{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,2]],"date-time":"2026-08-02T16:38:28Z","timestamp":1785688708536,"version":"3.56.0"},"reference-count":22,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2022,3,15]]},"DOI":"10.7759\/cureus.23176","type":"journal-article","created":{"date-parts":[[2022,3,15]],"date-time":"2022-03-15T13:32:12Z","timestamp":1647351132000},"source":"Crossref","is-referenced-by-count":2,"title":["Clinical Performance Comparison of LMA Protector\u2122 Cuff Pilot\u2122 and LMA Supreme\u2122 When Used in Anesthetized, Non-paralyzed Patients"],"prefix":"10.7759","author":[{"given":"Weng Ken","family":"Chan","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chian Yong","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1111\/anae.12003.x","article-title":"Archie brain: celebrating 30 years of development in laryngeal mask airways","volume":"67","author":"van Zundert TC","year":"2012","unstructured":"van Zundert TC, Brimacombe JR, Ferson DZ, Bacon DR, Wilkinson DJ. Archie brain: celebrating 30 years of development in laryngeal mask airways. Anaesthesia. 2012, 67:1375-85. 10.1111\/anae.12003.x","journal-title":"Anaesthesia"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1007\/BF03011075","article-title":"The advantages of the LMA over the tracheal tube or facemask: a meta-analysis","volume":"42","author":"Brimacombe J","year":"1995","unstructured":"Brimacombe J. The advantages of the LMA over the tracheal tube or facemask: a meta-analysis. Can J Anaesth. 1995, 42:1017-23. 10.1007\/BF03011075","journal-title":"Can J Anaesth"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1093\/bjaceaccp\/mkq058","article-title":"Supraglottic airway devices: recent advances","volume":"11","author":"Cook T","year":"2011","unstructured":"Cook T, Howes B. Supraglottic airway devices: recent advances. Contin Educ Anaesth Crit Care Pain. 2011, 11:56-61. 10.1093\/bjaceaccp\/mkq058","journal-title":"Contin Educ Anaesth Crit Care Pain"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1213\/01.ANE.0000134798.00069.2B","article-title":"A proposed classification and scoring system for supraglottic sealing airways: a brief review","volume":"99","author":"Miller DM","year":"2004","unstructured":"Miller DM. A proposed classification and scoring system for supraglottic sealing airways: a brief review. Anesth Analg. 2004, 99:1553-9. 10.1213\/01.ANE.0000134798.00069.2B","journal-title":"Anesth Analg"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.2147\/MDER.S110186","article-title":"Extraglottic airway devices: technology update","volume":"10","author":"Sharma B","year":"2017","unstructured":"Sharma B, Sahai C, Sood J. Extraglottic airway devices: technology update. Med Devices. 2017, 10:189-205. 10.2147\/MDER.S110186","journal-title":"Med Devices"},{"key":"ref6","unstructured":"LMA supreme\u2122 a second generation SAD with and innovative second seal\u2122. (2014). Accessed. January 7, 2022: https:\/\/www.lmaco.com\/sites\/default\/files\/31817-LMA-SecondSeal-A4-0214-LORES-fnl.pdf."},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/aen174","article-title":"LMA-supreme--a new single-use LMA with gastric access: a report on its clinical efficacy","volume":"101","author":"Verghese C","year":"2008","unstructured":"Verghese C, Ramaswamy B. LMA-supreme--a new single-use LMA with gastric access: a report on its clinical efficacy. Br J Anaesth. 2008, 101:405-10. 10.1093\/bja\/aen174","journal-title":"Br J Anaesth"},{"key":"ref8","unstructured":"LMA protector\u2122 instructions for use. (2015). Accessed. January 7, 2022: http:\/\/www.lmaco-ifu.com\/sites\/default\/files\/node\/1928\/ifu\/revision\/3285\/pbe2100000b-lma-protector-ifuuk.pdf."},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1111\/anae.12902","article-title":"Fewer sore throats and a better seal: why routine manometry for laryngeal mask airways must become the standard of care","volume":"69","author":"Bick E","year":"2014","unstructured":"Bick E, Bailes I, Patel A, Brain AI. Fewer sore throats and a better seal: why routine manometry for laryngeal mask airways must become the standard of care. Anaesthesia. 