-title":"Errors in implant positioning due to lack of planning: a clinical case report of new prosthetic materials and solutions","volume":"13","author":"Tallarico M","year":"2020","unstructured":"Tallarico M, Scrascia R, Annucci M, et al.. Errors in implant positioning due to lack of planning: a clinical case report of new prosthetic materials and solutions. Materials (Basel). 2020, 13:10.3390\/ma13081883","journal-title":"Materials (Basel)"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1016\/j.prosdent.2020.05.020","article-title":"Long-term chipping and failure rates of implant-supported and combined tooth-implant-supported metal-ceramic and ceramic fixed dental prostheses: a cohort study","volume":"126","author":"Rammelsberg P","year":"2021","unstructured":"Rammelsberg P, Meyer A, Lorenzo-Bermejo J, Kappel S, Zenth\u00f6fer A. Long-term chipping and failure rates of implant-supported and combined tooth-implant-supported metal-ceramic and ceramic fixed dental prostheses: a cohort study. J Prosthet Dent. 2021, 126:196-203. 10.1016\/j.prosdent.2020.05.020","journal-title":"J Prosthet Dent"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1177\/0022034511431252","article-title":"Success criteria in implant dentistry: a systematic review","volume":"91","author":"Papaspyridakos P","year":"2012","unstructured":"Papaspyridakos P, Chen CJ, Singh M, Weber HP, Gallucci GO. Success criteria in implant dentistry: a systematic review. J Dent Res. 2012, 91:242-8. 10.1177\/0022034511431252","journal-title":"J Dent Res"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.3390\/clinpract15070134","article-title":"Mechanical and biological complications two years after full-arch implant-supported prosthetic rehabilitation: a retrospective clinical study","volume":"15","author":"Sab\u0103u DT","year":"2025","unstructured":"Sab\u0103u DT, Saitos P, Moca RT, Juncar RI, Juncar M. Mechanical and biological complications two years after full-arch implant-supported prosthetic rehabilitation: a retrospective clinical study. Clin Pract. 2025, 15:10.3390\/clinpract15070134","journal-title":"Clin Pract"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.5125\/jkaoms.2020.46.2.133","article-title":"Clinical study on screw loosening in dental implant prostheses: a 6-year retrospective study","volume":"46","author":"Lee KY","year":"2020","unstructured":"Lee KY, Shin KS, Jung JH, Cho HW, Kwon KH, Kim YL. Clinical study on screw loosening in dental implant prostheses: a 6-year retrospective study. J Korean Assoc Oral Maxillofac Surg. 2020, 46:133-42. 10.5125\/jkaoms.2020.46.2.133","journal-title":"J Korean Assoc Oral Maxillofac Surg"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1186\/s12903-024-04091-2","article-title":"A finite element analysis study on different angle correction designs for inclined implants in All-On-Four protocol","volume":"24","author":"Ibrahim CR","year":"2024","unstructured":"Ibrahim CR, Sameh A, Askar O. A finite element analysis study on different angle correction designs for inclined implants in All-On-Four protocol. BMC Oral Health. 2024, 24:331. 10.1186\/s12903-024-04091-2","journal-title":"BMC Oral Health"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1016\/s0022-3913(96)90301-7","article-title":"Finite element analysis of the effect of cantilever and implant length on stress distribution in an implant-supported fixed prosthesis","volume":"76","author":"Sertg\u00f6z A","year":"1996","unstructured":"Sertg\u00f6z A, G\u00fcvener S. Finite element analysis of the effect of cantilever and implant length on stress distribution in an implant-supported fixed prosthesis. J Prosthet Dent. 1996, 76:165-9. 10.1016\/s0022-3913(96)90301-7","journal-title":"J Prosthet Dent"},{"key":"ref14","article-title":"Forces and moments on Branemark implants","volume":"4","author":"Rangert B","year":"1989","unstructured":"Rangert B, Jemt T, J\u00f6rneus L. Forces and moments on Branemark implants. Int J Oral Maxillofac Implants. 1989, 4:241-7.","journal-title":"Int J Oral Maxillofac Implants"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0501.2006.01307.x","article-title":"A 10-year prospective study of ITI dental implants placed in the posterior region. II: Influence of the crown-to-implant ratio and different prosthetic treatment modalities on crestal bone loss","volume":"18","author":"Blanes RJ","year":"2007","unstructured":"Blanes RJ, Bernard JP, Blanes ZM, Belser UC. A 10-year prospective study of ITI dental implants placed in the posterior region. II: Influence of the crown-to-implant ratio and different prosthetic treatment modalities on crestal bone loss. Clin Oral Implants Res. 2007, 18:707-14. 10.1111\/j.1600-0501.2006.01307.x","journal-title":"Clin Oral Implants Res"},{"key":"ref16","article-title":"Determination of cantilever length-anterior-posterior spread ratio assuming failure criteria to be the compromise of the prosthesis retaining screw-prosthesis joint","volume":"11","author":"McAlarney ME","year":"1996","unstructured":"McAlarney ME, Stavropoulos DN. Determination of cantilever length-anterior-posterior spread ratio assuming failure criteria to be the compromise of the prosthesis retaining screw-prosthesis joint. Int J Oral Maxillofac Implants. 1996, 11:331-9.","journal-title":"Int J Oral Maxillofac Implants"},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.1016\/0022-3913(83)90361-x","article-title":"Biomechanical considerations in osseointegrated prostheses","volume":"49","author":"Skalak R","year":"1983","unstructured":"Skalak R. Biomechanical considerations in osseointegrated prostheses. J Prosthet Dent. 1983, 49:843-8. 10.1016\/0022-3913(83)90361-x","journal-title":"J Prosthet Dent"},{"key":"ref18","article-title":"Tilting of posterior mandibular and maxillary implants for improved prosthesis support","volume":"15","author":"Krekmanov L","year":"2000","unstructured":"Krekmanov L, Kahn M, Rangert B, Lindstr\u00f6m H. Tilting of posterior mandibular and maxillary implants for improved prosthesis support. Int J Oral Maxillofac Implants. 2000, 15:405-14.","journal-title":"Int J Oral Maxillofac Implants"},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0501.2009.01893.x","article-title":"Bone alterations at implant-supported FDPs in relation to inter-unit distances: a 5-year radiographic study","volume":"21","author":"Chang M","year":"2010","unstructured":"Chang M, Wennstr\u00f6m JL. Bone alterations at implant-supported FDPs in relation to inter-unit distances: a 5-year radiographic study. Clin Oral Implants Res. 2010, 21:735-40. 10.1111\/j.1600-0501.2009.01893.x","journal-title":"Clin Oral Implants Res"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/496038-association-between-implant-positioning-parameters-and-prosthetic-failure-in-full-arch-fixed-implant-supported-prostheses-a-retrospective-matched-case-control-study","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,3]],"date-time":"2026-06-03T14:13:17Z","timestamp":1780495997000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/496038-association-between-implant-positioning-parameters-and-prosthetic-failure-in-full-arch-fixed-implant-supported-prostheses-a-retrospective-matched-case-control-study"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,3]]},"references-count":19,"URL":"https:\/\/doi.org\/10.7759\/cureus.110180","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2026,6,3]]}}}