{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,12]],"date-time":"2025-12-12T13:42:26Z","timestamp":1765546946118},"reference-count":15,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2022,8,21]]},"DOI":"10.7759\/cureus.28226","type":"journal-article","created":{"date-parts":[[2022,8,21]],"date-time":"2022-08-21T13:08:20Z","timestamp":1661087300000},"source":"Crossref","is-referenced-by-count":1,"title":["Transcatheter Closure of a Patent Ductus Arteriosus Using a Piccolo Duct Occluder"],"prefix":"10.7759","author":[{"given":"Pranjit","family":"Deb","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anindya","family":"Benerjee","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tapas","family":"Som","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ramachandra","family":"Barik","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1007\/s00246-017-1768-5","article-title":"Surgical ligation versus percutaneous closure of patent ductus arteriosus in very low-weight preterm infants: which are the real benefits of the percutaneous approach?","volume":"39","author":"Rodr\u00edguez Ogando A","year":"2018","unstructured":"Rodr\u00edguez Ogando A, Planelles Asensio I, de la Blanca AR, et al.. Surgical ligation versus percutaneous closure of patent ductus arteriosus in very low-weight preterm infants: which are the real benefits of the percutaneous approach?. Pediatr Cardiol. 2018, 39:398-410. 10.1007\/s00246-017-1768-5","journal-title":"Pediatr Cardiol"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1111\/chd.12700","article-title":"Can transcatheter PDA closure be performed in neonates \u22641000 grams? The Memphis experience","volume":"14","author":"Sathanandam S","year":"2019","unstructured":"Sathanandam S, Agrawal H, Chilakala S, et al.. Can transcatheter PDA closure be performed in neonates \u22641000 grams? The Memphis experience. Congenit Heart Dis. 2019, 14:79-84. 10.1111\/chd.12700","journal-title":"Congenit Heart Dis"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.3389\/fped.2020.590578","article-title":"Management of patent ductus arteriosus in premature infants in 2020","volume":"8","author":"Parkerson S","year":"2020","unstructured":"Parkerson S, Philip R, Talati A, Sathanandam S. Management of patent ductus arteriosus in premature infants in 2020. Front Pediatr. 2020, 8:590578. 10.3389\/fped.2020.590578","journal-title":"Front Pediatr"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.28973","article-title":"Amplatzer Piccolo Occluder clinical trial for percutaneous closure of the patent ductus arteriosus in patients \u2265700 grams","volume":"96","author":"Sathanandam SK","year":"2020","unstructured":"Sathanandam SK, Gutfinger D, O'Brien L, et al.. Amplatzer Piccolo Occluder clinical trial for percutaneous closure of the patent ductus arteriosus in patients \u2265700 grams. Catheter Cardiovasc Interv. 2020, 96:1266-76. 10.1002\/ccd.28973","journal-title":"Catheter Cardiovasc Interv"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCINTERVENTIONS.121.010600","article-title":"Single-center experience of 100 consecutive percutaneous patent ductus arteriosus closures in infants \u22641000 grams","volume":"14","author":"Philip R","year":"2021","unstructured":"Philip R, Tailor N, Johnson JN, et al.. Single-center experience of 100 consecutive percutaneous patent ductus arteriosus closures in infants \u22641000 grams. Circ Cardiovasc Interv. 2021, 14:e010600. 10.1161\/CIRCINTERVENTIONS.121.010600","journal-title":"Circ Cardiovasc Interv"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijcard.2020.02.065","article-title":"Device deformation and left pulmonary artery obstruction after transcatheter patent ductus arteriosus closure in preterm infants","volume":"312","author":"Chien YH","year":"2020","unstructured":"Chien YH, Wang HH, Lin MT, et al.. Device deformation and left pulmonary artery obstruction after transcatheter patent ductus arteriosus closure in preterm infants. Int J Cardiol. 2020, 312:50-5. 10.1016\/j.ijcard.2020.02.065","journal-title":"Int J Cardiol"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.28502","article-title":"Percutaneous closure of patent ductus arteriosus in premature infants: a French national survey","volume":"95","author":"Malekzadeh-Milani S","year":"2020","unstructured":"Malekzadeh-Milani S, Akhavi A, Douchin S, et al.. Percutaneous closure of patent ductus arteriosus in premature infants: a French national survey. Catheter Cardiovasc Interv. 2020, 95:71-7. 10.1002\/ccd.28502","journal-title":"Catheter Cardiovasc Interv"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.28942","article-title":"Incidence and fate of device-related left pulmonary artery stenosis and aortic coarctation in small infants undergoing transcatheter patent ductus arteriosus closure","volume":"96","author":"Tomasulo CE","year":"2020","unstructured":"Tomasulo CE, Gillespie MJ, Munson D, et al.. Incidence and fate of device-related left pulmonary artery stenosis and aortic coarctation in small infants undergoing transcatheter patent ductus arteriosus closure. Catheter Cardiovasc Interv. 