{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,2,10]],"date-time":"2024-02-10T00:32:17Z","timestamp":1707525137529},"reference-count":15,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2023,5,11]]},"DOI":"10.7759\/cureus.38903","type":"journal-article","created":{"date-parts":[[2023,5,11]],"date-time":"2023-05-11T20:40:15Z","timestamp":1683837615000},"source":"Crossref","is-referenced-by-count":0,"title":["The Incidence of Optic Cracks or Fractures During a Foldable AcrySof or Acriva BB Acrylic Monofocal Intraocular Lens Implantation via the Manual Monarch Injector System With the Cartridge in Phacoemulsification Surgery"],"prefix":"10.7759","author":[{"given":"Cem","family":"Evereklioglu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yusuf","family":"Uysal","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hidayet","family":"Sener","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hatice K\u00fcbra","family":"S\u00f6nmez","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fatih","family":"Horozoglu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1016\/s0886-3350(02)01526-2","article-title":"Comparison of secondary implantation of flexible open-loop anterior chamber and scleral-fixated posterior chamber intraocular lenses","volume":"29","author":"Evereklioglu C","year":"2003","unstructured":"Evereklioglu C, Er H, Bekir NA, Borazan M, Zorlu F. Comparison of secondary implantation of flexible open-loop anterior chamber and scleral-fixated posterior chamber intraocular lenses. J Cataract Refract Surg. 2003, 29:301-8. 10.1016\/s0886-3350(02)01526-2","journal-title":"J Cataract Refract Surg"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1186\/s12886-017-0661-6","article-title":"Comparison of efficacy between coaxial microincision and standard-incision phacoemulsification in patients with age-related cataracts: a meta-analysis","volume":"17","author":"Wang L","year":"2017","unstructured":"Wang L, Xiao X, Zhao L, et al.. Comparison of efficacy between coaxial microincision and standard-incision phacoemulsification in patients with age-related cataracts: a meta-analysis. BMC Ophthalmol. 2017, 17:267. 10.1186\/s12886-017-0661-6","journal-title":"BMC Ophthalmol"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20060301-07","article-title":"Wavefront aberrations in eyes with Acrysof monofocal intraocular lenses","volume":"22","author":"Padmanabhan P","year":"2006","unstructured":"Padmanabhan P, Yoon G, Porter J, Rao SK, Roy J, Choudhury M. Wavefront aberrations in eyes with Acrysof monofocal intraocular lenses. J Refract Surg. 2006, 22:237-42. 10.3928\/1081-597X-20060301-07","journal-title":"J Refract Surg"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2019.05.027","article-title":"Blue light-filtering and violet light-filtering hydrophobic acrylic foldable intraocular lenses: Intraindividual comparison","volume":"45","author":"Nakano S","year":"2019","unstructured":"Nakano S, Miyata A, Kizawa J, Kurosaka D, Miyata K, Oshika T. Blue light-filtering and violet light-filtering hydrophobic acrylic foldable intraocular lenses: Intraindividual comparison. J Cataract Refract Surg. 2019, 45:1393-7. 10.1016\/j.jcrs.2019.05.027","journal-title":"J Cataract Refract Surg"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0273431","article-title":"Comparison of two one-piece acrylic foldable intraocular lenses: Short-term change in axial movement after cataract surgery and its effect on refraction","volume":"17","author":"Goto S","year":"2022","unstructured":"Goto S, Maeda N, Ohnuma K, Noda T. Comparison of two one-piece acrylic foldable intraocular lenses: Short-term change in axial movement after cataract surgery and its effect on refraction. PLoS One. 2022, 17:e0273431. 10.1371\/journal.pone.0273431","journal-title":"PLoS One"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2018.10.050","article-title":"In\u00a0vitro comparison of delivery performance of 4 preloaded intraocular lens injector systems for corneal and sclerocorneal incisions","volume":"45","author":"Oshika T","year":"2019","unstructured":"Oshika T, Wolfe P. In\u00a0vitro comparison of delivery performance of 4 preloaded intraocular lens injector systems for corneal and sclerocorneal incisions. J Cataract Refract Surg. 2019, 45:840-6. 10.1016\/j.jcrs.2018.10.050","journal-title":"J Cataract Refract Surg"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1016\/s0886-3350(00)00323-0","article-title":"Two year results: sharp versus rounded optic edges on silicone lenses","volume":"26","author":"Kruger AJ","year":"2000","unstructured":"Kruger AJ, Schauersberger J, Abela C, Schild G, Amon M. Two year results: sharp versus rounded optic edges on silicone lenses. J Cataract Refract Surg. 2000, 26:566-70. 10.1016\/s0886-3350(00)00323-0","journal-title":"J Cataract Refract Surg"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0277687","article-title":"Analysis of uncorrected near visual acuity after extended depth-of-focus AcrySof\u00ae Vivity\u2122 intraocular lens implantation","volume":"17","author":"Jeon S","year":"2022","unstructured":"Jeon S, Choi A, Kwon H. Analysis of uncorrected near visual acuity after extended depth-of-focus AcrySof\u00ae Vivity\u2122 intraocular lens implantation. PLoS One. 2022, 17:e0277687. 