{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,2,10]],"date-time":"2024-02-10T00:28:42Z","timestamp":1707524922630},"reference-count":20,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2023,2,21]]},"DOI":"10.7759\/cureus.35279","type":"journal-article","created":{"date-parts":[[2023,2,21]],"date-time":"2023-02-21T23:54:47Z","timestamp":1677023687000},"source":"Crossref","is-referenced-by-count":1,"title":["Invasive Intracranial Electroencephalogram (EEG) Monitoring for Epilepsy in the Pediatric Patient With a Shunt"],"prefix":"10.7759","author":[{"given":"Muhammad","family":"El Shatanofy","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Katherine","family":"Hofmann","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"John S","family":"Myseros","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"William D","family":"Gaillard","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Robert F","family":"Keating","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chima","family":"Oluigbo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1016\/j.spen.2021.100917","article-title":"The missed value of underutilizing pediatric epilepsy surgery: a systematic review","volume":"39","author":"Beatty CW","year":"2021","unstructured":"Beatty CW, Lockrow JP, Gedela S, Gehred A, Ostendorf AP. The missed value of underutilizing pediatric epilepsy surgery: a systematic review. Semin Pediatr Neurol. 2021, 39:100917. 10.1016\/j.spen.2021.100917","journal-title":"Semin Pediatr Neurol"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1007\/s00381-021-05403-5","article-title":"Virtual reality-based 3-dimensional localization of stereotactic EEG (SEEG) depth electrodes and related brain anatomy in pediatric epilepsy surgery","volume":"38","author":"Phan TN","year":"2022","unstructured":"Phan TN, Prakash KJ, Elliott RS, Pasupuleti A, Gaillard WD, Keating RF, Oluigbo CO. Virtual reality-based 3-dimensional localization of stereotactic EEG (SEEG) depth electrodes and related brain anatomy in pediatric epilepsy surgery. Childs Nerv Syst. 2022, 38:537-546. 10.1007\/s00381-021-05403-5","journal-title":"Childs Nerv Syst"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1007\/s003810000381","article-title":"Hydrocephalus and epilepsy","volume":"17","author":"Sato O","year":"2001","unstructured":"Sato O, Yamguchi T, Kittaka M, Toyama H. Hydrocephalus and epilepsy. Childs Nerv Syst. 2001, 17:76-86. 10.1007\/s003810000381","journal-title":"Childs Nerv Syst"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1111\/epi.12912","article-title":"Increasing utilization of pediatric epilepsy surgery in the United States between 1997 and 2009","volume":"56","author":"Pestana Knight EM","year":"2015","unstructured":"Pestana Knight EM, Schiltz NK, Bakaki PM, Koroukian SM, Lhatoo SD, Kaiboriboon K. Increasing utilization of pediatric epilepsy surgery in the United States between 1997 and 2009. Epilepsia. 2015, 56:375-381. 10.1111\/epi.12912","journal-title":"Epilepsia"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1007\/s00381-006-0127-2","article-title":"Stereo-EEG in children","volume":"22","author":"Cossu M","year":"2006","unstructured":"Cossu M, Cardinale F, Castana L, Nobili L, Sartori I, Lo Russo G. Stereo-EEG in children. Childs Nerv Syst. 2006, 22:766-778. 10.1007\/s00381-006-0127-2","journal-title":"Childs Nerv Syst"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1227\/NEU.0000000000000453","article-title":"Stereoelectroencephalography in children and adolescents with difficult-to-localize refractory focal epilepsy","volume":"75","author":"Gonzalez-Martinez J","year":"2014","unstructured":"Gonzalez-Martinez J, Mullin J, Bulacio J, et al.. Stereoelectroencephalography in children and adolescents with difficult-to-localize refractory focal epilepsy. Neurosurgery. 2014, 75:258-268; discussion 267-268. 