{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,6]],"date-time":"2026-06-06T13:02:14Z","timestamp":1780750934943,"version":"3.54.1"},"reference-count":35,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,6,6]]},"DOI":"10.7759\/cureus.110349","type":"journal-article","created":{"date-parts":[[2026,6,6]],"date-time":"2026-06-06T12:50:18Z","timestamp":1780750218000},"source":"Crossref","is-referenced-by-count":0,"title":["Efficacy and Safety of Navitor Versus Sapien Valves in Transcatheter Aortic Valve Implantation: A Systematic Review and Meta-Analysis"],"prefix":"10.7759","author":[{"given":"Yusuf","family":"Ahmed","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Abdulla","family":"Almubarak","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Manar","family":"Ali","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jaafar Alsadeq","family":"Laith","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lujayn","family":"Juma","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Walaa","family":"Yusuf","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zahraa","family":"Salman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hana","family":"Asser","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohamed","family":"Gabr","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ahmed","family":"Emara","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1161\/ATVBAHA.119.313067","article-title":"Aortic valve stenosis: from basic mechanisms to novel therapeutic targets","volume":"40","author":"Goody PR","year":"2020","unstructured":"Goody PR, Hosen MR, Christmann D, et al.. Aortic valve stenosis: from basic mechanisms to novel therapeutic targets. Arterioscler Thromb Vasc Biol. 2020, 40:885-900. 10.1161\/ATVBAHA.119.313067","journal-title":"Arterioscler Thromb Vasc Biol"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.3390\/jcdd9080282","article-title":"Technical aspects and development of transcatheter aortic valve implantation","volume":"9","author":"Steblovnik K","year":"2022","unstructured":"Steblovnik K, Bunc M. Technical aspects and development of transcatheter aortic valve implantation. J Cardiovasc Dev Dis. 2022, 9:282. 10.3390\/jcdd9080282","journal-title":"J Cardiovasc Dev Dis"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehaf194","article-title":"2025 ESC\/EACTS guidelines for the management of valvular heart disease: developed by the task force for the management of valvular heart disease of the European Society of Cardiology (ESC) and the European Association for Cardio-Thoracic Surgery (EACTS)","volume":"46","author":"Praz F","year":"2025","unstructured":"Praz F, Borger MA, Lanz J, et al.. 2025 ESC\/EACTS guidelines for the management of valvular heart disease: developed by the task force for the management of valvular heart disease of the European Society of Cardiology (ESC) and the European Association for Cardio-Thoracic Surgery (EACTS). Eur Heart J. 2025, 46:4635-736. 10.1093\/eurheartj\/ehaf194","journal-title":"Eur Heart J"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1161\/CIR.0000000000000923","article-title":"2020 ACC\/AHA guideline for the management of patients with valvular heart disease: a report of the American College of Cardiology\/American Heart Association Joint Committee on Clinical Practice Guidelines","volume":"143","author":"Otto CM","year":"2021","unstructured":"Otto CM, Nishimura RA, Bonow RO, et al.. 2020 ACC\/AHA guideline for the management of patients with valvular heart disease: a report of the American College of Cardiology\/American Heart Association Joint Committee on Clinical Practice Guidelines. Circulation. 2021, 143:e72-227. 10.1161\/CIR.0000000000000923","journal-title":"Circulation"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.4244\/EIJ-D-22-01108","article-title":"Thirty-day and one-year outcomes of the Navitor transcatheter heart valve in patients with aortic stenosis: the prospective, multicentre, global PORTICO NG Study","volume":"19","author":"Sondergaard L","year":"2023","unstructured":"Sondergaard L, Walton AS, Worthley SG, et al.. Thirty-day and one-year outcomes of the Navitor transcatheter heart valve in patients with aortic stenosis: the prospective, multicentre, global PORTICO NG Study. EuroIntervention. 