{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,19]],"date-time":"2026-02-19T03:31:03Z","timestamp":1771471863451,"version":"3.50.1"},"reference-count":15,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2021,8,5]]},"DOI":"10.7759\/cureus.16907","type":"journal-article","created":{"date-parts":[[2021,8,5]],"date-time":"2021-08-05T14:34:51Z","timestamp":1628174091000},"source":"Crossref","is-referenced-by-count":3,"title":["Complications and Risk Factors of Patients Undergoing Computed Tomography-Guided Core Needle Lung Biopsy: A Single-Center Experience"],"prefix":"10.7759","author":[{"given":"Waseem  M","family":"Hajjar","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ibrahim M","family":"Fetyani","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rayan M","family":"Alqarni","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fahad  A","family":"Alajlan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fouad F","family":"Bahgat","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sultan  R","family":"Alharbi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.5114\/pjr.2018.79205","article-title":"Risk factors of pneumothorax and chest tube placement after computed tomography-guided core needle biopsy of lung lesions: a single-centre experience with 822 biopsies","volume":"83","author":"Ozturk K","year":"2018","unstructured":"Ozturk K, Soylu E, Gokalp G, Topal U. Risk factors of pneumothorax and chest tube placement after computed tomography-guided core needle biopsy of lung lesions: a single-centre experience with 822 biopsies. Pol J Radiol. 2018, 83:e407-14. 10.5114\/pjr.2018.79205","journal-title":"Pol J Radiol"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1159\/000489934","article-title":"Diagnostic yield and complications of transthoracic computed tomography-guided biopsies","volume":"96","author":"Padr\u00e3o E","year":"2018","unstructured":"Padr\u00e3o E, Rodrigues M, Guimar\u00e3es S, et al.. Diagnostic yield and complications of transthoracic computed tomography-guided biopsies. Respiration. 2018, 96:455-63. 10.1159\/000489934","journal-title":"Respiration"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1007\/s00508-018-1317-0","article-title":"Complications of CT-guided transthoracic lung biopsy: a short report on current literature and a\u00a0case of systemic air embolism","volume":"130","author":"Lang D","year":"2018","unstructured":"Lang D, Reinelt V, Horner A, Akbari K, Fellner F, Lichtenberger P, Lamprecht B. Complications of CT-guided transthoracic lung biopsy: a short report on current literature and a\u00a0case of systemic air embolism. Wien Klin Wochenschr. 2018, 130:288-92. 10.1007\/s00508-018-1317-0","journal-title":"Wien Klin Wochenschr"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-016-4357-8","article-title":"Complication rates of CT-guided transthoracic lung biopsy: meta-analysis","volume":"27","author":"Heerink WJ","year":"2017","unstructured":"Heerink WJ, de Bock GH, de Jonge GJ, Groen HJ, Vliegenthart R, Oudkerk M. Complication rates of CT-guided transthoracic lung biopsy: meta-analysis. Eur Radiol. 2017, 27:138-48. 10.1007\/s00330-016-4357-8","journal-title":"Eur Radiol"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.5114\/pjr.2018.75825","article-title":"Percutaneous lung needle biopsies - utility and complications in various chest lesions: a single-institution experience","volume":"83","author":"Jelitto-Gorska M","year":"2018","unstructured":"Jelitto-Gorska M, Studniarek M, Durawa A, Marjanski T, Szurowska E. Percutaneous lung needle biopsies - utility and complications in various chest lesions: a single-institution experience. Pol J Radiol. 2018, 83:e103-8. 10.5114\/pjr.2018.75825","journal-title":"Pol J Radiol"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.10.4659","article-title":"Complications of CT-guided percutaneous needle biopsy of the chest: prevention and management","volume":"196","author":"Wu CC","year":"2011","unstructured":"Wu CC, Maher MM, Shepard JA. Complications of CT-guided percutaneous needle biopsy of the chest: prevention and management. AJR Am J Roentgenol. 2011, 196:W678-82. 10.2214\/AJR.10.4659","journal-title":"AJR Am J Roentgenol"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.3978\/j.issn.2072-1439.2013.12.08","article-title":"Pneumothorax after transthoracic needle biopsy of lung lesions under CT guidance","volume":"6 Suppl 1","author":"Boskovic T","year":"2014","unstructured":"Boskovic T, Stanic J, Pena-Karan S, et al.. Pneumothorax after transthoracic needle biopsy of lung lesions under CT guidance. J Thorac Dis. 2014, 6 Suppl 1:S99-107. 