{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,22]],"date-time":"2025-10-22T18:25:01Z","timestamp":1761157501729},"reference-count":30,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2023,2,28]]},"DOI":"10.7759\/cureus.35616","type":"journal-article","created":{"date-parts":[[2023,3,1]],"date-time":"2023-03-01T02:15:18Z","timestamp":1677636918000},"source":"Crossref","is-referenced-by-count":2,"title":["Accuracy Verification of Four-Dimensional CT Analysis of Knee Joint Movements: A Pilot Study Using a Knee Joint Model and Motion-Capture System"],"prefix":"10.7759","author":[{"given":"Takuya","family":"Adachi","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yuki","family":"Kato","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dai","family":"Kiyotomo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Katsushige","family":"Kawamukai","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shuzo","family":"Takazawa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takahiro","family":"Suzuki","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Youichi","family":"Machida","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1007\/s00774-009-0080-8","article-title":"Prevalence of knee osteoarthritis, lumbar spondylosis, and osteoporosis in Japanese men and women: the research on osteoarthritis\/osteoporosis against disability study","volume":"27","author":"Yoshimura N","year":"2009","unstructured":"Yoshimura N, Muraki S, Oka H, et al.. Prevalence of knee osteoarthritis, lumbar spondylosis, and osteoporosis in Japanese men and women: the research on osteoarthritis\/osteoporosis against disability study. J Bone Miner Metab. 2009, 27:620-628. 10.1007\/s00774-009-0080-8","journal-title":"J Bone Miner Metab"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1016\/S0883-5403(96)80183-5","article-title":"Functional outcome and patient satisfaction in total knee patients over the age of 75","volume":"11","author":"Anderson JG","year":"1996","unstructured":"Anderson JG, Wixson RL, Tsai D, Stulberg SD, Chang RW. Functional outcome and patient satisfaction in total knee patients over the age of 75. J Arthroplasty. 1996, 11:831-840. 10.1016\/S0883-5403(96)80183-5","journal-title":"J Arthroplasty"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1007\/s11999-009-1119-9","article-title":"Patient satisfaction after total knee arthroplasty: who is satisfied and who is not?","volume":"468","author":"Bourne RB","year":"2010","unstructured":"Bourne RB, Chesworth BM, Davis AM, Mahomed NN, Charron KD. Patient satisfaction after total knee arthroplasty: who is satisfied and who is not?. Clin Orthop Relat Res. 2010, 468:57-63. 10.1007\/s11999-009-1119-9","journal-title":"Clin Orthop Relat Res"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2017.09.041","article-title":"Failure after modern total knee arthroplasty: a prospective study of 18,065 knees","volume":"33","author":"Pitta M","year":"2018","unstructured":"Pitta M, Esposito CI, Li Z, Lee YY, Wright TM, Padgett DE. Failure after modern total knee arthroplasty: a prospective study of 18,065 knees. J Arthroplasty. 2018, 33:407-414. 10.1016\/j.arth.2017.09.041","journal-title":"J Arthroplasty"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.H.01408","article-title":"Gait mechanics influence healthy cartilage morphology and osteoarthritis of the knee","volume":"91","author":"Andriacchi TP","year":"2009","unstructured":"Andriacchi TP, Koo S, Scanlan SF. Gait mechanics influence healthy cartilage morphology and osteoarthritis of the knee. J Bone Joint Surg Am. 2009, 91:95-101. 10.2106\/JBJS.H.01408","journal-title":"J Bone Joint Surg Am"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1109\/TPAMI.1980.6447705","article-title":"Towards a system for the interpretation of moving light displays","volume":"2","author":"Rashid RF","year":"1980","unstructured":"Rashid RF. Towards a system for the interpretation of moving light displays. IEEE Trans Pattern Anal Mach Intell. 1980, 2:574-581. 