{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,2,10]],"date-time":"2024-02-10T00:16:35Z","timestamp":1707524195722},"reference-count":49,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2021,1,28]]},"DOI":"10.7759\/cureus.12969","type":"journal-article","created":{"date-parts":[[2021,1,28]],"date-time":"2021-01-28T17:32:37Z","timestamp":1611855157000},"source":"Crossref","is-referenced-by-count":1,"title":["Plastics in Total Knee Replacement: Processing to Performance"],"prefix":"10.7759","author":[{"given":"Naga","family":"Cheppalli","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sreenivasulu","family":"Metikala","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Benjamin S","family":"Albertson","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kenneth","family":"Yaw","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1097\/01.blo.0000238813.95035.1b","article-title":"The cellular and molecular biology of periprosthetic osteolysis","volume":"454","author":"Purdue PE","year":"2007","unstructured":"Purdue PE, Koulouvaris P, Potter HG, Nestor BJ, Sculco TP. The cellular and molecular biology of periprosthetic osteolysis. Clin Orthop Relat Res. 2007, 454:251-61. 10.1097\/01.blo.0000238813.95035.1b","journal-title":"Clin Orthop Relat Res"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1097\/01.blo.0000148783.20469.4c","article-title":"Wear, debris, and biologic activity of cross-linked polyethylene in the knee: benefits and potential concerns","volume":"428","author":"Fisher J","year":"2004","unstructured":"Fisher J, McEwen HMJ, Tipper JL, et al.. Wear, debris, and biologic activity of cross-linked polyethylene in the knee: benefits and potential concerns. Clin Orthop Relat Res. 2004, 428:114-9. 10.1097\/01.blo.0000148783.20469.4c","journal-title":"Clin Orthop Relat Res"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1016\/j.orthres.2005.02.017.1100230602","article-title":"Activation of NF\u2010KB signalling and TNF\u03b1\u2010expression in THP\u20101 macrophages by TiAlV\u2010 and polyethylene\u2010wear particles","volume":"23","author":"Baumann B","year":"2005","unstructured":"Baumann B, Seufert J, Jakob F, N\u00f6th U, Rolf O, Eulert J, Rader CP. Activation of NF\u2010KB signalling and TNF\u03b1\u2010expression in THP\u20101 macrophages by TiAlV\u2010 and polyethylene\u2010wear particles. J Orthop Res. 2005, 23:1241-8. 10.1016\/j.orthres.2005.02.017.1100230602","journal-title":"J Orthop Res"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.3109\/17453674.2010.501747","article-title":"Younger age increases the risk of early prosthesis failure following primary total knee replacement for osteoarthritis: a follow-up study of 32,019 total knee replacements in the Finnish Arthroplasty Register","volume":"81","author":"Julin J","year":"2010","unstructured":"Julin J, J\u00e4msen E, Puolakka T, Konttinen YT, Moilanen T. Younger age increases the risk of early prosthesis failure following primary total knee replacement for osteoarthritis: a follow-up study of 32,019 total knee replacements in the Finnish Arthroplasty Register. Acta Orthop. 2010, 81:413-9. 10.3109\/17453674.2010.501747","journal-title":"Acta Orthop"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1055\/s-0035-1551833","article-title":"Polyethylene wear in knee arthroplasty","volume":"28","author":"Chakravarty R","year":"2015","unstructured":"Chakravarty R, Elmallah RDK, Cherian JJ, Kurtz SM, Mont MA. Polyethylene wear in knee arthroplasty. J Knee Surg. 2015, 28:370-5. 10.1055\/s-0035-1551833","journal-title":"J Knee Surg"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1007\/s11999-017-5494-3","article-title":"Current total knee designs: does baseplate roughness or locking mechanism design affect polyethylene backside wear?","volume":"475","author":"Sisko ZW","year":"2017","unstructured":"Sisko ZW, Teeter MG, Lanting BA, et al.. Current total knee designs: does baseplate roughness or locking mechanism design affect polyethylene backside wear?. Clin Orthop Relat Res. 2017, 475:2970-80. 