{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,4]],"date-time":"2026-08-04T21:04:03Z","timestamp":1785877443195,"version":"3.56.0"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2021,1,13]]},"DOI":"10.7759\/cureus.12684","type":"journal-article","created":{"date-parts":[[2021,1,13]],"date-time":"2021-01-13T18:25:59Z","timestamp":1610562359000},"source":"Crossref","is-referenced-by-count":3,"title":["Effect of Multileaf Collimator Leaf Position Error Determined by Picket Fence Test on Gamma Index Value in Patient-Specific Quality Assurance of Volumetric-Modulated Arc Therapy Plans"],"prefix":"10.7759","author":[{"given":"Cemile","family":"Ceylan","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Serpil","family":"Yondem Inal","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elif","family":"Senol","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Berrin","family":"Yilmaz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sevim","family":"Sahin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1259\/bjr\/22373346","article-title":"Volumetric modulated arc therapy: a review of current literature and clinical use in practice","volume":"84","author":"Teoh M","year":"2011","unstructured":"Teoh M, Clark CH, Wood K, Whitaker S, Nisbet A. Volumetric modulated arc therapy: a review of current literature and clinical use in practice. Br J Radiol. 2011, 84:967-996. 10.1259\/bjr\/22373346","journal-title":"Br J Radiol"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1016\/j.radonc.2005.03.009","article-title":"IMRT with the sliding window: comparison of the static and dynamic methods. Dosimetric and spectral analysis","volume":"75","author":"Nicolini G","year":"2005","unstructured":"Nicolini G, Fogliata A, Cozzi L. IMRT with the sliding window: comparison of the static and dynamic methods. Dosimetric and spectral analysis. Radiother Oncol. 2005, 75:112-119. 10.1016\/j.radonc.2005.03.009","journal-title":"Radiother Oncol"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1118\/1.1410123","article-title":"Comprehensive quality assurance for the delivery of intensity modulated radiotherapy with a multileaf collimator used in the dynamic mode","volume":"28","author":"LoSasso T","year":"2001","unstructured":"LoSasso T, Chui CS, Ling CC. Comprehensive quality assurance for the delivery of intensity modulated radiotherapy with a multileaf collimator used in the dynamic mode. Med Phys. 2001, 28:2209-2219. 10.1118\/1.1410123","journal-title":"Med Phys"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/47\/16\/314","article-title":"Dosimetric considerations for validation of a sequential IMRT process with a commercial treatment planning system","volume":"47","author":"Cadman P","year":"2002","unstructured":"Cadman P, Bassalow R, Sidhu NP, Ibbott G, Nelson A. Dosimetric considerations for validation of a sequential IMRT process with a commercial treatment planning system. Phys Med Biol. 2002, 47:3001-3010. 10.1088\/0031-9155\/47\/16\/314","journal-title":"Phys Med Biol"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1118\/1.3134244","article-title":"Tolerances on MLC leaf position accuracy for IMRT delivery with a dynamic MLC","volume":"36","author":"Rangel A","year":"2009","unstructured":"Rangel A, Dunscombe P. Tolerances on MLC leaf position accuracy for IMRT delivery with a dynamic MLC. Med Phys. 2009, 36:3304-3309. 10.1118\/1.3134244","journal-title":"Med Phys"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1016\/j.radonc.2010.06.013","article-title":"Clinical significance of multi-leaf collimator positional errors for volumetric modulated arc therapy","volume":"97","author":"Oliver M","year":"2010","unstructured":"Oliver M, Gagne I, Bush K, Zavgorodni S, Ansbacher W, Beckham W. Clinical significance of multi-leaf collimator positional errors for volumetric modulated arc therapy. Radiother Oncol. 2010, 97:554-560. 