10.1109\/TPAMI.1980.6447705","journal-title":"IEEE Trans Pattern Anal Mach Intell"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1016\/0167-9457(91)90047-2","article-title":"Three-dimensional analysis of human walking: experimental methods and associated artifacts","volume":"10","author":"Cappozzo A","year":"1991","unstructured":"Cappozzo A. Three-dimensional analysis of human walking: experimental methods and associated artifacts. Hum Mov Sci. 1991, 10:589-602. 10.1016\/0167-9457(91)90047-2","journal-title":"Hum Mov Sci"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1109\/10.649988","article-title":"Surface-marker cluster design criteria for 3-D bone movement reconstruction","volume":"44","author":"Cappozzo A","year":"1997","unstructured":"Cappozzo A, Cappello A, Croce UD, Pensalfini F. Surface-marker cluster design criteria for 3-D bone movement reconstruction. IEEE Trans Biomed Eng. 1997, 44:1165-1174. 10.1109\/10.649988","journal-title":"IEEE Trans Biomed Eng"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1016\/S0966-6362(97)01110-7","article-title":"Tibiofemoral and tibiocalcaneal motion during walking: external vs. skeletal markers","volume":"6","author":"Reinschmidt C","year":"1997","unstructured":"Reinschmidt C, van den Bogert AJ, Lundberg A, Nigg BM, Murphy N, Stacoff A, Stano A. Tibiofemoral and tibiocalcaneal motion during walking: external vs. skeletal markers. Gait Posture. 1997, 6:98-109. 10.1016\/S0966-6362(97)01110-7","journal-title":"Gait Posture"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1016\/j.medengphy.2008.03.003","article-title":"Validation of three-dimensional model-based tibio-femoral tracking during running","volume":"31","author":"Anderst W","year":"2009","unstructured":"Anderst W, Zauel R, Bishop J, Demps E, Tashman S. Validation of three-dimensional model-based tibio-femoral tracking during running. Med Eng Phys. 2009, 31:10-16. 10.1016\/j.medengphy.2008.03.003","journal-title":"Med Eng Phys"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.5759\/jscas.18.71","article-title":"Validation of 3-dimensional postoperative evaluation technique in total knee arthroplasty","volume":"18","author":"Inoue T","year":"2016","unstructured":"Inoue T, Abe N, Fujiwara K, et al.. Validation of 3-dimensional postoperative evaluation technique in total knee arthroplasty. J Japan Soc Comput Aided Surg. 2016, 18:71-79. 10.5759\/jscas.18.71","journal-title":"J Japan Soc Comput Aided Surg"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1115\/1.1933949","article-title":"Theoretical accuracy of model-based shape matching for measuring natural knee kinematics with single-plane fluoroscopy","volume":"127","author":"Fregly BJ","year":"2005","unstructured":"Fregly BJ, Rahman HA, Banks SA. Theoretical accuracy of model-based shape matching for measuring natural knee kinematics with single-plane fluoroscopy. J Biomech Eng. 2005, 127:692-699. 10.1115\/1.1933949","journal-title":"J Biomech Eng"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1016\/s0268-0033(98)00009-6","article-title":"Three-dimensional determination of femoral-tibial contact positions under in vivo conditions using fluoroscopy","volume":"13","author":"Hoff WA","year":"1998","unstructured":"Hoff WA, Komistek RD, Dennis DA, Gabriel SM, Walker SA. Three-dimensional determination of femoral-tibial contact positions under in vivo conditions using fluoroscopy. Clin Biomech (Bristol, Avon). 1998, 13:455-472. 10.1016\/s0268-0033(98)00009-6","journal-title":"Clin Biomech (Bristol, Avon)"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1186\/1749-799X-4-6","article-title":"New fluoroscopic imaging technique for investigation of 6DOF knee kinematics during treadmill gait","volume":"4","author":"Li G","year":"2009","unstructured":"Li G, Kozanek M, Hosseini A, Liu F, Van de Velde SK, Rubash HE. New fluoroscopic imaging technique for investigation of 6DOF knee kinematics during treadmill gait. J Orthop Surg Res. 2009, 4:6. 10.1186\/1749-799X-4-6","journal-title":"J Orthop Surg Res"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.1002\/jor.22596","article-title":"Three-dimensional motion analysis of the patellar component in total knee arthroplasty by the image matching method using image correlations","volume":"32","author":"Ishimaru M","year":"2014","unstructured":"Ishimaru M, Shiraishi Y, Ikebe S, Higaki H, Hino K, Onishi Y, Miura H. Three-dimensional motion analysis of the patellar component in total knee arthroplasty by the image matching method using image correlations. J Orthop Res. 2014, 32:619-626. 