2014, 69:1304-8. 10.1111\/anae.12902","journal-title":"Anaesthesia"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/80.4.470","article-title":"Appropriate size and inflation of the laryngeal mask airway","volume":"80","author":"Asai T","year":"1998","unstructured":"Asai T, Howell TK, Koga K, Morris S. Appropriate size and inflation of the laryngeal mask airway. Br J Anaesth. 1998, 80:470-4. 10.1093\/bja\/80.4.470","journal-title":"Br J Anaesth"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1111\/anae.12178","article-title":"A randomised, non-crossover study of the guardian CPV\u2122 laryngeal mask versus the LMA supreme\u2122 in paralysed, anaesthetised female patients","volume":"68","author":"Tiefenthaler W","year":"2013","unstructured":"Tiefenthaler W, Eschertzhuber S, Brimacombe J, Fricke E, Keller C, Kaufmann M. A randomised, non-crossover study of the guardian CPV\u2122 laryngeal mask versus the LMA supreme\u2122 in paralysed, anaesthetised female patients. Anaesthesia. 2013, 68:600-4. 10.1111\/anae.12178","journal-title":"Anaesthesia"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.5152\/TJAR.2014.87487","article-title":"The professional experience of anaesthesiologists in proper inflation of laryngeal mask and endotracheal tube cuff","volume":"42","author":"Sara\u00e7o\u011flu A","year":"2014","unstructured":"Sara\u00e7o\u011flu A, Dal D, Pehlivan G, G\u00f6\u011f\u00fc\u015f FY. The professional experience of anaesthesiologists in proper inflation of laryngeal mask and endotracheal tube cuff. Turk J Anaesthesiol Reanim. 2014, 42:234-8. 10.5152\/TJAR.2014.87487","journal-title":"Turk J Anaesthesiol Reanim"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/aew106","article-title":"Value of knowing physical characteristics of the airway device before using it","volume":"117","author":"Van Zundert AA","year":"2016","unstructured":"Van Zundert AA, Skinner MW, Van Zundert TC, Luney SR, Pandit JJ. Value of knowing physical characteristics of the airway device before using it. Br J Anaesth. 2016, 117:12-6. 10.1093\/bja\/aew106","journal-title":"Br J Anaesth"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1097\/00000539-199606000-00017","article-title":"Preoperative airway assessment: predictive value of a multivariate risk index","volume":"82","author":"el-Ganzouri AR","year":"1996","unstructured":"el-Ganzouri AR, McCarthy RJ, Tuman KJ, Tanck EN, Ivankovich AD. Preoperative airway assessment: predictive value of a multivariate risk index. Anesth Analg. 1996, 82:1197-204. 10.1097\/00000539-199606000-00017","journal-title":"Anesth Analg"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.1055\/s-2000-8164","article-title":"A fibreoptic scoring system to assess the position of laryngeal mask airway devices. Interobserver variability and a comparison between the standard, flexible and intubating laryngeal mask airways","volume":"35","author":"Keller C","year":"2000","unstructured":"Keller C, Brimacombe J, P\u00fchringer F. A fibreoptic scoring system to assess the position of laryngeal mask airway devices. Interobserver variability and a comparison between the standard, flexible and intubating laryngeal mask airways. Anasthesiol Intensivmed Notfallmed Schmerzther. 2000, 35:692-4. 10.1055\/s-2000-8164","journal-title":"Anasthesiol Intensivmed Notfallmed Schmerzther"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.1007\/s12630-011-9514-6","article-title":"Oropharyngeal leak pressure with the laryngeal mask airway supreme\u2122 at different intracuff pressures: a randomized controlled trial","volume":"58","author":"Zhang L","year":"2011","unstructured":"Zhang L, Seet E, Mehta V, Subramanyam R, Ankichetty SP, Wong DT, Chung F. Oropharyngeal leak pressure with the laryngeal mask airway supreme\u2122 at different intracuff pressures: a randomized controlled trial. Can J Anaesth. 