10.1371\/journal.pone.0277687","journal-title":"PLoS One"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.2006.097857","article-title":"The course of surface deposits on a hydrophilic acrylic intraocular lens after implantation through a hexagonal cartridge","volume":"90","author":"Marcovich AL","year":"2006","unstructured":"Marcovich AL, Kleinmann G, Epstein D, Pollack A. The course of surface deposits on a hydrophilic acrylic intraocular lens after implantation through a hexagonal cartridge. Br J Ophthalmol. 2006, 90:1249-51. 10.1136\/bjo.2006.097857","journal-title":"Br J Ophthalmol"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1016\/j.colsurfb.2022.113093","article-title":"Surface modification of commercial intraocular lens by zwitterionic and antibiotic-loaded coating for preventing postoperative endophthalmitis","volume":"222","author":"Li K","year":"2023","unstructured":"Li K, Yu L, Ma L, et al.. Surface modification of commercial intraocular lens by zwitterionic and antibiotic-loaded coating for preventing postoperative endophthalmitis. Colloids Surf B Biointerfaces. 2023, 222:113093. 10.1016\/j.colsurfb.2022.113093","journal-title":"Colloids Surf B Biointerfaces"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.7759\/cureus.37223","article-title":"Comparison of the rate of posterior capsule opacification following combined treatment with topical dexamethasone 0.1% plus ketorolac 0.5% eye drops versus dexamethasone 0.1% alone: A 2-year, randomized clinical investigation","volume":"15","author":"Evereklioglu C","year":"2023","unstructured":"Evereklioglu C, Arda H, Sener H, Polat OA, Gumus K, Horozoglu F. Comparison of the rate of posterior capsule opacification following combined treatment with topical dexamethasone 0.1% plus ketorolac 0.5% eye drops versus dexamethasone 0.1% alone: A 2-year, randomized clinical investigation. Cureus. 2023, 15:e37223. 10.7759\/cureus.37223","journal-title":"Cureus"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2005.12.131","article-title":"Scanning electron microscopic analysis of acrylic intraocular lenses for microincision cataract surgery","volume":"32","author":"Mencucci R","year":"2006","unstructured":"Mencucci R, Ponchietti C, Nocentini L, Danielli D, Menchini U. Scanning electron microscopic analysis of acrylic intraocular lenses for microincision cataract surgery. J Cataract Refract Surg. 2006, 32:318-23. 10.1016\/j.jcrs.2005.12.131","journal-title":"J Cataract Refract Surg"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1007\/s10792-019-01193-7","article-title":"Scanning electron microscopy study of different one-piece foldable acrylic intraocular lenses after injection through microincisional cataract surgery cartridges","volume":"40","author":"Cecchini P","year":"2020","unstructured":"Cecchini P, D'Aloisio R, De Giacinto C, Turco G, Tognetto D. Scanning electron microscopy study of different one-piece foldable acrylic intraocular lenses after injection through microincisional cataract surgery cartridges. Int Ophthalmol. 2020, 40:369-76. 10.1007\/s10792-019-01193-7","journal-title":"Int Ophthalmol"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1016\/s0886-3350(98)80015-1","article-title":"Cartridge cracks during foldable intraocular lens insertion","volume":"24","author":"Singh AD","year":"1998","unstructured":"Singh AD, Fang T, Rath R. Cartridge cracks during foldable intraocular lens insertion. J Cataract Refract Surg. 1998, 24:1220-2. 10.1016\/s0886-3350(98)80015-1","journal-title":"J Cataract Refract Surg"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2011.07.028","article-title":"Changes in intraocular lens surface roughness during cataract surgery assessed by atomic force microscopy","volume":"38","author":"Strauss RW","year":"2012","unstructured":"Strauss RW, Hochleitner ME, Gsenger W, et al.. Changes in intraocular lens surface roughness during cataract surgery assessed by atomic force microscopy. J Cataract Refract Surg. 2012, 38:146-54. 10.1016\/j.jcrs.2011.07.028","journal-title":"J Cataract Refract Surg"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/134859-the-incidence-of-optic-cracks-or-fractures-during-a-foldable-acrysof-or-acriva-bb-acrylic-monofocal-intraocular-lens-implantation-via-the-manual-monarch-injector-system-with-the-cartridge-in-phacoemulsification-surgery","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,2,9]],"date-time":"2024-02-09T20:00:23Z","timestamp":1707508823000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/134859-the-incidence-of-optic-cracks-or-fractures-during-a-foldable-acrysof-or-acriva-bb-acrylic-monofocal-intraocular-lens-implantation-via-the-manual-monarch-injector-system-with-the-cartridge-in-phacoemulsification-surgery"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,5,11]]},"references-count":15,"URL":"https:\/\/doi.org\/10.7759\/cureus.38903","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2023,5,11]]}}}