10.1007\/s11999-017-5494-3","journal-title":"Clin Orthop Relat Res"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1055\/s-0031-1275390","article-title":"The influence of material and design on total knee replacement wear","volume":"24","author":"Essner A","year":"2011","unstructured":"Essner A, Herrera L, Hughes P, Kester M. The influence of material and design on total knee replacement wear. J Knee Surg. 2011, 24:9-18. 10.1055\/s-0031-1275390","journal-title":"J Knee Surg"},{"key":"ref8","article-title":"UHMWPE Biomaterials Handbook: Ultra High Molecular Weight Polyethylene in Total Joint Replacement and Medical Devices","author":"Kurtz SM","year":"2015","unstructured":"Kurtz SM. UHMWPE Biomaterials Handbook: Ultra High Molecular Weight Polyethylene in Total Joint Replacement and Medical Devices. Kurtz SM (ed): William Andrew, Massachusetts; 2015."},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1007\/s10195-008-0038-y","article-title":"UHMWPE for arthroplasty: past or future?","volume":"10","author":"Brach del Prever EM","year":"2009","unstructured":"Brach del Prever EM, Bistolfi A, Bracco P, Costa L. UHMWPE for arthroplasty: past or future?. J Orthopaed Traumatol. 2009, 10:1-8. 10.1007\/s10195-008-0038-y","journal-title":"J Orthopaed Traumatol"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.b.30454","article-title":"Oxidation and oxidation potential in contemporary packaging for polyethylene total joint replacement components","volume":"78","author":"Costa L","year":"2006","unstructured":"Costa L, Bracco P, Brach Del Prever EM, Kurtz SM, Gallinaro P. Oxidation and oxidation potential in contemporary packaging for polyethylene total joint replacement components. J Biomed Mater Res B Appl Biomater. 2006, 78:20-6. 10.1002\/jbm.b.30454","journal-title":"J Biomed Mater Res B Appl Biomater"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1016\/j.biomaterials.2004.03.022","article-title":"Deformation, yielding, fracture and fatigue behavior of conventional and highly cross-linked ultra high molecular weight polyethylene","volume":"26","author":"Pruitt LA","year":"2005","unstructured":"Pruitt LA. Deformation, yielding, fracture and fatigue behavior of conventional and highly cross-linked ultra high molecular weight polyethylene. Biomaterials. 2005, 26:905-15. 10.1016\/j.biomaterials.2004.03.022","journal-title":"Biomaterials"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1016\/S0142-9612(98)00140-9","article-title":"Polyethylene particles of a \u2018critical size\u2019 are necessary for the induction of cytokines by macrophages in vitro","volume":"19","author":"Green TR","year":"1998","unstructured":"Green TR, Fisher J, Stone M, Wroblewski BM, Ingham E. Polyethylene particles of a \u2018critical size\u2019 are necessary for the induction of cytokines by macrophages in vitro. Biomaterials. 1998, 19:2297-302. 10.1016\/S0142-9612(98)00140-9","journal-title":"Biomaterials"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1243\/0954411001535219","article-title":"Biological reactions to wear debris in total joint replacement","volume":"214","author":"Ingham E","year":"2000","unstructured":"Ingham E, Fisher J. Biological reactions to wear debris in total joint replacement. Proc Inst Mech Eng H. 2000, 214:21-37. 10.1243\/0954411001535219","journal-title":"Proc Inst Mech Eng H"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1016\/S0883-5403(03)00293-6","article-title":"Optical analysis of surface changes on early retrievals of highly cross-linked and conventional polyethylene tibial inserts","volume":"18","author":"Muratoglu OK","year":"2003","unstructured":"Muratoglu OK, Ruberti J, Melotti S, Spiegelberg SH, Greenbaum ES, Harris WH. Optical analysis of surface changes on early retrievals of highly cross-linked and conventional polyethylene tibial inserts. J Arthroplasty. 