2011, 58:624-9. 10.1007\/s12630-011-9514-6","journal-title":"Can J Anaesth"},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.1016\/s0197-2456(98)00037-3","article-title":"Power and sample size calculations for studies involving linear regression","volume":"19","author":"Dupont WD","year":"1998","unstructured":"Dupont WD, Plummer WD. Power and sample size calculations for studies involving linear regression. Control Clin Trials. 1998, 19:589-601. 10.1016\/s0197-2456(98)00037-3","journal-title":"Control Clin Trials"},{"key":"ref18","doi-asserted-by":"publisher","DOI":"10.1111\/anae.14534","article-title":"The LMA\u00ae protector\u2122 in anaesthetised, non-paralysed patients: a multicentre prospective observational study","volume":"74","author":"Zaballos M","year":"2019","unstructured":"Zaballos M, Zaballos J, L\u00f3pez S, et al.. The LMA\u00ae protector\u2122 in anaesthetised, non-paralysed patients: a multicentre prospective observational study. Anaesthesia. 2019, 74:333-9. 10.1111\/anae.14534","journal-title":"Anaesthesia"},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.1186\/s12871-019-0785-8","article-title":"A prospective, randomized comparison of the LMA-protector\u2122 and i-gel\u2122 in paralyzed, anesthetized patients","volume":"19","author":"Chang JE","year":"2019","unstructured":"Chang JE, Kim H, Lee JM, Min SW, Won D, Jun K, Hwang JY. A prospective, randomized comparison of the LMA-protector\u2122 and i-gel\u2122 in paralyzed, anesthetized patients. BMC Anesthesiol. 2019, 19:118. 10.1186\/s12871-019-0785-8","journal-title":"BMC Anesthesiol"},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.23736\/S0375-9393.18.12421-7","article-title":"LMA protector\u2122 airway: first experience with a new second generation laryngeal mask","volume":"85","author":"Eckardt F","year":"2019","unstructured":"Eckardt F, Engel J, Mann ST, et al.. LMA protector\u2122 airway: first experience with a new second generation laryngeal mask. Minerva Anestesiol. 2019, 85:45-52. 10.23736\/S0375-9393.18.12421-7","journal-title":"Minerva Anestesiol"},{"key":"ref21","doi-asserted-by":"publisher","DOI":"10.1111\/aas.13256","article-title":"Oropharyngeal leak pressure of the LMA protector\u2122 vs the LMA supreme\u2122; a prospective, randomized, controlled clinical trial","volume":"63","author":"Moser B","year":"2019","unstructured":"Moser B, Keller C, Audig\u00e9 L, Bruppacher HR. Oropharyngeal leak pressure of the LMA protector\u2122 vs the LMA supreme\u2122; a prospective, randomized, controlled clinical trial. Acta Anaesthesiol Scand. 2019, 63:322-8. 10.1111\/aas.13256","journal-title":"Acta Anaesthesiol Scand"},{"key":"ref22","doi-asserted-by":"publisher","DOI":"10.1097\/MD.0000000000002902","article-title":"An evaluation of thyromental distance-based method or weight-based method in determining the size of the laryngeal mask airway supreme: a randomized controlled study","volume":"95","author":"Weng M","year":"2016","unstructured":"Weng M, Ding M, Xu Y, Yang X, Li L, Zhong J, Miao C. An evaluation of thyromental distance-based method or weight-based method in determining the size of the laryngeal mask airway supreme: a randomized controlled study. Medicine (Baltimore). 2016, 95:e2902. 10.1097\/MD.0000000000002902","journal-title":"Medicine (Baltimore)"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/76264-clinical-performance-comparison-of-lma-protector-cuff-pilot-and-lma-supreme-when-used-in-anesthetized-non-paralyzed-patients","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,2,9]],"date-time":"2024-02-09T19:35:28Z","timestamp":1707507328000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/76264-clinical-performance-comparison-of-lma-protector-cuff-pilot-and-lma-supreme-when-used-in-anesthetized-non-paralyzed-patients"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,3,15]]},"references-count":22,"URL":"https:\/\/doi.org\/10.7759\/cureus.23176","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2022,3,15]]}}}