10.1002\/jor.22596","journal-title":"J Orthop Res"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0245134","article-title":"Quantitative analysis of dynamic computed tomography angiography for the detection of endoleaks after abdominal aorta aneurysm endovascular repair: a feasibility study","volume":"16","author":"Apfaltrer G","year":"2021","unstructured":"Apfaltrer G, Lavra F, Schoepf UJ, et al.. Quantitative analysis of dynamic computed tomography angiography for the detection of endoleaks after abdominal aorta aneurysm endovascular repair: a feasibility study. PLoS One. 2021, 16:e0245134. 10.1371\/journal.pone.0245134","journal-title":"PLoS One"},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2019-015389","article-title":"4D-CT angiography versus 3D-rotational angiography as the imaging modality for computational fluid dynamics of cerebral aneurysms","volume":"12","author":"Cancelliere NM","year":"2020","unstructured":"Cancelliere NM, Najafi M, Brina O, et al.. 4D-CT angiography versus 3D-rotational angiography as the imaging modality for computational fluid dynamics of cerebral aneurysms. J Neurointerv Surg. 2020, 12:626-630. 10.1136\/neurintsurg-2019-015389","journal-title":"J Neurointerv Surg"},{"key":"ref18","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A4162","article-title":"4D-CTA in neurovascular disease: a review","volume":"36","author":"Kortman HG","year":"2015","unstructured":"Kortman HG, Smit EJ, Oei MT, Manniesing R, Prokop M, Meijer FJ. 4D-CTA in neurovascular disease: a review. AJNR Am J Neuroradiol. 2015, 36:1026-1033. 10.3174\/ajnr.A4162","journal-title":"AJNR Am J Neuroradiol"},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.1017\/S1460396919001043","article-title":"Correlating lung tumour location and motion with respiration using 4D CT scans","volume":"20","author":"Siow T","year":"2021","unstructured":"Siow T, Lim S. Correlating lung tumour location and motion with respiration using 4D CT scans. J Radiother Practice. 2021, 20:17-21. 10.1017\/S1460396919001043","journal-title":"J Radiother Practice"},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.14140295","article-title":"Imaging characteristics of contralateral asymptomatic patellofemoral joints in patients with unilateral instability","volume":"273","author":"Demehri S","year":"2014","unstructured":"Demehri S, Thawait GK, Williams AA, Kompel A, Elias JJ, Carrino JA, Cosgarea AJ. Imaging characteristics of contralateral asymptomatic patellofemoral joints in patients with unilateral instability. Radiology. 2014, 273:821-830. 10.1148\/radiol.14140295","journal-title":"Radiology"},{"key":"ref21","doi-asserted-by":"publisher","DOI":"10.1120\/jacmp.v16i6.5620","article-title":"Impact of scanning parameters and breathing patterns on image quality and accuracy of tumor motion reconstruction in 4D CBCT: a phantom study","volume":"16","author":"Lee S","year":"2015","unstructured":"Lee S, Yan G, Lu B, Kahler D, Li JG, Sanjiv SS. Impact of scanning parameters and breathing patterns on image quality and accuracy of tumor motion reconstruction in 4D CBCT: a phantom study. J Appl Clin Med Phys. 2015, 16:195-212. 10.1120\/jacmp.v16i6.5620","journal-title":"J Appl Clin Med Phys"},{"key":"ref22","doi-asserted-by":"publisher","DOI":"10.3791\/59857","article-title":"Four-dimensional CT analysis using sequential 3D-3D registration","volume":"153","author":"Oki S","year":"2019","unstructured":"Oki S, Kaneda K, Yamada Y, et al.. Four-dimensional CT analysis using sequential 3D-3D registration. J Vis Exp. 2019, 153:10.3791\/59857","journal-title":"J Vis Exp"},{"key":"ref23","doi-asserted-by":"publisher","DOI":"10.18926\/AMO\/52008","article-title":"A new navigation system for minimally invasive total knee arthroplasty","volume":"67","author":"Yokoyama Y","year":"2013","unstructured":"Yokoyama Y, Abe N, Fujiwara K, et al.. A new navigation system for minimally invasive total knee arthroplasty. Acta Med Okayama. 2013, 67:351-358. 