{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,4,12]],"date-time":"2025-04-12T11:26:46Z","timestamp":1744457206767},"reference-count":11,"publisher":"Springer Science and Business Media LLC","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2023,10,26]]},"DOI":"10.7759\/cureus.47761","type":"journal-article","created":{"date-parts":[[2023,10,27]],"date-time":"2023-10-27T02:49:51Z","timestamp":1698374991000},"source":"Crossref","is-referenced-by-count":2,"title":["Second-Degree Burns in Neonates: A Rare Case Report of Saturation Probe Injury in Neonates"],"prefix":"10.7759","author":[{"given":"Kushal","family":"Desai","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Amar","family":"Taksande","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Revat J","family":"Meshram","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"ref1","article-title":"Pulse oximeter-associated toe injuries in a premature neonate: a case report","volume":"62","author":"Lin CW","year":"1999","unstructured":"Lin CW, Wang HZ, Hsieh KS. Pulse oximeter-associated toe injuries in a premature neonate: a case report. Zhonghua Yi Xue Za Zhi (Taipei). 1999, 62:914-6.","journal-title":"Zhonghua Yi Xue Za Zhi (Taipei)"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jpedsurg.2012.06.033","article-title":"Management of pulse oximeter probe-induced finger injuries in children: report of two consecutive cases and review of the literature","volume":"47","author":"Ceran C","year":"2012","unstructured":"Ceran C, Taner OF, Tekin F, Tezcan S, Tekin O, Civelek B. Management of pulse oximeter probe-induced finger injuries in children: report of two consecutive cases and review of the literature. J Pediatr Surg. 2012, 47:e27-9. 10.1016\/j.jpedsurg.2012.06.033","journal-title":"J Pediatr Surg"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1016\/j.burns.2008.08.020","article-title":"Pulse oximeter probe-induced electrical burn","volume":"35","author":"Jung SN","year":"2009","unstructured":"Jung SN, Hwang DY, Kim J, Kwon H, Yim YM. Pulse oximeter probe-induced electrical burn. Burns. 2009, 35:751-3. 10.1016\/j.burns.2008.08.020","journal-title":"Burns"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1111\/iwj.13375","article-title":"A case of a hand burns associated with a \"wrap-around\" pulse oximeter in an infant","volume":"17","author":"Hisham A","year":"2020","unstructured":"Hisham A, Hafizuddin Bin Salleh M, Ibrahim S, Mohd Yussof SJ. A case of a hand burns associated with a \"wrap-around\" pulse oximeter in an infant. Int Wound J. 2020, 17:1097-8. 10.1111\/iwj.13375","journal-title":"Int Wound J"},{"key":"ref5","unstructured":"Skin integrity issues associated with pulse oximetry. (2005). Accessed. October 20, 2023: https:\/\/patientsafety.pa.gov\/ADVISORIES\/Pages\/200506_25.aspx."},{"key":"ref6","article-title":"Neonatal burn injuries: an agony for the newborn as well as the burn care team","volume":"26","author":"Saaiq M","year":"2013","unstructured":"Saaiq M, Ahmad S, Zaib S. Neonatal burn injuries: an agony for the newborn as well as the burn care team. Ann Burns Fire Disasters. 2013, 26:175-81.","journal-title":"Ann Burns Fire Disasters"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1097\/BCR.0b013e31828a8d5a","article-title":"Thermal injuries caused by medical instruments: a case report of burns caused by a pulse oximeter","volume":"35","author":"Bunker DL","year":"2014","unstructured":"Bunker DL, Kumar R, Martin A, Pegg SP. Thermal injuries caused by medical instruments: a case report of burns caused by a pulse oximeter. J Burn Care Res. 2014, 35:e132-4. 10.1097\/BCR.0b013e31828a8d5a","journal-title":"J Burn Care Res"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1097\/01.bcr.0000138295.63830.90","article-title":"Temperature threshold for burn injury: an oximeter safety study","volume":"25","author":"Greenhalgh DG","year":"2004","unstructured":"Greenhalgh DG, Lawless MB, Chew BB, Crone WA, Fein ME, Palmieri TL. Temperature threshold for burn injury: an oximeter safety study. J Burn Care Rehabil. 2004, 25:411-5. 10.1097\/01.bcr.0000138295.63830.90","journal-title":"J Burn Care Rehabil"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-199008000-00028","article-title":"Severe burns from a pulse oximeter","volume":"73","author":"Murphy KG","year":"1990","unstructured":"Murphy KG, Secunda JA, Rockoff MA. Severe burns from a pulse oximeter. Anesthesiology. 1990, 73:350-2. 10.1097\/00000542-199008000-00028","journal-title":"Anesthesiology"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1007\/BF03012991","article-title":"Thermal injury with pulse oximeter probe in hypothermic patient. Pulse oximeter probe burn in hypothermia","volume":"46","author":"Pandey CK","year":"1999","unstructured":"Pandey CK, Rani A, Srivastava K, Baronia A, Agarwal A. Thermal injury with pulse oximeter probe in hypothermic patient. Pulse oximeter probe burn in hypothermia. Can J Anaesth. 1999, 46:908-9. 10.1007\/BF03012991","journal-title":"Can J Anaesth"},{"key":"ref11","unstructured":"Pulse oximeter accuracy and limitations. FDA safety communication. (2022). Accessed: June 14, 2023: https:\/\/www.fda.gov\/medical-devices\/safety-communications\/pulse-oximeter-accuracy-and-limitations-fda-safety-communic...."}],"container-title":["Cureus"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cureus.com\/articles\/198088-second-degree-burns-in-neonates-a-rare-case-report-of-saturation-probe-injury-in-neonates","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,2,9]],"date-time":"2024-02-09T20:07:56Z","timestamp":1707509276000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cureus.com\/articles\/198088-second-degree-burns-in-neonates-a-rare-case-report-of-saturation-probe-injury-in-neonates"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,10,26]]},"references-count":11,"URL":"https:\/\/doi.org\/10.7759\/cureus.47761","relation":{},"ISSN":["2168-8184"],"issn-type":[{"value":"2168-8184","type":"print"}],"subject":[],"published":{"date-parts":[[2023,10,26]]}}}