2003, 18:42-7. 10.1016\/S0883-5403(03)00293-6","journal-title":"J Arthroplasty"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.1016\/j.knee.2018.05.005","article-title":"Five cases of tibial post fracture in posterior stabilized total knee arthroplasty using Prolong highly cross-linked polyethylene","volume":"25","author":"Diamond OJ","year":"2018","unstructured":"Diamond OJ, Howard L, Masri B. Five cases of tibial post fracture in posterior stabilized total knee arthroplasty using Prolong highly cross-linked polyethylene. Knee. 2018, 25:657-62. 10.1016\/j.knee.2018.05.005","journal-title":"Knee"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinbiomech.2009.04.007","article-title":"Wear of contemporary total knee replacements - a knee simulator study of six current designs","volume":"24","author":"Utzschneider S","year":"2009","unstructured":"Utzschneider S, Harrasser N, Schroeder C, Mazoochian F, Jansson V. Wear of contemporary total knee replacements - a knee simulator study of six current designs. Clin Biomech. 2009, 24:583-8. 10.1016\/j.clinbiomech.2009.04.007","journal-title":"Clin Biomech"},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.1016\/j.artd.2019.12.005","article-title":"Early failure of sequentially annealed polyethylene in total knee arthroplasty","volume":"6","author":"Sonn KA","year":"2020","unstructured":"Sonn KA, Meneghini RM. Early failure of sequentially annealed polyethylene in total knee arthroplasty. Arthroplast Today. 2020, 6:18-22. 10.1016\/j.artd.2019.12.005","journal-title":"Arthroplast Today"},{"key":"ref18","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2007.05.007","article-title":"A highly crosslinked UHMWPE for CR and PS total knee arthroplasties","volume":"23","author":"Wang A","year":"2008","unstructured":"Wang A, Yau SS, Essner A, Herrera L, Manley M, Dumbleton J. A highly crosslinked UHMWPE for CR and PS total knee arthroplasties. J Arthroplasty. 2008, 23:559-66. 10.1016\/j.arth.2007.05.007","journal-title":"J Arthroplasty"},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2017.10.005","article-title":"Is cross-linked polyethylene an improvement over conventional ultra-high molecular weight polyethylene in total knee arthroplasty?","volume":"33","author":"Boyer B","year":"2018","unstructured":"Boyer B, Bordini B, Caputo D, Neri T, Stea S, Toni A. Is cross-linked polyethylene an improvement over conventional ultra-high molecular weight polyethylene in total knee arthroplasty?. J Arthroplasty. 2018, 33:908-14. 10.1016\/j.arth.2017.10.005","journal-title":"J Arthroplasty"},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.1007\/s00264-018-4237-8","article-title":"Effects of vitamin E incorporation in polyethylene on oxidative degradation, wear rates, immune response, and infections in total joint arthroplasty: a review of the current literature","volume":"43","author":"Lambert B","year":"2019","unstructured":"Lambert B, Neut D, van der Veen HC, Bulstra SK. Effects of vitamin E incorporation in polyethylene on oxidative degradation, wear rates, immune response, and infections in total joint arthroplasty: a review of the current literature. Int Orthop. 2019, 43:1549-57. 10.1007\/s00264-018-4237-8","journal-title":"Int Orthop"},{"key":"ref21","doi-asserted-by":"publisher","DOI":"10.1016\/j.biomaterials.2017.07.028","article-title":"Effects of vitamin E-diffused highly cross-linked UHMWPE particles on inflammation, apoptosis and immune response against S. aureus","volume":"143","author":"Chen W","year":"2017","unstructured":"Chen W, Bichara DA, Suhardi J, Sheng P, Muratoglu OK. Effects of vitamin E-diffused highly cross-linked UHMWPE particles on inflammation, apoptosis and immune response against S. aureus. Biomaterials. 2017, 143:46-56. 