10.1016\/j.radonc.2010.06.013","journal-title":"Radiother Oncol"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1118\/1.4915541","article-title":"Determination of the optimal tolerance for MLC positioning in sliding window and VMAT techniques","volume":"42","author":"Hernandez V","year":"2015","unstructured":"Hernandez V, Abella R, Calvo JF, Jurado\u2010Bruggemann D, Sancho I, Carrasco P. Determination of the optimal tolerance for MLC positioning in sliding window and VMAT techniques. Med Phys. 2015, 42:1911-1916. 10.1118\/1.4915541","journal-title":"Med Phys"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1118\/1.3690464","article-title":"RapidArc patient specific mechanical delivery accuracy under extreme mechanical limits using linac log files","volume":"39","author":"Wijesooriya K","year":"2012","unstructured":"Wijesooriya K, Aliotta E, Benedict S, Read P, Rich T, Larner J. RapidArc patient specific mechanical delivery accuracy under extreme mechanical limits using linac log files. Med Phys. 2012, 39:1846-1853. 10.1118\/1.3690464","journal-title":"Med Phys"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1118\/1.598381","article-title":"Physical and dosimetric aspects of a multileaf collimation system used in the dynamic mode for implementing intensity modulated radiotherapy","volume":"25","author":"LoSasso T","year":"1998","unstructured":"LoSasso T, Chui CS, Ling CC. Physical and dosimetric aspects of a multileaf collimation system used in the dynamic mode for implementing intensity modulated radiotherapy. Med Phys. 1998, 25:1919-1927. 10.1118\/1.598381","journal-title":"Med Phys"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/45\/5\/310","article-title":"Requirements for leaf position accuracy for dynamic multileaf collimation","volume":"45","author":"Budgell GJ","year":"2000","unstructured":"Budgell GJ, Mott JH, Williams PC, Brown KJ. Requirements for leaf position accuracy for dynamic multileaf collimation. Phys Med Biol. 2000, 45:1211-1227. 10.1088\/0031-9155\/45\/5\/310","journal-title":"Phys Med Biol"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1118\/1.3190392","article-title":"Task Group 142 report: quality assurance of medical accelerators","volume":"36","author":"Klein EE","year":"2009","unstructured":"Klein EE, Hanley J, Bayouth J, et al.. Task Group 142 report: quality assurance of medical accelerators. Med Phys. 2009, 36:4197-4212. 10.1118\/1.3190392","journal-title":"Med Phys"},{"key":"ref12","article-title":"Guidelines for the verification of IMRT","author":"Alber M","year":"2008","unstructured":"Alber M, Broggi S, Wagter CD, et al..  Guidelines for the verification of IMRT. ESTRO Booklet No. 9. Mijnheer G (ed): ESTRO, Brussels; 2008. 89-106."},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1186\/1748-717X-9-176","article-title":"A multi-institution evaluation of MLC log files and performance in IMRT delivery","volume":"9","author":"Kerns JR","year":"2014","unstructured":"Kerns JR, Childress N, Kry SF. A multi-institution evaluation of MLC log files and performance in IMRT delivery. Radiat Oncol. 2014, 9:176-110. 10.1186\/1748-717X-9-176","journal-title":"Radiat Oncol"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1118\/1.4949002","article-title":"A clinically observed discrepancy between image\u2010based and log\u2010based MLC positions","volume":"43","author":"Neal B","year":"2016","unstructured":"Neal B, Ahmed M, Kathuria K, Wijesooriya K, Siebers J. A clinically observed discrepancy between image\u2010based and log\u2010based MLC positions. Med Phys. 2016, 43:2933-2935. 10.1118\/1.4949002","journal-title":"Med Phys"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/49\/8\/010","article-title":"Quantitative measurement of MLC leaf displacements using an electronic portal image device","volume":"49","author":"Yang Y","year":"2004","unstructured":"Yang Y, Xing L. Quantitative measurement of MLC leaf displacements using an electronic portal image device. Phys Med Biol. 2004, 49:1521-1533. 10.1088\/0031-9155\/49\/8\/010","journal-title":"Phys Med Biol"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejmp.2011.06.046","article-title":"QA of dynamic MLC based on EPID portal dosimetry","volume":"28","author":"Richart J","year":"2011","unstructured":"Richart J, Pujades MC, Perez-Calatayud J, Ballester F, Rodriguez S, Santos M. QA of dynamic MLC based on EPID portal dosimetry. Physica Medica Eur J MedPhys. 