10.1227\/NEU.0000000000000453","journal-title":"Neurosurgery"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1097\/WNP.0b013e31827edca4","article-title":"Noninvasive predictors of subdural grid seizure localization in children with nonlesional focal epilepsy","volume":"30","author":"Kalamangalam GP","year":"2013","unstructured":"Kalamangalam GP, Pestana Knight EM, Visweswaran S, Gupta A. Noninvasive predictors of subdural grid seizure localization in children with nonlesional focal epilepsy. J Clin Neurophysiol. 2013, 30:45-50. 10.1097\/WNP.0b013e31827edca4","journal-title":"J Clin Neurophysiol"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1111\/epi.13685","article-title":"Subdural grid and depth electrode monitoring in pediatric patients","volume":"58","author":"Skoch J","year":"2017","unstructured":"Skoch J, Adelson PD, Bhatia S, Greiner HM, Rydenhag B, Scavarda D, Mangano FT. Subdural grid and depth electrode monitoring in pediatric patients. Epilepsia. 2017, 58:56-65. 10.1111\/epi.13685","journal-title":"Epilepsia"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1227\/01.NEU.0000324996.37228.F8","article-title":"Intracranial electroencephalography with subdural grid electrodes: techniques, complications, and outcomes","volume":"63","author":"Van Gompel JJ","year":"2008","unstructured":"Van Gompel JJ, Worrell GA, Bell ML, et al.. Intracranial electroencephalography with subdural grid electrodes: techniques, complications, and outcomes. Neurosurgery. 2008, 63:498-505; discussion 505-506. 10.1227\/01.NEU.0000324996.37228.F8","journal-title":"Neurosurgery"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.3171\/ped.2006.105.5.343","article-title":"Complications of invasive subdural electrode monitoring at St. Louis Children's Hospital, 1994-2005","volume":"105","author":"Johnston JM Jr","year":"2006","unstructured":"Johnston JM Jr, Mangano FT, Ojemann JG, Park TS, Trevathan E, Smyth MD. Complications of invasive subdural electrode monitoring at St. Louis Children's Hospital, 1994-2005. J Neurosurg. 2006, 105:343-347. 10.3171\/ped.2006.105.5.343","journal-title":"J Neurosurg"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1111\/epi.13298","article-title":"Is SEEG safe? A systematic review and meta-analysis of stereo-electroencephalography-related complications","volume":"57","author":"Mullin JP","year":"2016","unstructured":"Mullin JP, Shriver M, Alomar S, Najm I, Bulacio J, Chauvel P, Gonzalez-Martinez J. Is SEEG safe? A systematic review and meta-analysis of stereo-electroencephalography-related complications. Epilepsia. 2016, 57:386-401. 10.1111\/epi.13298","journal-title":"Epilepsia"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1159\/000452840","article-title":"Cerebrospinal fluid shunting complications in children","volume":"52","author":"Hanak BW","year":"2017","unstructured":"Hanak BW, Bonow RH, Harris CA, Browd SR. Cerebrospinal fluid shunting complications in children. Pediatr Neurosurg. 2017, 52:381-400. 10.1159\/000452840","journal-title":"Pediatr Neurosurg"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1007\/s00381-021-05051-9","article-title":"Neurodevelopmental outcomes after ventriculoperitoneal shunt placement in children with non-infectious hydrocephalus: a meta-analysis","volume":"37","author":"Sobana M","year":"2021","unstructured":"Sobana M, Halim D, Aviani JK, Gamayani U, Achmad TH. Neurodevelopmental outcomes after ventriculoperitoneal shunt placement in children with non-infectious hydrocephalus: a meta-analysis. Childs Nerv Syst. 2021, 37:1055-1065. 10.1007\/s00381-021-05051-9","journal-title":"Childs Nerv Syst"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.3171\/2017.10.JNS17439","article-title":"Global hydrocephalus epidemiology and incidence: systematic review and meta-analysis","volume":"130","author":"Dewan MC","year":"2018","unstructured":"Dewan MC, Rattani A, Mekary R, et al.. Global hydrocephalus epidemiology and incidence: systematic review and meta-analysis. J Neurosurg. 