{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,9]],"date-time":"2026-04-09T03:35:15Z","timestamp":1775705715143,"version":"3.50.1"},"reference-count":23,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2022,7,15]]},"DOI":"10.7759\/cureus.26895","type":"journal-article","created":{"date-parts":[[2022,7,15]],"date-time":"2022-07-15T18:21:16Z","timestamp":1657909276000},"source":"Crossref","is-referenced-by-count":3,"title":["Type III Endoleak Leading to Aortic Rupture After Endovascular Repair"],"prefix":"10.7759","author":[{"given":"Yahia","family":"Suliemeh","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mahmoud","family":"Bouabane","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mohammad","family":"Deershamarkha","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Adnan","family":"Benzirar","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Omar","family":"El Mahi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvs.2007.04.016","article-title":"Endoleaks after endovascular aneurysm repair lead to nonuniform intra-aneurysm sac pressure","volume":"46","author":"Dias NV","year":"2007","unstructured":"Dias NV, Ivancev K, Resch TA, Malina M, Sonesson B. Endoleaks after endovascular aneurysm repair lead to nonuniform intra-aneurysm sac pressure. J Vasc Surg. 2007, 46:197-203. 10.1016\/j.jvs.2007.04.016","journal-title":"J Vasc Surg"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1001\/archsurg.1995.01430050099017","article-title":"Transfemoral, endovascular stented graft repair of an abdominal aortic aneurysm","volume":"130","author":"Parodi JC","year":"1995","unstructured":"Parodi JC, Marin ML, Veith FJ. Transfemoral, endovascular stented graft repair of an abdominal aortic aneurysm. Arch Surg. 1995, 130:549-52. 10.1001\/archsurg.1995.01430050099017","journal-title":"Arch Surg"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1583\/11-3762R.1","article-title":"Current evidence is insufficient to define an optimal threshold for intervention in isolated type II endoleak after endovascular aneurysm repair","volume":"19","author":"Karthikesalingam A","year":"2012","unstructured":"Karthikesalingam A, Thrumurthy SG, Jackson D, et al.. Current evidence is insufficient to define an optimal threshold for intervention in isolated type II endoleak after endovascular aneurysm repair. J Endovasc Ther. 2012, 19:200-8. 10.1583\/11-3762R.1","journal-title":"J Endovasc Ther"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1583\/1074-6218(1997)004<0152:EAACOE>2.0.CO;2","article-title":"Endoleak as a complication of endoluminal grafting of abdominal aortic aneurysms: classification, incidence, diagnosis, and management","volume":"4","author":"White GH","year":"1997","unstructured":"White GH, Yu W, May J, Chaufour X, Stephen MS. Endoleak as a complication of endoluminal grafting of abdominal aortic aneurysms: classification, incidence, diagnosis, and management. J Endovas Surg. 1997, 4:152-68. 10.1583\/1074-6218(1997)004&lt;0152:EAACOE&gt;2.0.CO;2","journal-title":"J Endovas Surg"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1067\/mva.2002.123763","article-title":"Reporting standards for endovascular aortic aneurysm repair","volume":"35","author":"Chaikof EL","year":"2002","unstructured":"Chaikof EL, Blankensteijn JD, Harris PL, et al.. Reporting standards for endovascular aortic aneurysm repair. J Vasc Surg. 2002, 35:1048-60. 10.1067\/mva.2002.123763","journal-title":"J Vasc Surg"},{"key":"ref6","article-title":"Pre- and post-aortic endovascular interventions: what a radiologist needs to know","author":"Bley T","year":"2019","unstructured":"Bley T, Roos J. Pre- and post-aortic endovascular interventions: what a radiologist needs to know. Diseases of the Chest, Breast, Heart and Vessels 2019-2022: Diagnostic and Interventional Imaging [Internet]. Hodler J, Kubik-Huch RA, von Schulthess GK (ed): Springer Nature, Cham, Switzerland; 2019."},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvs.2006.05.041","article-title":"Endoleaks after endovascular repair of thoracic aortic aneurysms","volume":"44","author":"Parmer SS","year":"2006","unstructured":"Parmer SS, Carpenter JP, Stavropoulos SW, et al.. Endoleaks after endovascular repair of thoracic aortic aneurysms. J Vasc Surg. 2006, 44:447-52. 