2011, 28:262-268. 10.1016\/j.ejmp.2011.06.046","journal-title":"Physica Medica Eur J MedPhys"},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.1118\/1.4752207","article-title":"EPID\u2010based verification of the MLC performance for dynamic IMRT and VMAT","volume":"39","author":"Rowshanfarzad P","year":"2012","unstructured":"Rowshanfarzad P, Sabet M, Barnes MP, O'Connor DJ, Greer PB. EPID\u2010based verification of the MLC performance for dynamic IMRT and VMAT. Med Phys. 2012, 39:6192-6207. 10.1118\/1.4752207","journal-title":"Med Phys"},{"key":"ref18","doi-asserted-by":"publisher","DOI":"10.1120\/jacmp.v17i2.5474","article-title":"Evaluation of MLC leaf positioning accuracy for static and dynamic IMRT treatments using DAVID in vivo dosimetric system","volume":"17","author":"Karagoz G","year":"2016","unstructured":"Karagoz G, Zorlu F, Yeginer M, Yildiz D, Ozyigit G. Evaluation of MLC leaf positioning accuracy for static and dynamic IMRT treatments using DAVID in vivo dosimetric system. J Appl Clin Med Phys. 2016, 17:14-23. 10.1120\/jacmp.v17i2.5474","journal-title":"J Appl Clin Med Phys"},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.1120\/jacmp.v14i2.4136","article-title":"Beam modeling and VMAT performance with the Agility 160-leaf multileaf collimator","volume":"14","author":"Bedford JL","year":"2013","unstructured":"Bedford JL, Thomas MDR, Smyth G. Beam modeling and VMAT performance with the Agility 160-leaf multileaf collimator. J Appl Clin Med Phys. 2013, 14:172-185. 10.1120\/jacmp.v14i2.4136","journal-title":"J Appl Clin Med Phys"},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.1118\/1.597699","article-title":"Testing of dynamic multileaf collimation","volume":"23","author":"Chui CS","year":"1996","unstructured":"Chui CS, Spirou S, LoSasso T. Testing of dynamic multileaf collimation. Med Phys. 1996, 23:635-641. 10.1118\/1.597699","journal-title":"Med Phys"},{"key":"ref21","doi-asserted-by":"publisher","DOI":"10.1017\/S1460396918000705","article-title":"Evaluating the dosimetric consequences of MLC leaf positioning errors in dynamic IMRT treatments","volume":"8","author":"Agarwal A","year":"2019","unstructured":"Agarwal A, Rastogi N, Maria Das KJ, Yoganathan SA, Udayakumar D, Naresh R, Kumar S. Evaluating the dosimetric consequences of MLC leaf positioning errors in dynamic IMRT treatments. J Radiother Pract. 2019, 8:225-231. 10.1017\/S1460396918000705","journal-title":"J Radiother Pract"},{"key":"ref22","doi-asserted-by":"publisher","DOI":"10.1186\/1748-717X-9-167","article-title":"The sensitivity of gamma-index method to the positioning errors of high-definition MLC in patient-specific VMAT QA for SBRT","volume":"9","author":"Kim J","year":"2018","unstructured":"Kim J, Park SY, Kim J, Kim JH, Ye SJ, Park JM. The sensitivity of gamma-index method to the positioning errors of high-definition MLC in patient-specific VMAT QA for SBRT. Radiat Oncol. 2018, 9:167-128. 10.1186\/1748-717X-9-167","journal-title":"Radiat Oncol"},{"key":"ref23","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.12102","article-title":"A quantitative method to the analysis of MLC leaf position and speed based on EPID and EBT3 film for dynamic IMRT treatment with different types of MLC","volume":"18","author":"Li Y","year":"2017","unstructured":"Li Y, Chen L, Zhu J, Wang B, Liu X. A quantitative method to the analysis of MLC leaf position and speed based on EPID and EBT3 film for dynamic IMRT treatment with different types of MLC. J Appl Clin Med Phys. 2017, 18:106-115. 10.1002\/acm2.12102","journal-title":"J Appl Clin Med Phys"},{"key":"ref24","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.12288","article-title":"Comparison of MLC error sensitivity of various commercial devices for VMAT pre-treatment quality assurance","volume":"19","author":"Saito M","year":"2018","unstructured":"Saito M, Sano N, Shibata Y, et al.. Comparison of MLC error sensitivity of various commercial devices for VMAT pre-treatment quality assurance. J Appl Clin Med Phys. 2018, 19:87-93. 