{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,2,10]],"date-time":"2024-02-10T00:19:19Z","timestamp":1707524359034},"reference-count":16,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2021,9,27]]},"DOI":"10.7759\/cureus.18321","type":"journal-article","created":{"date-parts":[[2021,9,27]],"date-time":"2021-09-27T12:50:39Z","timestamp":1632747039000},"source":"Crossref","is-referenced-by-count":1,"title":["Early Results of a Variable-Angle Volar Locking Plate for Distal Radius Fractures: A Bi-centre Study"],"prefix":"10.7759","author":[{"given":"Sherif","family":"Elerian","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Talvinder","family":"Singh","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nikolas","family":"A Jagodzinsk","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rory","family":"Norris","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Simon","family":"Tan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dominic","family":"Power","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jonathan","family":"Jones","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zehong","family":"Chen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hassan","family":"Eltagy","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1007\/s00590-008-0338-1","article-title":"A short term functional outcome study comparing closed reduction percutaneous wire fixation with open reduction internal fixation for fractures of the distal radius: a pilot study","volume":"18","author":"Cooper L","year":"2008","unstructured":"Cooper L, Mauffrey C, Hull P, Brewster M, Lewis C, Makrides P. A short term functional outcome study comparing closed reduction percutaneous wire fixation with open reduction internal fixation for fractures of the distal radius: a pilot study. Eur J Orthop Surg Traumato. 2008, 18:551-4. 10.1007\/s00590-008-0338-1","journal-title":"Eur J Orthop Surg Traumato"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.90B10.21293","article-title":"A revolution in the management of fractures of the distal radius?","volume":"90","author":"Downing ND","year":"2008","unstructured":"Downing ND, Karantana A. A revolution in the management of fractures of the distal radius?. J Bone Joint Surg Br. 2008, 90:1271-5. 10.1302\/0301-620X.90B10.21293","journal-title":"J Bone Joint Surg Br"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1007\/s001980170076","article-title":"Incidence of distal forearm fracture in British men and women","volume":"12","author":"O'Neill TW","year":"2001","unstructured":"O'Neill TW, Cooper C, Finn JD, et al.. Incidence of distal forearm fracture in British men and women. Osteoporos Int. 2001, 12:555-8. 10.1007\/s001980170076","journal-title":"Osteoporos Int"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1007\/s00590-009-0494-y","article-title":"Comparative outcome of distal radial fractures treated by percutaneous k-wire fixation and internal fixation","volume":"20","author":"Flannery O","year":"2010","unstructured":"Flannery O, Naughton M, Walsh A, Awan N. Comparative outcome of distal radial fractures treated by percutaneous k-wire fixation and internal fixation. Eur J Orthop Surg Traumatol. 2010, 20:131-135. 10.1007\/s00590-009-0494-y","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2009.08.024","article-title":"Locked volar plating for unstable distal radial fractures: clinical and radiological outcomes","volume":"41","author":"Knight D","year":"2010","unstructured":"Knight D, Hajducka C, Will E, McQueen M. Locked volar plating for unstable distal radial fractures: clinical and radiological outcomes. Injury. 2010, 41:184-9. 10.1016\/j.injury.2009.08.024","journal-title":"Injury"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1007\/s00264-007-0504-9","article-title":"Comparison of external fixation, locking and non-locking palmar plating for unstable distal radius fractures in the elderly","volume":"33","author":"Schmelzer-Schmied N","year":"2009","unstructured":"Schmelzer-Schmied N, Wieloch P, Martini AK, Daecke W. Comparison of external fixation, locking and non-locking palmar plating for unstable distal radius fractures in the elderly. Int Orthop. 2009, 33:773-8. 10.1007\/s00264-007-0504-9","journal-title":"Int Orthop"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.3109\/17453670902947440","article-title":"Different osteosyntheses for Colles' fracture. A mechanical study in 42 cadaver bones","volume":"80","author":"Krukhaug Y","year":"2009","unstructured":"Krukhaug Y, Gjerdet NR, Lundberg OJ, Lilleng PK, Hove LM. Different osteosyntheses for Colles' fracture. A mechanical study in 42 cadaver bones. Acta Orthop. 2009, 80:239-44. 10.3109\/17453670902947440","journal-title":"Acta Orthop"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1177%2F1753193408090129","article-title":"Palmer fixation of dorsally displaced distal radius fractures using locking plates with Smartlock locking screws","volume":"34","author":"Wong TC","year":"2009","unstructured":"Wong TC, Yeung CC, Chiu Y, Yeung SH, Ip FK. Palmer fixation of dorsally displaced distal radius fractures using locking plates with Smartlock locking screws. J Hand Surg. 2009, 34:173-8. 