2023, 19:248-55. 10.4244\/EIJ-D-22-01108","journal-title":"EuroIntervention"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.3390\/jcm14061824","article-title":"Does intra-annular valve design equal intra-annular valve design? Comparison of two transcatheter aortic valve prostheses","volume":"14","author":"Eckel C","year":"2025","unstructured":"Eckel C, Al-Rashid F, Bargon S, et al.. Does intra-annular valve design equal intra-annular valve design? Comparison of two transcatheter aortic valve prostheses. J Clin Med. 2025, 14:1824. 10.3390\/jcm14061824","journal-title":"J Clin Med"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcin.2025.03.015","article-title":"Transcatheter aortic valve replacement with intra-annular self-expanding or balloon-expandable valves: the multicenter international NAVULTRA Registry","volume":"18","author":"Cannata S","year":"2025","unstructured":"Cannata S, Sultan I, Van Mieghem N, et al.. Transcatheter aortic valve replacement with intra-annular self-expanding or balloon-expandable valves: the multicenter international NAVULTRA Registry. JACC Cardiovasc Interv. 2025, 18:1557-68. 10.1016\/j.jcin.2025.03.015","journal-title":"JACC Cardiovasc Interv"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.29317","article-title":"Effect of a fourth-generation transcatheter valve enhanced skirt on paravalvular leak","volume":"97","author":"Welle GA","year":"2021","unstructured":"Welle GA, El-Sabawi B, Thaden JJ, et al.. Effect of a fourth-generation transcatheter valve enhanced skirt on paravalvular leak. Catheter Cardiovasc Interv. 2021, 97:895-902. 10.1002\/ccd.29317","journal-title":"Catheter Cardiovasc Interv"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcin.2024.02.015","article-title":"Real-world outcomes for the fifth-generation balloon expandable transcatheter heart valve in the United\u00a0States","volume":"17","author":"Stinis CT","year":"2024","unstructured":"Stinis CT, Abbas AE, Teirstein P, et al.. Real-world outcomes for the fifth-generation balloon expandable transcatheter heart valve in the United\u00a0States. JACC Cardiovasc Interv. 2024, 17:1032-44. 10.1016\/j.jcin.2024.02.015","journal-title":"JACC Cardiovasc Interv"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCINTERVENTIONS.121.010543","article-title":"Real-world experience with the SAPIEN 3 Ultra transcatheter heart valve: a propensity-matched analysis from the United States","volume":"14","author":"Nazif TM","year":"2021","unstructured":"Nazif TM, Cahill TJ, Daniels D, et al.. Real-world experience with the SAPIEN 3 Ultra transcatheter heart valve: a propensity-matched analysis from the United States. Circ Cardiovasc Interv. 2021, 14:e010543. 10.1161\/CIRCINTERVENTIONS.121.010543","journal-title":"Circ Cardiovasc Interv"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1002\/hsr2.70097","article-title":"Clinical outcomes, hemodynamics, and leaflet thrombosis following transcatheter aortic valve replacement with novel intra-annular devices","volume":"8","author":"Iwata J","year":"2025","unstructured":"Iwata J, Hayashida K, Kajino A, et al.. Clinical outcomes, hemodynamics, and leaflet thrombosis following transcatheter aortic valve replacement with novel intra-annular devices. Health Sci Rep. 2025, 8:e70097. 10.1002\/hsr2.70097","journal-title":"Health Sci Rep"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcin.2023.02.002","article-title":"30-day clinical outcomes of a self-expanding transcatheter aortic valve: the International Portico NG study","volume":"16","author":"Reardon MJ","year":"2023","unstructured":"Reardon MJ, Chehab B, Smith D, et al.. 30-day clinical outcomes of a self-expanding transcatheter aortic valve: the International Portico NG study. JACC Cardiovasc Interv. 2023, 16:681-9. 10.1016\/j.jcin.2023.02.002","journal-title":"JACC Cardiovasc Interv"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.n71","article-title":"The PRISMA 2020 statement: an updated guideline for reporting systematic reviews","volume":"372","author":"Page MJ","year":"2021","unstructured":"Page MJ, McKenzie JE, Bossuyt PM, et al.. The PRISMA 2020 statement: an updated guideline for reporting systematic reviews. BMJ. 2021, 372:n71. 