2018, 130:1065-1079. 10.3171\/2017.10.JNS17439","journal-title":"J Neurosurg"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.2176\/nmc.45.600","article-title":"Intractable seizures associated with proximal migration of a ventriculoperitoneal shunt. Case report","volume":"45","author":"Yamazaki T","year":"2005","unstructured":"Yamazaki T, Shimizu S, Sagiuchi T, Iwasaki T, Utsuki S, Suzuki S, Fujii K. Intractable seizures associated with proximal migration of a ventriculoperitoneal shunt. Case report. Neurol Med Chir (Tokyo). 2005, 45:600-603. 10.2176\/nmc.45.600","journal-title":"Neurol Med Chir (Tokyo)"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.1016\/j.pediatrneurol.2016.02.011","article-title":"Clinical and surgical factors associated with increased epilepsy risk in children with hydrocephalus","volume":"59","author":"Tully HM","year":"2016","unstructured":"Tully HM, Kukull WA, Mueller BA. Clinical and surgical factors associated with increased epilepsy risk in children with hydrocephalus. Pediatr Neurol. 2016, 59:18-22. 10.1016\/j.pediatrneurol.2016.02.011","journal-title":"Pediatr Neurol"},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.1111\/j.1528-1167.2012.03545.x","article-title":"Risks and benefits of invasive epilepsy surgery workup with implanted subdural and depth electrodes","volume":"53","author":"Wellmer J","year":"2012","unstructured":"Wellmer J, von der Groeben F, Klarmann U, et al.. Risks and benefits of invasive epilepsy surgery workup with implanted subdural and depth electrodes. Epilepsia. 2012, 53:1322-1332. 10.1111\/j.1528-1167.2012.03545.x","journal-title":"Epilepsia"},{"key":"ref18","doi-asserted-by":"publisher","DOI":"10.3171\/2018.6.FOCUS18209","article-title":"Early outcomes of stereoelectroencephalography followed by MR-guided laser interstitial thermal therapy: a paradigm for minimally invasive epilepsy surgery","volume":"45","author":"Cobourn K","year":"2018","unstructured":"Cobourn K, Fayed I, Keating RF, Oluigbo CO. Early outcomes of stereoelectroencephalography followed by MR-guided laser interstitial thermal therapy: a paradigm for minimally invasive epilepsy surgery. Neurosurg Focus. 2018, 45:E8. 10.3171\/2018.6.FOCUS18209","journal-title":"Neurosurg Focus"},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.1111\/epi.13503","article-title":"Complications of subdural and depth electrodes in 269 patients undergoing 317 procedures for invasive monitoring in epilepsy","volume":"57","author":"Schmidt RF","year":"2016","unstructured":"Schmidt RF, Wu C, Lang MJ, et al.. Complications of subdural and depth electrodes in 269 patients undergoing 317 procedures for invasive monitoring in epilepsy. Epilepsia. 2016, 57:1697-1708. 10.1111\/epi.13503","journal-title":"Epilepsia"},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.3171\/2015.5.PEDS15130","article-title":"What is the risk of a shunt malfunction after elective intradural surgery?","volume":"16","author":"Venable GT","year":"2015","unstructured":"Venable GT, Green CS, Smalley ZS, Bedford EC, Modica JS, Klimo P Jr. What is the risk of a shunt malfunction after elective intradural surgery?. J Neurosurg Pediatr. 2015, 16:642-647. 10.3171\/2015.5.PEDS15130","journal-title":"J Neurosurg Pediatr"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/137753-invasive-intracranial-electroencephalogram-eeg-monitoring-for-epilepsy-in-the-pediatric-patient-with-a-shunt","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,2,9]],"date-time":"2024-02-09T19:51:33Z","timestamp":1707508293000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/137753-invasive-intracranial-electroencephalogram-eeg-monitoring-for-epilepsy-in-the-pediatric-patient-with-a-shunt"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,2,21]]},"references-count":20,"URL":"https:\/\/doi.org\/10.7759\/cureus.35279","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2023,2,21]]}}}