{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,30]],"date-time":"2026-03-30T10:34:12Z","timestamp":1774866852797,"version":"3.50.1"},"reference-count":15,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2023,7,5]]},"DOI":"10.7759\/cureus.41423","type":"journal-article","created":{"date-parts":[[2023,7,5]],"date-time":"2023-07-05T23:28:27Z","timestamp":1688599707000},"source":"Crossref","is-referenced-by-count":2,"title":["Artificial Pneumothorax Using the Liver-Directed Approach and Seldinger\u2019s Technique: Technical Feasibility and Safety"],"prefix":"10.7759","author":[{"given":"Mizuki","family":"Ozawa","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Miyuki","family":"Sone","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shunsuke","family":"Sugawara","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chihiro","family":"Itou","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shintaro","family":"Kimura","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yasuaki","family":"Arai","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masahiko","family":"Kusumoto","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2006.02.001","article-title":"CT-guided needle biopsy of lung lesions: a survey of severe complication based on 9783 biopsies in Japan","volume":"59","author":"Tomiyama N","year":"2006","unstructured":"Tomiyama N, Yasuhara Y, Nakajima Y, et al.. CT-guided needle biopsy of lung lesions: a survey of severe complication based on 9783 biopsies in Japan. Eur J Radiol. 2006, 59:60-4. 10.1016\/j.ejrad.2006.02.001","journal-title":"Eur J Radiol"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(18)31497-1","article-title":"A century ago: Carlo Forlanini and the first successful treatment of tuberculosis","volume":"392","author":"Garbarino MC","year":"2018","unstructured":"Garbarino MC, Cani V, Mazzarello P, et al.. A century ago: Carlo Forlanini and the first successful treatment of tuberculosis. Lancet. 2018, 392:475. 10.1016\/S0140-6736(18)31497-1","journal-title":"Lancet"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1186\/s12885-021-08223-7","article-title":"Artificial pneumothorax improves radiofrequency ablation of pulmonary metastases of hepatocellular carcinoma close to mediastinum","volume":"21","author":"Zuo T","year":"2021","unstructured":"Zuo T, Lin W, Liu F, Xu J. Artificial pneumothorax improves radiofrequency ablation of pulmonary metastases of hepatocellular carcinoma close to mediastinum. BMC Cancer. 2021, 21:505. 10.1186\/s12885-021-08223-7","journal-title":"BMC Cancer"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1007\/s11604-021-01148-y","article-title":"Feasibility, safety, and efficacy of artificial carbon dioxide pneumothorax for computed tomography fluoroscopy-guided percutaneous radiofrequency ablation of hepatocellular carcinoma","volume":"39","author":"Shibamoto K","year":"2021","unstructured":"Shibamoto K, Mimura H, Fukuhara Y, Nishino K, Kawamoto H, Kato K. Feasibility, safety, and efficacy of artificial carbon dioxide pneumothorax for computed tomography fluoroscopy-guided percutaneous radiofrequency ablation of hepatocellular carcinoma. Jpn J Radiol. 2021, 39:1119-26. 10.1007\/s11604-021-01148-y","journal-title":"Jpn J Radiol"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1007\/s00270-012-0508-8","article-title":"Transthoracic adrenal biopsy procedure using artificial carbon dioxide pneumothorax as outpatient procedure","volume":"36","author":"Favelier S","year":"2013","unstructured":"Favelier S, Guiu S, Cherblanc V, Cercueil JP, Kraus\u00e9 D, Guiu B. Transthoracic adrenal biopsy procedure using artificial carbon dioxide pneumothorax as outpatient procedure. Cardiovasc Intervent Radiol. 2013, 36:1184-7. 10.1007\/s00270-012-0508-8","journal-title":"Cardiovasc Intervent Radiol"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1097\/01.sla.0000133083.54934.ae","article-title":"Classification of surgical complications: a new proposal with evaluation in a cohort of 6336 patients and results of a survey","volume":"240","author":"Dindo D","year":"2004","unstructured":"Dindo D, Demartines N, Clavien PA. Classification of surgical complications: a new proposal with evaluation in a cohort of 6336 patients and results of a survey. Ann Surg. 2004, 240:205-13. 10.1097\/01.sla.0000133083.54934.ae","journal-title":"Ann Surg"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2008.10.020","article-title":"Artificial pneumothorax with position adjustment for computed tomography-guided percutaneous core biopsy of mediastinum lesions","volume":"87","author":"Lin ZY","year":"2009","unstructured":"Lin ZY, Li YG. Artificial pneumothorax with position adjustment for computed tomography-guided percutaneous core biopsy of mediastinum lesions. Ann Thorac Surg. 2009, 87:920-4. 