10.1016\/j.biomaterials.2017.07.028","journal-title":"Biomaterials"},{"key":"ref22","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.96B4.32895","article-title":"Interplay between surface properties of standard, vitamin E blended and oxidised ultra high molecular weight polyethylene used in total joint replacement and adhesion of Staphylococcus aureus and Escherichia coli","volume":"96","author":"Banche G","year":"2014","unstructured":"Banche G, Allizond V, Bracco P, et al.. Interplay between surface properties of standard, vitamin E blended and oxidised ultra high molecular weight polyethylene used in total joint replacement and adhesion of Staphylococcus aureus and Escherichia coli. Bone Joint J. 2014, 96:497-501. 10.1302\/0301-620X.96B4.32895","journal-title":"Bone Joint J"},{"key":"ref23","doi-asserted-by":"publisher","DOI":"10.1007\/s00264-010-1161-y","article-title":"Vitamin E diffused, highly crosslinked UHMWPE: a review","volume":"35","author":"Oral E","year":"2011","unstructured":"Oral E, Muratoglu OK. Vitamin E diffused, highly crosslinked UHMWPE: a review. Int Orthop. 2011, 35:215-23. 10.1007\/s00264-010-1161-y","journal-title":"Int Orthop"},{"key":"ref24","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2011.03.024","article-title":"Does vitamin E-stabilized ultrahigh-molecular-weight polyethylene address concerns of cross-linked polyethylene in total knee arthroplasty?","volume":"27","author":"Haider H","year":"2012","unstructured":"Haider H, Weisenburger JN, Kurtz SM, Rimnac CM, Freedman J, Schroeder DW, Garvin KL. Does vitamin E-stabilized ultrahigh-molecular-weight polyethylene address concerns of cross-linked polyethylene in total knee arthroplasty?. J Arthroplasty. 2012, 27:461-9. 10.1016\/j.arth.2011.03.024","journal-title":"J Arthroplasty"},{"key":"ref25","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2014.03.044","article-title":"Vitamin E-diffused highly cross-linked UHMWPE particles induce less osteolysis compared to highly cross-linked virgin UHMWPE particles in vivo","volume":"29","author":"Bichara DA","year":"2014","unstructured":"Bichara DA, Malchau E, Sillesen NH, Cakmak S, Nielsen GP, Muratoglu OK. Vitamin E-diffused highly cross-linked UHMWPE particles induce less osteolysis compared to highly cross-linked virgin UHMWPE particles in vivo. J Arthroplasty. 2014, 29:232-7. 10.1016\/j.arth.2014.03.044","journal-title":"J Arthroplasty"},{"key":"ref26","doi-asserted-by":"publisher","DOI":"10.1007\/s00264-018-4237-8","article-title":"Effects of vitamin E incorporation in polyethylene on oxidative degradation, wear rates, immune response, and infections in total joint arthroplasty: a review of the current literature","volume":"43","author":"Lambert B","year":"2019","unstructured":"Lambert B, Neut D, van der Veen HC, Bulstra SK. Effects of vitamin E incorporation in polyethylene on oxidative degradation, wear rates, immune response, and infections in total joint arthroplasty: a review of the current literature. Int Orthop. 2019, 43:1549-57. 10.1007\/s00264-018-4237-8","journal-title":"Int Orthop"},{"key":"ref27","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.CC.N.00157","article-title":"Early fracture of a vitamin-E-infused, highly cross-linked polyethylene liner after total hip arthroplasty","volume":"5","author":"Bates MD","year":"2015","unstructured":"Bates MD, Mauerhan DR. Early fracture of a vitamin-E-infused, highly cross-linked polyethylene liner after total hip arthroplasty. JBJS Case Connect. 2015, 5:e65. 10.2106\/JBJS.CC.N.00157","journal-title":"JBJS Case Connect"},{"key":"ref28","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmbbm.2011.03.012","article-title":"Tradeoffs amongst fatigue, wear, and oxidation resistance of cross-linked ultra-high molecular weight polyethylene","volume":"4","author":"Atwood SA","year":"2011","unstructured":"Atwood SA, Van Citters DW, Patten EW, Furmanski J, Ries MD, Pruitt LA. Tradeoffs amongst fatigue, wear, and oxidation resistance of cross-linked ultra-high molecular weight polyethylene. J Mech Behav Biomed Mater. 