{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,25]],"date-time":"2026-07-25T19:00:35Z","timestamp":1785006035666,"version":"3.55.0"},"reference-count":18,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,7,25]]},"DOI":"10.7759\/cureus.113361","type":"journal-article","created":{"date-parts":[[2026,7,25]],"date-time":"2026-07-25T18:16:54Z","timestamp":1785003414000},"source":"Crossref","is-referenced-by-count":0,"title":["Assessment of the Optic Nerve Sheath Diameter by Bedside Sonography and Its Correlation With the Glasgow Coma Score in the Outcome of Patients With Sepsis-Associated Encephalopathy"],"prefix":"10.7759","author":[{"given":"Kirtikar","family":"Ghorela","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Raju","family":"Shakya","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mukul","family":"Garg","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shivani","family":"Kumawat","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1155\/2019\/2612849","article-title":"Exploring the biomarkers of sepsis-associated encephalopathy (SAE): metabolomics evidence from gas chromatography-mass spectrometry","volume":"2019","author":"Zhu J","year":"2019","unstructured":"Zhu J, Zhang M, Han T, et al.. Exploring the biomarkers of sepsis-associated encephalopathy (SAE): metabolomics evidence from gas chromatography-mass spectrometry. Biomed Res Int. 2019, 2019:2612849. 10.1155\/2019\/2612849","journal-title":"Biomed Res Int"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1186\/cc9035","article-title":"Pathophysiology of septic encephalopathy--an unsolved puzzle","volume":"14","author":"Flierl MA","year":"2010","unstructured":"Flierl MA, Rittirsch D, Huber-Lang MS, Stahel PF. Pathophysiology of septic encephalopathy--an unsolved puzzle. Crit Care. 2010, 14:165. 10.1186\/cc9035","journal-title":"Crit Care"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1017\/s031716710005335x","article-title":"Progress in clinical neurosciences: sepsis-associated encephalopathy: evolving concepts","volume":"30","author":"Wilson JX","year":"2003","unstructured":"Wilson JX, Young GB. Progress in clinical neurosciences: sepsis-associated encephalopathy: evolving concepts. Can J Neurol Sci. 2003, 30:98-105. 10.1017\/s031716710005335x","journal-title":"Can J Neurol Sci"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1007\/s00134-007-0622-2","article-title":"Sepsis-associated delirium","volume":"33","author":"Ebersoldt M","year":"2007","unstructured":"Ebersoldt M, Sharshar T, Annane D. Sepsis-associated delirium. Intensive Care Med. 2007, 33:941-50. 10.1007\/s00134-007-0622-2","journal-title":"Intensive Care Med"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1097\/00003246-200008000-00057","article-title":"Pathophysiology of septic encephalopathy: a review","volume":"28","author":"Papadopoulos MC","year":"2000","unstructured":"Papadopoulos MC, Davies DC, Moss RF, Tighe D, Bennett ED. Pathophysiology of septic encephalopathy: a review. Crit Care Med. 2000, 28:3019-24. 10.1097\/00003246-200008000-00057","journal-title":"Crit Care Med"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.4103\/0972-5229.144015","article-title":"Optic nerve sheath diameter as a marker for evaluation and prognostication of intracranial pressure in Indian patients: an observational study","volume":"18","author":"Shirodkar CG","year":"2014","unstructured":"Shirodkar CG, Rao SM, Mutkule DP, Harde YR, Venkategowda PM, Mahesh MU. Optic nerve sheath diameter as a marker for evaluation and prognostication of intracranial pressure in Indian patients: an observational study. Indian J Crit Care Med. 2014, 18:728-34. 10.4103\/0972-5229.144015","journal-title":"Indian J Crit Care Med"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1007\/s00134-011-2224-2","article-title":"Ultrasonography of optic nerve sheath diameter for detection of raised intracranial pressure: a systematic review and meta-analysis","volume":"37","author":"Dubourg J","year":"2011","unstructured":"Dubourg J, Javouhey E, Geeraerts T, Messerer M, Kassai B. Ultrasonography of optic nerve sheath diameter for detection of raised intracranial pressure: a systematic review and meta-analysis. Intensive Care Med. 2011, 37:1059-68. 10.1007\/s00134-011-2224-2","journal-title":"Intensive Care Med"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1007\/s00134-018-5305-7","article-title":"Optic nerve sheath diameter measured sonographically as non-invasive estimator of intracranial pressure: a systematic review and meta-analysis","volume":"44","author":"Robba C","year":"2018","unstructured":"Robba C, Santori G, Czosnyka M, et al.. Optic nerve sheath diameter measured sonographically as non-invasive estimator of intracranial pressure: a systematic review and meta-analysis. Intensive Care Med. 2018, 44:1284-94. 10.1007\/s00134-018-5305-7","journal-title":"Intensive Care Med"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1007\/BF01709751","article-title":"The SOFA (Sepsis-related Organ Failure Assessment) score to describe organ dysfunction\/failure. On behalf of the Working Group on Sepsis-Related Problems of the European Society of Intensive Care Medicine","volume":"22","author":"Vincent JL","year":"1996","unstructured":"Vincent JL, Moreno R, Takala J, et al.. The SOFA (Sepsis-related Organ Failure Assessment) score to describe organ dysfunction\/failure. On behalf of the Working Group on Sepsis-Related Problems of the European Society of Intensive Care Medicine. Intensive Care Med. 1996, 22:707-10. 