10.3978\/j.issn.2072-1439.2013.12.08","journal-title":"J Thorac Dis"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.09.3224","article-title":"Incidence of and risk factors for pneumothorax and chest tube placement after CT fluoroscopy-guided percutaneous lung biopsy: retrospective analysis of the procedures conducted over a 9-year period","volume":"194","author":"Hiraki T","year":"2010","unstructured":"Hiraki T, Mimura H, Gobara H, Shibamoto K, Inoue D, Matsui Y, Kanazawa S. Incidence of and risk factors for pneumothorax and chest tube placement after CT fluoroscopy-guided percutaneous lung biopsy: retrospective analysis of the procedures conducted over a 9-year period. AJR Am J Roentgenol. 2010, 194:809-14. 10.2214\/AJR.09.3224","journal-title":"AJR Am J Roentgenol"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.5114\/pjr.2018.79202","article-title":"Influencing factors of pneumothorax and parenchymal haemorrhage after CT-guided transthoracic needle biopsy: single-institution experience","volume":"83","author":"Wattanasatesiri T","year":"2018","unstructured":"Wattanasatesiri T, Puntu W, Vithitsuvanakul N. Influencing factors of pneumothorax and parenchymal haemorrhage after CT-guided transthoracic needle biopsy: single-institution experience. Pol J Radiol. 2018, 83:e379-88. 10.5114\/pjr.2018.79202","journal-title":"Pol J Radiol"},{"key":"ref10","article-title":"Diagnostic yield and complications of transthoracic computed tomography-guided biopsies","volume":"63","author":"Vagn-Hansen C","year":"2016","unstructured":"Vagn-Hansen C, Pedersen MR, Rafaelsen SR. Diagnostic yield and complications of transthoracic computed tomography-guided biopsies. Dan Med J. 2016, 63:A5239.","journal-title":"Dan Med J"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.2147\/OTT.S45013","article-title":"Diagnostic efficacy of computed tomography-guided transthoracic needle aspiration and biopsy in patients with pulmonary disease","volume":"6","author":"Tuna T","year":"2013","unstructured":"Tuna T, Ozkaya S, Dirican A, Findik S, Atici AG, Erkan L. Diagnostic efficacy of computed tomography-guided transthoracic needle aspiration and biopsy in patients with pulmonary disease. Onco Targets Ther. 2013, 6:1553-7. 10.2147\/OTT.S45013","journal-title":"Onco Targets Ther"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1007\/s00270-015-1167-3","article-title":"Pneumothorax complicating coaxial and non-coaxial CT-guided lung biopsy: comparative analysis of determining risk factors and management of pneumothorax in a retrospective review of 650 patients","volume":"39","author":"Nour-Eldin NE","year":"2016","unstructured":"Nour-Eldin NE, Alsubhi M, Emam A, et al.. Pneumothorax complicating coaxial and non-coaxial CT-guided lung biopsy: comparative analysis of determining risk factors and management of pneumothorax in a retrospective review of 650 patients. Cardiovasc Intervent Radiol. 2016, 39:261-70. 10.1007\/s00270-015-1167-3","journal-title":"Cardiovasc Intervent Radiol"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.3892\/ol.2013.1680","article-title":"Computed tomography-guided core needle biopsy of lung lesions: diagnostic yield and correlation between factors and complications","volume":"7","author":"Wang Y","year":"2014","unstructured":"Wang Y, Li W, He X, Li G, Xu L. Computed tomography-guided core needle biopsy of lung lesions: diagnostic yield and correlation between factors and complications. Oncol Lett. 2014, 7:288-94. 10.3892\/ol.2013.1680","journal-title":"Oncol Lett"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1016\/j.rppneu.2014.01.009","article-title":"CT-guided transthoracic lung biopsy: predictive factors of pneumothorax","volume":"20","author":"Cruz JF","year":"2014","unstructured":"Cruz JF, Rolo R, Igl\u00e9sias L, Cunha J. CT-guided transthoracic lung biopsy: predictive factors of pneumothorax. Rev Port Pneumol. 2014, 20:174-6. 10.1016\/j.rppneu.2014.01.009","journal-title":"Rev Port Pneumol"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.3348\/kjr.2015.16.1.206","article-title":"CT-guided core needle biopsy of pleural lesions: evaluating diagnostic yield and associated complications","volume":"16","author":"Niu XK","year":"2015","unstructured":"Niu XK, Bhetuwal A, Yang HF. CT-guided core needle biopsy of pleural lesions: evaluating diagnostic yield and associated complications. Korean J Radiol. 2015, 16:206-12. 10.3348\/kjr.2015.16.1.206","journal-title":"Korean J Radiol"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/62140-complications-and-risk-factors-of-patients-undergoing-computed-tomography-guided-core-needle-lung-biopsy-a-single-center-experience","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,2,9]],"date-time":"2024-02-09T19:33:12Z","timestamp":1707507192000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/62140-complications-and-risk-factors-of-patients-undergoing-computed-tomography-guided-core-needle-lung-biopsy-a-single-center-experience"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,8,5]]},"references-count":15,"URL":"https:\/\/doi.org\/10.7759\/cureus.16907","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2021,8,5]]}}}