2011, 4:1033-45. 10.1016\/j.jmbbm.2011.03.012","journal-title":"J Mech Behav Biomed Mater"},{"key":"ref29","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmbbm.2015.08.026","article-title":"Effect of processing, sterilization and crosslinking on UHMWPE fatigue fracture and fatigue wear mechanisms in joint arthroplasty","volume":"53","author":"Ansari F","year":"2016","unstructured":"Ansari F, Ries MD, Pruitt L. Effect of processing, sterilization and crosslinking on UHMWPE fatigue fracture and fatigue wear mechanisms in joint arthroplasty. J Mech Behav Biomed Mater. 2016, 53:329-40. 10.1016\/j.jmbbm.2015.08.026","journal-title":"J Mech Behav Biomed Mater"},{"key":"ref30","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2015.05.009","article-title":"Highly cross-linked versus conventional polyethylene in posterior-stabilized total knee arthroplasty at a mean 5-year follow-up","volume":"30","author":"Meneghini RM","year":"2015","unstructured":"Meneghini RM, Lovro LR, Smits SA, Ireland PH. Highly cross-linked versus conventional polyethylene in posterior-stabilized total knee arthroplasty at a mean 5-year follow-up. J Arthroplasty. 2015, 30:1736-9. 10.1016\/j.arth.2015.05.009","journal-title":"J Arthroplasty"},{"key":"ref31","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.b.31458","article-title":"In vivo comparison of wear particles between highly crosslinked polyethylene and conventional polyethylene in the same design of total knee arthroplasties","volume":"91","author":"Iwakiri K","year":"2009","unstructured":"Iwakiri K, Minoda Y, Kobayashi A, et al.. In vivo comparison of wear particles between highly crosslinked polyethylene and conventional polyethylene in the same design of total knee arthroplasties. J Biomed Mater Res B Appl Biomater. 2009, 91:799-804. 10.1002\/jbm.b.31458","journal-title":"J Biomed Mater Res B Appl Biomater"},{"key":"ref32","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2015.10.034","article-title":"Multicenter study of highly cross-linked vs conventional polyethylene in total knee arthroplasty","volume":"31","author":"Meneghini RM","year":"2016","unstructured":"Meneghini RM, Ireland PH, Bhowmik-Stoker M. Multicenter study of highly cross-linked vs conventional polyethylene in total knee arthroplasty. J Arthroplasty. 2016, 31:809-14. 10.1016\/j.arth.2015.10.034","journal-title":"J Arthroplasty"},{"key":"ref33","doi-asserted-by":"publisher","DOI":"10.1007\/s00776-008-1258-y","article-title":"Arthroscopy for evaluation of polyethylene wear after total knee arthroplasty","volume":"13","author":"Kondo M","year":"2008","unstructured":"Kondo M, Fujii T, Kitagawa H, Tsumura H, Kadoya Y. Arthroscopy for evaluation of polyethylene wear after total knee arthroplasty. J Orthop Sci. 2008, 13:433-7. 10.1007\/s00776-008-1258-y","journal-title":"J Orthop Sci"},{"key":"ref34","doi-asserted-by":"publisher","DOI":"10.1177\/2309499018808356","article-title":"Polyethylene in total knee arthroplasty: where are we now?","volume":"26","author":"Wilhelm SK","year":"2018","unstructured":"Wilhelm SK, Henrichsen JL, Siljander M, Moore D, Karadsheh M. Polyethylene in total knee arthroplasty: where are we now?. J Orthop Surg. 2018, 26:10.1177\/2309499018808356","journal-title":"J Orthop Surg"},{"key":"ref35","doi-asserted-by":"publisher","DOI":"10.3109\/17453674.2015.1065046","article-title":"Lower prosthesis-specific 10-year revision rate with crosslinked than with non-crosslinked polyethylene in primary total knee arthroplasty","volume":"86","author":"De Steiger RN","year":"2015","unstructured":"De Steiger RN, Muratoglu O, Lorimer M, Cuthbert AR, Graves SE. Lower prosthesis-specific 10-year revision rate with crosslinked than with non-crosslinked polyethylene in primary total knee arthroplasty. Acta Orthop. 