{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,30]],"date-time":"2025-12-30T03:40:25Z","timestamp":1767066025610},"reference-count":18,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2022,1,14]]},"DOI":"10.7759\/cureus.21254","type":"journal-article","created":{"date-parts":[[2022,1,15]],"date-time":"2022-01-15T04:01:10Z","timestamp":1642219270000},"source":"Crossref","is-referenced-by-count":2,"title":["Failure of Primary Distal Biceps Repair After Cortical Button Fixation With Whipstitch Technique: A Root Cause Analysis"],"prefix":"10.7759","author":[{"given":"Naga","family":"Cheppalli","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sreenivasulu","family":"Metikala","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eric","family":"Leung","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dustin L","family":"Richter","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1177\/0363546520986999","article-title":"Optimizing fixation for distal biceps tendon repairs: a systematic review and meta-regression of cadaveric biomechanical testing","volume":"49","author":"Taylor AL","year":"2021","unstructured":"Taylor AL, Bansal A, Shi BY, Best MJ, Huish EG Jr, Srikumaran U. Optimizing fixation for distal biceps tendon repairs: a systematic review and meta-regression of cadaveric biomechanical testing. Am J Sports Med. 2021, 49:3125-31. 10.1177\/0363546520986999","journal-title":"Am J Sports Med"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1177\/0363546517720200","article-title":"Surgical treatment of distal biceps tendon ruptures: an analysis of complications in 784 surgical repairs","volume":"45","author":"Dunphy TR","year":"2017","unstructured":"Dunphy TR, Hudson J, Batech M, Acevedo DC, Mirzayan R. Surgical treatment of distal biceps tendon ruptures: an analysis of complications in 784 surgical repairs. Am J Sports Med. 2017, 45:3020-9. 10.1177\/0363546517720200","journal-title":"Am J Sports Med"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2014.02.006","article-title":"Re-rupture rate of primarily repaired distal biceps tendon injuries","volume":"23","author":"Hinchey JW","year":"2014","unstructured":"Hinchey JW, Aronowitz JG, Sanchez-Sotelo J, Morrey BF. Re-rupture rate of primarily repaired distal biceps tendon injuries. J Shoulder Elbow Surg. 2014, 23:850-4. 10.1016\/j.jse.2014.02.006","journal-title":"J Shoulder Elbow Surg"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1097\/BTO.0000000000000555","article-title":"Retrospective study of the distal biceps tendon repair using \"all-suture\" soft anchors","author":"Metikala S","year":"2021","unstructured":"Metikala S, Saleh Z, Bader DA, Sebastianelli WJ, Sherbondy PS. Retrospective study of the distal biceps tendon repair using \"all-suture\" soft anchors. Tech Orthop. 2021, 10.1097\/BTO.0000000000000555","journal-title":"Tech Orthop"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1097\/BTE.0b013e3181862af5","article-title":"Anatomical repair of the distal biceps tendon using the tension-slide technique","volume":"9","author":"Sethi P","year":"2008","unstructured":"Sethi P, Cunningham J, Miller S, Sutton K, Mazzocca A. Anatomical repair of the distal biceps tendon using the tension-slide technique. Tech Shoulder Elb Surg. 2008, 9:182-7. 10.1097\/BTE.0b013e3181862af5","journal-title":"Tech Shoulder Elb Surg"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-198668050-00020","article-title":"A new stitch for ligament-tendon fixation. Brief note","volume":"68","author":"Krackow KA","year":"1986","unstructured":"Krackow KA, Thomas SC, Jones LC. A new stitch for ligament-tendon fixation. Brief note. J Bone Joint Surg Am. 1986, 68:764-6. 10.2106\/00004623-198668050-00020","journal-title":"J Bone Joint Surg Am"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1093\/bmb\/ldn023","article-title":"Rating systems for evaluation of the elbow","volume":"87","author":"Longo UG","year":"2008","unstructured":"Longo UG, Franceschi F, Loppini M, Maffulli N, Denaro V. Rating systems for evaluation of the elbow. Br Med Bull. 2008, 87:131-61. 10.1093\/bmb\/ldn023","journal-title":"Br Med Bull"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1155\/2016\/3498403","article-title":"Clinical outcomes and complications of cortical button distal biceps repair: a systematic review of the literature","volume":"2016","author":"Panagopoulos A","year":"2016","unstructured":"Panagopoulos A, Tatani I, Tsoumpos P, Ntourantonis D, Pantazis K, Triantafyllopoulos IK. Clinical outcomes and complications of cortical button distal biceps repair: a systematic review of the literature. J Sports Med (Hindawi Publ Corp). 2016, 2016:3498403. 10.1155\/2016\/3498403","journal-title":"J Sports Med (Hindawi Publ Corp)"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhsa.2019.05.006","article-title":"Diagnosis, etiology and outcomes of revision distal biceps tendon reattachment","volume":"45","author":"Prokuski V","year":"2020","unstructured":"Prokuski V, Leung NL, Leslie BM. Diagnosis, etiology and outcomes of revision distal biceps tendon reattachment. J Hand Surg Am. 2020, 45:156.e1-9. 