{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,8,13]],"date-time":"2024-08-13T22:56:42Z","timestamp":1723589802256},"reference-count":22,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2023,9,28]]},"DOI":"10.7759\/cureus.46148","type":"journal-article","created":{"date-parts":[[2023,9,28]],"date-time":"2023-09-28T20:26:56Z","timestamp":1695932816000},"source":"Crossref","is-referenced-by-count":0,"title":["Widening Access: Sterile Tourniquets for Surgery to the Distal Humerus"],"prefix":"10.7759","author":[{"given":"Christian","family":"Warner","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christopher","family":"Peach","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ronnie","family":"Davies","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1177\/1753193410390845","article-title":"Pain and paraesthesia produced by silicone ring and pneumatic tourniquets","volume":"36","author":"Mohan A","year":"2011","unstructured":"Mohan A, Baskaradas A, Solan M, Magnussen P. Pain and paraesthesia produced by silicone ring and pneumatic tourniquets. J Hand Surg Eur Vol. 2011, 36:215-8. 10.1177\/1753193410390845","journal-title":"J Hand Surg Eur Vol"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2014.11.022","article-title":"The sterile elastic exsanguination tourniquet vs. the pneumatic tourniquet for total knee arthroplasty","volume":"30","author":"Brin YS","year":"2015","unstructured":"Brin YS, Feldman V, Ron Gal I, Markushevitch M, Regev A, Stern A. The sterile elastic exsanguination tourniquet vs. the pneumatic tourniquet for total knee arthroplasty. J Arthroplasty. 2015, 30:595-9. 10.1016\/j.arth.2014.11.022","journal-title":"J Arthroplasty"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.5812\/ircmj.9588","article-title":"Tourniquet in surgery of the limbs: a review of history, types and complications","volume":"17","author":"Saied A","year":"2015","unstructured":"Saied A, Mousavi AA, Arabnejad F, Heshmati AA. Tourniquet in surgery of the limbs: a review of history, types and complications. Iran Red Crescent Med J. 2015, 17:e9588. 10.5812\/ircmj.9588","journal-title":"Iran Red Crescent Med J"},{"key":"ref4","article-title":"A comparison of operative field space between sterile single use and re-useable pneumatic tourniquets in revision total knee arthroplasty","volume":"1","author":"Ved A","year":"2015","unstructured":"Ved A, Pj K, Sharma H, Morgan-Jones R. A comparison of operative field space between sterile single use and re-useable pneumatic tourniquets in revision total knee arthroplasty. Int J Orthod Sci. 2015, 1:1-3.","journal-title":"Int J Orthod Sci"},{"key":"ref5","article-title":"The effect of the silicone ring tourniquet and standard pneumatic tourniquet on the motor nerve conduction, pain and grip strength in healthy volunteers","volume":"4","author":"Drosos GI","year":"2016","unstructured":"Drosos GI, Kiziridis G, Aggelopoulou C, Galiatsatos D, Anastassopoulos G, Ververidis A, Kazakos K. The effect of the silicone ring tourniquet and standard pneumatic tourniquet on the motor nerve conduction, pain and grip strength in healthy volunteers. Arch Bone Jt Surg. 2016, 4:16-22.","journal-title":"Arch Bone Jt Surg"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1097\/BTH.0b013e3181b56187","article-title":"Use of a new exsanguination tourniquet in internal fixation of distal radius fractures","volume":"13","author":"Norman D","year":"2009","unstructured":"Norman D, Greenfield I, Ghrayeb N, Peled E, Dayan L. Use of a new exsanguination tourniquet in internal fixation of distal radius fractures. Tech Hand Up Extrem Surg. 2009, 13:173-5. 