2015, 86:721-7. 10.3109\/17453674.2015.1065046","journal-title":"Acta Orthop"},{"key":"ref36","doi-asserted-by":"publisher","DOI":"10.5312\/wjo.v6.i2.172","article-title":"Biological response to prosthetic debris","volume":"6","author":"Bitar D","year":"2015","unstructured":"Bitar D, Parvizi J. Biological response to prosthetic debris. World J Orthop. 2015, 6:172-89. 10.5312\/wjo.v6.i2.172","journal-title":"World J Orthop"},{"key":"ref37","doi-asserted-by":"publisher","DOI":"10.1243\/0954411001535219","article-title":"Biological reactions to wear debris in total joint replacement","volume":"214","author":"Ingham E","year":"2000","unstructured":"Ingham E, Fisher J. Biological reactions to wear debris in total joint replacement. Proc Inst Mech Eng H. 2000, 214:21-37. 10.1243\/0954411001535219","journal-title":"Proc Inst Mech Eng H"},{"key":"ref38","doi-asserted-by":"publisher","DOI":"10.1016\/j.actbio.2015.05.016","article-title":"The biological response to nanometre-sized polymer particles","volume":"23","author":"Liu A","year":"2015","unstructured":"Liu A, Richards L, Bladen CL, Ingham E, Fisher J, Tipper JL. The biological response to nanometre-sized polymer particles. Acta Biomater. 2015, 23:38-51. 10.1016\/j.actbio.2015.05.016","journal-title":"Acta Biomater"},{"key":"ref39","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.b.32887","article-title":"Clinical trade-offs in cross-linked ultrahigh-molecular-weight polyethylene used in total joint arthroplasty","volume":"101","author":"Pruitt LA","year":"2013","unstructured":"Pruitt LA, Ansari F, Kury M, et al.. Clinical trade-offs in cross-linked ultrahigh-molecular-weight polyethylene used in total joint arthroplasty. J Biomed Mater Res B Appl Biomater. 2013, 101:476-84. 10.1002\/jbm.b.32887","journal-title":"J Biomed Mater Res B Appl Biomater"},{"key":"ref40","doi-asserted-by":"publisher","DOI":"10.3109\/17453674.2013.784660","article-title":"Alternative bearings in total knee arthroplasty: risk of early revision compared to traditional bearings: an analysis of 62,177 primary cases","volume":"84","author":"Inacio MCS","year":"2013","unstructured":"Inacio MCS, Cafri G, Paxton EW, Kurtz SM, Namba RS. Alternative bearings in total knee arthroplasty: risk of early revision compared to traditional bearings: an analysis of 62,177 primary cases. Acta Orthop. 2013, 84:145-52. 10.3109\/17453674.2013.784660","journal-title":"Acta Orthop"},{"key":"ref41","doi-asserted-by":"publisher","DOI":"10.1007\/s11999-014-4046-3","article-title":"Is there a difference in total knee arthroplasty risk of revision in highly crosslinked versus conventional polyethylene?","volume":"473","author":"Paxton EW","year":"2015","unstructured":"Paxton EW, Inacio MCS, Kurtz S, Love R, Cafri G, Namba RS. Is there a difference in total knee arthroplasty risk of revision in highly crosslinked versus conventional polyethylene?. Clin Orthop Relat Res. 2015, 473:999-1008. 10.1007\/s11999-014-4046-3","journal-title":"Clin Orthop Relat Res"},{"key":"ref42","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.19.00031","article-title":"Conventional versus highly cross-linked polyethylene in primary total knee replacement: a comparison of revision rates using data from the national joint registry for England, Wales, and Northern Ireland","volume":"102","author":"Partridge TCJ","year":"2020","unstructured":"Partridge TCJ, Baker PN, Jameson SS, Mason J, Reed MR, Deehan DJ. Conventional versus highly cross-linked polyethylene in primary total knee replacement: a comparison of revision rates using data from the national joint registry for England, Wales, and Northern Ireland. J Bone Joint Surg Am. 2020, 102:119-27. 