10.18926\/AMO\/52008","journal-title":"Acta Med Okayama"},{"key":"ref24","doi-asserted-by":"publisher","DOI":"10.1016\/j.radonc.2009.12.028","article-title":"Inter-observer and intra-observer reliability for lung cancer target volume delineation in the 4D-CT era","volume":"95","author":"Louie AV","year":"2010","unstructured":"Louie AV, Rodrigues G, Olsthoorn J, et al.. Inter-observer and intra-observer reliability for lung cancer target volume delineation in the 4D-CT era. Radiother Oncol. 2010, 95:166-171. 10.1016\/j.radonc.2009.12.028","journal-title":"Radiother Oncol"},{"key":"ref25","doi-asserted-by":"publisher","DOI":"10.1118\/1.3110073","article-title":"Impact of motion velocity on four-dimensional target volumes: a phantom study","volume":"36","author":"Nakamura M","year":"2009","unstructured":"Nakamura M, Narita Y, Sawada A, et al.. Impact of motion velocity on four-dimensional target volumes: a phantom study. Med Phys. 2009, 36:1610-1617. 10.1118\/1.3110073","journal-title":"Med Phys"},{"key":"ref26","doi-asserted-by":"publisher","DOI":"10.1016\/j.radonc.2010.04.019","article-title":"Deviations in delineated GTV caused by artefacts in 4DCT","volume":"96","author":"Persson GF","year":"2010","unstructured":"Persson GF, Nygaard DE, Brink C, Jahn JW, Munck af Rosensch\u00f6ld P, Specht L, Korreman SS. Deviations in delineated GTV caused by artefacts in 4DCT. Radiother Oncol. 2010, 96:61-66. 10.1016\/j.radonc.2010.04.019","journal-title":"Radiother Oncol"},{"key":"ref27","doi-asserted-by":"publisher","DOI":"10.1016\/0968-0160(96)00210-4","article-title":"Quantitative assessment of skin-bone movement at the knee","volume":"3","author":"Sati M","year":"1996","unstructured":"Sati M, de Guise JA, Larouche S, Drouin G. Quantitative assessment of skin-bone movement at the knee. Knee. 1996, 3:121-138. 10.1016\/0968-0160(96)00210-4","journal-title":"Knee"},{"key":"ref28","doi-asserted-by":"publisher","DOI":"10.1016\/S0966-6362(96)01088-0","article-title":"Surface movement errors in shank kinematics and knee kinetics during gait","volume":"5","author":"Holden JP","year":"1997","unstructured":"Holden JP, Orsini JA, Siegel KL, Kepple TM, Gerber LH, Stanhope SJ. Surface movement errors in shank kinematics and knee kinetics during gait. Gait Posture. 1997, 5:217-227. 10.1016\/S0966-6362(96)01088-0","journal-title":"Gait Posture"},{"key":"ref29","doi-asserted-by":"publisher","DOI":"10.1097\/RLI.0000000000000603","article-title":"Development of upright computed tomography with area detector for whole-body scans: phantom study, efficacy on workflow, effect of gravity on human body, and potential clinical impact","volume":"55","author":"Jinzaki M","year":"2020","unstructured":"Jinzaki M, Yamada Y, Nagura T, et al.. Development of upright computed tomography with area detector for whole-body scans: phantom study, efficacy on workflow, effect of gravity on human body, and potential clinical impact. Invest Radiol. 2020, 55:73-83. 10.1097\/RLI.0000000000000603","journal-title":"Invest Radiol"},{"key":"ref30","doi-asserted-by":"publisher","DOI":"10.1177\/0363546507308547","article-title":"Influence of anterior cruciate ligament bundles on knee kinematics: clinical assessment using computer-assisted navigation","volume":"35","author":"Robinson J","year":"2007","unstructured":"Robinson J, Carrat L, Granchi C, Colombet P. Influence of anterior cruciate ligament bundles on knee kinematics: clinical assessment using computer-assisted navigation. Am J Sports Med. 2007, 35:2006-2013. 10.1177\/0363546507308547","journal-title":"Am J Sports Med"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/125220-accuracy-verification-of-four-dimensional-ct-analysis-of-knee-joint-movements-a-pilot-study-using-a-knee-joint-model-and-motion-capture-system","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,2,9]],"date-time":"2024-02-09T19:54:05Z","timestamp":1707508445000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/125220-accuracy-verification-of-four-dimensional-ct-analysis-of-knee-joint-movements-a-pilot-study-using-a-knee-joint-model-and-motion-capture-system"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,2,28]]},"references-count":30,"URL":"https:\/\/doi.org\/10.7759\/cureus.35616","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2023,2,28]]}}}