{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,2,10]],"date-time":"2024-02-10T00:31:00Z","timestamp":1707525060310},"reference-count":11,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2023,7,26]]},"DOI":"10.7759\/cureus.42510","type":"journal-article","created":{"date-parts":[[2023,7,27]],"date-time":"2023-07-27T00:18:44Z","timestamp":1690417124000},"source":"Crossref","is-referenced-by-count":0,"title":["Direct Screw Osteosynthesis for an Elderly Osteoporotic Patient With C2 Complex Fracture"],"prefix":"10.7759","author":[{"given":"Yoshitaka","family":"Nagashima","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yusuke","family":"Nishimura","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mamoru","family":"Matsuo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takafumi","family":"Tanei","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ryuta","family":"Saito","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1097\/BSD.0000000000001093","article-title":"Hangman's fracture","volume":"33","author":"Turtle J","year":"2020","unstructured":"Turtle J, Kantor A, Spina NT, France JC, Lawrence BD. Hangman's fracture. Clin Spine Surg. 2020, 33:345-54. 10.1097\/BSD.0000000000001093","journal-title":"Clin Spine Surg"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1155\/2019\/4301051","article-title":"Characteristics and management of emergency department patients presenting with C2 cervical spine fractures","volume":"2019","author":"Tadros A","year":"2019","unstructured":"Tadros A, Sharon M, Craig K, Krantz W. Characteristics and management of emergency department patients presenting with C2 cervical spine fractures. Biomed Res Int. 2019, 2019:4301051. 10.1155\/2019\/4301051","journal-title":"Biomed Res Int"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.3171\/2017.3.SPINE161176","article-title":"Patterns of C-2 fracture in the elderly: comparison of etiology, treatment, and mortality among specific fracture types","volume":"27","author":"Radovanovic I","year":"2017","unstructured":"Radovanovic I, Urquhart JC, Rasoulinejad P, Gurr KR, Siddiqi F, Bailey CS. Patterns of C-2 fracture in the elderly: comparison of etiology, treatment, and mortality among specific fracture types. J Neurosurg Spine. 2017, 27:494-500. 10.3171\/2017.3.SPINE161176","journal-title":"J Neurosurg Spine"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1007\/s00586-010-1401-2","article-title":"Transpedicular screw fixation for type II hangman's fracture: a motion preserving procedure","volume":"19","author":"ElMiligui Y","year":"2010","unstructured":"ElMiligui Y, Koptan W, Emran I. Transpedicular screw fixation for type II hangman's fracture: a motion preserving procedure. Eur Spine J. 2010, 19:1299-305. 10.1007\/s00586-010-1401-2","journal-title":"Eur Spine J"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1055\/s-0035-1550343","article-title":"Traumatic spondylolisthesis of the axis vertebra in adults","volume":"5","author":"Schleicher P","year":"2015","unstructured":"Schleicher P, Scholz M, Pingel A, Kandziora F. Traumatic spondylolisthesis of the axis vertebra in adults. Global Spine J. 2015, 5:346-58. 10.1055\/s-0035-1550343","journal-title":"Global Spine J"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.25259\/SNI_235_2022","article-title":"Case of pedicle lag screw fixation for oblique axis body and pars fractures with displacement","volume":"13","author":"Rehman RU","year":"2022","unstructured":"Rehman RU, Akhtar MS, Bibi A. Case of pedicle lag screw fixation for oblique axis body and pars fractures with displacement. Surg Neurol Int. 2022, 13:133. 10.25259\/SNI_235_2022","journal-title":"Surg Neurol Int"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1016\/j.wneu.2016.06.047","article-title":"Direct C2 pedicle screw fixation for axis body fracture","volume":"93","author":"Reynolds JA","year":"2016","unstructured":"Reynolds JA, MacDonald JD. Direct C2 pedicle screw fixation for axis body fracture. World Neurosurg. 2016, 93:279-85. 10.1016\/j.wneu.2016.06.047","journal-title":"World Neurosurg"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.3171\/jns.1994.81.2.0206","article-title":"Fractures of the C-2 vertebral body","volume":"81","author":"Benzel EC","year":"1994","unstructured":"Benzel EC, Hart BL, Ball PA, Baldwin NG, Orrison WW, Espinosa M. Fractures of the C-2 vertebral body. J Neurosurg. 1994, 81:206-12. 10.3171\/jns.1994.81.2.0206","journal-title":"J Neurosurg"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1007\/s00586-013-3158-x","article-title":"Surgical management of the fractures of axis body: indications and surgical strategy","volume":"23","author":"Zhang YS","year":"2014","unstructured":"Zhang YS, Zhang JX, Yang QG, Shen CL, Li W, Yin ZS. Surgical management of the fractures of axis body: indications and surgical strategy. Eur Spine J. 2014, 23:1633-40. 10.1007\/s00586-013-3158-x","journal-title":"Eur Spine J"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1016\/j.wneu.2017.08.075","article-title":"Evaluation of correction of radiologic parameters (angulation and displacement) and accuracy of C2 pedicle screw placement in unstable hangman\u2019s fracture with intraoperative computed tomography-based navigation","volume":"107","author":"Singh PK","year":"2017","unstructured":"Singh PK, Verma SK, Garg M, et al.. Evaluation of correction of radiologic parameters (angulation and displacement) and accuracy of C2 pedicle screw placement in unstable hangman\u2019s fracture with intraoperative computed tomography-based navigation. World Neurosurg. 2017, 107:795-802. 10.1016\/j.wneu.2017.08.075","journal-title":"World Neurosurg"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.18999\/nagjms.83.4.861","article-title":"Piecemeal resection of aggressive vertebral hemangioma using real-time navigation-guided drilling technique","volume":"83","author":"Nagashima Y","year":"2021","unstructured":"Nagashima Y, Nishimura Y, Haimoto S, et al.. Piecemeal resection of aggressive vertebral hemangioma using real-time navigation-guided drilling technique. Nagoya J Med Sci. 2021, 83:861-8. 10.18999\/nagjms.83.4.861","journal-title":"Nagoya J Med Sci"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/173415-direct-screw-osteosynthesis-for-an-elderly-osteoporotic-patient-with-c2-complex-fracture","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,2,9]],"date-time":"2024-02-09T20:05:16Z","timestamp":1707509116000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/173415-direct-screw-osteosynthesis-for-an-elderly-osteoporotic-patient-with-c2-complex-fracture"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,7,26]]},"references-count":11,"URL":"https:\/\/doi.org\/10.7759\/cureus.42510","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2023,7,26]]}}}