10.1016\/j.jvs.2006.05.041","journal-title":"J Vasc Surg"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1067\/mva.2002.118823","article-title":"Significance of endoleaks after endovascular repair of abdominal aortic aneurysms: The EUROSTAR experience","volume":"35","author":"van Marrewijk C","year":"2002","unstructured":"van Marrewijk C, Buth J, Harris PL, Norgren L, Nevelsteen A, Wyatt MG. Significance of endoleaks after endovascular repair of abdominal aortic aneurysms: The EUROSTAR experience. J Vasc Surg. 2002, 35:461-73. 10.1067\/mva.2002.118823","journal-title":"J Vasc Surg"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvs.2017.01.056","article-title":"Incidence, etiology, and management of type III endoleak after endovascular aortic repair","volume":"66","author":"Maleux G","year":"2017","unstructured":"Maleux G, Poorteman L, Laenen A, Saint-L\u00e8bes B, Houthoofd S, Fourneau I, Rousseau H. Incidence, etiology, and management of type III endoleak after endovascular aortic repair. J Vasc Surg. 2017, 66:1056-64. 10.1016\/j.jvs.2017.01.056","journal-title":"J Vasc Surg"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1067\/mva.2000.109990","article-title":"Incidence and risk factors of late rupture, conversion, and death after endovascular repair of infrarenal aortic aneurysms: the EUROSTAR experience. European Collaborators on stent\/graft techniques for aortic aneurysm repair","volume":"32","author":"Harris PL","year":"2000","unstructured":"Harris PL, Vallabhaneni SR, Desgranges P, Becquemin JP, van Marrewijk C, Laheij RJ. Incidence and risk factors of late rupture, conversion, and death after endovascular repair of infrarenal aortic aneurysms: the EUROSTAR experience. European Collaborators on stent\/graft techniques for aortic aneurysm repair. J Vasc Surg. 2000, 32:739-49. 10.1067\/mva.2000.109990","journal-title":"J Vasc Surg"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1016\/s1051-0443(07)61042-2","article-title":"Type III endoleak caused by fabric tear of a Zenith endograft after low-pressure balloon modeling","volume":"16","author":"Vliet JA","year":"2005","unstructured":"Vliet JA, Blankensteijn JD, Kool LJ. Type III endoleak caused by fabric tear of a Zenith endograft after low-pressure balloon modeling. J Vasc Interv Radiol. 2005, 16:1042-44. 10.1016\/s1051-0443(07)61042-2","journal-title":"J Vasc Interv Radiol"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1053\/ejvs.1998.0807","article-title":"Fate of endoleaks after endoluminal repair of abdominal aortic aneurysms with the EVT device","volume":"18","author":"Makaroun M","year":"1999","unstructured":"Makaroun M, Zajko A, Sugimoto H, Eskandari M, Webster M. Fate of endoleaks after endoluminal repair of abdominal aortic aneurysms with the EVT device. Eur J Vasc Endovasc Surg. 1999, 18:185-90. 10.1053\/ejvs.1998.0807","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1067\/mva.2001.111807","article-title":"Aneurysm sac pressure measurements after endovascular repair of abdominal aortic aneurysms","volume":"33","author":"Baum RA","year":"2001","unstructured":"Baum RA, Carpenter JP, Cope C, et al.. Aneurysm sac pressure measurements after endovascular repair of abdominal aortic aneurysms. J Vasc Surg. 2001, 33:32-41. 10.1067\/mva.2001.111807","journal-title":"J Vasc Surg"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1177\/152660280000700404","article-title":"Midterm changes in aortic aneurysm morphology after endovascular repair","volume":"7","author":"Resch T","year":"2000","unstructured":"Resch T, Ivancev K, Brunkwall J, Nirhov N, Malina M, Lindblad B. Midterm changes in aortic aneurysm morphology after endovascular repair. J Endovasc Ther. 2000, 7:279-85. 10.1177\/152660280000700404","journal-title":"J Endovasc Ther"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2433051649","article-title":"Imaging techniques for detection and management of endoleaks after endovascular aortic aneurysm repair","volume":"243","author":"Stavropoulos SW","year":"2007","unstructured":"Stavropoulos SW, Charagundla SR. Imaging techniques for detection and management of endoleaks after endovascular aortic aneurysm repair. Radiology. 2007, 243:641-55. 