10.1016\/j.jhsa.2019.05.006","journal-title":"J Hand Surg Am"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1177\/2325967120981752","article-title":"Clinical outcomes after revision distal biceps tendon surgery","volume":"9","author":"Grewal G","year":"2021","unstructured":"Grewal G, Bernardoni ED, Cohen MS, Fernandez JJ, Verma NN, Romeo AA, Frank RM. Clinical outcomes after revision distal biceps tendon surgery. Orthop J Sports Med. 2021, 9:2325967120981752. 10.1177\/2325967120981752","journal-title":"Orthop J Sports Med"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1177\/0363546508323745","article-title":"Security of knots tied with ethibond, fiberwire, orthocord, or ultrabraid","volume":"36","author":"Ilahi OA","year":"2008","unstructured":"Ilahi OA, Younas SA, Ho DM, Noble PC. Security of knots tied with ethibond, fiberwire, orthocord, or ultrabraid. Am J Sports Med. 2008, 36:2407-14. 10.1177\/0363546508323745","journal-title":"Am J Sports Med"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1177\/0363546507300690","article-title":"Failure strengths in distal biceps tendon repair","volume":"35","author":"Kettler M","year":"2007","unstructured":"Kettler M, Lunger J, Kuhn V, Mutschler W, Tingart MJ. Failure strengths in distal biceps tendon repair. Am J Sports Med. 2007, 35:1544-8. 10.1177\/0363546507300690","journal-title":"Am J Sports Med"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2018.10.140","article-title":"A biomechanical comparison of six suture configurations for soft tissue-based graft traction and fixation","volume":"35","author":"Barber FA","year":"2019","unstructured":"Barber FA, Howard MS, Piccirillo J, Spenciner DB. A biomechanical comparison of six suture configurations for soft tissue-based graft traction and fixation. Arthroscopy. 2019, 35:1163-9. 10.1016\/j.arthro.2018.10.140","journal-title":"Arthroscopy"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.3928\/01477447-20100722-08","article-title":"Evaluation of high-strength orthopedic sutures: a head-to-head comparison","volume":"33","author":"Miller T","year":"2010","unstructured":"Miller T, Feinblatt J, Craw J, Litsky A, Flanigan D. Evaluation of high-strength orthopedic sutures: a head-to-head comparison. Orthopedics. 2010, 33:674. 10.3928\/01477447-20100722-08","journal-title":"Orthopedics"},{"key":"ref15","article-title":"SpeedWhipTM Technique with FiberLoop\u00ae and TigerLoop\u00ae","year":"2011","unstructured":"SpeedWhipTM Technique with FiberLoop\u00ae and TigerLoop\u00ae. Arthrex, Inc., Naples, Florida; 2011."},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2007.11.020","article-title":"Krackow locking stitch versus nonlocking premanufactured loop stitch for soft-tissue fixation: a biomechanical study","volume":"24","author":"Deramo DM","year":"2008","unstructured":"Deramo DM, White KL, Parks BG, Hinton RY. Krackow locking stitch versus nonlocking premanufactured loop stitch for soft-tissue fixation: a biomechanical study. Arthroscopy. 2008, 24:599-603. 10.1016\/j.arthro.2007.11.020","journal-title":"Arthroscopy"},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2011.10.014","article-title":"The modified finger-trap suture technique: a biomechanical comparison of a novel suture technique for graft fixation","volume":"28","author":"Su WR","year":"2012","unstructured":"Su WR, Chu CH, Lin CL, Lin CJ, Jou IM, Chang CW. The modified finger-trap suture technique: a biomechanical comparison of a novel suture technique for graft fixation. Arthroscopy. 2012, 28:702-10. 10.1016\/j.arthro.2011.10.014","journal-title":"Arthroscopy"},{"key":"ref18","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2015.08.013","article-title":"High-tensile strength tape versus high-tensile strength suture: a biomechanical study","volume":"32","author":"Gnandt RJ","year":"2016","unstructured":"Gnandt RJ, Smith JL, Nguyen-Ta K, McDonald L, LeClere LE. High-tensile strength tape versus high-tensile strength suture: a biomechanical study. Arthroscopy. 2016, 32:356-63. 10.1016\/j.arthro.2015.08.013","journal-title":"Arthroscopy"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/81445-failure-of-primary-distal-biceps-repair-after-cortical-button-fixation-with-whipstitch-technique-a-root-cause-analysis","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,2,9]],"date-time":"2024-02-09T19:41:41Z","timestamp":1707507701000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/81445-failure-of-primary-distal-biceps-repair-after-cortical-button-fixation-with-whipstitch-technique-a-root-cause-analysis"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,1,14]]},"references-count":18,"URL":"https:\/\/doi.org\/10.7759\/cureus.21254","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2022,1,14]]}}}