2020, 96:889-97. 10.1002\/ccd.28942","journal-title":"Catheter Cardiovasc Interv"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1017\/S1047951121005035","article-title":"Aortic migration of Amplatzer Piccolo\u2122 ductal Occluder","volume":"32","author":"Minocha PK","year":"2022","unstructured":"Minocha PK, Sutton N, Crawford MT, et al.. Aortic migration of Amplatzer Piccolo\u2122 ductal Occluder. Cardiol Young. 2022, 32:1353-6. 10.1017\/S1047951121005035","journal-title":"Cardiol Young"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1007\/s00246-021-02665-3","article-title":"Consensus guidelines for the prevention and management of periprocedural complications of transcatheter patent ductus arteriosus closure with the Amplatzer Piccolo Occluder in extremely low birth weight infants","volume":"42","author":"Sathanandam S","year":"2021","unstructured":"Sathanandam S, Gutfinger D, Morray B, et al.. Consensus guidelines for the prevention and management of periprocedural complications of transcatheter patent ductus arteriosus closure with the Amplatzer Piccolo Occluder in extremely low birth weight infants. Pediatr Cardiol. 2021, 42:1258-74. 10.1007\/s00246-021-02665-3","journal-title":"Pediatr Cardiol"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1016\/j.iccl.2018.08.004","article-title":"New patent ductus arteriosus closure devices and techniques","volume":"8","author":"Agrawal H","year":"2019","unstructured":"Agrawal H, Waller BR 3rd, Surendan S, Sathanandam S. New patent ductus arteriosus closure devices and techniques. Interv Cardiol Clin. 2019, 8:23-32. 10.1016\/j.iccl.2018.08.004","journal-title":"Interv Cardiol Clin"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1111\/chd.12725","article-title":"Echocardiographic guidance for transcatheter patent ductus arteriosus closure in extremely low birth weight infants","volume":"14","author":"Johnson JN","year":"2019","unstructured":"Johnson JN, Sathanandam S, Naik R, Philip R. Echocardiographic guidance for transcatheter patent ductus arteriosus closure in extremely low birth weight infants. Congenit Heart Dis. 2019, 14:74-8. 10.1111\/chd.12725","journal-title":"Congenit Heart Dis"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1016\/j.echo.2021.06.005","article-title":"Echocardiographic versus angiographic measurement of the patent ductus arteriosus in extremely low birth weight infants and the utility of echo guidance for transcatheter closure","volume":"34","author":"Paudel G","year":"2021","unstructured":"Paudel G, Johnson JN, Philip R, et al.. Echocardiographic versus angiographic measurement of the patent ductus arteriosus in extremely low birth weight infants and the utility of echo guidance for transcatheter closure. J Am Soc Echocardiogr. 2021, 34:1086-94. 10.1016\/j.echo.2021.06.005","journal-title":"J Am Soc Echocardiogr"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.26287","article-title":"Morphologic characterization of the patent ductus arteriosus in the premature infant and the choice of transcatheter occlusion device","volume":"87","author":"Philip R","year":"2016","unstructured":"Philip R, Waller BR 3rd, Agrawal V, Wright D, Arevalo A, Zurakowski D, Sathanandam S. Morphologic characterization of the patent ductus arteriosus in the premature infant and the choice of transcatheter occlusion device. Catheter Cardiovasc Interv. 2016, 87:310-7. 10.1002\/ccd.26287","journal-title":"Catheter Cardiovasc Interv"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.1016\/s0735-1097(00)01094-9","article-title":"The Amplatzer duct occluder: experience in 209 patients","volume":"37","author":"Bilkis AA","year":"2001","unstructured":"Bilkis AA, Alwi M, Hasri S, Haifa AL, Geetha K, Rehman MA, Hasanah I. The Amplatzer duct occluder: experience in 209 patients. J Am Coll Cardiol. 2001, 37:258-61. 10.1016\/s0735-1097(00)01094-9","journal-title":"J Am Coll Cardiol"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/110607-transcatheter-closure-of-a-patent-ductus-arteriosus-using-a-piccolo-duct-occluder","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,2,9]],"date-time":"2024-02-09T19:38:32Z","timestamp":1707507512000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/110607-transcatheter-closure-of-a-patent-ductus-arteriosus-using-a-piccolo-duct-occluder"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,8,21]]},"references-count":15,"URL":"https:\/\/doi.org\/10.7759\/cureus.28226","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2022,8,21]]}}}