10.1136\/bmj.n71","journal-title":"BMJ"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2021.02.038","article-title":"Valve Academic Research Consortium 3: updated endpoint definitions for aortic\u00a0valve clinical research","volume":"77","author":"G\u00e9n\u00e9reux P","year":"2021","unstructured":"G\u00e9n\u00e9reux P, Piazza N, Alu MC, et al.. Valve Academic Research Consortium 3: updated endpoint definitions for aortic\u00a0valve clinical research. J Am Coll Cardiol. 2021, 77:2717-46. 10.1016\/j.jacc.2021.02.038","journal-title":"J Am Coll Cardiol"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.i4919","article-title":"ROBINS-I: a tool for assessing risk of bias in non-randomised studies of interventions","volume":"355","author":"Sterne JA","year":"2016","unstructured":"Sterne JA, Hern\u00e1n MA, Reeves BC, et al.. ROBINS-I: a tool for assessing risk of bias in non-randomised studies of interventions. BMJ. 2016, 355:i4919. 10.1136\/bmj.i4919","journal-title":"BMJ"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.1016\/j.carrev.2025.06.036","article-title":"SAPIEN3 Ultra RESILIA versus NAVITOR valve system in patients with a small aortic annulus: insights from the OCEAN-TAVI Registry","volume":"85","author":"Mizutani K","year":"2026","unstructured":"Mizutani K, Yamamoto M, Hioki H, et al.. SAPIEN3 Ultra RESILIA versus NAVITOR valve system in patients with a small aortic annulus: insights from the OCEAN-TAVI Registry. Cardiovasc Revasc Med. 2026, 85:21-7. 10.1016\/j.carrev.2025.06.036","journal-title":"Cardiovasc Revasc Med"},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.17925\/HI.2024.18.1.4","article-title":"A comprehensive evaluation of the Navitor transcatheter aortic valve replacement system","volume":"18","author":"Aoun J","year":"2024","unstructured":"Aoun J, Zaid S, Goel S, Reardon MJ. A comprehensive evaluation of the Navitor transcatheter aortic valve replacement system. Heart Int. 2024, 18:26-9. 10.17925\/HI.2024.18.1.4","journal-title":"Heart Int"},{"key":"ref18","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.29281","article-title":"Hemodynamic comparison of transcatheter aortic valve replacement with the SAPIEN 3 Ultra versus SAPIEN 3: the HomoSAPIEN registry","volume":"97","author":"Moriyama N","year":"2021","unstructured":"Moriyama N, Lehtola H, Miyashita H, Piuhola J, Niemel\u00e4 M, Laine M. Hemodynamic comparison of transcatheter aortic valve replacement with the SAPIEN 3 Ultra versus SAPIEN 3: the HomoSAPIEN registry. Catheter Cardiovasc Interv. 2021, 97:E982-91. 10.1002\/ccd.29281","journal-title":"Catheter Cardiovasc Interv"},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.4244\/EIJ-D-23-00996","article-title":"Performance and outcomes of the SAPIEN 3 Ultra RESILIA transcatheter heart valve in the OCEAN-TAVI registry","volume":"20","author":"Yamamoto M","year":"2024","unstructured":"Yamamoto M, Yashima F, Shirai S, et al.. Performance and outcomes of the SAPIEN 3 Ultra RESILIA transcatheter heart valve in the OCEAN-TAVI registry. EuroIntervention. 2024, 20:579-90. 10.4244\/EIJ-D-23-00996","journal-title":"EuroIntervention"},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.3390\/jcm12123999","article-title":"Comparison of the new-generation self-expanding NAVITOR transcatheter heart valve with its predecessor, the PORTICO, in severe native aortic valve stenosis","volume":"12","author":"Eckel CE","year":"2023","unstructured":"Eckel CE, Kim WK, Grothusen C, et al.. Comparison of the new-generation self-expanding NAVITOR transcatheter heart valve with its predecessor, the PORTICO, in severe native aortic valve stenosis. J Clin Med. 2023, 12:3999. 