10.1097\/BTH.0b013e3181b56187","journal-title":"Tech Hand Up Extrem Surg"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1097\/01202412-200609000-00014","article-title":"A novel elastic exsanguination tourniquet as an alternative to the pneumatic cuff in pediatric orthopedic limb surgery","volume":"15","author":"Eidelman M","year":"2006","unstructured":"Eidelman M, Katzman A, Bialik V. A novel elastic exsanguination tourniquet as an alternative to the pneumatic cuff in pediatric orthopedic limb surgery. J Pediatr Orthop B. 2006, 15:379-84. 10.1097\/01202412-200609000-00014","journal-title":"J Pediatr Orthop B"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1007\/s00402-010-1144-x","article-title":"Silicone ring versus pneumatic cuff tourniquet: a comparative quantitative study in healthy individuals","volume":"131","author":"Drosos GI","year":"2011","unstructured":"Drosos GI, Stavropoulos NI, Kazakos K, Tripsianis G, Ververidis A, Verettas DA. Silicone ring versus pneumatic cuff tourniquet: a comparative quantitative study in healthy individuals. Arch Orthop Trauma Surg. 2011, 131:447-54. 10.1007\/s00402-010-1144-x","journal-title":"Arch Orthop Trauma Surg"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.5435\/00124635-200109000-00008","article-title":"Pneumatic tourniquets in extremity surgery","volume":"9","author":"Wakai A","year":"2001","unstructured":"Wakai A, Winter DC, Street JT, Redmond PH. Pneumatic tourniquets in extremity surgery. J Am Acad Orthop Surg. 2001, 9:345-51. 10.5435\/00124635-200109000-00008","journal-title":"J Am Acad Orthop Surg"},{"key":"ref10","unstructured":"BOAST - the safe use of intraoperative tourniquets. (2021). Accessed. November 8, 2022: https:\/\/www.boa.ac.uk\/resource\/boast-the-safe-use-of-intraoperative-tourniquets.html."},{"key":"ref11","unstructured":"HemaClear for bloodless surgical field during limb surgery. (2019). Accessed. November 8, 2022: https:\/\/www.nice.org.uk\/advice\/mib187."},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.5301\/jva.5000520","article-title":"Narrow elastic disposable tourniquet (Hemaclear\u00ae) vs. traditional wide pneumatic tourniquet for creation or revision of hemodialysis angioaccesses","volume":"17","author":"Bourquelot P","year":"2016","unstructured":"Bourquelot P, Levy BI. Narrow elastic disposable tourniquet (Hemaclear\u00ae) vs. traditional wide pneumatic tourniquet for creation or revision of hemodialysis angioaccesses. J Vasc Access. 2016, 17:205-9. 10.5301\/jva.5000520","journal-title":"J Vasc Access"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1308\/147870811X13137608455334","article-title":"The effect of sterile versus non-sterile tourniquets on microbiological colonisation in lower limb surgery","volume":"93","author":"Thompson SM","year":"2011","unstructured":"Thompson SM, Middleton M, Farook M, Cameron-Smith A, Bone S, Hassan A. The effect of sterile versus non-sterile tourniquets on microbiological colonisation in lower limb surgery. Ann R Coll Surg Engl. 2011, 93:589-90. 10.1308\/147870811X13137608455334","journal-title":"Ann R Coll Surg Engl"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1016\/j.jor.2018.05.025","article-title":"Silicone ring tourniquet versus pneumatic cuff tourniquet in total knee arthroplasty surgery: A randomised comparative study","volume":"15","author":"Le\u00f3n-Mu\u00f1oz VJ","year":"2018","unstructured":"Le\u00f3n-Mu\u00f1oz VJ, Lis\u00f3n-Almagro AJ, Hern\u00e1ndez-Garc\u00eda CH, L\u00f3pez-L\u00f3pez M. Silicone ring tourniquet versus pneumatic cuff tourniquet in total knee arthroplasty surgery: A randomised comparative study. J Orthop. 2018, 15:545-8. 10.1016\/j.jor.2018.05.025","journal-title":"J Orthop"},{"key":"ref15","article-title":"The silicone ring tourniquet in orthopaedic operations of the extremities","volume":"23","author":"Drosos GI","year":"2013","unstructured":"Drosos GI, Ververidis A, Mavropoulos R, Vastardis G, Tsioros KI, Kazakos K. The silicone ring tourniquet in orthopaedic operations of the extremities. Surg Technol Int. 2013, 23:251-7.","journal-title":"Surg Technol Int"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.1007\/s00264-016-3160-0","article-title":"Silicone ring tourniquet or pneumatic cuff tourniquet for total knee arthroplasty","volume":"40","author":"Jenny JY","year":"2016","unstructured":"Jenny JY, Bahlau D, Wisniewski S. Silicone ring tourniquet or pneumatic cuff tourniquet for total knee arthroplasty. Int Orthop. 