{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,23]],"date-time":"2026-03-23T10:40:11Z","timestamp":1774262411892,"version":"3.50.1"},"reference-count":11,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2023,5,9]]},"DOI":"10.7759\/cureus.38773","type":"journal-article","created":{"date-parts":[[2023,5,9]],"date-time":"2023-05-09T16:56:26Z","timestamp":1683651386000},"source":"Crossref","is-referenced-by-count":1,"title":["Two Cases of Intraoperative ECG Artifact Mimicking Ventricular Tachycardia and How to Know When It Is Real"],"prefix":"10.7759","author":[{"given":"Alexander M","family":"DeLeon","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jessica J","family":"Weeks","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lydia","family":"Su","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Vicente","family":"Garcia Tomas","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1056\/NEJM199910213411704","article-title":"Clinical consequences of electrocardiographic artifact mimicking ventricular tachycardia","volume":"341","author":"Knight BP","year":"1999","unstructured":"Knight BP, Pelosi F, Michaud GF, Strickberger SA, Morady F. Clinical consequences of electrocardiographic artifact mimicking ventricular tachycardia. N Engl J Med. 1999, 341:1270-4. 10.1056\/NEJM199910213411704","journal-title":"N Engl J Med"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1097\/AAP.0000000000000720","article-title":"The third American Society of Regional Anesthesia and Pain Medicine practice advisory on local anesthetic systemic toxicity: Executive Summary 2017","volume":"43","author":"Neal JM","year":"2018","unstructured":"Neal JM, Barrington MJ, Fettiplace MR, et al.. The third American Society of Regional Anesthesia and Pain Medicine practice advisory on local anesthetic systemic toxicity: Executive Summary 2017. Reg Anesth Pain Med. 2018, 43:113-23. 10.1097\/AAP.0000000000000720","journal-title":"Reg Anesth Pain Med"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1097\/ALN.0000000000002821","article-title":"Practice advisory for the perioperative management of patients with cardiac implantable electronic devices: pacemakers and implantable cardioverter-defibrillators 2020: an updated report by the American Society of Anesthesiologists task force on perioperative management of patients with cardiac implantable electronic devices","volume":"132","author":"Apfelbaum JL","year":"2020","unstructured":"Apfelbaum JL, Schulman PM, Mahajan A, Connis RT, Agarkar M. Practice advisory for the perioperative management of patients with cardiac implantable electronic devices: pacemakers and implantable cardioverter-defibrillators 2020: an updated report by the American Society of Anesthesiologists task force on perioperative management of patients with cardiac implantable electronic devices. Anesthesiology. 2020, 132:225-52. 10.1097\/ALN.0000000000002821","journal-title":"Anesthesiology"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9343(01)00627-1","article-title":"Physician interpretation of electrocardiographic artifact that mimics ventricular tachycardia","volume":"110","author":"Knight BP","year":"2001","unstructured":"Knight BP, Pelosi F, Michaud GF, Strickberger SA, Morady F. Physician interpretation of electrocardiographic artifact that mimics ventricular tachycardia. Am J Med. 2001, 110:335-8. 10.1016\/S0002-9343(01)00627-1","journal-title":"Am J Med"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.4103\/1658-354X.65124","article-title":"Ventricular tachycardia during microdebrider-assisted turbinectomy: an electrocardiographic artifact","volume":"4","author":"Sofi K","year":"2010","unstructured":"Sofi K, Khalid AS, Mushtaq Gilani KA. Ventricular tachycardia during microdebrider-assisted turbinectomy: an electrocardiographic artifact. Saudi J Anaesth. 2010, 4:111-3. 10.4103\/1658-354X.65124","journal-title":"Saudi J Anaesth"},{"key":"ref6","doi-asserted-by":"crossref","DOI":"10.1177\/194589240301700203","article-title":"Ventricular tachycardia as an electrocardiography artifact during functional endoscopic sinus surgery","volume":"17","author":"Gaiser RR","year":"2003","unstructured":"Gaiser RR, Demetry DJ, Schlosser R. Ventricular tachycardia as an electrocardiography artifact during functional endoscopic sinus surgery. Am J Rhinol. 2003, 17:83-5.","journal-title":"Am J Rhinol"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1097\/00008506-200104000-00012","article-title":"Pseudoarrythmia from evoked potential monitoring","volume":"13","author":"Marco AP","year":"2001","unstructured":"Marco AP, Rice K. Pseudoarrythmia from evoked potential monitoring. J Neurosurg Anesthesiol. 2001, 13:143-5. 10.1097\/00008506-200104000-00012","journal-title":"J Neurosurg Anesthesiol"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1046\/j.1460-9592.1998.00005.x","article-title":"Electrocardiographic artefact with SSEP monitoring unit during scoliosis surgery","volume":"8","author":"Choudhry DK","year":"1998","unstructured":"Choudhry DK, Stayer SA, Rehman MA, Schwartz RE. Electrocardiographic artefact with SSEP monitoring unit during scoliosis surgery. Paediatr Anaesth. 1998, 8:341-3. 10.1046\/j.1460-9592.1998.00005.x","journal-title":"Paediatr Anaesth"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1213\/00000539-199007000-00016","article-title":"Electrocardiographic artifacts during cardiopulmonary bypass","volume":"71","author":"Khambatta HJ","year":"1990","unstructured":"Khambatta HJ, Stone JG, Wald A, Mongero LB. Electrocardiographic artifacts during cardiopulmonary bypass. Anesth Analg. 1990, 71:88-91. 10.1213\/00000539-199007000-00016","journal-title":"Anesth Analg"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.4037\/AJCC2006.15.3.310","article-title":"Electrocardiographic artifact mimicking ventricular tachycardia during high-frequency oscillatory ventilation: a case report","volume":"15","author":"Patel S","year":"2006","unstructured":"Patel S. Electrocardiographic artifact mimicking ventricular tachycardia during high-frequency oscillatory ventilation: a case report. Am J Crit Care. 2006, 15:310-1. 10.4037\/AJCC2006.15.3.310","journal-title":"Am J Crit Care"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1097\/01.anes.0000296537.62905.25","article-title":"Equipment-related electrocardiographic artifacts: causes, characteristics, consequences, and correction","volume":"108","author":"Patel SI","year":"2008","unstructured":"Patel SI, Souter MJ. Equipment-related electrocardiographic artifacts: causes, characteristics, consequences, and correction. Anesthesiology. 2008, 108:138-48. 10.1097\/01.anes.0000296537.62905.25","journal-title":"Anesthesiology"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/151123-two-cases-of-intraoperative-ecg-artifact-mimicking-ventricular-tachycardia-and-how-to-know-when-it-is-real","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,2,9]],"date-time":"2024-02-09T19:59:12Z","timestamp":1707508752000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/151123-two-cases-of-intraoperative-ecg-artifact-mimicking-ventricular-tachycardia-and-how-to-know-when-it-is-real"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,5,9]]},"references-count":11,"URL":"https:\/\/doi.org\/10.7759\/cureus.38773","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2023,5,9]]}}}