10.3390\/jcm12123999","journal-title":"J Clin Med"},{"key":"ref21","doi-asserted-by":"publisher","DOI":"10.1093\/EURHEARTJ\/EHT309.2584","article-title":"Impact of paravalvular leak following transcatheter aortic valve replacement on one-year mortality: analysis of the combined PARTNER cohorts","volume":"34","author":"Kodali S","year":"2013","unstructured":"Kodali S, Hahn R, Williams M, et al.. Impact of paravalvular leak following transcatheter aortic valve replacement on one-year mortality: analysis of the combined PARTNER cohorts. Eur Heart J. 2013, 34:2584. 10.1093\/EURHEARTJ\/EHT309.2584","journal-title":"Eur Heart J"},{"key":"ref22","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehz924","article-title":"Clinical impact of conduction disturbances in transcatheter aortic valve replacement recipients: a systematic review and meta-analysis","volume":"41","author":"Faroux L","year":"2020","unstructured":"Faroux L, Chen S, Muntan\u00e9-Carol G, et al.. Clinical impact of conduction disturbances in transcatheter aortic valve replacement recipients: a systematic review and meta-analysis. Eur Heart J. 2020, 41:2771-81. 10.1093\/eurheartj\/ehz924","journal-title":"Eur Heart J"},{"key":"ref23","doi-asserted-by":"publisher","DOI":"10.7759\/cureus.5005","article-title":"Permanent pacemaker implantation after transcatheter aortic valve replacement: a cost analysis","volume":"11","author":"Ahmad M","year":"2019","unstructured":"Ahmad M, Patel JN, Loc BL, et al.. Permanent pacemaker implantation after transcatheter aortic valve replacement: a cost analysis. Cureus. 2019, 11:e5005. 10.7759\/cureus.5005","journal-title":"Cureus"},{"key":"ref24","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCINTERVENTIONS.122.012294","article-title":"Real-world multiple comparison of transcatheter aortic valves: insights from the multicenter OBSERVANT II study","volume":"15","author":"Costa G","year":"2022","unstructured":"Costa G, Barbanti M, Rosato S, et al.. Real-world multiple comparison of transcatheter aortic valves: insights from the multicenter OBSERVANT II study. Circ Cardiovasc Interv. 2022, 15:e012294. 10.1161\/CIRCINTERVENTIONS.122.012294","journal-title":"Circ Cardiovasc Interv"},{"key":"ref25","doi-asserted-by":"publisher","DOI":"10.1161\/JAHA.120.015896","article-title":"Pacemaker implantation after balloon- or self-expandable transcatheter aortic valve replacement in patients with aortic stenosis","volume":"9","author":"Bisson A","year":"2020","unstructured":"Bisson A, Bodin A, Herbert J, et al.. Pacemaker implantation after balloon- or self-expandable transcatheter aortic valve replacement in patients with aortic stenosis. J Am Heart Assoc. 2020, 9:e015896. 10.1161\/JAHA.120.015896","journal-title":"J Am Heart Assoc"},{"key":"ref26","doi-asserted-by":"publisher","DOI":"10.1016\/j.amjcard.2023.12.007","article-title":"Balloon-expandable versus self-expandable valve in transcatheter aortic valve replacement: a nation-wide study","volume":"213","author":"Sa YK","year":"2024","unstructured":"Sa YK, Choi IJ, Chang K, et al.. Balloon-expandable versus self-expandable valve in transcatheter aortic valve replacement: a nation-wide study. Am J Cardiol. 2024, 213:119-25. 10.1016\/j.amjcard.2023.12.007","journal-title":"Am J Cardiol"},{"key":"ref27","doi-asserted-by":"publisher","DOI":"10.1016\/j.shj.2024.100293","article-title":"Predictors and trends of new permanent pacemaker implantation: a subanalysis of the International Navitor IDE study","volume":"8","author":"Sultan I","year":"2024","unstructured":"Sultan I, Reardon MJ, S\u00f8ndergaard L, et al.. Predictors and trends of new permanent pacemaker implantation: a subanalysis of the International Navitor IDE study. Struct Heart. 2024, 8:100293. 10.1016\/j.shj.2024.100293","journal-title":"Struct Heart"},{"key":"ref28","doi-asserted-by":"publisher","DOI":"10.1016\/j.carrev.2025.04.039","article-title":"Predictors of permanent pacemaker implantation after TAVI with Navitor transcatheter heart valve","volume":"79","author":"Casenghi M","year":"2025","unstructured":"Casenghi M, Corradetti S, Rigattieri S, et al.. Predictors of permanent pacemaker implantation after TAVI with Navitor transcatheter heart valve. Cardiovasc Revasc Med. 2025, 79:45-51. 