10.1016\/j.athoracsur.2008.10.020","journal-title":"Ann Thorac Surg"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2362040992","article-title":"Artificially induced pneumothorax for percutaneous transthoracic radiofrequency ablation of tumors in the hepatic dome: initial experience","volume":"236","author":"de Ba\u00e8re T","year":"2005","unstructured":"de Ba\u00e8re T, Dromain C, Lapeyre M, et al.. Artificially induced pneumothorax for percutaneous transthoracic radiofrequency ablation of tumors in the hepatic dome: initial experience. Radiology. 2005, 236:666-70. 10.1148\/radiol.2362040992","journal-title":"Radiology"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.4103\/0019-509X.172519","article-title":"Artificial pneumothorax for pain relief during microwave ablation of subpleural lung tumors","volume":"52 Suppl 2","author":"Yang X","year":"2015","unstructured":"Yang X, Zhang K, Ye X, et al.. Artificial pneumothorax for pain relief during microwave ablation of subpleural lung tumors. Indian J Cancer. 2015, 52 Suppl 2:e80-3. 10.4103\/0019-509X.172519","journal-title":"Indian J Cancer"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.4103\/2156-7514.170732","article-title":"Percutaneous CT-guided ablation in the hepatic dome: artificially induced pneumothorax for safe transpleural access","volume":"5","author":"Valle LG","year":"2015","unstructured":"Valle LG, Rochal RD, Rahal A Jr, Garcia RG. Percutaneous CT-guided ablation in the hepatic dome: artificially induced pneumothorax for safe transpleural access. J Clin Imaging Sci. 2015, 5:63. 10.4103\/2156-7514.170732","journal-title":"J Clin Imaging Sci"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1080\/13645706.2017.1287089","article-title":"Artificial pneumothorax: a safe and simple method to relieve pain during microwave ablation of subpleural lung malignancy","volume":"26","author":"Hou X","year":"2017","unstructured":"Hou X, Zhuang X, Zhang H, Wang K, Zhang Y. Artificial pneumothorax: a safe and simple method to relieve pain during microwave ablation of subpleural lung malignancy. Minim Invasive Ther Allied Technol. 2017, 26:220-6. 10.1080\/13645706.2017.1287089","journal-title":"Minim Invasive Ther Allied Technol"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1111\/1759-7714.13137","article-title":"Efficacy and safety of artificial pneumothorax with position adjustment for CT-guided percutaneous transthoracic microwave ablation of small subpleural lung tumors","volume":"10","author":"Jia H","year":"2019","unstructured":"Jia H, Tian J, Liu B, Meng H, Pan F, Li C. Efficacy and safety of artificial pneumothorax with position adjustment for CT-guided percutaneous transthoracic microwave ablation of small subpleural lung tumors. Thorac Cancer. 2019, 10:1710-6. 10.1111\/1759-7714.13137","journal-title":"Thorac Cancer"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1080\/13645706.2020.1814341","article-title":"Artificially induced pneumothorax with a Veress needle for cryoablation of renal cell carcinoma","volume":"31","author":"Maeda H","year":"2022","unstructured":"Maeda H, Kajiwara K, Yoshimatsu R, et al.. Artificially induced pneumothorax with a Veress needle for cryoablation of renal cell carcinoma. Minim Invasive Ther Allied Technol. 2022, 31:483-6. 10.1080\/13645706.2020.1814341","journal-title":"Minim Invasive Ther Allied Technol"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1016\/j.crad.2014.07.012","article-title":"Percutaneous radiofrequency ablation of hepatic tumours: factors affecting technical failure of artificial ascites formation using an angiosheath","volume":"69","author":"Kang TW","year":"2014","unstructured":"Kang TW, Lee MW, Hye MJ, et al.. Percutaneous radiofrequency ablation of hepatic tumours: factors affecting technical failure of artificial ascites formation using an angiosheath. Clin Radiol. 2014, 69:1249-58. 10.1016\/j.crad.2014.07.012","journal-title":"Clin Radiol"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.08.2122","article-title":"Incidence of bleeding after 15,181 percutaneous biopsies and the role of aspirin","volume":"194","author":"Atwell TD","year":"2010","unstructured":"Atwell TD, Smith RL, Hesley GK, et al.. Incidence of bleeding after 15,181 percutaneous biopsies and the role of aspirin. AJR Am J Roentgenol. 2010, 194:784-9. 10.2214\/AJR.08.2122","journal-title":"AJR Am J Roentgenol"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/163648-artificial-pneumothorax-using-the-liver-directed-approach-and-seldingers-technique-technical-feasibility-and-safety","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,2,9]],"date-time":"2024-02-09T20:02:06Z","timestamp":1707508926000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/163648-artificial-pneumothorax-using-the-liver-directed-approach-and-seldingers-technique-technical-feasibility-and-safety"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,7,5]]},"references-count":15,"URL":"https:\/\/doi.org\/10.7759\/cureus.41423","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2023,7,5]]}}}