2016, 40:1803-6. 10.1007\/s00264-016-3160-0","journal-title":"Int Orthop"},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcot.2020.09.005","article-title":"Comparison of local pain and tissue reaction between conventional pneumatic tourniquet and disposable silicone ring tourniquet during total knee arthroplasty","volume":"15","author":"Londhe SB","year":"2021","unstructured":"Londhe SB, Shah RV, Londhe SS, Agrawal PO, Antao NA, Churhe S. Comparison of local pain and tissue reaction between conventional pneumatic tourniquet and disposable silicone ring tourniquet during total knee arthroplasty. J Clin Orthop Trauma. 2021, 15:152-5. 10.1016\/j.jcot.2020.09.005","journal-title":"J Clin Orthop Trauma"},{"key":"ref18","doi-asserted-by":"publisher","DOI":"10.1007\/s10195-012-0223-x","article-title":"Silicone ring tourniquet versus pneumatic cuff tourniquet in carpal tunnel release: a randomized comparative study","volume":"14","author":"Drosos GI","year":"2013","unstructured":"Drosos GI, Ververidis A, Stavropoulos NI, Mavropoulos R, Tripsianis G, Kazakos K. Silicone ring tourniquet versus pneumatic cuff tourniquet in carpal tunnel release: a randomized comparative study. J Orthop Traumatol. 2013, 14:131-5. 10.1007\/s10195-012-0223-x","journal-title":"J Orthop Traumatol"},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.3928\/01477447-20151123-08","article-title":"Pulmonary embolism after application of a sterile elastic exsanguination tourniquet","volume":"38","author":"Feldman V","year":"2015","unstructured":"Feldman V, Biadsi A, Slavin O, Kish B, Tauber I, Nyska M, Brin YS. Pulmonary embolism after application of a sterile elastic exsanguination tourniquet. Orthopedics. 2015, 38:e1160-3. 10.3928\/01477447-20151123-08","journal-title":"Orthopedics"},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.5435\/00124635-200509000-00001","article-title":"Distal humerus fractures","volume":"13","author":"Anglen J","year":"2005","unstructured":"Anglen J. Distal humerus fractures. J Am Acad Orthop Surg. 2005, 13:291-7. 10.5435\/00124635-200509000-00001","journal-title":"J Am Acad Orthop Surg"},{"key":"ref21","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2021.02.017","article-title":"Complications of articular distal humeral fracture fixation: a systematic review and meta-analysis","volume":"30","author":"Yetter TR","year":"2021","unstructured":"Yetter TR, Weatherby PJ, Somerson JS. Complications of articular distal humeral fracture fixation: a systematic review and meta-analysis. J Shoulder Elbow Surg. 2021, 30:1957-67. 10.1016\/j.jse.2021.02.017","journal-title":"J Shoulder Elbow Surg"},{"key":"ref22","doi-asserted-by":"publisher","DOI":"10.1007\/s00590-020-02626-1","article-title":"Management of distal humerus fractures","volume":"30","author":"Lauder A","year":"2020","unstructured":"Lauder A, Richard MJ. Management of distal humerus fractures. Eur J Orthop Surg Traumatol. 2020, 30:745-62. 10.1007\/s00590-020-02626-1","journal-title":"Eur J Orthop Surg Traumatol"}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/161266-widening-access-sterile-tourniquets-for-surgery-to-the-distal-humerus","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,2,9]],"date-time":"2024-02-09T20:10:19Z","timestamp":1707509419000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/161266-widening-access-sterile-tourniquets-for-surgery-to-the-distal-humerus"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,9,28]]},"references-count":22,"URL":"https:\/\/doi.org\/10.7759\/cureus.46148","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2023,9,28]]}}}