10.1177%2F1753193408090129","journal-title":"J Hand Surg"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1097\/BOT.0b013e31819b24e9","article-title":"A comparative study of clinical and radiologic outcomes of unstable Colles type distal radius fractures in patients older than 70 years: nonoperative treatment versus volar locking plating","volume":"23","author":"Arora R","year":"2009","unstructured":"Arora R, Gabl M, Gschwentner M, Deml C, Krappinger D, Lutz M. A comparative study of clinical and radiologic outcomes of unstable Colles type distal radius fractures in patients older than 70 years: nonoperative treatment versus volar locking plating. J Orthop Trauma. 2009, 23:237-42. 10.1097\/BOT.0b013e31819b24e9","journal-title":"J Orthop Trauma"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.G.01498","article-title":"Operative management of distal radial fractures with 2.4-millimeter locking plates. A multicenter prospective case series","volume":"91","author":"Jupiter JB","year":"2009","unstructured":"Jupiter JB, Marent-Huber M. Operative management of distal radial fractures with 2.4-millimeter locking plates. A multicenter prospective case series. J Bone Joint Surg Am. 2009, 91:55-65. 10.2106\/JBJS.G.01498","journal-title":"J Bone Joint Surg Am"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhsa.2005.10.010","article-title":"Functional outcome and complications after volar plating for dorsally displaced, unstable fractures of the distal radius","volume":"31","author":"Rozental TD","year":"2006","unstructured":"Rozental TD, Blazar PE. Functional outcome and complications after volar plating for dorsally displaced, unstable fractures of the distal radius. J Hand Surg Am. 2006, 31:359-65. 10.1016\/j.jhsa.2005.10.010","journal-title":"J Hand Surg Am"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1016\/j.hcl.2009.08.002","article-title":"Plating for distal radius fractures","volume":"26","author":"Martineau PA","year":"2010","unstructured":"Martineau PA, Berry GK, Harvey EJ. Plating for distal radius fractures. Hand Clin. 2010, 26:61-9. 10.1016\/j.hcl.2009.08.002","journal-title":"Hand Clin"},{"key":"ref13","doi-asserted-by":"crossref","DOI":"10.2106\/00004623-195133040-00009","article-title":"Evaluation of healed Colle's fractures","volume":"33","author":"Gartland JJ","year":"1951","unstructured":"Gartland JJ, Werley CW. Evaluation of healed Colle's fractures. J Bone Joint Surg. 1951, 33:895-907.","journal-title":"J Bone Joint Surg"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1016\/S0363-5023(96)80151-1","article-title":"X-ray film measurements for healed distal radius fractures","volume":"21","author":"Kreder HJ","year":"1996","unstructured":"Kreder HJ, Hanel DP, McKee M, Jupiter J, McGillivary G, Swiontkowski. X-ray film measurements for healed distal radius fractures. J Hand Surg. 1996, 21:31-39. 10.1016\/S0363-5023(96)80151-1","journal-title":"J Hand Surg"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhsa.2007.04.016","article-title":"Volar versus dorsal fixed-angle fixation of dorsally unstable extra-articular distal radius fractures: a biomechanic study","volume":"32","author":"McCall TA","year":"2007","unstructured":"McCall TA, Conrad B, Badman B, Wright T. Volar versus dorsal fixed-angle fixation of dorsally unstable extra-articular distal radius fractures: a biomechanic study. J Hand Surg Am. 2007, 32:806-12. 10.1016\/j.jhsa.2007.04.016","journal-title":"J Hand Surg Am"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2009.09.025","article-title":"A novel non-bridging external fixator construct versus volar angular stable plating for the fixation of intra-articular fractures of the distal radius\u2014a biomechanical study","volume":"41","author":"Windolf M","year":"2010","unstructured":"Windolf M, Schwieger K, Ockert B, Jupiter JB, Gradl G. A novel non-bridging external fixator construct versus volar angular stable plating for the fixation of intra-articular fractures of the distal radius\u2014a biomechanical study. Injury. 2010, 41:204-9. 10.1016\/j.injury.2009.09.025","journal-title":"Injury"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/69121-early-results-of-a-variable-angle-volar-locking-plate-for-distal-radius-fractures-a-bi-centre-study","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,2,9]],"date-time":"2024-02-09T19:34:25Z","timestamp":1707507265000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/69121-early-results-of-a-variable-angle-volar-locking-plate-for-distal-radius-fractures-a-bi-centre-study"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,9,27]]},"references-count":16,"URL":"https:\/\/doi.org\/10.7759\/cureus.18321","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2021,9,27]]}}}