10.1148\/radiol.2433051649","journal-title":"Radiology"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.1016\/S0741-5214(98)70172-7","article-title":"Modular component separation and reperfusion of abdominal aortic aneurysm sac after endovascular repair of the abdominal aortic aneurysm: a case report","volume":"28","author":"G","year":"1998","unstructured":"G, Rousseau H, Otal P, Colombier D, Glock Y, Joffre F. Modular component separation and reperfusion of abdominal aortic aneurysm sac after endovascular repair of the abdominal aortic aneurysm: a case report. J Vasc Surg. 1998, 28:349-52. 10.1016\/S0741-5214(98)70172-7","journal-title":"J Vasc Surg"},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.1583\/10-3086.1","article-title":"Long-term follow-up of secondary interventions after endovascular aneurysm repair with the AneuRx endoprosthesis: a single-center experience","volume":"17","author":"van Lammeren GW","year":"2010","unstructured":"van Lammeren GW, Fioole B, Waasdorp EJ, Moll FL, van Herwaarden JA, de Vries JP. Long-term follow-up of secondary interventions after endovascular aneurysm repair with the AneuRx endoprosthesis: a single-center experience. J Endovasc Ther. 2010, 17:408-15. 10.1583\/10-3086.1","journal-title":"J Endovasc Ther"},{"key":"ref18","doi-asserted-by":"publisher","DOI":"10.1016\/S0033-8389(02)00024-6","article-title":"Imaging of aortic stent-grafts and endoleaks","volume":"40","author":"Thurnher S","year":"2002","unstructured":"Thurnher S, Cejna M. Imaging of aortic stent-grafts and endoleaks. Radiol Clin North Am. 2002, 40:799-833. 10.1016\/S0033-8389(02)00024-6","journal-title":"Radiol Clin North Am"},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.1067\/mva.2003.17","article-title":"Efficacy of ultrasound scan contrast agents in the noninvasive follow-up of aortic stent grafts","volume":"37","author":"Bendick PJ","year":"2003","unstructured":"Bendick PJ, Bove PG, Long GW, Zelenock GB, Brown OW, Shanley CJ. Efficacy of ultrasound scan contrast agents in the noninvasive follow-up of aortic stent grafts. J Vasc Surg. 2003, 37:381-5. 10.1067\/mva.2003.17","journal-title":"J Vasc Surg"},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.1053\/ejvs.1999.1029","article-title":"Freedom from endoleak after endovascular aneurysm repair does not equal treatment success","volume":"19","author":"Gilling-Smith GL","year":"2000","unstructured":"Gilling-Smith GL, Martin J, Sudhindran S, et al.. Freedom from endoleak after endovascular aneurysm repair does not equal treatment success. Eur J Vasc Endovasc Surg. 2000, 19:421-5. 10.1053\/ejvs.1999.1029","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"ref21","doi-asserted-by":"publisher","DOI":"10.1177\/152660289900600402","article-title":"Endotension: an explanation for continued AAA growth after successful endoluminal repair","volume":"6","author":"White GH","year":"1999","unstructured":"White GH, May J, Petrasek P, Waugh R, Stephen M, Harris J. Endotension: an explanation for continued AAA growth after successful endoluminal repair. J Endovasc Surg. 1999, 6:308-15. 10.1177\/152660289900600402","journal-title":"J Endovasc Surg"},{"key":"ref22","doi-asserted-by":"publisher","DOI":"10.1007\/s10016-001-0395-y","article-title":"Treatment of type III endoleak with an aortouniiliac stent graft","volume":"17","author":"Teruya TH","year":"2003","unstructured":"Teruya TH, Ayerdi J, Solis MM, Abou-Zamzam AM, Ballard JL, McLafferty RB, Hodgson KJ. Treatment of type III endoleak with an aortouniiliac stent graft. Ann Vasc Surg. 2003, 17:123-8. 10.1007\/s10016-001-0395-y","journal-title":"Ann Vasc Surg"},{"key":"ref23","unstructured":"Identifying and managing type III endoleak after EVAR. (2019). https.\/\/evtoday.com\/articles\/2019-jan\/identifying-and-managing-type-iii-endoleak-after-evar."}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/101773-type-iii-endoleak-leading-to-aortic-rupture-after-endovascular-repair","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,2,9]],"date-time":"2024-02-09T19:44:37Z","timestamp":1707507877000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/101773-type-iii-endoleak-leading-to-aortic-rupture-after-endovascular-repair"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,7,15]]},"references-count":23,"URL":"https:\/\/doi.org\/10.7759\/cureus.26895","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2022,7,15]]}}}