10.1016\/j.carrev.2025.04.039","journal-title":"Cardiovasc Revasc Med"},{"key":"ref29","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCEP.120.009028","article-title":"Anatomical predictors of pacemaker dependency after transcatheter aortic valve replacement","volume":"14","author":"Nai Fovino L","year":"2021","unstructured":"Nai Fovino L, Cipriani A, Fabris T, et al.. Anatomical predictors of pacemaker dependency after transcatheter aortic valve replacement. Circ Arrhythm Electrophysiol. 2021, 14:e009028. 10.1161\/CIRCEP.120.009028","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"ref30","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcin.2025.08.021","article-title":"30-day and 1-year outcomes of navitor transcatheter aortic valve in low- or intermediate-risk patients","volume":"18","author":"Worthley SG","year":"2025","unstructured":"Worthley SG, Giordano A, Corcione N, et al.. 30-day and 1-year outcomes of navitor transcatheter aortic valve in low- or intermediate-risk patients. JACC Cardiovasc Interv. 2025, 18:2517-27. 10.1016\/j.jcin.2025.08.021","journal-title":"JACC Cardiovasc Interv"},{"key":"ref31","doi-asserted-by":"publisher","DOI":"10.3390\/jcm14165890","article-title":"A comparison of short-term clinical outcomes between the Navitor and Evolut transcatheter aortic valve prostheses","volume":"14","author":"Campanella C","year":"2025","unstructured":"Campanella C, Kaiser K, Voss S, et al.. A comparison of short-term clinical outcomes between the Navitor and Evolut transcatheter aortic valve prostheses. J Clin Med. 2025, 14:5890. 10.3390\/jcm14165890","journal-title":"J Clin Med"},{"key":"ref32","doi-asserted-by":"publisher","DOI":"10.1016\/j.cjca.2023.09.012","article-title":"Impact of prosthesis-patient mismatch after transcatheter aortic valve replacement","volume":"40","author":"Levesque T","year":"2024","unstructured":"Levesque T, Eltchaninoff H, Chabannes R, et al.. Impact of prosthesis-patient mismatch after transcatheter aortic valve replacement. Can J Cardiol. 2024, 40:113-22. 10.1016\/j.cjca.2023.09.012","journal-title":"Can J Cardiol"},{"key":"ref33","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa2312573","article-title":"Self-expanding or balloon-expandable TAVR in patients with a small aortic annulus","volume":"390","author":"Herrmann HC","year":"2024","unstructured":"Herrmann HC, Mehran R, Blackman DJ, et al.. Self-expanding or balloon-expandable TAVR in patients with a small aortic annulus. N Engl J Med. 2024, 390:1959-71. 10.1056\/NEJMoa2312573","journal-title":"N Engl J Med"},{"key":"ref34","doi-asserted-by":"publisher","DOI":"10.1136\/hrt.2005.067363","article-title":"Prosthesis-patient mismatch: definition, clinical impact, and prevention","volume":"92","author":"Pibarot P","year":"2006","unstructured":"Pibarot P, Dumesnil JG. Prosthesis-patient mismatch: definition, clinical impact, and prevention. Heart. 2006, 92:1022-9. 10.1136\/hrt.2005.067363","journal-title":"Heart"},{"key":"ref35","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcmg.2022.07.013","article-title":"Impact of prosthesis-patient mismatch after transcatheter aortic valve\u00a0replacement: meta-analysis of Kaplan-Meier-derived individual patient data","volume":"16","author":"S\u00e1 MP","year":"2023","unstructured":"S\u00e1 MP, Jacquemyn X, Van den Eynde J, et al.. Impact of prosthesis-patient mismatch after transcatheter aortic valve\u00a0replacement: meta-analysis of Kaplan-Meier-derived individual patient data. JACC Cardiovasc Imaging. 2023, 16:298-310. 10.1016\/j.jcmg.2022.07.013","journal-title":"JACC Cardiovasc Imaging"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/488563-efficacy-and-safety-of-navitor-versus-sapien-valves-in-transcatheter-aortic-valve-implantation-a-systematic-review-and-meta-analysis","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,6]],"date-time":"2026-06-06T12:50:19Z","timestamp":1780750219000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/488563-efficacy-and-safety-of-navitor-versus-sapien-valves-in-transcatheter-aortic-valve-implantation-a-systematic-review-and-meta-analysis"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,6]]},"references-count":35,"URL":"https:\/\/doi.org\/10.7759\/cureus.110349","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2026,6,6]]}}}