10.1007\/BF01709751","journal-title":"Intensive Care Med"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1097\/00003465-198603000-00013","article-title":"APACHE II: a severity of disease classification system","volume":"13","author":"Knaus WA","year":"1985","unstructured":"Knaus WA, Draper EA, Wagner DP, Zimmerman JE. APACHE II: a severity of disease classification system. Dim Crit Care Nursing. 1985, 13:818-29. 10.1097\/00003465-198603000-00013","journal-title":"Dim Crit Care Nursing"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1016\/s0140-6736(74)91639-0","article-title":"Assessment of coma and impaired consciousness. A practical scale","volume":"2","author":"Teasdale G","year":"1974","unstructured":"Teasdale G, Jennett B. Assessment of coma and impaired consciousness. A practical scale. Lancet. 1974, 2:81-4. 10.1016\/s0140-6736(74)91639-0","journal-title":"Lancet"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1258\/ult.2010.1000","article-title":"Guidelines for the Safe Use of Diagnostic Ultrasound Equipment","year":"2010","unstructured":"Guidelines for the Safe Use of Diagnostic Ultrasound Equipment.  British Medical Ultrasound Society, 2010. 10.1258\/ult.2010.1000"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1186\/s13054-020-02959-7","article-title":"Bedside ultrasound measurement of optic nerve sheath diameter in patients with sepsis: a prospective observational study","volume":"24","author":"Yang Z","year":"2020","unstructured":"Yang Z, Qin C, Zhang S, Liu S, Sun T. Bedside ultrasound measurement of optic nerve sheath diameter in patients with sepsis: a prospective observational study. Crit Care. 2020, 24:235. 10.1186\/s13054-020-02959-7","journal-title":"Crit Care"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0117939","article-title":"Optimal optic nerve sheath diameter threshold for the identification of elevated opening pressure on lumbar puncture in a Chinese population","volume":"10","author":"Wang L","year":"2015","unstructured":"Wang L, Feng L, Yao Y, Wang Y, Chen Y, Feng J, Xing Y. Optimal optic nerve sheath diameter threshold for the identification of elevated opening pressure on lumbar puncture in a Chinese population. PLoS One. 2015, 10:e0117939. 10.1371\/journal.pone.0117939","journal-title":"PLoS One"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.3390\/ijerph17103656","article-title":"Ultrasonic assessment of optic nerve sheath diameter in patients at risk of sepsis-associated brain dysfunction: a preliminary report","volume":"17","author":"Czempik PF","year":"2020","unstructured":"Czempik PF, G\u0105siorek J, B\u0105k A, Krzych \u0141J. Ultrasonic assessment of optic nerve sheath diameter in patients at risk of sepsis-associated brain dysfunction: a preliminary report. Int J Environ Res Public Health. 2020, 17:3656. 10.3390\/ijerph17103656","journal-title":"Int J Environ Res Public Health"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.5492\/wjccm.v12.i1.10","article-title":"Bedside ultrasonography of optic nerve sheath diameter for detection of raised intracranial pressure in nontraumatic neuro-critically ill patients","volume":"12","author":"Bhide M","year":"2023","unstructured":"Bhide M, Singh O, Juneja D, Goel A. Bedside ultrasonography of optic nerve sheath diameter for detection of raised intracranial pressure in nontraumatic neuro-critically ill patients. World J Crit Care Med. 2023, 12:10-7. 10.5492\/wjccm.v12.i1.10","journal-title":"World J Crit Care Med"},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.1016\/j.jns.2015.12.032","article-title":"Sonographic assessment of the optic nerve sheath diameter in the diagnosis of idiopathic intracranial hypertension","volume":"361","author":"del Saz-Saucedo P","year":"2016","unstructured":"del Saz-Saucedo P, Redondo-Gonz\u00e1lez O, Mateu-Mateu \u00c1, Huertas-Arroyo R, Garc\u00eda-Ruiz R, Botia-Paniagua E. Sonographic assessment of the optic nerve sheath diameter in the diagnosis of idiopathic intracranial hypertension. J Neurol Sci. 2016, 361:122-7. 10.1016\/j.jns.2015.12.032","journal-title":"J Neurol Sci"},{"key":"ref18","doi-asserted-by":"publisher","DOI":"10.4103\/aian.AIAN_51_20","article-title":"Bedside ultrasonographic assessment of optic nerve sheath diameter as a means of detecting raised intracranial pressure in neuro-trauma patients: a cross-sectional study","volume":"24","author":"Kaur A","year":"2021","unstructured":"Kaur A, Gautam PL, Sharma S, Singh VP, Sharma S. Bedside ultrasonographic assessment of optic nerve sheath diameter as a means of detecting raised intracranial pressure in neuro-trauma patients: a cross-sectional study. Ann Indian Acad Neurol. 2021, 24:63-8. 10.4103\/aian.AIAN_51_20","journal-title":"Ann Indian Acad Neurol"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/511412-assessment-of-the-optic-nerve-sheath-diameter-by-bedside-sonography-and-its-correlation-with-the-glasgow-coma-score-in-the-outcome-of-patients-with-sepsis-associated-encephalopathy","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,25]],"date-time":"2026-07-25T18:16:55Z","timestamp":1785003415000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/511412-assessment-of-the-optic-nerve-sheath-diameter-by-bedside-sonography-and-its-correlation-with-the-glasgow-coma-score-in-the-outcome-of-patients-with-sepsis-associated-encephalopathy"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,25]]},"references-count":18,"URL":"https:\/\/doi.org\/10.7759\/cureus.113361","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2026,7,25]]}}}