10.2106\/JBJS.19.00031","journal-title":"J Bone Joint Surg Am"},{"key":"ref43","doi-asserted-by":"publisher","DOI":"10.1007\/s11999-010-1436-z","article-title":"Do \u201cpremium\u201d joint implants add value?: analysis of high cost joint implants in a community registry","volume":"469","author":"Gioe TJ","year":"2011","unstructured":"Gioe TJ, Sharma A, Tatman P, Mehle S. Do \u201cpremium\u201d joint implants add value?: analysis of high cost joint implants in a community registry. Clin Orthop Relat Res. 2011, 469:48-54. 10.1007\/s11999-010-1436-z","journal-title":"Clin Orthop Relat Res"},{"key":"ref44","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0062709","article-title":"Placing a price on medical device innovation: the example of total knee arthroplasty","volume":"8","author":"Suter LG","year":"2013","unstructured":"Suter LG, Paltiel AD, Rome BN, et al.. Placing a price on medical device innovation: the example of total knee arthroplasty. PLoS One. 2013, 8:e62709. 10.1371\/journal.pone.0062709","journal-title":"PLoS One"},{"key":"ref45","doi-asserted-by":"publisher","DOI":"10.1002\/adbi.201800212","article-title":"Carbon nanotubes and graphene as nanoreinforcements in metallic biomaterials: a review","volume":"3","author":"Munir KS","year":"2019","unstructured":"Munir KS, Wen C, Li Y. Carbon nanotubes and graphene as nanoreinforcements in metallic biomaterials: a review. Adv Biosyst. 2019, 3:1800212. 10.1002\/adbi.201800212","journal-title":"Adv Biosyst"},{"key":"ref46","doi-asserted-by":"publisher","DOI":"10.1016\/j.msec.2018.07.029","article-title":"Strain and damage-sensing performance of biocompatible smart CNT\/UHMWPE nanocomposites","volume":"92","author":"Reddy SK","year":"2018","unstructured":"Reddy SK, Kumar S, Varadarajan KM, Marpu PR, Gupta TK, Choosri M. Strain and damage-sensing performance of biocompatible smart CNT\/UHMWPE nanocomposites. Mater Sci Eng C. 2018, 92:957-68. 10.1016\/j.msec.2018.07.029","journal-title":"Mater Sci Eng C"},{"key":"ref47","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmbbm.2014.06.013","article-title":"Evaluation of carbon nanotubes and graphene as reinforcements for UHMWPE-based composites in arthroplastic applications: a review","volume":"39","author":"Pu\u00e9rtolas JA","year":"2014","unstructured":"Pu\u00e9rtolas JA, Kurtz SM. Evaluation of carbon nanotubes and graphene as reinforcements for UHMWPE-based composites in arthroplastic applications: a review. J Mech Behav Biomed Mater. 2014, 39:129-45. 10.1016\/j.jmbbm.2014.06.013","journal-title":"J Mech Behav Biomed Mater"},{"key":"ref48","doi-asserted-by":"publisher","DOI":"10.3390\/lubricants3020413","article-title":"Wear performance of UHMWPE and reinforced UHMWPE composites in arthroplasty applications: a review","volume":"3","author":"Baena JC","year":"2015","unstructured":"Baena JC, Wu J, Peng Z. Wear performance of UHMWPE and reinforced UHMWPE composites in arthroplasty applications: a review. Lubricants. 2015, 3:413-36. 10.3390\/lubricants3020413","journal-title":"Lubricants"},{"key":"ref49","doi-asserted-by":"publisher","DOI":"10.1016\/S0883-5403(96)80093-3","article-title":"Early failure of hylamer acetabular inserts due to eccentric wear","volume":"11","author":"Chmell MJ","year":"1996","unstructured":"Chmell MJ, Poss R, Thomas WH, Sledge CB. Early failure of hylamer acetabular inserts due to eccentric wear. J Arthroplasty. 1996, 11:351-3. 10.1016\/S0883-5403(96)80093-3","journal-title":"J Arthroplasty"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/49434-plastics-in-total-knee-replacement-processing-to-performance","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,2,9]],"date-time":"2024-02-09T19:29:33Z","timestamp":1707506973000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/49434-plastics-in-total-knee-replacement-processing-to-performance"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,1,28]]},"references-count":49,"URL":"https:\/\/doi.org\/10.7759\/cureus.12969","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2021,1,28]]}}}