10.1002\/acm2.12288","journal-title":"J Appl Clin Med Phys"},{"key":"ref25","doi-asserted-by":"crossref","DOI":"10.1002\/acm2.12148","article-title":"Sensitivity of array detector measurements in determining shifts of MLC leaf positions","volume":"18","author":"Shang Q","year":"2017","unstructured":"Shang Q, Godley A, Huang L, Qi P, Xia P. Sensitivity of array detector measurements in determining shifts of MLC leaf positions. J Appl Clin Med Phys. 2017, 18:80-88.","journal-title":"J Appl Clin Med Phys"},{"key":"ref26","doi-asserted-by":"publisher","DOI":"10.1120\/jacmp.v16i5.5515","article-title":"Analysis of direct clinical consequences of MLC positional errors in volumetric-modulated arc therapy using 3D dosimetry system","volume":"16","author":"Nithiyanantham K","year":"2015","unstructured":"Nithiyanantham K, Mani GK, Subramani V, Mueller L, Palaniappan KK, Kataria T. Analysis of direct clinical consequences of MLC positional errors in volumetric-modulated arc therapy using 3D dosimetry system. J Appl Clin Med Phys. 2015, 16:296-305. 10.1120\/jacmp.v16i5.5515","journal-title":"J Appl Clin Med Phys"},{"key":"ref27","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/59\/9\/N49","article-title":"Monitoring daily MLC positional errors using trajectory log files and EPID measurements for IMRT and VMAT deliveries","volume":"59","author":"Agnew A","year":"2014","unstructured":"Agnew A, Agnew CE, Grattan MW, Hounsell AR, McGarry CK. Monitoring daily MLC positional errors using trajectory log files and EPID measurements for IMRT and VMAT deliveries. Phys Med Biol. 2014, 59:49-63. 10.1088\/0031-9155\/59\/9\/N49","journal-title":"Phys Med Biol"},{"key":"ref28","doi-asserted-by":"publisher","DOI":"10.1088\/1742-6596\/489\/1\/012071","article-title":"Evaluation of the ability of a 2D ionisation chamber array and an EPID to detect systematic delivery errors in IMRT plans","volume":"489","author":"Bawazeer O","year":"2014","unstructured":"Bawazeer O, Gray A, Arumugam S, Vial P, Thwaites D, Descallar J, Holloway L. Evaluation of the ability of a 2D ionisation chamber array and an EPID to detect systematic delivery errors in IMRT plans. J Phys Conf Ser. 2014, 489:1-5. 10.1088\/1742-6596\/489\/1\/012071","journal-title":"J Phys Conf Ser"},{"key":"ref29","doi-asserted-by":"publisher","DOI":"10.1080\/16878507.2019.1618080","article-title":"Sensitivity evaluation of two commercial quality assurance systems to organ-dose variations of patient-specific VMAT plans","volume":"1","author":"Oderinde OM","year":"2019","unstructured":"Oderinde OM, Du Plessis F. Sensitivity evaluation of two commercial quality assurance systems to organ-dose variations of patient-specific VMAT plans. J Radiat Res Appl Sci. 2019, 1:132-139. 10.1080\/16878507.2019.1618080","journal-title":"J Radiat Res Appl Sci"},{"key":"ref30","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/61\/23\/8340","article-title":"Automatic detection of MLC relative position errors for VMAT using the EPID- based picket fence test","volume":"61","author":"Christophides D","year":"2016","unstructured":"Christophides D, Davies A, Fleckney M. Automatic detection of MLC relative position errors for VMAT using the EPID- based picket fence test. Phys Med Biol. 2016, 61:8340-8359. 10.1088\/0031-9155\/61\/23\/8340","journal-title":"Phys Med Biol"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/49048-effect-of-multileaf-collimator-leaf-position-error-determined-by-picket-fence-test-on-gamma-index-value-in-patient-specific-quality-assurance-of-volumetric-modulated-arc-therapy-plans","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,2,9]],"date-time":"2024-02-09T19:28:14Z","timestamp":1707506894000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/49048-effect-of-multileaf-collimator-leaf-position-error-determined-by-picket-fence-test-on-gamma-index-value-in-patient-specific-quality-assurance-of-volumetric-modulated-arc-therapy-plans"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,1,13]]},"references-count":30,"URL":"https:\/\/doi.org\/10.7759\/cureus.12684","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2021,1,13]]}}}