{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,11]],"date-time":"2026-07-11T10:13:16Z","timestamp":1783764796722,"version":"3.55.0"},"reference-count":7,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,7,11]]},"DOI":"10.7759\/cureus.112450","type":"journal-article","created":{"date-parts":[[2026,7,11]],"date-time":"2026-07-11T09:53:16Z","timestamp":1783763596000},"source":"Crossref","is-referenced-by-count":0,"title":["Paddy Grain as a Rare Cause of Postmenopausal Bleeding: An Unexpected Hysteroscopic Diagnosis"],"prefix":"10.7759","author":[{"given":"Pruthwiraj","family":"Sethi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chandra","family":"Jyoti","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1016\/0020-7292(96)02702-6","article-title":"Removal of an intrauterine foreign body retained for 12 years","volume":"54","author":"Roy KK","year":"1996","unstructured":"Roy KK, Mittal S, Verma A. Removal of an intrauterine foreign body retained for 12 years. Int J Gynaecol Obstet. 1996, 54:185-6. 10.1016\/0020-7292(96)02702-6","journal-title":"Int J Gynaecol Obstet"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1055\/s-2001-19096","article-title":"Chicken bones in the uterus-an exceptional reason for sterility (Article in German)","volume":"123","author":"Hunger C","year":"2001","unstructured":"Hunger C, Ring A. Chicken bones in the uterus-an exceptional reason for sterility (Article in German). Zentralbl Gynakol. 2001, 123:604-6. 10.1055\/s-2001-19096","journal-title":"Zentralbl Gynakol"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejogrb.2011.07.003","article-title":"Minimally invasive approach to cases of lost intra-uterine device: a 7-year experience","volume":"159","author":"Cetinkaya K","year":"2011","unstructured":"Cetinkaya K, Kumtepe Y, Ingec M. Minimally invasive approach to cases of lost intra-uterine device: a 7-year experience. Eur J Obstet Gynecol Reprod Biol. 2011, 159:119-21. 10.1016\/j.ejogrb.2011.07.003","journal-title":"Eur J Obstet Gynecol Reprod Biol"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1007\/s00192-006-0275-7","article-title":"Vesicovaginal fistula resulting from a well-cared-for pessary","volume":"18","author":"Kaaki B","year":"2007","unstructured":"Kaaki B, Mahajan ST. Vesicovaginal fistula resulting from a well-cared-for pessary. Int Urogynecol J Pelvic Floor Dysfunct. 2007, 18:971-3. 10.1007\/s00192-006-0275-7","journal-title":"Int Urogynecol J Pelvic Floor Dysfunct"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1007\/s00192-008-0574-2","article-title":"Complications of neglected vaginal pessaries: case presentation and literature review","volume":"19","author":"Arias BE","year":"2008","unstructured":"Arias BE, Ridgeway B, Barber MD. Complications of neglected vaginal pessaries: case presentation and literature review. Int Urogynecol J Pelvic Floor Dysfunct. 2008, 19:1173-8. 10.1007\/s00192-008-0574-2","journal-title":"Int Urogynecol J Pelvic Floor Dysfunct"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1016\/S0377-1237(10)80053-X","article-title":"A case of intravaginal foreign body","volume":"66","author":"Chopra S","year":"2010","unstructured":"Chopra S, Singh Y, Magon N. A case of intravaginal foreign body. Med J Armed Forces India. 2010, 66:266-8. 10.1016\/S0377-1237(10)80053-X","journal-title":"Med J Armed Forces India"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmig.2008.09.615","article-title":"Hysteroscopic removal of gauze packing inadvertently sutured to the uterine cavity: report of 2 cases","volume":"16","author":"Bettocchi S","year":"2009","unstructured":"Bettocchi S, Di Spiezio Sardo A, Pinto L, Guida M, Castaldi MA, Ceci O, Nappi C. Hysteroscopic removal of gauze packing inadvertently sutured to the uterine cavity: report of 2 cases. J Minim Invasive Gynecol. 2009, 16:88-91. 10.1016\/j.jmig.2008.09.615","journal-title":"J Minim Invasive Gynecol"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/508333-paddy-grain-as-a-rare-cause-of-postmenopausal-bleeding-an-unexpected-hysteroscopic-diagnosis","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,11]],"date-time":"2026-07-11T09:53:16Z","timestamp":1783763596000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/508333-paddy-grain-as-a-rare-cause-of-postmenopausal-bleeding-an-unexpected-hysteroscopic-diagnosis"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,11]]},"references-count":7,"URL":"https:\/\/doi.org\/10.7759\/cureus.112450","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2026,7,11]]}}}